YLYing Li

Ying Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ying Li has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Carol Friedman

    Department of Biomedical Informatics, Columbia University Medical Center, 622 W. 168th Street, Presbyterian Building 20th Floor, New York, NY, 10032, USA

    1 shared publication
  • Patrick B. Ryan

    Department of Biomedical Informatics, Columbia University Medical Center, 622 W. 168th Street, Presbyterian Building 20th Floor, New York, NY, 10032, USA

    1 shared publication
  • Ying Wei

    Department of Biostatistics, Columbia University, New York, NY, 10032, USA

    1 shared publication

Latest Publications

  • Open Access

    A Method to Combine Signals from Spontaneous Reporting Systems and Observational Healthcare Data to Detect Adverse Drug Reactions

    by Ying Li, Patrick B. Ryan, Ying Wei, Carol Friedman

    Introduction Observational healthcare data contain information useful for hastening detection of adverse drug reactions (ADRs) that may be missed by using data in spontaneous reporting systems (SRSs) alone. There are only several papers describing methods that integrate evidence from healthcare databases and SRSs. We propose a methodology that combines ADR signals from these two sources. Objectives The aim of this study was to investigate whether the proposed method would result in more accurate ADR detection than methods using SRSs or healthcare data alone. Research Design We applied the method to four clinically serious ADRs, and evaluated it using three experiments that involve combining an SRS with a single facility small-scale electronic health record (EHR), a larger scale network-based EHR, and a much larger scale healthcare claims database. The evaluation used a reference standard comprising 165 positive and 234 negative drug–ADR pairs. Measures Area under the receiver operator characteristics curve (AUC) was computed to measure performance. Results There was no improvement in the AUC when the SRS and small-scale HER were combined. The AUC of the combined SRS and large-scale EHR was 0.82 whereas it was 0.76 for each of the individual systems. Similarly, the AUC of the combined SRS and claims system was 0.82 whereas it was 0.76 and 0.78, respectively, for the individual systems. Conclusions The proposed method resulted in a significant improvement in the accuracy of ADR detection when the resources used for combining had sufficient amounts of data, demonstrating that the method could integrate evidence from multiple sources and serve as a tool in actual pharmacovigilance practice.