Liya Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liya Huang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bin Li
Department of Laboratory Medicine, Fujian Medical University Union Hospital, Fuzhou, People’s Republic of China
2 shared publications - Qili Lin
Medical Technology and Engineering College, Fujian Medical University, Fuzhou, 350004 Fujian People's Republic of China
2 shared publications - Fang-Jun Lan
Department of Clinical Laboratory, Fujian Medical University Union Hospital, 29 Xinquan Rd, Fuzhou, Fujian 350001 People's Republic of China
1 shared publication - Jingling Zhang
Medical Technology and Engineering College, Fujian Medical University, Fuzhou, 350004, Fujian, People's Republic of China
1 shared publication - Maobai Liu
Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China
1 shared publication - Qingwen He
Department of Clinical Laboratory, Fujian Medical University Union Hospital, 29 Xinquan Rd., Fuzhou, 350001, Fujian, People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 1 August 2017
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
- Vol. 6 (1) , 1-6
Evaluation of automated systems for aminoglycosides and fluoroquinolones susceptibility testing for Carbapenem-resistant Enterobacteriaceae
Automated systems (MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact) are widely used in clinical laboratories nowadays. The aim of this study is to evaluate the performance of these three systems for susceptibility testing of aminoglycosides and fluoroquinolones against Carbapenem-resistant Enterobacteriaceae (CRE). A total of 75 CRE isolates were used in this study. Quinolone resistance determinants (QRDs) (qnrA, qnrB, qnrC, qnrD, qnrS, aac(6′)-Ib-cr, oqxAB and qepA) and aminoglycoside resistance determinants (ARDs) (aac(6′)-Ib, armA, npmA, rmtA, rmtB, rmtC, rmtD and rmtE) of these CRE were screened by PCR. The MICs of aminoglycosides (gentamicin and amikacin) and fluoroquinolones (ciprofloxacin and levofloxacin) to CRE obtained with the automated systems were compared with the reference method (agar dilution method). Totally, 97.3% (73/75) of CRE harbored QRDs. The qnr gene was the most common QRD determinant identified in 68 (96.7%), followed by aac (6′)-Ib-cr in 56 (74.7%), oqxAB in 23 (30.7%), and qepA in 2 (2.7%), respectively. 22.7% (17/75) of CRE harbored ARD determinants. rmtA, rmtB and npmA were identified among these isolates in 6 (8.0%), 6 (8.0%) and 5 (6.7%), respectively. A total of 900 results were obtained in this study. Overall, the total error rate was 9.89%. Twenty-eight very major errors (3.11%), 22 major errors (2.44%) and 39 minor errors (4.33%) were identified against agar dilution method. The very major errors were almost evenly distributed between results for fluoroquinolones (2.89%) and aminoglycosides (3.33%), while the major errors and minor errors were more commonly found in the results of fluoroquinolones (3.11% and 6.44%, respectively) than aminoglycosides (1.78% and 2.22%, respectively). Our study shows that testing difficulties in susceptibility testing do exist in automated systems. We suggest clinical laboratories using automated systems should consider using a second, independent antimicrobial susceptibility testing method to validate aminoglycosides and fluoroquinolones susceptibility.
- 1 August 2017
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
- Vol. 6 (1) , 1-6
Open AccessEvaluation of automated systems for aminoglycosides and fluoroquinolones susceptibility testing for Carbapenem-resistant Enterobacteriaceae
Automated systems (MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact) are widely used in clinical laboratories nowadays. The aim of this study is to evaluate the performance of these three systems for susceptibility testing of aminoglycosides and fluoroquinolones against Carbapenem-resistant Enterobacteriaceae (CRE). A total of 75 CRE isolates were used in this study. Quinolone resistance determinants (QRDs) (qnrA, qnrB, qnrC, qnrD, qnrS, aac(6′)-Ib-cr, oqxAB and qepA) and aminoglycoside resistance determinants (ARDs) (aac(6′)-Ib, armA, npmA, rmtA, rmtB, rmtC, rmtD and rmtE) of these CRE were screened by PCR. The MICs of aminoglycosides (gentamicin and amikacin) and fluoroquinolones (ciprofloxacin and levofloxacin) to CRE obtained with the automated systems were compared with the reference method (agar dilution method). Totally, 97.3% (73/75) of CRE harbored QRDs. The qnr gene was the most common QRD determinant identified in 68 (96.7%), followed by aac (6′)-Ib-cr in 56 (74.7%), oqxAB in 23 (30.7%), and qepA in 2 (2.7%), respectively. 22.7% (17/75) of CRE harbored ARD determinants. rmtA, rmtB and npmA were identified among these isolates in 6 (8.0%), 6 (8.0%) and 5 (6.7%), respectively. A total of 900 results were obtained in this study. Overall, the total error rate was 9.89%. Twenty-eight very major errors (3.11%), 22 major errors (2.44%) and 39 minor errors (4.33%) were identified against agar dilution method. The very major errors were almost evenly distributed between results for fluoroquinolones (2.89%) and aminoglycosides (3.33%), while the major errors and minor errors were more commonly found in the results of fluoroquinolones (3.11% and 6.44%, respectively) than aminoglycosides (1.78% and 2.22%, respectively). Our study shows that testing difficulties in susceptibility testing do exist in automated systems. We suggest clinical laboratories using automated systems should consider using a second, independent antimicrobial susceptibility testing method to validate aminoglycosides and fluoroquinolones susceptibility.
- Open Access
- 21 June 2016
- Published by Springer Nature in Annals of Clinical Microbiology and Antimicrobials
- Vol. 15 (1) , 1-6
Performance evaluation of three automated identification systems in detecting carbapenem-resistant Enterobacteriaceae
Carbapenem-resistant Enterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably, one Klebsiella pneumoniae isolate produced both IMP-4 and NDM-1. One Klebsiella oxytoca isolate produced both KPC-2 and IMP-8. Of the 81 clinical CRE isolates, 56 (69.1 %), 33 (40.7 %) and 77 (95.1 %) were identified as CRE by MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, respectively. The sensitivities/specificities of MicroScan WalkAway, Phoenix 100 and Vitek 2 were 93.8/42.4 %, 54.2/66.7 %, and 75.0/36.4 %, respectively. The MicroScan WalkAway and Viteck2 systems are more reliable in clinical identification of CRE, whereas additional tests are required for the Pheonix 100 system. Our study provides a useful guideline for using automated identification systems for CRE identification.
- 21 June 2016
- Published by Springer Nature in Annals of Clinical Microbiology and Antimicrobials
- Vol. 15 (1) , 1-6
Open AccessPerformance evaluation of three automated identification systems in detecting carbapenem-resistant Enterobacteriaceae
Carbapenem-resistant Enterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably, one Klebsiella pneumoniae isolate produced both IMP-4 and NDM-1. One Klebsiella oxytoca isolate produced both KPC-2 and IMP-8. Of the 81 clinical CRE isolates, 56 (69.1 %), 33 (40.7 %) and 77 (95.1 %) were identified as CRE by MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, respectively. The sensitivities/specificities of MicroScan WalkAway, Phoenix 100 and Vitek 2 were 93.8/42.4 %, 54.2/66.7 %, and 75.0/36.4 %, respectively. The MicroScan WalkAway and Viteck2 systems are more reliable in clinical identification of CRE, whereas additional tests are required for the Pheonix 100 system. Our study provides a useful guideline for using automated identification systems for CRE identification.