Alexander Egan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander Egan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Brian B. Avants
Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States
1 shared publication - James C. Gee
Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
1 shared publication - Nicholas James Tustison
University of Virginia
1 shared publication - Paul A. Yushkevich
Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
1 shared publication - Philip A. Cook
Department of Radiology, Perelman School of Medicine, University of Pennsylvania
1 shared publication - Yuanjie Zheng
School of Computer Science and Artificial Intelligence, Shandong Normal University, Jinan, Shandong, China
1 shared publication
Latest Publications
- Top Cited Papers
- 8 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 29 (6) , 1310-1320
N4ITK: Improved N3 Bias Correction
A variant of the popular nonparametric nonuniform intensity normalization (N3) algorithm is proposed for bias field correction. Given the superb performance of N3 and its public availability, it has been the subject of several evaluation studies. These studies have demonstrated the importance of certain parameters associated with the B -spline least-squares fitting. We propose the substitution of a recently developed fast and robust B-spline approximation routine and a modified hierarchical optimization scheme for improved bias field correction over the original N3 algorithm. Similar to the N3 algorithm, we also make the source code, testing, and technical documentation of our contribution, which we denote as ¿N4ITK,¿ available to the public through the Insight Toolkit of the National Institutes of Health. Performance assessment is demonstrated using simulated data from the publicly available Brainweb database, hyperpolarized 3 He lung image data, and 9.4T postmortem hippocampus data.
- 8 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 29 (6) , 1310-1320
Top Cited PapersN4ITK: Improved N3 Bias Correction
A variant of the popular nonparametric nonuniform intensity normalization (N3) algorithm is proposed for bias field correction. Given the superb performance of N3 and its public availability, it has been the subject of several evaluation studies. These studies have demonstrated the importance of certain parameters associated with the B -spline least-squares fitting. We propose the substitution of a recently developed fast and robust B-spline approximation routine and a modified hierarchical optimization scheme for improved bias field correction over the original N3 algorithm. Similar to the N3 algorithm, we also make the source code, testing, and technical documentation of our contribution, which we denote as ¿N4ITK,¿ available to the public through the Insight Toolkit of the National Institutes of Health. Performance assessment is demonstrated using simulated data from the publicly available Brainweb database, hyperpolarized 3 He lung image data, and 9.4T postmortem hippocampus data.