YYYasutaka Yokoyama

Yasutaka Yokoyama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yasutaka Yokoyama has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Coronary Artery Bypass Grafting in the Presence of Severe Hyperthyroidism: A Case Report

    by Akie Shimada, Taira Yamamoto, Jiyoung Lee, Shizuyuki Dohi, Daisuke Endo, Yuichiro Sato, Yasutaka Yokoyama, Minoru Tabata

    BACKGROUND In coronary artery bypass grafting, hyperthyroidism with autoantibodies, as seen in Basedow disease, is uncommon and rarely leads to severe thyrotoxicosis. However, surgery can trigger this condition, and documented cases have resulted in poor outcomes. We describe the case of an incidental hyperthyroidism finding on preoperative evaluation for coronary artery bypass grafting for triple-vessel coronary artery disease. CASE REPORT A 58-year-old man presented with exertional dyspnea, chest pain, and postprandial vomiting. Coronary angiography revealed severe triple-vessel disease. After admission, he experienced additional episodes of chest pain, which required continuous infusion of coronary vasodilators and strict bed rest. Preoperative screening showed severe hyperthyroidism. Thiamazole 80 mg/day and potassium iodide 50 mg/day were initiated but discontinued after 2 weeks because of leukopenia (white blood cell count, 2800×10⁹/L). Although thyroidectomy was considered, coronary artery bypass grafting was prioritized owing to cardiac risk concerns. Perioperative management included continuous hemodiafiltration dialysis, methylprednisolone (1000 mg/day), and slow plasma exchange, starting with surgery to prevent thyroid storm. Intravenous gamma globulin was administered 3 days before and after surgery. Free triiodothyronine and free thyroxine were normalized on postoperative days 3 and 7, respectively. The postoperative course was uneventful, and the patient remained symptom-free at 1-year follow-up. CONCLUSIONS Coronary artery bypass grafting with uncontrolled hyperthyroidism is prone to complications, and a thyroid storm can be fatal. Although surgery should be avoided in cases of uncontrolled hyperthyroidism, in rare cases in which urgent treatment is not feasible, a critical intervention as described in this report may prevent thyroid crisis.


  • Open Access

    Alto Deployment in Patients With Severe Tortuosity of the Proximal Aorta: An In Vitro Study

    by Yasutaka Yokoyama, Shizuyuki Dohi, Minoru Tabata

  • Open Access

    Acute endocarditis complicated by left ventricular pseudoaneurysm with acute bloody pericardial effusion: A case report

    by Akie Shimada, Taira Yamamoto, Shizuyuki Dohi, Yasutaka Yokoyama, Daisuke Endo, Minoru Tabata

    Rationale: Delay in seeking medical attention for high fever and inadequate diagnosis can lead to rapid progression of inflammation and spread to surrounding tissues and organs. Staphylococcus aureus is a common cause of systemic infections, and infectious endocarditis can swiftly become severe; therefore, careful management is required. Patient concerns: A 54-year-old woman was admitted to our hospital with high fever and progressive loss of consciousness. Meningitis was suspected, and antibiotic treatment was initiated. Blood culture revealed methicillin-sensitive Staphylococcus aureus. Subsequently, the patient developed hypotension, bradycardia, and cardiac arrest and underwent emergency cardiopulmonary resuscitation. Diagnoses: Transesophageal echocardiography performed during the procedure revealed significant vegetation at the posterior leaflet of the mitral valve, an abscess at the valve annulus, and a pseudoaneurysm of the left ventricular posterior wall. Interventions: The patient underwent emergency small incision pericardiotomy drainage, and her blood pressure and heart rate stabilized. After pericardial drainage, acute renal failure, fulminant hepatitis, and disruption of coagulation function were observed, and she was treated with plasma exchange therapy and intravenous immunoglobulin. Resection of the huge vegetation, debridement, patch closure of the ventricular perforation, and mitral valve replacement were performed. Outcomes: Surgical findings showed massive vegetation in the posterior leaflet of the mitral valve, an annular abscess in the posterior leaflet of the mitral valve connected to the left ventricular posterior wall, and a pseudoaneurysm. Postoperatively, her pseudoaneurysm resolved and her cardiac function stabilized, while circulatory failure due to bacteremia progressed, and she gradually developed acidosis and unstable blood pressure. Plasma exchange and continuous hemodiafiltration were continued; however, she died of progressive multiorgan failure. Lesson: Staphylococcus aureus bacteremia can cause fatal complications. Even when symptoms of meningitis are suspected, it is essential to examine the patient for endocarditis. Delayed diagnosis can lead to fatal endocarditis-related complications.

  • Open Access

    Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study

    by Yasutaka Yokoyama, Taira Yamamoto, Tetsuma Oyama, Jiyoung Lee, Yoichiro Machida, Daisuke Endo, Yuichiro Sato, Shizuyuki Dohi, Atsushi Amano, Minoru Tabata

    Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin. Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups. The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin.


  • Open Access

    Sternal closure with sandwiched three-piece bioresorbable mesh reduces postoperative hemorrhage: a retrospective study

    by Yasutaka Yokoyama, Taira Yamamoto, Tetsuma Oyama, Jiyoung Lee, Yoichiro Machida, Daisuke Endo, Yuichiro Sato, Shizuyuki Dohi, Atsushi Amano, Minoru Tabata

    Background: Median sternotomy is the most performed procedure in cardiac surgery; however, sternal bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative bleeding more than a bioresorbable pin. Methods: Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) was used during sternal reconstruction. The causes of postoperative bleeding and computed tomography data were analyzed and compared between the groups. Results: The preoperative patient characteristics did not significantly differ between the groups. However, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. Evaluation for sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 9 (8%) and 22 (20%) patients in groups M and P, respectively; the difference was significant. The four-grade evaluation of substernal hematoma based on computed tomography yielded a significantly lower grade for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. Conclusion: Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative bleeding and substernal hematoma more than sternal fixation with a pin.

  • Open Access

    Thoracic Endovascular Aortic Repair After Salvage Coronary Artery Bypass Graft for Type A Dissection

    by Yasutaka Yokoyama, Shizuyuki Dohi, Takeshi Kinoshita, Daisuke Endo, Taira Yamamoto, Atsushi Amano, Minoru Tabata

  • Open Access

    Two-stage aortic surgery for distal aortic arch and descending aorta aneurysms: A case report

    by Akie Shimada, Taira Yamamoto, Shizuyuki Dohi, Yasutaka Yokoyama, Daisuke Endo, Minoru Tabata

    Rationale: Although surgical treatment strategies for patients with extensive thoracic aortic disease involving the aortic arch have improved considerably, the impact of stent graft length and placement site on aortic remodeling at long-term follow-up is not fully understood, and the protection of the Adamkiewicz artery (AKA) using the frozen elephant trunk (FET) method is also unclear. Patient concerns: The patient was a 69-year-old man with diabetic nephropathy who became increasingly fatigued and started maintenance hemodialysis 6 months prior to admission. At 64 years, he underwent clipping of a right cerebellar artery aneurysm. In addition, a 1.8 cm aneurysm was found in the contralateral extracranial internal carotid artery. He also had an atrial septal defect and moderate aortic regurgitation and was receiving continuous positive airway pressure therapy for sleep apnoea syndrome. Diagnosis: He had aneurysms in the aortic arch (4.8 cm in diameter) and descending aorta (6 cm in diameter), which was located at T6–9. Preoperative 3-dimensional computed tomography showed that the (AKA) bifurcated at T10–11. Interventions: Considering the patient’s several comorbidities and frailty, we planned to perform 1-stage extended aortic arch repair using the FET procedure. However, we performed 2-stage aortic surgery to prevent spinal ischemia, anticipating substantial cardiac enlargement and blood pressure instability due to dialysis treatment. Aortic valve replacement, atrial septal defect patch closure, and aortic arch surgery were performed. A 7-cm elephant trunk was inserted in the descending aorta. Postoperatively, the patient continued rehabilitation until his blood pressure stabilized during dialysis therapy. At postoperative week 4, he underwent thoracic endovascular aortic repair for a descending aortic aneurysm. Outcomes: After surgery, his physical strength decreased; however, he recovered and was discharged 1 month later without any complications. One year after the second operation, he is living a healthy life. Lessons: Extensive aortic arch surgery using the FET procedure is effective for distal aortic arch and descending aortic aneurysms. Nevertheless, in cases in which the position of the AKA is close to the aortic aneurysm and blood pressure control is difficult, a 2-stage procedure and accurate positioning of thoracic endovascular aortic repair are both desirable.

  • Open Access

    The effect of tolvaptan on renal excretion of electrolytes and urea nitrogen in patients undergoing coronary artery bypass surgery

    by Tomoko S. Kato, Hiroshi Nakamura, Mai Murata, Kishio Kuroda, Hitoshi Suzuki, Yasutaka Yokoyama, Akie Shimada, Satoshi Matsushita, Taira Yamamoto, Atsushi Amano

    Adequate fluid management is an important component of patient care following cardiac surgery. Our aim in this study was to determine the benefits of tolvaptan, an oral selective vasopressin-2 receptor antagonist that causes electrolyte-free water diuresis, in postoperative fluid management. We prospectively examined the effect of tolvaptan on renal excretion of electrolytes and urea nitrogen in cardiac surgery patients. Patients undergoing coronary artery bypass surgery were randomized to receive conventional loop diuretics (Group C, n = 30) or conventional loop diuretic therapy plus tolvaptan (Group T, n = 27). Fractional excretions of sodium (FENA), potassium (FEK) and urea nitrogen (FEUN) were measured in both groups during post-surgical hospitalization. Urine output was greater with tolvaptan (Group T) than without it (Group C), and some patients in Group C required intravenous as well as oral loop diuretics. Serum sodium concentrations decreased after surgery in Group C, but were unchanged in Group T (postoperative day [POD] 3, 139.8 ± 3.5 vs. 142.3 ± 2.6 mEq/L, p = 0.006). However, postoperative FENA values in Group C did not decrease, and the values were similar in both groups. Serum potassium levels remained lower and FEK values remained higher than the preoperative values, but only in Group C (all p < 0.05). BUN increased postoperatively in both groups, but it remained higher than its preoperative value only in Group C (all p < 0.01). Group T showed an initial increase in BUN, which peaked and then returned to its preoperative value within a week. The FEUN increased postoperatively in both groups, but the change was more pronounced in Group T (POD7, 52.7 ± 9.3 vs. 58.2 ± 6.5 %, p = 0.025). Renal excretion of sodium and potassium reflects the changes in serum concentration in patients treated with tolvaptan. Patients treated only with loop diuretics showed a continuous excretion of sodium and potassium that led to electrolyte imbalance, whereas the combination of loop diuretics and tolvaptan increased renal urea nitrogen elimination. Tolvaptan therefore appears to be an effective diuretic that minimally affects serum electrolytes while adequately promoting the elimination of urea nitrogen from the kidneys in patients undergoing coronary artery bypass surgery. The present study is registered with the UMIN Clinical Trials Registry (ID: UMIN000011039 )


  • Open Access

    Advancements in Endovascular Aneurysm Repair for Various Types of Abdominal Aortic Aneurysms

    by Yasutaka Yokoyama

    Asymptomatic abdominal aortic aneurysm (AAA) is a common and potentially life-threatening condition. It should be repaired before its rupture, because ruptured AAA is nearly uniformly fatal. Elective repair is the most effective management for rupture prevention. Two methods of aneurysm repair are currently available, open surgery and endovascular aneurysm repair (EVAR). Open surgery is capable of treating various complexities of aneurysms, but EVAR is preferred in many cases due to its minimal invasiveness. Although it is not indicated for all patients, various advancements in endovascular treatment strategies allow for active treatment with EVAR in our department. This review article describes these advancements in EVAR.