John G. Marshall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
John G. Marshall has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
Peter Bowden
Research Analytical Biochemistry Laboratory, Department of Chemistry and Biology, Faculty of Science, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
17 shared publicationsAngelique Florentinus-Mefailoski
Ryerson University
9 shared publicationsJaimie Dufresne
Research Analytical Biochemistry Laboratory, Department of Chemistry and Biology, Faculty of Science, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario M5B 2K3, Canada
9 shared publicationsPeihong Zhu
Department of Chemistry and Biology, Ryerson University, 350 Victoria Street, Toronto, Canada
8 shared publications- Angelique Florentinus-Mefailoski
Ryerson Analytical Biochemistry Laboratory (RABL), Department of Chemistry and Biology, Faculty of Science, Ryerson University, Toronto, Canada
7 shared publications - Jaimie Dufresne
Ryerson University, 350 Victoria Street, Toronto, ON M5B 2K3 Canada
7 shared publications
Latest Publications
- 21 June 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 717, 116185
IgG detection by enzyme-linked mass spectrometric assay versus color, fluorescent, ECL in buffer and serum
- 21 June 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 717, 116185
IgG detection by enzyme-linked mass spectrometric assay versus color, fluorescent, ECL in buffer and serum
- Open Access
- 21 July 2025
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 43, 102160
Alkaline phosphatase–streptavidin conjugate (APSA) enzyme and binding activity over time and storage conditions
- 21 July 2025
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 43, 102160
Open AccessAlkaline phosphatase–streptavidin conjugate (APSA) enzyme and binding activity over time and storage conditions
- Open Access
- 10 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (11) , 10796-10811
Comparison of the Human Plasma Peptides from the Fit of Fragmentation Spectra versus Accurate Monoisotopic Precursor Mass
In nature, ionized peptides with heavy isotopes and hydrogen rearrangements show a broad mass distribution with signals at discrete delta mass values from -3 to +5 Da by mass spectrometry (MS). For many peptides, the intensity of the +1 or +2 Da isotope exceeds the signal from the monoisotopic mass. Therefore, there is a need for a method that improves peptide identification from heavy isotopes or hydrogen rearrangements based on the fit of tandem mass spectra. Peptides may be identified using an accurate monoisotopic precursor mass with ≤0.1 Da. However, many peptides with heavy isotopes and H-loss can be identified and enumerated based on the fit of their MS/MS spectra alone in the absence of an accurate precursor monoisotopic mass (i.e., ± 3 Da) using the X!TANDEM MS/MS fitting algorithm. In this study, human plasma samples were analyzed with a highly resolving axially harmonic orbital ion trap (OIT) and a sensitive linear quadrupole ion trap (LIT). The MS/MS fragmentation spectra from the OIT can be fit to peptides from the monoisotopic (±0.1 Da) as well as all other precursor masses with a wide mass tolerance (±3 Da). The resulting delta mass distribution can then be plotted and compared to the predicted distribution of heavy isotopes and hydrogen rearrangements to provide a direct biophysical prediction and test the validity of the fit determined by accepting the best-fit MS/MS spectra. The OIT instrument, which has greater resolution, was sampled at 30 nL per minute, while the more sensitive LIT was sampled at 200 nL per minute. The MS/MS spectra generated by each instrument were fit to peptides within a wide window (±3 Da) using the rigorous X!TANDEM algorithm. The OIT and LIT results were compared in an SQL Server database and corrected against analytical and statistical controls. The delta mass distribution of the peptides with hydrogen rearrangements and heavy isotopes was determined from the fit MS/MS spectra using the R statistical program. The OIT sampled MS and MS/MS spectra from the high-intensity precursor ions by focusing on E7 to E9 detector counts. In contrast, the LIT sampled a range of precursor ion intensities focused from E4 to E7 and thus reached lower ion intensity values. As expected, the precursor mass [M + H]+ obtained by the OIT exhibited sharp delta mass peaks at -3, -2, -1, 0, +1, +2, +3, +4, and +5 Da due to naturally occurring heavy isotopes and hydrogen rearrangements. The collection of peptides and proteins identified by OIT and LIT was in qualitative and quantitative agreement with one another, with 99.9% overlap on 2726 protein gene symbols from human plasma and a highly significant relationship by regression analysis. The protein p-values, false discovery rate q-values, and comparisons to the noise MS/MS analytical control and random MS/MS statistical control confirmed the high-confidence MS/MS identifications from both instruments. MS/MS fragmentation spectra from the OIT were fit to peptides. The resulting precursor ion delta mass distribution showed a precise match to the predicted isotope distributions and hydrogen rearrangements of natural peptides. Thus, analysis of delta mass plots provided powerful biophysical evidence for the accuracy of plasma peptide identification from the fit of the MS/MS spectra alone. The high level of agreement on proteins and peptides and the proportional enumeration between proteins identified by the OIT and those identified independently using a LIT confirmed that plasma peptides and proteins may be identified and quantified from MS/MS spectra alone without the need for an accurate measure of the precursor mass. The greater sensitivity and low cost of searching MS/MS spectra in the absence of an accurate mass mean that it is possible to identify and quantify more proteins for the discovery of proteins in clinical populations.
- 10 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (11) , 10796-10811
Open AccessComparison of the Human Plasma Peptides from the Fit of Fragmentation Spectra versus Accurate Monoisotopic Precursor Mass
In nature, ionized peptides with heavy isotopes and hydrogen rearrangements show a broad mass distribution with signals at discrete delta mass values from -3 to +5 Da by mass spectrometry (MS). For many peptides, the intensity of the +1 or +2 Da isotope exceeds the signal from the monoisotopic mass. Therefore, there is a need for a method that improves peptide identification from heavy isotopes or hydrogen rearrangements based on the fit of tandem mass spectra. Peptides may be identified using an accurate monoisotopic precursor mass with ≤0.1 Da. However, many peptides with heavy isotopes and H-loss can be identified and enumerated based on the fit of their MS/MS spectra alone in the absence of an accurate precursor monoisotopic mass (i.e., ± 3 Da) using the X!TANDEM MS/MS fitting algorithm. In this study, human plasma samples were analyzed with a highly resolving axially harmonic orbital ion trap (OIT) and a sensitive linear quadrupole ion trap (LIT). The MS/MS fragmentation spectra from the OIT can be fit to peptides from the monoisotopic (±0.1 Da) as well as all other precursor masses with a wide mass tolerance (±3 Da). The resulting delta mass distribution can then be plotted and compared to the predicted distribution of heavy isotopes and hydrogen rearrangements to provide a direct biophysical prediction and test the validity of the fit determined by accepting the best-fit MS/MS spectra. The OIT instrument, which has greater resolution, was sampled at 30 nL per minute, while the more sensitive LIT was sampled at 200 nL per minute. The MS/MS spectra generated by each instrument were fit to peptides within a wide window (±3 Da) using the rigorous X!TANDEM algorithm. The OIT and LIT results were compared in an SQL Server database and corrected against analytical and statistical controls. The delta mass distribution of the peptides with hydrogen rearrangements and heavy isotopes was determined from the fit MS/MS spectra using the R statistical program. The OIT sampled MS and MS/MS spectra from the high-intensity precursor ions by focusing on E7 to E9 detector counts. In contrast, the LIT sampled a range of precursor ion intensities focused from E4 to E7 and thus reached lower ion intensity values. As expected, the precursor mass [M + H]+ obtained by the OIT exhibited sharp delta mass peaks at -3, -2, -1, 0, +1, +2, +3, +4, and +5 Da due to naturally occurring heavy isotopes and hydrogen rearrangements. The collection of peptides and proteins identified by OIT and LIT was in qualitative and quantitative agreement with one another, with 99.9% overlap on 2726 protein gene symbols from human plasma and a highly significant relationship by regression analysis. The protein p-values, false discovery rate q-values, and comparisons to the noise MS/MS analytical control and random MS/MS statistical control confirmed the high-confidence MS/MS identifications from both instruments. MS/MS fragmentation spectra from the OIT were fit to peptides. The resulting precursor ion delta mass distribution showed a precise match to the predicted isotope distributions and hydrogen rearrangements of natural peptides. Thus, analysis of delta mass plots provided powerful biophysical evidence for the accuracy of plasma peptide identification from the fit of the MS/MS spectra alone. The high level of agreement on proteins and peptides and the proportional enumeration between proteins identified by the OIT and those identified independently using a LIT confirmed that plasma peptides and proteins may be identified and quantified from MS/MS spectra alone without the need for an accurate measure of the precursor mass. The greater sensitivity and low cost of searching MS/MS spectra in the absence of an accurate mass mean that it is possible to identify and quantify more proteins for the discovery of proteins in clinical populations.
- 5 March 2025
- Published by Elsevier in Analytical Biochemistry
- Vol. 702, 115822
Ammonium bicarbonate buffer system for DNA hybridization and quantification by LC-ESI-MS/MS
- 5 March 2025
- Published by Elsevier in Analytical Biochemistry
- Vol. 702, 115822
Ammonium bicarbonate buffer system for DNA hybridization and quantification by LC-ESI-MS/MS
- Open Access
- 2 January 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (1) , 281-293
Selected Ion Extraction of Peptides with Heavy Isotopes and Hydrogen Loss Reduces the Type II Error in Plasma Proteomics
Naturally occurring peptides display a wide mass distribution after ionization due to the presence of heavy isotopes of C, H, N, O, and S and hydrogen loss. There is a crucial need for sensitive methods that collect as much information as possible about all plasma peptide forms. Statistical analysis of the delta mass distribution of peptide precursors from MS/MS spectra that were matched to 63,077 peptide sequences by X!TANDEM revealed Gaussian peaks representing heavy isotopes and hydrogen loss at integer delta mass values of -3, -2, -1, 0, +1, +2, +3, +4, and +5 Da. Human plasma samples were precipitated in acetonitrile, and the resulting proteins were collected over a quaternary amine resin, eluted with NaCl, digested with trypsin, and analyzed by nano liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with an orbital ion trap (OIT). Fragment spectra (MS/MS) generated from the OIT data were fit to human fully tryptic peptides by X!TANDEM, which led to the identification of 3,888 protein gene symbols represented by three or more peptides (n ≥ 3). The peptide counts to plasma proteins from experimental MS/MS spectra were corrected against 29 blank LC-ESI-MS/MS spectra and 30 million random MS/MS control spectra to yield 2,784 true positive proteins (n ≥ 3; q ≤ 0.01). Peptides identified by fragmenting ions with Gaussian heavy isotopes and hydrogen loss that were matched to known plasma proteins, such as albumin (ALB), were shown to be true positives and agreed with the peptide sequences identified in the monoisotopic peak. Accepting the ions from the monoisotopic peak alone (±0.1 Da) yielded only 382 plasma proteins (n ≥ 3; type I error q ≤ 0.01; type II error ∼86%). In contrast, accepting all ions within ±0.1 Da around the hydrogen loss, monoisotopic, and heavy isotopic peaks led to the identification of 963 proteins (n ≥ 3; q ≤ 0.01; type II error ∼60%). Using the power of the OIT to resolve the Gaussian peaks from heavy isotopes and hydrogen loss resulted in the identification of three times more proteins with high confidence and a much lower type II error than analyzing peptides from the monoisotopic peak alone. The resolving power of the OIT may be exploited to increase observation frequencies and provide greater proteomic coverage and statistical power in comparative proteomics studies.
- 2 January 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (1) , 281-293
Open AccessSelected Ion Extraction of Peptides with Heavy Isotopes and Hydrogen Loss Reduces the Type II Error in Plasma Proteomics
Naturally occurring peptides display a wide mass distribution after ionization due to the presence of heavy isotopes of C, H, N, O, and S and hydrogen loss. There is a crucial need for sensitive methods that collect as much information as possible about all plasma peptide forms. Statistical analysis of the delta mass distribution of peptide precursors from MS/MS spectra that were matched to 63,077 peptide sequences by X!TANDEM revealed Gaussian peaks representing heavy isotopes and hydrogen loss at integer delta mass values of -3, -2, -1, 0, +1, +2, +3, +4, and +5 Da. Human plasma samples were precipitated in acetonitrile, and the resulting proteins were collected over a quaternary amine resin, eluted with NaCl, digested with trypsin, and analyzed by nano liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with an orbital ion trap (OIT). Fragment spectra (MS/MS) generated from the OIT data were fit to human fully tryptic peptides by X!TANDEM, which led to the identification of 3,888 protein gene symbols represented by three or more peptides (n ≥ 3). The peptide counts to plasma proteins from experimental MS/MS spectra were corrected against 29 blank LC-ESI-MS/MS spectra and 30 million random MS/MS control spectra to yield 2,784 true positive proteins (n ≥ 3; q ≤ 0.01). Peptides identified by fragmenting ions with Gaussian heavy isotopes and hydrogen loss that were matched to known plasma proteins, such as albumin (ALB), were shown to be true positives and agreed with the peptide sequences identified in the monoisotopic peak. Accepting the ions from the monoisotopic peak alone (±0.1 Da) yielded only 382 plasma proteins (n ≥ 3; type I error q ≤ 0.01; type II error ∼86%). In contrast, accepting all ions within ±0.1 Da around the hydrogen loss, monoisotopic, and heavy isotopic peaks led to the identification of 963 proteins (n ≥ 3; q ≤ 0.01; type II error ∼60%). Using the power of the OIT to resolve the Gaussian peaks from heavy isotopes and hydrogen loss resulted in the identification of three times more proteins with high confidence and a much lower type II error than analyzing peptides from the monoisotopic peak alone. The resolving power of the OIT may be exploited to increase observation frequencies and provide greater proteomic coverage and statistical power in comparative proteomics studies.
- Open Access
- 22 October 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 697, 115694
Micro scale chromatography of human plasma proteins for nano LC-ESI-MS/MS
- 22 October 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 697, 115694
Open AccessMicro scale chromatography of human plasma proteins for nano LC-ESI-MS/MS
- Open Access
- 24 September 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (40) , 41343-41354
Trypsin Digestion Conditions of Human Plasma for Observation of Peptides and Proteins from Tandem Mass Spectrometry
Previous meta-analysis indicated that plasma or serum proteome groups using various experimental conditions detected different peptides from the same plasma proteins, which is strong evidence for the veracity of blood fluid LC-ESI-MS/MS but also evidences that the trypsin digestion step is a key source of variation in plasma proteomics. Agreement between different digestion conditions and MS/MS algorithms may serve as an independent confirmation of the validity of the LC-ESI-MS/MS analysis of plasma peptides. Plasma contains a high percentage of albumin held together by multiple disulfide bonds; hence, reduction and/or alkylation may greatly enhance the digestion efficiency of albumin. Plasma proteins were precipitated in 90% acetonitrile, collected over quaternary amine resin, and eluted in NaCl prior to digestion treatments. To determine the effect of trypsin digestion methods, the plasma proteins were digested in 600 mM urea and 5% acetonitrile with trypsin alone, or reduced with 2 mM DTT followed by trypsin, or DTT followed by 15 mM iodoacetamide and then trypsin. The resulting peptides were analyzed by LC-ESI-MS/MS with a linear quadrupole ion trap (LIT). The MS/MS spectra were directly fit to peptides by the X!TANDEM and SEQUEST algorithms. Blank noise injections served as the analytical control, and 30 million random MS/MS served as the statistical control. Digesting human plasma with DTT reduction, or reduction and alkylation, resulted in a dramatic increase in the number and observation frequency of albumin peptides. In contrast, digestion with trypsin alone suppressed the observation of albumin, and instead, many low abundance plasma and cellular proteins showed higher observation frequency. Digestion with trypsin alone increased the observation frequency of APOC1, ACAN, ATRN, CPB2, GP2, GPX3, HBA1, PAPD5, PKD1, and many cellular proteins. After correction against noise and random controls, SEQUEST showed good agreement with the true positive plasma proteins identified by X!TANDEM and resulted in an R-squared of 0.5238 with an F-statistic of 10,930 on 9,935 protein gene symbols with a p-value < 2.2e-16. Digestion of plasma with trypsin alone avoids the complete digestion of albumin and permits the enhanced detection of some other cellular proteins from plasma. Different digestion approaches were complimentary and together resulted in a more comprehensive plasma proteome. The protein FDR q-values, the modest effect of background and Monte Carlo correction, and the significant STRING analysis were all consistent with the high fidelity of the rigorous X!TANDEM algorithm. In contrast, SEQUEST required significant correction against noise and statistical controls and selection of high cross correlation (XCorr) scores to show good agreement with X!TANDEM. There was qualitative and quantitative agreement between plasma proteins digested without alkylation from the orbital ion trap (OIT) versus the LIT instrument that showed highly significant regression against the X!TANDEM OIT monoisotopic results, those from heavy isotopes and other masses from X!TANDEM, and with those from MaxQuant. There was significant qualitative and quantitative agreement between the complementary digestion conditions consistent with the good fidelity of plasma analysis by LC-ESI-MS/MS with a sensitive linear ion trap.
- 24 September 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (40) , 41343-41354
Open AccessTrypsin Digestion Conditions of Human Plasma for Observation of Peptides and Proteins from Tandem Mass Spectrometry
Previous meta-analysis indicated that plasma or serum proteome groups using various experimental conditions detected different peptides from the same plasma proteins, which is strong evidence for the veracity of blood fluid LC-ESI-MS/MS but also evidences that the trypsin digestion step is a key source of variation in plasma proteomics. Agreement between different digestion conditions and MS/MS algorithms may serve as an independent confirmation of the validity of the LC-ESI-MS/MS analysis of plasma peptides. Plasma contains a high percentage of albumin held together by multiple disulfide bonds; hence, reduction and/or alkylation may greatly enhance the digestion efficiency of albumin. Plasma proteins were precipitated in 90% acetonitrile, collected over quaternary amine resin, and eluted in NaCl prior to digestion treatments. To determine the effect of trypsin digestion methods, the plasma proteins were digested in 600 mM urea and 5% acetonitrile with trypsin alone, or reduced with 2 mM DTT followed by trypsin, or DTT followed by 15 mM iodoacetamide and then trypsin. The resulting peptides were analyzed by LC-ESI-MS/MS with a linear quadrupole ion trap (LIT). The MS/MS spectra were directly fit to peptides by the X!TANDEM and SEQUEST algorithms. Blank noise injections served as the analytical control, and 30 million random MS/MS served as the statistical control. Digesting human plasma with DTT reduction, or reduction and alkylation, resulted in a dramatic increase in the number and observation frequency of albumin peptides. In contrast, digestion with trypsin alone suppressed the observation of albumin, and instead, many low abundance plasma and cellular proteins showed higher observation frequency. Digestion with trypsin alone increased the observation frequency of APOC1, ACAN, ATRN, CPB2, GP2, GPX3, HBA1, PAPD5, PKD1, and many cellular proteins. After correction against noise and random controls, SEQUEST showed good agreement with the true positive plasma proteins identified by X!TANDEM and resulted in an R-squared of 0.5238 with an F-statistic of 10,930 on 9,935 protein gene symbols with a p-value < 2.2e-16. Digestion of plasma with trypsin alone avoids the complete digestion of albumin and permits the enhanced detection of some other cellular proteins from plasma. Different digestion approaches were complimentary and together resulted in a more comprehensive plasma proteome. The protein FDR q-values, the modest effect of background and Monte Carlo correction, and the significant STRING analysis were all consistent with the high fidelity of the rigorous X!TANDEM algorithm. In contrast, SEQUEST required significant correction against noise and statistical controls and selection of high cross correlation (XCorr) scores to show good agreement with X!TANDEM. There was qualitative and quantitative agreement between plasma proteins digested without alkylation from the orbital ion trap (OIT) versus the LIT instrument that showed highly significant regression against the X!TANDEM OIT monoisotopic results, those from heavy isotopes and other masses from X!TANDEM, and with those from MaxQuant. There was significant qualitative and quantitative agreement between the complementary digestion conditions consistent with the good fidelity of plasma analysis by LC-ESI-MS/MS with a sensitive linear ion trap.
- 8 March 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 689, 115497
Extraction of naturally occurring peptides versus the tryptic digestion of proteins from fetal versus adult bovine serum for LC-ESI-MS/MS
- 8 March 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 689, 115497
Extraction of naturally occurring peptides versus the tryptic digestion of proteins from fetal versus adult bovine serum for LC-ESI-MS/MS
- Open Access
- 8 April 2023
- Published by Springer Nature in Clinical Proteomics
- Vol. 20 (1) , 1-22
Mitochondria and cytochrome components released into the plasma of severe COVID-19 and ICU acute respiratory distress syndrome patients
Introduction: Proteomic analysis of human plasma by LC–ESI–MS/MS has discovered a limited number of new cellular protein biomarkers that may be confirmed by independent biochemical methods. Analysis of COVID-19 plasma has indicated the re-purposing of known biomarkers that might be used as prognostic markers of COVID-19 infection. However, multiple molecular approaches have previously indicated that the SARS-COV2 infection cycle is linked to the biology of mitochondria and that the response to infections may involve the action of heme containing oxidative enzymes. Methods: Human plasma from COVID-19 and ICU-ARDS was analyzed by classical analytical biochemistry techniques and classical frequency-based statistical approaches to look for prognostic markers of severe COVID-19 lung damage. Plasma proteins from COVID-19 and ICU-ARDS were identified and enumerated versus the controls of normal human plasma (NHP) by LC–ESI–MS/MS. The observation frequency of proteins detected in COVID-19 and ICU-ARDS patients were compared to normal human plasma, alongside random and noise MS/MS spectra controls, using the Chi Square (χ2) distribution. Results: PCR showed the presence of MT-ND1 DNA in the plasma of COVID-19, ICU-ARDS, as well as normal human plasma. Mitochondrial proteins such as MRPL, L2HGDH, ATP, CYB, CYTB, CYP, NDUF and others, were increased in COVID-19 and ICU-ARDS plasma. The apparent activity of the cytochrome components were tested alongside NHP by dot blotting on PVDF against a purified cytochrome c standard preparation for H2O2 dependent reaction with luminol as measured by enhanced chemiluminescence (ECL) that showed increased activity in COVID-19 and ICU-ARDS patients. Discussion: The results from PCR, LC–ESI–MS/MS of tryptic peptides, and cytochrome ECL assays confirmed that mitochondrial components were present in the plasma, in agreement with the established central role of the mitochondria in SARS-COV-2 biology. The cytochrome activity assay showed that there was the equivalent of at least nanogram amounts of cytochrome(s) in the plasma sample that should be clearly detectable by LC–ESI–MS/MS. The release of the luminol oxidase activity from cells into plasma forms the basis of a simple and rapid test for the severity of cell damage and lung injury in COVID-19 infection and ICU-ARDS. Graphical
- 8 April 2023
- Published by Springer Nature in Clinical Proteomics
- Vol. 20 (1) , 1-22
Open AccessMitochondria and cytochrome components released into the plasma of severe COVID-19 and ICU acute respiratory distress syndrome patients
Introduction: Proteomic analysis of human plasma by LC–ESI–MS/MS has discovered a limited number of new cellular protein biomarkers that may be confirmed by independent biochemical methods. Analysis of COVID-19 plasma has indicated the re-purposing of known biomarkers that might be used as prognostic markers of COVID-19 infection. However, multiple molecular approaches have previously indicated that the SARS-COV2 infection cycle is linked to the biology of mitochondria and that the response to infections may involve the action of heme containing oxidative enzymes. Methods: Human plasma from COVID-19 and ICU-ARDS was analyzed by classical analytical biochemistry techniques and classical frequency-based statistical approaches to look for prognostic markers of severe COVID-19 lung damage. Plasma proteins from COVID-19 and ICU-ARDS were identified and enumerated versus the controls of normal human plasma (NHP) by LC–ESI–MS/MS. The observation frequency of proteins detected in COVID-19 and ICU-ARDS patients were compared to normal human plasma, alongside random and noise MS/MS spectra controls, using the Chi Square (χ2) distribution. Results: PCR showed the presence of MT-ND1 DNA in the plasma of COVID-19, ICU-ARDS, as well as normal human plasma. Mitochondrial proteins such as MRPL, L2HGDH, ATP, CYB, CYTB, CYP, NDUF and others, were increased in COVID-19 and ICU-ARDS plasma. The apparent activity of the cytochrome components were tested alongside NHP by dot blotting on PVDF against a purified cytochrome c standard preparation for H2O2 dependent reaction with luminol as measured by enhanced chemiluminescence (ECL) that showed increased activity in COVID-19 and ICU-ARDS patients. Discussion: The results from PCR, LC–ESI–MS/MS of tryptic peptides, and cytochrome ECL assays confirmed that mitochondrial components were present in the plasma, in agreement with the established central role of the mitochondria in SARS-COV-2 biology. The cytochrome activity assay showed that there was the equivalent of at least nanogram amounts of cytochrome(s) in the plasma sample that should be clearly detectable by LC–ESI–MS/MS. The release of the luminol oxidase activity from cells into plasma forms the basis of a simple and rapid test for the severity of cell damage and lung injury in COVID-19 infection and ICU-ARDS. Graphical
- 12 August 2022
- Published by Elsevier in Analytical Biochemistry
- Vol. 655, 114845
LEDGF is a new growth factor in fetal serum
- 12 August 2022
- Published by Elsevier in Analytical Biochemistry
- Vol. 655, 114845
LEDGF is a new growth factor in fetal serum