Naohide Takeuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naohide Takeuchi has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Yasuharu Nakashima
Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Fukuoka 8128582, Japan
4 shared publications- Yoshitaka Nakanishi
Faculty of Advanced Science and Technology, Kumamoto University, Kumamoto, Japan
4 shared publications Hidehiko Higaki
Kyushu Sangyo University
3 shared publicationsHidehiko Yuge
Mizoguchi Orthopaed Hosp, Dept Orthopaed Surg, Fukuoka 8100001, Japan
3 shared publicationsNaoya Kozono
Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Fukuoka 8128582, Japan
3 shared publicationsTakahiro Senju
Sasebo Kyosai Hosp, Dept Orthopaed Surg, Nagasaki 8570879, Japan
3 shared publications
Latest Publications
- 5 January 2023
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 28 (6) , 1274-1278
Prevalence and predisposing factors of neuropathic pain in patients with rotator cuff tears
- 5 January 2023
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 28 (6) , 1274-1278
Prevalence and predisposing factors of neuropathic pain in patients with rotator cuff tears
- 4 February 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (5) , 1063-1071
Risk of penetration of the baseplate peg in reverse total shoulder arthroplasty for an Asian population
Purpose Baseplate positioning may affect clinical outcome after reverse total shoulder arthroplasty (RTSA). The aim of this study was to evaluate the risk of penetration of the baseplate peg in RTSA. Methods Forty-four patients with rotator cuff arthropathy or massive rotator cuff tears were included. Using their computed tomography data, ten insertion patterns of the baseplate pegs were simulated. First, in the axial plane, the baseplate was placed perpendicular to the Friedman axis (Friedman placement) and parallel to the glenoid surface (glenoid placement). Second, each of these placements were classified into the following groups: The baseplate peg was placed 2 mm anterior to the long axis of the glenoid (group A2), 1 mm anterior (group A1), on the long axis (group C0), 1 mm posterior (group P1), and 2 mm posterior (group P2). Cases in which the baseplate peg was within the scapular neck were defined as non-penetration, and the non-penetration rates among each group were evaluated and compared between sexes, and their relationship with patient height was evaluated. Results In both the Friedman and glenoid placements, the non-penetration rate was significantly higher in groups A2 (68.2% and 70.5%) and A1 (65.9% and 65.9%) compared with groups P1 (18.2% and 29.5%) and P2 (9.1% and 13.6%; p < 0.001) and in males than in females (p < 0.05). Furthermore, the non-penetration rate tended to be higher as the patient’s height increased. Conclusions It is recommended that the baseplate peg be placed anterior to the long axis of the glenoid.
- 4 February 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (5) , 1063-1071
Risk of penetration of the baseplate peg in reverse total shoulder arthroplasty for an Asian population
Purpose Baseplate positioning may affect clinical outcome after reverse total shoulder arthroplasty (RTSA). The aim of this study was to evaluate the risk of penetration of the baseplate peg in RTSA. Methods Forty-four patients with rotator cuff arthropathy or massive rotator cuff tears were included. Using their computed tomography data, ten insertion patterns of the baseplate pegs were simulated. First, in the axial plane, the baseplate was placed perpendicular to the Friedman axis (Friedman placement) and parallel to the glenoid surface (glenoid placement). Second, each of these placements were classified into the following groups: The baseplate peg was placed 2 mm anterior to the long axis of the glenoid (group A2), 1 mm anterior (group A1), on the long axis (group C0), 1 mm posterior (group P1), and 2 mm posterior (group P2). Cases in which the baseplate peg was within the scapular neck were defined as non-penetration, and the non-penetration rates among each group were evaluated and compared between sexes, and their relationship with patient height was evaluated. Results In both the Friedman and glenoid placements, the non-penetration rate was significantly higher in groups A2 (68.2% and 70.5%) and A1 (65.9% and 65.9%) compared with groups P1 (18.2% and 29.5%) and P2 (9.1% and 13.6%; p < 0.001) and in males than in females (p < 0.05). Furthermore, the non-penetration rate tended to be higher as the patient’s height increased. Conclusions It is recommended that the baseplate peg be placed anterior to the long axis of the glenoid.
- 18 January 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (8) , 2587-2594
Stump classification was correlated with retear in the suture‐bridge and double‐row repair techniques for arthroscopic rotator cuff repair
Purpose: The Stump classification is significantly correlated with a retear after arthroscopic rotator cuff repair. However, no study has evaluated whether or not the stump classification is correlated with retear in the suture‐bridge or double‐row repair techniques. The aim of this study was to evaluate the relationship between a retear and the stump classification in the suture‐bridge and double‐row repair techniques. Methods: Among 389 patients who underwent arthroscopic repairs of full‐thickness rotator cuff tears using suture‐bridge or double‐row repair techniques, 326 patients (median age 67.0 years; range 25–85) were included. There were 51 small, 172 medium, 83 large, and 20 massive tears. Two hundred forty patients were treated with the suture‐bridge technique, and 86 patients were treated with the double‐row technique. The following variables were analyzed: age, sex, the Cofield classification, anteroposterior and mediolateral tear size on preoperative MRI, global fatty degeneration index, and the stump classification. Cuff integrity was evaluated on magnetic resonance imaging at 6 months after surgery. The patients were divided into the intact and retear groups and the relationship between the variables and retear was evaluated by multivariate logistic regression analysis. Results: The overall retear rate was 10.1%. In the multivariate logistic regression analysis, the independent predictors of a retear were the stump classification type 3 (Odds ratio: 4.71, p = 0.0246), global fatty degeneration index (Odds ratio: 3.87, p = 0.0030), and anteroposterior tear size (Odds ratio: 1.07, p = 0.0077) in the suture bridge technique. In the double‐row technique, the independent predictors of retear were stump classification type 3 (Odds ratio: 7.82, p = 0.0348), and age (Odds ratio: 1.22, p = 0.0163). Conclusion: The stump classification was significantly correlated with retear in the suture‐bridge and double‐row repair technique. Stump classification type 3 was indicated to be an important risk factor for predicting retear. Level of evidence: III
- 18 January 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (8) , 2587-2594
Stump classification was correlated with retear in the suture‐bridge and double‐row repair techniques for arthroscopic rotator cuff repair
Purpose: The Stump classification is significantly correlated with a retear after arthroscopic rotator cuff repair. However, no study has evaluated whether or not the stump classification is correlated with retear in the suture‐bridge or double‐row repair techniques. The aim of this study was to evaluate the relationship between a retear and the stump classification in the suture‐bridge and double‐row repair techniques. Methods: Among 389 patients who underwent arthroscopic repairs of full‐thickness rotator cuff tears using suture‐bridge or double‐row repair techniques, 326 patients (median age 67.0 years; range 25–85) were included. There were 51 small, 172 medium, 83 large, and 20 massive tears. Two hundred forty patients were treated with the suture‐bridge technique, and 86 patients were treated with the double‐row technique. The following variables were analyzed: age, sex, the Cofield classification, anteroposterior and mediolateral tear size on preoperative MRI, global fatty degeneration index, and the stump classification. Cuff integrity was evaluated on magnetic resonance imaging at 6 months after surgery. The patients were divided into the intact and retear groups and the relationship between the variables and retear was evaluated by multivariate logistic regression analysis. Results: The overall retear rate was 10.1%. In the multivariate logistic regression analysis, the independent predictors of a retear were the stump classification type 3 (Odds ratio: 4.71, p = 0.0246), global fatty degeneration index (Odds ratio: 3.87, p = 0.0030), and anteroposterior tear size (Odds ratio: 1.07, p = 0.0077) in the suture bridge technique. In the double‐row technique, the independent predictors of retear were stump classification type 3 (Odds ratio: 7.82, p = 0.0348), and age (Odds ratio: 1.22, p = 0.0163). Conclusion: The stump classification was significantly correlated with retear in the suture‐bridge and double‐row repair technique. Stump classification type 3 was indicated to be an important risk factor for predicting retear. Level of evidence: III
- 1 March 2019
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 24 (2) , 258-262
Evaluation of humeral head cartilage using magnetic resonance imaging T1 rho mapping for patients with small-to-medium rotator cuff tears: A pilot study
- 1 March 2019
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 24 (2) , 258-262
Evaluation of humeral head cartilage using magnetic resonance imaging T1 rho mapping for patients with small-to-medium rotator cuff tears: A pilot study
- Open Access
- 11 January 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 9
Dynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears
No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
- 11 January 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 9
Open AccessDynamic kinematics of the glenohumeral joint in shoulders with rotator cuff tears
No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: − 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at − 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.
- 1 September 2017
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 56 (5) , 1025-1030
Management of Intra-Articular Calcaneal Fractures: Clinical Results of Reduction Technique Using a Bone Spreader
- 1 September 2017
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 56 (5) , 1025-1030
Management of Intra-Articular Calcaneal Fractures: Clinical Results of Reduction Technique Using a Bone Spreader
- Open Access
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _3P1-D02_1
3P1-D02 Comparison of Peripheral Suture Methods using Cyclic Loading in Flexor Tendon Repair(Medical Robotics and Mechatronics (2))
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _3P1-D02_1
Open Access3P1-D02 Comparison of Peripheral Suture Methods using Cyclic Loading in Flexor Tendon Repair(Medical Robotics and Mechatronics (2))
- Open Access
- 1 January 2014
- Published by Society of Biomechanisms Japan in Journal of the Society of Biomechanisms
- Vol. 38 (1) , 53-59
Evaluation of Suture Strength by Cyclic Loading in Flexor Tendon Repair
- 1 January 2014
- Published by Society of Biomechanisms Japan in Journal of the Society of Biomechanisms
- Vol. 38 (1) , 53-59
Open AccessEvaluation of Suture Strength by Cyclic Loading in Flexor Tendon Repair
- 1 May 2011
- Vol. 102 (5) , 185-94
The orientation of orthopaedic metallic devices relative to the frequency-encoding gradient affects susceptibility artifacts: an experiment using open MR imaging.
To evaluate the magnetic susceptibility artifacts associated with different frequency-encoding gradient directions for an angled cephalomedullary device of the proximal femur, and to determine the optimal extremity positioning for reducing artifacts using 0.4 T open MR imaging. Two different angular devices made of titanium alloy and stainless steel were used. The images were obtained with the frequency-encoding gradient parallel to the rod (Group R) and parallel to the lag screw (Group L). The device positioning was altered in order to obtain images with frequency-encoding gradient parallel to the rod and parallel to the lag screw. The artifact areas associated with the whole device and the lag screw were statistically evaluated. For both devices, the mean artifact area in Group L was significantly larger than that in Group R (p<0.05). However, the mean artifact area of the lag screw only in Group L was significantly smaller than that in Group R (p<0.05). Susceptibility artifacts for angled cephalomedullary devices can be minimized when the frequency-encoding gradient is parallel to the long axis of the regions of interest. Open MR imaging enables us to obtain the optimal orientation for minimizing susceptibility artifacts.
- 1 May 2011
- Vol. 102 (5) , 185-94
The orientation of orthopaedic metallic devices relative to the frequency-encoding gradient affects susceptibility artifacts: an experiment using open MR imaging.
To evaluate the magnetic susceptibility artifacts associated with different frequency-encoding gradient directions for an angled cephalomedullary device of the proximal femur, and to determine the optimal extremity positioning for reducing artifacts using 0.4 T open MR imaging. Two different angular devices made of titanium alloy and stainless steel were used. The images were obtained with the frequency-encoding gradient parallel to the rod (Group R) and parallel to the lag screw (Group L). The device positioning was altered in order to obtain images with frequency-encoding gradient parallel to the rod and parallel to the lag screw. The artifact areas associated with the whole device and the lag screw were statistically evaluated. For both devices, the mean artifact area in Group L was significantly larger than that in Group R (p<0.05). However, the mean artifact area of the lag screw only in Group L was significantly smaller than that in Group R (p<0.05). Susceptibility artifacts for angled cephalomedullary devices can be minimized when the frequency-encoding gradient is parallel to the long axis of the regions of interest. Open MR imaging enables us to obtain the optimal orientation for minimizing susceptibility artifacts.