HLHao Liang

Hao Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hao Liang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Hailu Xia

    Department of Anesthesia, Peking Union Medical College Hospital, Chinese Academy of Medical Science, 1 Shuaifuyuan, Dongcheng District, Beijing, 100730, China

    1 shared publication
  • Jie Yi

    Department of Anesthesiology, Peking Union Medical College Hospital, Beijing, China

    1 shared publication
  • Jing-Yan Wang

    Department of Otolaryngology, Affiliated Hospital of Hebei University, Baoding, China

    1 shared publication
  • Mei-Na Gao

    Department of Anesthesiology, Baoding No.1 Central Hospital, Baoding, China

    1 shared publication
  • Ruiyue Song

    Department of Anesthesia, Peking Union Medical College Hospital, Chinese Academy of Medical Science, 1 Shuaifuyuan, Dongcheng District, Beijing, 100730, China

    1 shared publication
  • Xin-Feng Shao

    Department of Anesthesiology, Baoding No.1 Central Hospital, Baoding, China

    1 shared publication

Latest Publications

  • Open Access

    Accuracy of improved zero heat flux core temperature monitoring in non-cardiac surgery for patients undergoing general anesthesia

    by Yan Liang, Jing-Yan Wang, Xin-Feng Shao, Ze-Guang Wang, Mei-Na Gao, Hao Liang

    Due to various factors such as anesthesia, the core body temperature of perioperative patients often fluctuates significantly. Ideal core temperature measurements are particularly needed during the perioperative period for early identification of hypothermia and malignant hyperthermia, and even to guide intraoperative temperature protection. This study aimed to evaluate the consistency of the optimized Zero-Heat-Flux (ZHF) thermometer with esophageal temperature monitoring under general anesthesia. Adult patients, classified as American Society of Anesthesiologists (ASA) I–III, who are scheduled for elective surgery will be enrolled in this study. Both esophageal and ZHF core temperature monitoring were measured simultaneously. The consistency and correlation between the two measurements were evaluated using Bland–Altman analysis, linear regression methods, and the percentage of differences within ± 0.5 °C. The sensitivity and specificity of the ZHF temperature in identifying hypothermia were further validated. Ninety patients with a total of 1035 pairs of measurements were analyzed. Bland–Altman analysis revealed a mean difference between ZHF temperature and esophageal temperature of 0.06 ± 0.26 °C, with 95% limits of agreement ranging from − 0.57 to 0.46 °C. 96.0% of the measurement differences were within ± 0.5 °C. The consistency correlation coefficient was 0.89 (95% CI 0.88–0.90). The sensitivity and specificity of ZHF temperature monitoring in diagnosing hypothermia were 0.86 and 0.91 respectively. The modified ZHF core temperature monitoring system demonstrates good accuracy and consistency with esophageal temperature monitoring during general anesthesia for surgery. ZHF temperature monitoring is highly reliable for diagnosing hypothermia, though further research is needed to evaluate its accuracy.


  • Open Access

    Maintaining intraoperative normothermia reduces blood loss in patients undergoing major operations: a pilot randomized controlled clinical trial

    by Jie Yi, Hao Liang, Ruiyue Song, Hailu Xia, Yuguang Huang

    Inadvertent intraoperative hypothermia (core temperature < 36 °C) is a common but preventable adverse event. This study aimed to determine whether active intraoperative warming reduced bleeding in patients undergoing major operations: open thoracic surgery and hip replacement surgery. The study was a pilot, prospective, parallel two-arm randomized controlled trial. Eligible patients were randomly allocated to two groups: passive warming (PW), with application of a cotton blanket (thermal insulation), or active warming (AW), with a forced-air warming system. The primary endpoint was intraoperative blood loss, and secondary endpoints were surgical-site infection, cardiovascular events, and length of stay in the post-anesthesia care unit, intensive care unit, and hospital. Sixty-two patients were enrolled. Forced-air active warming maintained intraoperative normothermia in all AW subjects, whereas intraoperative hypothermia occurred in 21/32 (71.8%) of PW patients (p = 0.000). The volume of blood loss was more in the PW group (682 ± 426 ml) than in the AW group (464 ± 324 ml) (p < 0.021), and the perioperative hemoglobin value declined more in the PW group (28.6 ± 17.5 g/L) than in the AW group (21.0 ± 9.9 g/L) (p = 0.045). However, there were no difference in other clinical outcomes between two groups. Intraoperative active warming is associated with less blood loss than passive warming in open thoracic and hip replacement operations in this pilot study. This trial was registered with Clinicaltrials.gov (Identifier: NCT02214524 ) on 27 August 2014.