Xinmai Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xinmai Yang has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Xueding Wang
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
14 shared publications - Yannis Mantas Paulus
Department of Ophthalmology, Wilmer Eye Institute, Johns Hopkins University, Baltimore, USA
13 shared publications Janggun Jo
Department of Biomedical Engineering University of Michigan Ann Arbor Michigan USA
5 shared publicationsRohit Singh
Institute for Bioengineering Research and Department of Mechanical Engineering University of Kansas Lawrence Kansas USA
5 shared publicationsXinyi Xie
Department of Ophthalmology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
5 shared publications- Mingyang Wang
University of Michigan, Ann Arbor, MI, USA
4 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 025065
The delayed-onset of inertial cavitation in tissue-mimicking agar phantom
Objective . Delayed-onset cavitation refers to inertial cavitation occurring in the middle of an applied ultrasound burst, rather than at its onset. In other words, the inertial cavitation threshold depends on the number of applied acoustic cycles. Understanding this phenomenon is important for improving the safety of biomedical ultrasound applications that utilize long ultrasound bursts, such as ultrasound stimulation. Although delayed-onset cavitation has been previously observed experimentally in agar-based tissue phantoms, its underlying mechanism has not been well understood. Approach. In this study, delayed-onset cavitation was first investigated in water and agar-based tissue phantoms. Then, a theoretical model was used to combine a viscoelastic bubble dynamics model with the rectified diffusion process to numerically demonstrate that delayed-onset cavitation is possible in agar-based tissue-mimicking phantom. Main result. Compared to cavitation in water, the increased viscoelasticity and existence of relatively large size cavitation nuclei in agar phantoms likely contribute to the delayed onset cavitation. Significance. The results underscore the need for further investigation of cycle-dependent inertial cavitation threshold criterion for biomedical ultrasound applications using long bursts in viscoelastic media.
- 1 April 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (2) , 025065
Open AccessThe delayed-onset of inertial cavitation in tissue-mimicking agar phantom
Objective . Delayed-onset cavitation refers to inertial cavitation occurring in the middle of an applied ultrasound burst, rather than at its onset. In other words, the inertial cavitation threshold depends on the number of applied acoustic cycles. Understanding this phenomenon is important for improving the safety of biomedical ultrasound applications that utilize long ultrasound bursts, such as ultrasound stimulation. Although delayed-onset cavitation has been previously observed experimentally in agar-based tissue phantoms, its underlying mechanism has not been well understood. Approach. In this study, delayed-onset cavitation was first investigated in water and agar-based tissue phantoms. Then, a theoretical model was used to combine a viscoelastic bubble dynamics model with the rectified diffusion process to numerically demonstrate that delayed-onset cavitation is possible in agar-based tissue-mimicking phantom. Main result. Compared to cavitation in water, the increased viscoelasticity and existence of relatively large size cavitation nuclei in agar phantoms likely contribute to the delayed onset cavitation. Significance. The results underscore the need for further investigation of cycle-dependent inertial cavitation threshold criterion for biomedical ultrasound applications using long bursts in viscoelastic media.
- Open Access
- 2 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 135-145
Photo-Mediated Ultrasound Therapy (PUT) for the Treatment of Deep Cutaneous Vasculature
Traditionally, pulsed dye laser (PDL) therapy has been used to treat cutaneous blood vessels in patients with port-wine stain (PWS) birthmarks. PDL therapy, however, has limited treatment depth, and frequently results in suboptimal therapeutic outcomes when used to treat deep cutaneous blood vessels. We have developed photo-mediated ultrasound therapy (PUT), a hybrid cavitation-based anti-vascular technology combining nanosecond light pulses with ultrasound bursts and demonstrated its great potential in treating deep cutaneous vessels. This study explored the feasibility of PUT as an alternative to traditional PDL therapy for deep cutaneous vascular treatment in a clinically relevant chicken wattle model. PUT was employed to induce cavitation in blood vessels by using different light fluence and ultrasound pressure combinations. Theoretical modeling and in vitro experiments were first conducted to validate and optimize parameters for PUT treatment targeting deep vasculature. PUT treatments were then performed in a chicken wattle model using an experimental setup, and outcomes were assessed by using polarized dermoscope, optical coherence tomography angiography (OCT-A) imaging, and histopathological analyses. The results demonstrated that PUT can effectively penetrate the entire thickness of chicken wattle tissue, which is about 3 mm, and significantly reduce blood vessel density by 45.20% with a light fluence 10–100 times less than the fluence used in traditional PDL therapy. OCT-A imaging showed that local blood perfusion was significantly reduced, and the reduced blood perfusion persisted for at least 7 days post-treatment in the treated areas. Histopathological analyses based on H&E, CD31, and Russell-Movat Pentachrome (RMP) stains confirmed effective and selective vascular damage through the entire thickness of chicken wattle without causing collateral thermal damage. In conclusion, PUT can effectively eliminate blood vessels with a treatment depth up to 3 mm whereas the 3 mm treatment depth demonstrated in this study was only limited by the chicken wattle model. By leveraging the deep tissue penetration of ultrasound and the flexibility in treatment parameter selection, PUT can effectively treat deep cutaneous vasculature using reduced light fluence and thereby minimize collateral damage in skin tissues. Thus, PUT holds great potential for treatment of cutaneous vascular anomalies such as PWS.
- 2 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 135-145
Open AccessPhoto-Mediated Ultrasound Therapy (PUT) for the Treatment of Deep Cutaneous Vasculature
Traditionally, pulsed dye laser (PDL) therapy has been used to treat cutaneous blood vessels in patients with port-wine stain (PWS) birthmarks. PDL therapy, however, has limited treatment depth, and frequently results in suboptimal therapeutic outcomes when used to treat deep cutaneous blood vessels. We have developed photo-mediated ultrasound therapy (PUT), a hybrid cavitation-based anti-vascular technology combining nanosecond light pulses with ultrasound bursts and demonstrated its great potential in treating deep cutaneous vessels. This study explored the feasibility of PUT as an alternative to traditional PDL therapy for deep cutaneous vascular treatment in a clinically relevant chicken wattle model. PUT was employed to induce cavitation in blood vessels by using different light fluence and ultrasound pressure combinations. Theoretical modeling and in vitro experiments were first conducted to validate and optimize parameters for PUT treatment targeting deep vasculature. PUT treatments were then performed in a chicken wattle model using an experimental setup, and outcomes were assessed by using polarized dermoscope, optical coherence tomography angiography (OCT-A) imaging, and histopathological analyses. The results demonstrated that PUT can effectively penetrate the entire thickness of chicken wattle tissue, which is about 3 mm, and significantly reduce blood vessel density by 45.20% with a light fluence 10–100 times less than the fluence used in traditional PDL therapy. OCT-A imaging showed that local blood perfusion was significantly reduced, and the reduced blood perfusion persisted for at least 7 days post-treatment in the treated areas. Histopathological analyses based on H&E, CD31, and Russell-Movat Pentachrome (RMP) stains confirmed effective and selective vascular damage through the entire thickness of chicken wattle without causing collateral thermal damage. In conclusion, PUT can effectively eliminate blood vessels with a treatment depth up to 3 mm whereas the 3 mm treatment depth demonstrated in this study was only limited by the chicken wattle model. By leveraging the deep tissue penetration of ultrasound and the flexibility in treatment parameter selection, PUT can effectively treat deep cutaneous vasculature using reduced light fluence and thereby minimize collateral damage in skin tissues. Thus, PUT holds great potential for treatment of cutaneous vascular anomalies such as PWS.
- Open Access
- 18 July 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (10) , 1789-1796
An In Vivo Study on the Feasibility of Catheter-Assisted Pulsed Focused Ultrasound Ablation of Atherosclerotic Plaques
- 18 July 2025
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (10) , 1789-1796
Open AccessAn In Vivo Study on the Feasibility of Catheter-Assisted Pulsed Focused Ultrasound Ablation of Atherosclerotic Plaques
- Open Access
- 18 September 2024
- Published by Frontiers Media SA in Frontiers in Acoustics
- Vol. 2, 1456606
Pulsed focused ultrasound ablation assisted by a surface modified catheter for thrombolysis: a feasibility study
Interventional procedures for the recanalization of blood vessels to treat deep vein thrombosis carry a high risk of vessel wall injuries or hemorrhaging. Focused ultrasound (FUS) has been used to non-invasively break down blood clots that occlude the vessels in both in vitro and in vivo studies. Previous studies have either used thrombolytic drugs or ultrasound contrast agents (e.g., microbubbles) in combination with FUS. Several studies have applied very high peak-negative-pressures (PNP) during FUS treatment to achieve successful thrombolysis without the use of contrast agents. In the current study, we demonstrated that cavitation activity could be significantly enhanced by placing a nitinol wire, whose surface was roughed by laser etching, in the focal region of a FUS field. We demonstrated in vitro in a mock thrombosis that the thrombolysis efficacy of a 500 kHz FUS transducer was significantly enhanced using a surface-etched nitinol wire as compared to an unetched nitinol wire, whereas FUS-alone at the same pressure level did not result in any thrombolysis. These results suggest that a surface modified nitinol catheter exposed to FUS can result in intense cavitation activities leading to enhanced thrombolysis without the use of additional pharmacological or contrast agents.
- 18 September 2024
- Published by Frontiers Media SA in Frontiers in Acoustics
- Vol. 2, 1456606
Open AccessPulsed focused ultrasound ablation assisted by a surface modified catheter for thrombolysis: a feasibility study
Interventional procedures for the recanalization of blood vessels to treat deep vein thrombosis carry a high risk of vessel wall injuries or hemorrhaging. Focused ultrasound (FUS) has been used to non-invasively break down blood clots that occlude the vessels in both in vitro and in vivo studies. Previous studies have either used thrombolytic drugs or ultrasound contrast agents (e.g., microbubbles) in combination with FUS. Several studies have applied very high peak-negative-pressures (PNP) during FUS treatment to achieve successful thrombolysis without the use of contrast agents. In the current study, we demonstrated that cavitation activity could be significantly enhanced by placing a nitinol wire, whose surface was roughed by laser etching, in the focal region of a FUS field. We demonstrated in vitro in a mock thrombosis that the thrombolysis efficacy of a 500 kHz FUS transducer was significantly enhanced using a surface-etched nitinol wire as compared to an unetched nitinol wire, whereas FUS-alone at the same pressure level did not result in any thrombolysis. These results suggest that a surface modified nitinol catheter exposed to FUS can result in intense cavitation activities leading to enhanced thrombolysis without the use of additional pharmacological or contrast agents.
- Open Access
- 7 August 2024
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 249, 10096
Ultrasound-assisted laser therapy for selective removal of melanoma cells
The current study explores the potential of ultrasound-assisted laser therapy (USaLT) to selectively destroy melanoma cells. The technology was tested on an ex vivo melanoma model, which was established by growing melanoma cells in chicken breast tissue. Ultrasound-only and laser-only treatments were used as control groups. USaLT was able to effectively destroy melanoma cells and selectively remove 66.41% of melanoma cells in the ex vivo tumor model when an ultrasound peak negative pressure of 2 MPa was concurrently applied with a laser fluence of 28 mJ/cm2 at 532 nm optical wavelength for 5 min. The therapeutic efficiency was further improved with the use of a higher laser fluence, and the treatment depth was improved to 3.5 mm with the use of 1,064 nm laser light at a fluence of 150 mJ/cm2. None of the laser-only and ultrasound-only treatments were able to remove any melanoma cells. The treatment outcome was validated with histological analyses and photoacoustic imaging. This study opens the possibility of USaLT for melanoma that is currently treated by laser therapy, but at a much lower laser fluence level, hence improving the safety potential of laser therapy.
- 7 August 2024
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 249, 10096
Open AccessUltrasound-assisted laser therapy for selective removal of melanoma cells
The current study explores the potential of ultrasound-assisted laser therapy (USaLT) to selectively destroy melanoma cells. The technology was tested on an ex vivo melanoma model, which was established by growing melanoma cells in chicken breast tissue. Ultrasound-only and laser-only treatments were used as control groups. USaLT was able to effectively destroy melanoma cells and selectively remove 66.41% of melanoma cells in the ex vivo tumor model when an ultrasound peak negative pressure of 2 MPa was concurrently applied with a laser fluence of 28 mJ/cm2 at 532 nm optical wavelength for 5 min. The therapeutic efficiency was further improved with the use of a higher laser fluence, and the treatment depth was improved to 3.5 mm with the use of 1,064 nm laser light at a fluence of 150 mJ/cm2. None of the laser-only and ultrasound-only treatments were able to remove any melanoma cells. The treatment outcome was validated with histological analyses and photoacoustic imaging. This study opens the possibility of USaLT for melanoma that is currently treated by laser therapy, but at a much lower laser fluence level, hence improving the safety potential of laser therapy.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2473-2482
Real-Time Cavitation Monitoring During Optical Coherence Tomography Guided Photo-Mediated Ultrasound Therapy of the Retina
Objective: Photo-mediated ultrasound therapy (PUT) is a novel antivascular therapeutic modality based on cavitation-induced bioeffects. During PUT, synergistic combinations of laser pulses and ultrasound bursts are used to remove the targeted microvessels selectively and precisely without harming nearby tissue. In the current study, an integrated system combining PUT and spectral domain optical coherence tomography (SD-OCT) was developed, where the SD-OCT system was used to guide PUT by detecting cavitation in real time in the retina of the eye. Method: We first examined the capability of SD-OCT in detecting cavitation on a vascular-mimicking phantom and compared the results with those from a passive cavitation detector. The performance of the integrated system in treatment of choroidal microvessels was then evaluated in rabbit eyes in vivo. Results: During the in vivo PUT experiments, several biomarkers at the subretinal layer in the rabbit eye were identified on OCT images. The findings indicate that, by evaluating biomarkers of treatment effect, real-time SD-OCT monitoring could help to avoid micro-hemorrhage, which is a potential major side effect. Conclusion: Real-time OCT monitoring can thus improve the safety and efficiency of PUT in removing the retinal and choroidal microvasculature.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2473-2482
Real-Time Cavitation Monitoring During Optical Coherence Tomography Guided Photo-Mediated Ultrasound Therapy of the Retina
Objective: Photo-mediated ultrasound therapy (PUT) is a novel antivascular therapeutic modality based on cavitation-induced bioeffects. During PUT, synergistic combinations of laser pulses and ultrasound bursts are used to remove the targeted microvessels selectively and precisely without harming nearby tissue. In the current study, an integrated system combining PUT and spectral domain optical coherence tomography (SD-OCT) was developed, where the SD-OCT system was used to guide PUT by detecting cavitation in real time in the retina of the eye. Method: We first examined the capability of SD-OCT in detecting cavitation on a vascular-mimicking phantom and compared the results with those from a passive cavitation detector. The performance of the integrated system in treatment of choroidal microvessels was then evaluated in rabbit eyes in vivo. Results: During the in vivo PUT experiments, several biomarkers at the subretinal layer in the rabbit eye were identified on OCT images. The findings indicate that, by evaluating biomarkers of treatment effect, real-time SD-OCT monitoring could help to avoid micro-hemorrhage, which is a potential major side effect. Conclusion: Real-time OCT monitoring can thus improve the safety and efficiency of PUT in removing the retinal and choroidal microvasculature.
- 8 May 2023
- Published by Wiley in Medical Physics
- Vol. 50 (12) , 7349-7358
Recanalize ureteral stents with focused ultrasound
BackgroundMaintaining ureteral patency is imperative to preventing renal injury and systemic infection. Ureteral stents are small conduits connecting the kidney and the bladder. They have been widely used to treat ureteral obstructions and ureteral leaks. The most problematic and frequent stent-associated complication is stent encrustation. This occurs when mineral crystals (e.g. calcium, oxalate, phosphorus, struvite) are deposited onto the surface and internal lumen of the stent. Encrustation can lead to the obstruction of a stent and increases risk of systemic infection. As a result, ureteral stents need to be replaced typically every 2-3 months. PurposeIn this study, we present a non-invasive, high-intensity focused ultrasound (HIFU)-based technique to recanalize obstructed stents. By taking advantage of the mechanical force produced by a HIFU beam, including acoustic radiation force, acoustic streaming, and cavitation, HIFU can break up encrustations, clearing the stent of obstruction. MethodsThe ureteral stents for this study were obtained from patients undergoing ureteral stent removal. Under the guidance of ultrasound imaging, the encrustation in the stents were located, and then targeted by HIFU at frequencies of 0.25 and 1 MHz. The duty cycle of HIFU was 10%, and the HIFU burst repetition rate was 1 Hz, while the HIFU amplitude was varied to find the threshold pressure that would displace encrustations. The treatment duration was limited at 2 min (or 120 shots from HIFU). The treatments were carried out in two different orientations (parallel and perpendicular) of the ureteral stent with respect to the HIFU beam. For each setting, five treatments were conducted for a maximum duration of 2 min. During the entire treatment, an ultrasound imaging system was used to monitor the movement of encrustations inside the stent. The peak negative HIFU pressures needed to move the encrustations inside the stent was recorded for quantitative analysis. ResultsOur results demonstrated that at both 0.25 and 1 MHz ultrasound frequencies, obstructed stents could be recanalized. At 0.25 MHz, the needed average peak negative pressure was 0.52 MPa in parallel orientation and 0.42 MPa in perpendicular orientation. At 1 MHz, the needed average peak negative pressure was 1.10 MPa in parallel orientation and 1.15 MPa in perpendicular orientation ConclusionsThis first in-vitro study has demonstrated the feasibility of non-invasive HIFU to recanalize ureteral stents. This technology has a potential to reduce the need for ureteral stent exchange.
- 8 May 2023
- Published by Wiley in Medical Physics
- Vol. 50 (12) , 7349-7358
Recanalize ureteral stents with focused ultrasound
BackgroundMaintaining ureteral patency is imperative to preventing renal injury and systemic infection. Ureteral stents are small conduits connecting the kidney and the bladder. They have been widely used to treat ureteral obstructions and ureteral leaks. The most problematic and frequent stent-associated complication is stent encrustation. This occurs when mineral crystals (e.g. calcium, oxalate, phosphorus, struvite) are deposited onto the surface and internal lumen of the stent. Encrustation can lead to the obstruction of a stent and increases risk of systemic infection. As a result, ureteral stents need to be replaced typically every 2-3 months. PurposeIn this study, we present a non-invasive, high-intensity focused ultrasound (HIFU)-based technique to recanalize obstructed stents. By taking advantage of the mechanical force produced by a HIFU beam, including acoustic radiation force, acoustic streaming, and cavitation, HIFU can break up encrustations, clearing the stent of obstruction. MethodsThe ureteral stents for this study were obtained from patients undergoing ureteral stent removal. Under the guidance of ultrasound imaging, the encrustation in the stents were located, and then targeted by HIFU at frequencies of 0.25 and 1 MHz. The duty cycle of HIFU was 10%, and the HIFU burst repetition rate was 1 Hz, while the HIFU amplitude was varied to find the threshold pressure that would displace encrustations. The treatment duration was limited at 2 min (or 120 shots from HIFU). The treatments were carried out in two different orientations (parallel and perpendicular) of the ureteral stent with respect to the HIFU beam. For each setting, five treatments were conducted for a maximum duration of 2 min. During the entire treatment, an ultrasound imaging system was used to monitor the movement of encrustations inside the stent. The peak negative HIFU pressures needed to move the encrustations inside the stent was recorded for quantitative analysis. ResultsOur results demonstrated that at both 0.25 and 1 MHz ultrasound frequencies, obstructed stents could be recanalized. At 0.25 MHz, the needed average peak negative pressure was 0.52 MPa in parallel orientation and 0.42 MPa in perpendicular orientation. At 1 MHz, the needed average peak negative pressure was 1.10 MPa in parallel orientation and 1.15 MPa in perpendicular orientation ConclusionsThis first in-vitro study has demonstrated the feasibility of non-invasive HIFU to recanalize ureteral stents. This technology has a potential to reduce the need for ureteral stent exchange.
- Open Access
- 17 April 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3661-3670
Choroidal neovascularization removal with photo‐mediated ultrasound therapy
Background: Age-related macular degeneration (AMD) is a major cause of irreversible central vision loss. The main reason for lost vision due to AMD is choroidal neovascularization (CNV). In the clinic, current treatments for CNV include photodynamic therapy, laser photocoagulation, and anti-vascular endothelial growth factor (VEGF) therapy. Purpose: This study evaluates a novel treatment technique combining synchronized nanosecond laser pulses and ultrasound bursts, namely photo-mediated ultrasound therapy (PUT) as a potential treatment method for CNV, for its efficacy and safety in the treatment of CNV via the experiments in a clinically-relevant rabbit model in vivo. Methods: CNV was created by subretinal injection of Matrigel and vascular endothelial growth factor (M&V) in 10 New Zealand white rabbits. Six rabbits were used in the PUT group. In the control groups, two rabbits were treated by laser-only, and two rabbits were treated by ultrasound-only. The treatment efficacy was evaluated through fundus photography and fluorescein angiography (FA) longitudinally for up to 4 weeks. Rabbits were sacrificed for histopathology 3 months after treatment to examine the safety of PUT. Results: The fluorescein leakage on FA was quantified to longitudinally evaluate treatment outcome. Compared with baseline, the relative intensity index was reduced by 26.57% +/- 8.66% at 3 days after treatment, 27.24% +/- 6.21% at 1 week after treatment, 27.79% +/- 2.61% at 2 weeks after treatment, and 32.12% +/- 3.23% at 4 weeks after treatment, all with a statistically significant difference of p < 0.01. The comparison between the relative intensity indexes from the two control groups (laser-only treatment and ultrasound-only treatment) did not show any statistically significant difference at all time points. Safety evaluation at 3 months with histopathology demonstrated that the PUT did not result in morphologic changes to the neurosensory retina. Conclusions: This study introduces PUT for the first time for the treatment of CNV. The results demonstrated good efficacy and safety of PUT to treat CNV in a clinically-relevant rabbit model. With a single session of treatment, PUT can safely reduce the leakage of CNV for at least 1 month after treatment.
- 17 April 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3661-3670
Open AccessChoroidal neovascularization removal with photo‐mediated ultrasound therapy
Background: Age-related macular degeneration (AMD) is a major cause of irreversible central vision loss. The main reason for lost vision due to AMD is choroidal neovascularization (CNV). In the clinic, current treatments for CNV include photodynamic therapy, laser photocoagulation, and anti-vascular endothelial growth factor (VEGF) therapy. Purpose: This study evaluates a novel treatment technique combining synchronized nanosecond laser pulses and ultrasound bursts, namely photo-mediated ultrasound therapy (PUT) as a potential treatment method for CNV, for its efficacy and safety in the treatment of CNV via the experiments in a clinically-relevant rabbit model in vivo. Methods: CNV was created by subretinal injection of Matrigel and vascular endothelial growth factor (M&V) in 10 New Zealand white rabbits. Six rabbits were used in the PUT group. In the control groups, two rabbits were treated by laser-only, and two rabbits were treated by ultrasound-only. The treatment efficacy was evaluated through fundus photography and fluorescein angiography (FA) longitudinally for up to 4 weeks. Rabbits were sacrificed for histopathology 3 months after treatment to examine the safety of PUT. Results: The fluorescein leakage on FA was quantified to longitudinally evaluate treatment outcome. Compared with baseline, the relative intensity index was reduced by 26.57% +/- 8.66% at 3 days after treatment, 27.24% +/- 6.21% at 1 week after treatment, 27.79% +/- 2.61% at 2 weeks after treatment, and 32.12% +/- 3.23% at 4 weeks after treatment, all with a statistically significant difference of p < 0.01. The comparison between the relative intensity indexes from the two control groups (laser-only treatment and ultrasound-only treatment) did not show any statistically significant difference at all time points. Safety evaluation at 3 months with histopathology demonstrated that the PUT did not result in morphologic changes to the neurosensory retina. Conclusions: This study introduces PUT for the first time for the treatment of CNV. The results demonstrated good efficacy and safety of PUT to treat CNV in a clinically-relevant rabbit model. With a single session of treatment, PUT can safely reduce the leakage of CNV for at least 1 month after treatment.
- 21 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (5) , 055007
A feasibility study on removing lipid deposition in atherosclerotic plaques with ultrasound-assisted laser ablation
Objective . Atherosclerosis is the buildup of fats, cholesterol, and other substances on the inner walls of arteries. It can affect arteries of heart, brain, arms, legs, pelvis and kidney, resulting in ischemic heart disease, carotid artery disease, peripheral artery disease and chronic kidney disease. Laser-based treatment techniques like laser atherectomy can be used to treat many common atherosclerostic diseases. However, the use of laser-based treatment remains limited due to the high risk of complications and low efficiency in removing atherosclerostic plaques as compared with other treatment methods. In this study, we developed a technology that used high intensity focused ultrasound to assist laser treatment in the removal of the lipid core of atherosclerotic plaques. Approach . The fundamental mechanism to disrupt atherosclerostic plaque was to enhance the mechanical effect of cavitation during laser/ultrasound therapy. To promote cavitation, spatiotemporally synchronized ultrasound bursts of 2% duty cycle at 0.5 MHz and nanosecond laser pulses at 532 nm wavelength were used. Experiments were first performed on pig belly fat samples to titrate ultrasound and laser parameters. Then, experiments were conducted on human plaque samples, where the lipid depositions of the plaques were targeted. Main results . Our results showed that fat tissue could be removed with an ultrasound peak negative pressure (PNP) of 2.45 MPa and a laser radiant exposure as low as 3.2 mJ mm −2 . The lipid depositions on the atherosclerostic plaques were removed with laser radiant exposure of 16 mJ mm −2 in synchronizing with an ultrasound PNP of 5.4 MPa. During all the experiments, laser-only and ultrasound-only control treatments at the same energy levels were not effective in removing the lipid. Significance . The results demonstrated that the addition of ultrasound could effectively reduce the needed laser power for atherosclerotic plaque removal, which will potentially improve treatment safety and efficiency of current laser therapies.
- 21 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (5) , 055007
A feasibility study on removing lipid deposition in atherosclerotic plaques with ultrasound-assisted laser ablation
Objective . Atherosclerosis is the buildup of fats, cholesterol, and other substances on the inner walls of arteries. It can affect arteries of heart, brain, arms, legs, pelvis and kidney, resulting in ischemic heart disease, carotid artery disease, peripheral artery disease and chronic kidney disease. Laser-based treatment techniques like laser atherectomy can be used to treat many common atherosclerostic diseases. However, the use of laser-based treatment remains limited due to the high risk of complications and low efficiency in removing atherosclerostic plaques as compared with other treatment methods. In this study, we developed a technology that used high intensity focused ultrasound to assist laser treatment in the removal of the lipid core of atherosclerotic plaques. Approach . The fundamental mechanism to disrupt atherosclerostic plaque was to enhance the mechanical effect of cavitation during laser/ultrasound therapy. To promote cavitation, spatiotemporally synchronized ultrasound bursts of 2% duty cycle at 0.5 MHz and nanosecond laser pulses at 532 nm wavelength were used. Experiments were first performed on pig belly fat samples to titrate ultrasound and laser parameters. Then, experiments were conducted on human plaque samples, where the lipid depositions of the plaques were targeted. Main results . Our results showed that fat tissue could be removed with an ultrasound peak negative pressure (PNP) of 2.45 MPa and a laser radiant exposure as low as 3.2 mJ mm −2 . The lipid depositions on the atherosclerostic plaques were removed with laser radiant exposure of 16 mJ mm −2 in synchronizing with an ultrasound PNP of 5.4 MPa. During all the experiments, laser-only and ultrasound-only control treatments at the same energy levels were not effective in removing the lipid. Significance . The results demonstrated that the addition of ultrasound could effectively reduce the needed laser power for atherosclerotic plaque removal, which will potentially improve treatment safety and efficiency of current laser therapies.
- Open Access
- 1 April 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (4) , 045020
A 3D finite element model to study the cavitation induced stresses on blood–vessel wall during the ultrasound-only phase of photo-mediated ultrasound therapy
Photo-mediated ultrasound therapy (PUT) is a novel technique utilizing synchronized ultrasound and laser to generate enhanced cavitation inside blood vessels. The enhanced cavitation inside blood vessels induces bio-effects, which can result in the removal of micro-vessels and the reduction in local blood perfusion. These bio-effects have the potential to treat neovascularization diseases in the eye, such as age-related macular degeneration and diabetic retinopathy. Currently, PUT is in the preclinical stage, and various PUT studies on in vivo rabbit eye models have shown successful removal of micro-vessels. PUT is completely non-invasive and particle-free as opposed to current clinical treatments such as anti-vascular endothelial growth factor therapy and photodynamic therapy, and it precisely removes micro-vessels without damaging the surrounding tissue, unlike laser photocoagulation therapy. The stresses produced by oscillating bubbles during PUT are responsible for the induced bio-effects in blood vessels. In our previous work, stresses induced during the first phase of PUT due to combined ultrasound and laser irradiation were studied using a 2D model. In this work, stresses induced during the third or last phase of PUT due to ultrasound alone were studied using a 3D finite element method-based numerical model. The results showed that the circumferential and shear stress increased as the bubble moves from the center of the vessel toward the vessel wall with more than a 16 times increase in shear stress from 1.848 to 31.060 kPa as compared to only a 4 times increase in circumferential stress from 211 to 906 kPa for a 2 µm bubble placed inside a 10 µm vessel on the application of 1 MHz ultrasound frequency and 130 kPa amplitude. In addition, the stresses decreased as the bubble was placed in smaller sized vessels with a larger decrease in circumferential stress. The changes in shear stress were found to be more dependent on the bubble–vessel wall distance, and the changes in circumferential stress were more dependent on the bubble oscillation amplitude. Moreover, the bubble shape changed to an ellipsoidal with a higher oscillation amplitude in the vessel’s axial direction as it was moved closer to the vessel wall, and the bubble oscillation amplitude decreased drastically as it was placed in vessels of a smaller size.
- 1 April 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (4) , 045020
Open AccessA 3D finite element model to study the cavitation induced stresses on blood–vessel wall during the ultrasound-only phase of photo-mediated ultrasound therapy
Photo-mediated ultrasound therapy (PUT) is a novel technique utilizing synchronized ultrasound and laser to generate enhanced cavitation inside blood vessels. The enhanced cavitation inside blood vessels induces bio-effects, which can result in the removal of micro-vessels and the reduction in local blood perfusion. These bio-effects have the potential to treat neovascularization diseases in the eye, such as age-related macular degeneration and diabetic retinopathy. Currently, PUT is in the preclinical stage, and various PUT studies on in vivo rabbit eye models have shown successful removal of micro-vessels. PUT is completely non-invasive and particle-free as opposed to current clinical treatments such as anti-vascular endothelial growth factor therapy and photodynamic therapy, and it precisely removes micro-vessels without damaging the surrounding tissue, unlike laser photocoagulation therapy. The stresses produced by oscillating bubbles during PUT are responsible for the induced bio-effects in blood vessels. In our previous work, stresses induced during the first phase of PUT due to combined ultrasound and laser irradiation were studied using a 2D model. In this work, stresses induced during the third or last phase of PUT due to ultrasound alone were studied using a 3D finite element method-based numerical model. The results showed that the circumferential and shear stress increased as the bubble moves from the center of the vessel toward the vessel wall with more than a 16 times increase in shear stress from 1.848 to 31.060 kPa as compared to only a 4 times increase in circumferential stress from 211 to 906 kPa for a 2 µm bubble placed inside a 10 µm vessel on the application of 1 MHz ultrasound frequency and 130 kPa amplitude. In addition, the stresses decreased as the bubble was placed in smaller sized vessels with a larger decrease in circumferential stress. The changes in shear stress were found to be more dependent on the bubble–vessel wall distance, and the changes in circumferential stress were more dependent on the bubble oscillation amplitude. Moreover, the bubble shape changed to an ellipsoidal with a higher oscillation amplitude in the vessel’s axial direction as it was moved closer to the vessel wall, and the bubble oscillation amplitude decreased drastically as it was placed in vessels of a smaller size.