Jihye Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jihye Kim has a total of 178 co-authors. Here are the top co-authors by number of shared publications:
- Sang-Woo Kim
Department of Materials Science and Engineering Center for Human‐oriented Triboelectric Energy Harvesting Yonsei University Seoul Republic of Korea
9 shared publications - Hanjun Ryu
Department of Advanced Materials Engineering, Chung-Ang University, Anseong-si 17546, Gyeonggi-do, Republic of Korea
7 shared publications - Hong-Joon Yoon
Department of Semiconductor Engineering, Gachon University, Seongnam 13120, Republic of Korea
6 shared publications - Aik Choon Tan
Huntsman Cancer Institute, University of Utah, Salt Lake City, Utah, USA
5 shared publications - Sung Soo Kwak
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208
5 shared publications Brittelle E. Kessler
3 shared publications
Latest Publications
- 8 October 2026
- Published by Elsevier in Nano Energy
- Vol. 159
Graphene oxide-assisted self-assembly of diphenylalanine nanostructures for enhanced piezoelectric nanogenerators
- 8 October 2026
- Published by Elsevier in Nano Energy
- Vol. 159
Graphene oxide-assisted self-assembly of diphenylalanine nanostructures for enhanced piezoelectric nanogenerators
- 30 September 2026
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 35 (5) , 458-468
Wearable Bioimpedance Sensors for Human Healthcare
- 30 September 2026
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 35 (5) , 458-468
Wearable Bioimpedance Sensors for Human Healthcare
- Open Access
- 26 January 2026
- Published by Wiley in Advanced Therapeutics
- Vol. 9 (1)
Bioresorbable Systems in Healthcare for Transient Sensing and Therapeutic Interventions
Transient bioresorbable systems operate only during the clinically indicated window and then dissolve into benign products, eliminating explantation. By matching device presence to the days to weeks period after surgery or intervention, they reduce exposure to anesthesia, reentry trauma, and risks of infection, bleeding, and wound dehiscence, while shortening recovery and lowering costs. This review surveys sensing and therapeutic platforms that use bioresorbable polymers, metals, and silicon based materials to provide structural, conductive, dielectric, and semiconducting functions. Physical sensing of pressure and temperature employs capacitive, piezoelectric, triboelectric, and resistive transduction, together with passive inductor capacitor resonant readouts. Chemical sensing of potential of hydrogen leverages fluorescence based optics, radio frequency hydrogel resonators, and ultrasound readable shape adaptive materials. Therapeutic examples include radio frequency or ultrasound powered electrical stimulation for nerve regeneration or analgesia, temporary cardiac pacing, and localized drug delivery via wireless heating reservoirs or sealed on demand valves. We present a design map linking material chemistry, thickness and geometry, and encapsulation to service lifetime, supported by accelerated soak tests and diffusion and Arrhenius models of defect driven leakage. We also offer cross modal rules and checklists for translational readiness, including standardized reporting and validation from models to living organisms.
- 26 January 2026
- Published by Wiley in Advanced Therapeutics
- Vol. 9 (1)
Open AccessBioresorbable Systems in Healthcare for Transient Sensing and Therapeutic Interventions
Transient bioresorbable systems operate only during the clinically indicated window and then dissolve into benign products, eliminating explantation. By matching device presence to the days to weeks period after surgery or intervention, they reduce exposure to anesthesia, reentry trauma, and risks of infection, bleeding, and wound dehiscence, while shortening recovery and lowering costs. This review surveys sensing and therapeutic platforms that use bioresorbable polymers, metals, and silicon based materials to provide structural, conductive, dielectric, and semiconducting functions. Physical sensing of pressure and temperature employs capacitive, piezoelectric, triboelectric, and resistive transduction, together with passive inductor capacitor resonant readouts. Chemical sensing of potential of hydrogen leverages fluorescence based optics, radio frequency hydrogel resonators, and ultrasound readable shape adaptive materials. Therapeutic examples include radio frequency or ultrasound powered electrical stimulation for nerve regeneration or analgesia, temporary cardiac pacing, and localized drug delivery via wireless heating reservoirs or sealed on demand valves. We present a design map linking material chemistry, thickness and geometry, and encapsulation to service lifetime, supported by accelerated soak tests and diffusion and Arrhenius models of defect driven leakage. We also offer cross modal rules and checklists for translational readiness, including standardized reporting and validation from models to living organisms.
- 14 January 2026
- Published by Springer Nature in Transactions on Electrical and Electronic Materials
- Vol. 27 (2) , 210-216
Thermometry-Based Bioelectronics: from Cardiovascular Monitoring to Immunological Diagnostics
- 14 January 2026
- Published by Springer Nature in Transactions on Electrical and Electronic Materials
- Vol. 27 (2) , 210-216
Thermometry-Based Bioelectronics: from Cardiovascular Monitoring to Immunological Diagnostics
- Open Access
- 14 October 2025
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 34 (5) , 513-519
Wireless Bioelectronics for Bladder Function Monitoring
- 14 October 2025
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 34 (5) , 513-519
Open AccessWireless Bioelectronics for Bladder Function Monitoring
- Open Access
- 28 March 2024
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 121 (14)
A wireless, implantable bioelectronic system for monitoring urinary bladder function following surgical recovery
Partial cystectomy procedures for urinary bladder–related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients. Here, we introduce a fully bladder-implantable platform that allows for continuous, real-time measurements of changes in mechanical strain associated with bladder filling and emptying via wireless telemetry, including a wireless bioresorbable strain gauge validated in a benchtop partial cystectomy model. We demonstrate that this system can reproducibly measure real-time changes in a rodent model up to 30 d postimplantation with minimal foreign body response. Studies in a nonhuman primate partial cystectomy model demonstrate concordance of pressure measurements up to 8 wk compared with traditional UDS. These results suggest that our system can be used as a suitable alternative to UDS for long-term postoperative bladder recovery monitoring.
- 28 March 2024
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 121 (14)
Open AccessA wireless, implantable bioelectronic system for monitoring urinary bladder function following surgical recovery
Partial cystectomy procedures for urinary bladder–related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients. Here, we introduce a fully bladder-implantable platform that allows for continuous, real-time measurements of changes in mechanical strain associated with bladder filling and emptying via wireless telemetry, including a wireless bioresorbable strain gauge validated in a benchtop partial cystectomy model. We demonstrate that this system can reproducibly measure real-time changes in a rodent model up to 30 d postimplantation with minimal foreign body response. Studies in a nonhuman primate partial cystectomy model demonstrate concordance of pressure measurements up to 8 wk compared with traditional UDS. These results suggest that our system can be used as a suitable alternative to UDS for long-term postoperative bladder recovery monitoring.
- 24 January 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (5)
Triboelectric Nanogenerators for Battery‐Free Wireless Sensor System Using Multi‐Degree of Freedom Vibration
In a daily environment, several vibration energies have low amplitude and broad range of frequencies, and it is crucial to harvest them efficiently in a single triboelectric nanogenerator (TENG). Here, a multi‐degree of freedom (DOF) vibration system is coupled with TENG to make several resonant frequencies in a single device. When the number of DOF increases in the system, the number of resonant frequencies also increases. These resonant frequencies are calculated by MATLAB software using the masses and spring constant of DOF vibration system. With the masses of 20 g and the spring constant of 82.712 N m−1, it is found that 1‐DOF has one resonant frequency (20.47 Hz), 2‐DOF has two resonant frequencies (12.63 and 33.17 Hz), and 3‐DOF has three resonant frequencies (9.12, 25.55, and 36.87 Hz). At each resonant frequency, the displacement of all weight layers increases due to the constructive interference of resonance, resulting in higher output than other frequencies at the frequency sweep experiment. In addition, the magnitude and phase of output signals obtained in friction regions are evaluated through COMSOL simulation. A self‐powered wireless sensor module with 3‐DOF TENGs to detect the humidity/temperature and transmit the data every 30 min by harvesting vibration energy is demonstrated.
- 24 January 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (5)
Triboelectric Nanogenerators for Battery‐Free Wireless Sensor System Using Multi‐Degree of Freedom Vibration
In a daily environment, several vibration energies have low amplitude and broad range of frequencies, and it is crucial to harvest them efficiently in a single triboelectric nanogenerator (TENG). Here, a multi‐degree of freedom (DOF) vibration system is coupled with TENG to make several resonant frequencies in a single device. When the number of DOF increases in the system, the number of resonant frequencies also increases. These resonant frequencies are calculated by MATLAB software using the masses and spring constant of DOF vibration system. With the masses of 20 g and the spring constant of 82.712 N m−1, it is found that 1‐DOF has one resonant frequency (20.47 Hz), 2‐DOF has two resonant frequencies (12.63 and 33.17 Hz), and 3‐DOF has three resonant frequencies (9.12, 25.55, and 36.87 Hz). At each resonant frequency, the displacement of all weight layers increases due to the constructive interference of resonance, resulting in higher output than other frequencies at the frequency sweep experiment. In addition, the magnitude and phase of output signals obtained in friction regions are evaluated through COMSOL simulation. A self‐powered wireless sensor module with 3‐DOF TENGs to detect the humidity/temperature and transmit the data every 30 min by harvesting vibration energy is demonstrated.
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Supplemental Table 1 from A Genome-Wide Loss-of-Function Screen Identifies SLC26A2 as a Novel Mediator of TRAIL Resistance
Supplemental Table 1: Significantly enriched pathways from GIANT analysis
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplemental Table 1 from A Genome-Wide Loss-of-Function Screen Identifies SLC26A2 as a Novel Mediator of TRAIL Resistance
Supplemental Table 1: Significantly enriched pathways from GIANT analysis
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Figure S3. Increased co-immunoprecipitation of B-Raf and c-Raf upon 5μM treatment with dasatinib in thyroid cancer cell lines. from The Mitogen-Activated Protein Kinase Pathway Facilitates Resistance to the Src Inhibitor Dasatinib in Thyroid Cancer
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessFigure S3. Increased co-immunoprecipitation of B-Raf and c-Raf upon 5μM treatment with dasatinib in thyroid cancer cell lines. from The Mitogen-Activated Protein Kinase Pathway Facilitates Resistance to the Src Inhibitor Dasatinib in Thyroid Cancer
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Figure S6. Synergistic inhibition of thyroid cancer cell growth to dasatinib when combined with MEK 1/2 Inhibition. from The Mitogen-Activated Protein Kinase Pathway Facilitates Resistance to the Src Inhibitor Dasatinib in Thyroid Cancer
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessFigure S6. Synergistic inhibition of thyroid cancer cell growth to dasatinib when combined with MEK 1/2 Inhibition. from The Mitogen-Activated Protein Kinase Pathway Facilitates Resistance to the Src Inhibitor Dasatinib in Thyroid Cancer