Kiang-Teck Jerry Yeo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kiang-Teck Jerry Yeo has a total of 155 co-authors. Here are the top co-authors by number of shared publications:
Clarence W Chan
Department of Pathology, Section of Clinical Chemistry, University of Chicago , Chicago, IL
6 shared publications- Mark J. Ratain
Committee on Clinical Pharmacology and Pharmacogenomics, University of Chicago, Chicago, IL
5 shared publications Xin Yi
Department of Pathology and Genomic Medicine, Weill Cornell Medical College , New York, NY , USA
5 shared publications- Larry K. House
Center for Personalized Therapeutics The University of Chicago Chicago Illinois USA
4 shared publications - Peter H. O’ Donnell
Center for Personalized Therapeutics The University of Chicago Chicago Illinois USA
4 shared publications Angel D Baldwin
Section of Clinical Chemistry, The University of Chicago Medicine , Chicago, IL
3 shared publications
Latest Publications
- Open Access
- 8 April 2026
- Published by Wiley in Clinical and Translational Science
- Vol. 19 (4) , e70537
Evaluating Perceived Value of Pharmacogenomic Testing After a Personalized Therapeutics Clinic Consultation
Pharmacogenomics (PGx) offers patients personalized treatment by guiding medication selection and dosing based on their genetic profiles. However, widespread clinical implementation remains limited, in part due to patient and provider concerns about cost and willingness to pay (WTP). This study evaluated whether an outpatient clinical consultation that educates patients on their PGx results influences their WTP for PGx testing. As part of the PROTECT‐Rx trial at the University of Chicago, high‐risk patients received free PGx testing and a virtual consultation at the Personalized Therapeutics Clinic (PTC). Patients completed pre‐ and post‐visit surveys assessing PGx knowledge and WTP. Of 129 patients who had completed a PTC visit as of 1/2025, 76 completed both the PTC visit and surveys. WTP for PGx testing increased significantly from 68% pre‐visit to 83% post‐visit ( p = 0.029). After controlling for social vulnerability, patients who had at least one cautionary or high‐risk PGx result were nearly 3 times more likely to report higher willingness‐to‐pay (OR 2.76, p = 0.037). A single PGx consultation with review of personal results significantly increases patients' WTP for testing, particularly among those with actionable PGx results. Understanding individual risk and the relevance of PGx enhances perceived value, suggesting that patient education is an important component in the broader adoption of pharmacogenomic testing.
- 8 April 2026
- Published by Wiley in Clinical and Translational Science
- Vol. 19 (4) , e70537
Open AccessEvaluating Perceived Value of Pharmacogenomic Testing After a Personalized Therapeutics Clinic Consultation
Pharmacogenomics (PGx) offers patients personalized treatment by guiding medication selection and dosing based on their genetic profiles. However, widespread clinical implementation remains limited, in part due to patient and provider concerns about cost and willingness to pay (WTP). This study evaluated whether an outpatient clinical consultation that educates patients on their PGx results influences their WTP for PGx testing. As part of the PROTECT‐Rx trial at the University of Chicago, high‐risk patients received free PGx testing and a virtual consultation at the Personalized Therapeutics Clinic (PTC). Patients completed pre‐ and post‐visit surveys assessing PGx knowledge and WTP. Of 129 patients who had completed a PTC visit as of 1/2025, 76 completed both the PTC visit and surveys. WTP for PGx testing increased significantly from 68% pre‐visit to 83% post‐visit ( p = 0.029). After controlling for social vulnerability, patients who had at least one cautionary or high‐risk PGx result were nearly 3 times more likely to report higher willingness‐to‐pay (OR 2.76, p = 0.037). A single PGx consultation with review of personal results significantly increases patients' WTP for testing, particularly among those with actionable PGx results. Understanding individual risk and the relevance of PGx enhances perceived value, suggesting that patient education is an important component in the broader adoption of pharmacogenomic testing.
- Open Access
- 22 August 2025
- Published by Wiley in Clinical Pharmacology & Therapeutics
- Vol. 119 (1) , 109-119
Results of the ACCOuNT Trial: A Multi‐Institutional Prospective Pharmacogenomics Implementation Trial for African American Inpatients
Pharmacogenomics implementation efforts have increased over the last decade, but no published prospective pharmacogenomics trials have formally evaluated utility in underrepresented populations. We present final results from the ACCOuNT trial, a multi‐institutional prospective study [NCT03225820] in which African American inpatients were genotyped and pharmacogenomic results made available via an integrated, scalable pharmacogenomics clinical decision support (PGx CDS) system to guide prescribing. We hypothesized that PGx CDS utilization would improve genomically concordant prescribing during inpatient admissions. We recruited 531 patients, of which 187 were readmitted (60.4% female, median age = 55 [range: 19–88], median readmissions/patient = 2 [range: 1–17]), resulting in 518 evaluable admissions during which the effect of available pharmacogenomic results was measured. In 50% of admissions, care teams utilized PGx CDS. 12% of inpatient prescriptions had pharmacogenomic annotations, with only 3.6% pharmacogenomically associated with increased caution (“discordant”); no PGx high‐risk medications were prescribed. PGx CDS use by provider teams did not decrease genomically discordant prescribing (3.9% vs. 3.3% without PGx CDS use, P = 0.53). Nevertheless, inpatient care teams repeatedly consulted PGx CDS ostensibly to affirm genomically concordant prescriptions, as 48% of all admissions and 91% of discharges included pharmacogenomically annotated medications, mostly genomically concordant. Notably, timing of PGx CDS utilization correlated tightly with prescribing timing (correlation coefficient = 0.84, P < 0.05). In the first results of a multi‐institutional, prospective pharmacogenomics trial focused on underrepresented patients, we found the relevance of currently actionable pharmacogenomics information for guiding inpatient prescribing to be modest; but observed frequent use of concordant pharmacogenomics to affirm prescribing.
- 22 August 2025
- Published by Wiley in Clinical Pharmacology & Therapeutics
- Vol. 119 (1) , 109-119
Open AccessResults of the ACCOuNT Trial: A Multi‐Institutional Prospective Pharmacogenomics Implementation Trial for African American Inpatients
Pharmacogenomics implementation efforts have increased over the last decade, but no published prospective pharmacogenomics trials have formally evaluated utility in underrepresented populations. We present final results from the ACCOuNT trial, a multi‐institutional prospective study [NCT03225820] in which African American inpatients were genotyped and pharmacogenomic results made available via an integrated, scalable pharmacogenomics clinical decision support (PGx CDS) system to guide prescribing. We hypothesized that PGx CDS utilization would improve genomically concordant prescribing during inpatient admissions. We recruited 531 patients, of which 187 were readmitted (60.4% female, median age = 55 [range: 19–88], median readmissions/patient = 2 [range: 1–17]), resulting in 518 evaluable admissions during which the effect of available pharmacogenomic results was measured. In 50% of admissions, care teams utilized PGx CDS. 12% of inpatient prescriptions had pharmacogenomic annotations, with only 3.6% pharmacogenomically associated with increased caution (“discordant”); no PGx high‐risk medications were prescribed. PGx CDS use by provider teams did not decrease genomically discordant prescribing (3.9% vs. 3.3% without PGx CDS use, P = 0.53). Nevertheless, inpatient care teams repeatedly consulted PGx CDS ostensibly to affirm genomically concordant prescriptions, as 48% of all admissions and 91% of discharges included pharmacogenomically annotated medications, mostly genomically concordant. Notably, timing of PGx CDS utilization correlated tightly with prescribing timing (correlation coefficient = 0.84, P < 0.05). In the first results of a multi‐institutional, prospective pharmacogenomics trial focused on underrepresented patients, we found the relevance of currently actionable pharmacogenomics information for guiding inpatient prescribing to be modest; but observed frequent use of concordant pharmacogenomics to affirm prescribing.
- Open Access
- 27 June 2025
- Published by Wiley in Clinical Pharmacology & Therapeutics
- Vol. 118 (4) , 906-916
Impact of First‐of‐Its‐Kind Patient‐Facing Pharmacogenetics Tool on Dosing Decisions and Treatment Outcomes
Germline pharmacogenetics (PGx) is increasingly used to tailor medication selection/dosing. However, existing systems primarily communicate PGx results to providers, limiting direct patient engagement. To address this, we developed YourPGx Oncology, an innovative patient‐facing portal that delivers multi‐gene PGx results (CYP2D6, UGT1A1, DPYD) through 33 unique, patient‐friendly summaries. The utility of this tool was prospectively evaluated in an oncology population, where these pharmacogenes impact high‐stakes treatments. Patients enrolled in the PhOCus study (NCT04541381) participated in single‐session evaluations of the tool in‐person or via videoconference, with a pharmacist available for questions and administering pre‐ and post‐surveys that assessed educational impact. Each patient viewed their own previously obtained PGx results. Of 190 eligible patients, 70 responded to solicitations via email, phone, and in‐person, of whom 51 (73%) completed an observed session and completed surveys. Patients spent a median of 13.4 minutes (range 8.1–21.0) navigating YourPGx Oncology. After portal interaction, patients' ability to identify individual efficacy and safety estimates for chemotherapies and pain medications significantly improved, with the proportion accurately recognizing PGx‐informed drug efficacy likelihoods rising from 32% to 72% (Odds Ratio [OR] = 5.8 for the shift from discordant to concordant efficacy knowledge, P < 0.001), and PGx‐related toxicity recognition increasing from 31% to 57% (OR = 3.2, P = 0.01). Our findings show that a customized patient‐facing PGx results portal enhances patient understanding of individual medication efficacy and toxicity likelihoods, highlighting the potential key role of direct‐to‐patient PGx tools to facilitate optimized treatment‐informed care and promote genetically guided shared decision‐making.
- 27 June 2025
- Published by Wiley in Clinical Pharmacology & Therapeutics
- Vol. 118 (4) , 906-916
Open AccessImpact of First‐of‐Its‐Kind Patient‐Facing Pharmacogenetics Tool on Dosing Decisions and Treatment Outcomes
Germline pharmacogenetics (PGx) is increasingly used to tailor medication selection/dosing. However, existing systems primarily communicate PGx results to providers, limiting direct patient engagement. To address this, we developed YourPGx Oncology, an innovative patient‐facing portal that delivers multi‐gene PGx results (CYP2D6, UGT1A1, DPYD) through 33 unique, patient‐friendly summaries. The utility of this tool was prospectively evaluated in an oncology population, where these pharmacogenes impact high‐stakes treatments. Patients enrolled in the PhOCus study (NCT04541381) participated in single‐session evaluations of the tool in‐person or via videoconference, with a pharmacist available for questions and administering pre‐ and post‐surveys that assessed educational impact. Each patient viewed their own previously obtained PGx results. Of 190 eligible patients, 70 responded to solicitations via email, phone, and in‐person, of whom 51 (73%) completed an observed session and completed surveys. Patients spent a median of 13.4 minutes (range 8.1–21.0) navigating YourPGx Oncology. After portal interaction, patients' ability to identify individual efficacy and safety estimates for chemotherapies and pain medications significantly improved, with the proportion accurately recognizing PGx‐informed drug efficacy likelihoods rising from 32% to 72% (Odds Ratio [OR] = 5.8 for the shift from discordant to concordant efficacy knowledge, P < 0.001), and PGx‐related toxicity recognition increasing from 31% to 57% (OR = 3.2, P = 0.01). Our findings show that a customized patient‐facing PGx results portal enhances patient understanding of individual medication efficacy and toxicity likelihoods, highlighting the potential key role of direct‐to‐patient PGx tools to facilitate optimized treatment‐informed care and promote genetically guided shared decision‐making.
- 8 May 2025
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 164 (2) , 200-206
Impact of PlGF immunoassay imprecision on preeclampsia risk assessment with the sFlt-1 to PlGF ratio
Objective: The US Food and Drug Administration recently approved the ratio of soluble FMS-like tyrosine kinase 1 (sFlt-1) to placental growth factor (PlGF) using the Thermo Fisher Scientific B·R·A·H·M·S KRYPTOR autoanalyzer—the first preeclampsia marker used for clinical testing. We evaluated the analytical precision of the sFlt-1 and PlGF assays, focusing on the effects of PlGF imprecision on the sFlt-1 to PlGF ratio interpretation and clinical reliability for preeclampsia risk assessment. Methods: We measured sFlt-1 and PlGF on the KRYPTOR instrument using a homogeneous sandwich fluoroimmunoassay. Between-day precision was assessed using 3 levels of commercial quality control (QC) materials and analyzed over 3 months. In all, 180 samples obtained from 161 hospitalized pregnant women were analyzed to assess the relationship between PlGF levels and the sFlt-1 to PlGF ratio. Results: The sFlt-1 assay demonstrated good precision (coefficient of variation (s/x̄) × 100 [CV] = approximately 3.0%) across all QC levels, while the PlGF assay exhibited higher imprecision, particularly at low QC levels (CV = 7.7%-11.3%). Long-term QC monitoring revealed a downward drift in PlGF values, with improved stability after reagent lot changes. Despite higher imprecision at lower PlGF levels (23.1-34.7 ng/L), the clinical interpretation of the sFlt-1 to PlGF ratio remained robust because low PlGF consistently correlated with ratios well above the critical cutoff of 40. Conclusions: Despite the suboptimal precision observed at low QC levels and potential drifts in PlGF results, the sFlt-1 to PlGF ratio remains a reliable tool for preeclampsia risk assessment. This study highlights the need for critical evaluation of analytical performance beyond FDA approval and the importance of assessing the potential impact of assay imprecision on patient care for individual biomarkers.
- 8 May 2025
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 164 (2) , 200-206
Impact of PlGF immunoassay imprecision on preeclampsia risk assessment with the sFlt-1 to PlGF ratio
Objective: The US Food and Drug Administration recently approved the ratio of soluble FMS-like tyrosine kinase 1 (sFlt-1) to placental growth factor (PlGF) using the Thermo Fisher Scientific B·R·A·H·M·S KRYPTOR autoanalyzer—the first preeclampsia marker used for clinical testing. We evaluated the analytical precision of the sFlt-1 and PlGF assays, focusing on the effects of PlGF imprecision on the sFlt-1 to PlGF ratio interpretation and clinical reliability for preeclampsia risk assessment. Methods: We measured sFlt-1 and PlGF on the KRYPTOR instrument using a homogeneous sandwich fluoroimmunoassay. Between-day precision was assessed using 3 levels of commercial quality control (QC) materials and analyzed over 3 months. In all, 180 samples obtained from 161 hospitalized pregnant women were analyzed to assess the relationship between PlGF levels and the sFlt-1 to PlGF ratio. Results: The sFlt-1 assay demonstrated good precision (coefficient of variation (s/x̄) × 100 [CV] = approximately 3.0%) across all QC levels, while the PlGF assay exhibited higher imprecision, particularly at low QC levels (CV = 7.7%-11.3%). Long-term QC monitoring revealed a downward drift in PlGF values, with improved stability after reagent lot changes. Despite higher imprecision at lower PlGF levels (23.1-34.7 ng/L), the clinical interpretation of the sFlt-1 to PlGF ratio remained robust because low PlGF consistently correlated with ratios well above the critical cutoff of 40. Conclusions: Despite the suboptimal precision observed at low QC levels and potential drifts in PlGF results, the sFlt-1 to PlGF ratio remains a reliable tool for preeclampsia risk assessment. This study highlights the need for critical evaluation of analytical performance beyond FDA approval and the importance of assessing the potential impact of assay imprecision on patient care for individual biomarkers.
- Open Access
Fecal Metabolite Quantitation for Rapid Assessment of the Gut Microbiome
The intestinal microbiome is composed of myriad microbial species that produce metabolites that impact host health. While loss of bacterial species and beneficial metabolites from the fecal microbiome is associated with development of a range of diseases and medical complications, there are currently no diagnostic tests that rapidly identify individuals with microbiome deficiencies. Reduced concentrations of fecal butyrate and deoxycholic acid are associated with adverse clinical outcomes and result from the loss of a subset of health-associated bacterial species. We present a rapid diagnostic test based on 3-nitrophenylhydrazine derivatization and ultrahigh-performance liquid chromatography-mass spectrometry that measures fecal butyrate and deoxycholic acid concentrations as markers of microbiome function. A matrix-matched calibration curve was developed using a simulated fecal mixture to optimize accuracy and facilitate adherence to clinical laboratory regulations. The assay showed an analytical measurement range from 4.3–3030.1 µM (LLOQ = 9.75 µM) for butyrate and from 0.9– 64.9 µM (LLOQ = 0.9 µM) for deoxycholic acid. Precision demonstrated a coefficient of variation <15% at all QC levels tested. The assay can be performed in under an hour from extraction to provision of quantitative results, enabling the rapid identification of patients with defective microbiome function.
Open AccessFecal Metabolite Quantitation for Rapid Assessment of the Gut Microbiome
The intestinal microbiome is composed of myriad microbial species that produce metabolites that impact host health. While loss of bacterial species and beneficial metabolites from the fecal microbiome is associated with development of a range of diseases and medical complications, there are currently no diagnostic tests that rapidly identify individuals with microbiome deficiencies. Reduced concentrations of fecal butyrate and deoxycholic acid are associated with adverse clinical outcomes and result from the loss of a subset of health-associated bacterial species. We present a rapid diagnostic test based on 3-nitrophenylhydrazine derivatization and ultrahigh-performance liquid chromatography-mass spectrometry that measures fecal butyrate and deoxycholic acid concentrations as markers of microbiome function. A matrix-matched calibration curve was developed using a simulated fecal mixture to optimize accuracy and facilitate adherence to clinical laboratory regulations. The assay showed an analytical measurement range from 4.3–3030.1 µM (LLOQ = 9.75 µM) for butyrate and from 0.9– 64.9 µM (LLOQ = 0.9 µM) for deoxycholic acid. Precision demonstrated a coefficient of variation <15% at all QC levels tested. The assay can be performed in under an hour from extraction to provision of quantitative results, enabling the rapid identification of patients with defective microbiome function.
- Open Access
- 1 December 2024
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 17, 4187-4196
Catalyzing Pharmacogenomic Analysis for Informing Pain Treatment (C-PAIN): A Randomized Trial of Preemptive CYP2D6 Genotyping in Cancer Palliative Care
Cancer patients frequently suffer from pain, often managed with opioids. However, undertreated pain remains a significant concern. Opioid effectiveness varies due to genetic differences in how individuals metabolize some of these medications. While prior research suggests promise in tailoring opioid prescriptions based on CYP2D6 genetic makeup, its application in cancer pain management remains limited. This study investigates the potential benefits of preemptive CYP2D6 genotyping for cancer patients initiating opioid therapy, focusing on codeine, tramadol, and hydrocodone, whose efficacy is demonstrably impacted by CYP2D6 variations. This is a randomized, prospective study to evaluate the effects of preemptive pharmacogenomic (PGx) testing on opioid dosing decisions/selections and composite pain score in oncology patients. Patients with metastatic solid tumors for whom near-future opioid therapy is anticipated will be randomized to PGx and control arms, stratified by the presence or absence of bony metastases and history of opioid use. In the PGx arm, patients will be preemptively tested using a panel of pharmacogenomic genetic variants, and providers will receive opioid dosing guidance via an electronic medical record-embedded clinical decision support tool. In the control arm, pain prescribing will occur per standard of care without genotype information. The primary study outcome will be composite pain intensity during the first 45 days after an index opioid prescription for codeine, tramadol, or hydrocodone. Safety will be assessed by comparing opioid-related adverse event rates between the two study arms. Secondary outcomes will include rates of hospitalization/emergency room visits, cumulative morphine equivalents received, and type of first opioid prescribed.
- 1 December 2024
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 17, 4187-4196
Open AccessCatalyzing Pharmacogenomic Analysis for Informing Pain Treatment (C-PAIN): A Randomized Trial of Preemptive CYP2D6 Genotyping in Cancer Palliative Care
Cancer patients frequently suffer from pain, often managed with opioids. However, undertreated pain remains a significant concern. Opioid effectiveness varies due to genetic differences in how individuals metabolize some of these medications. While prior research suggests promise in tailoring opioid prescriptions based on CYP2D6 genetic makeup, its application in cancer pain management remains limited. This study investigates the potential benefits of preemptive CYP2D6 genotyping for cancer patients initiating opioid therapy, focusing on codeine, tramadol, and hydrocodone, whose efficacy is demonstrably impacted by CYP2D6 variations. This is a randomized, prospective study to evaluate the effects of preemptive pharmacogenomic (PGx) testing on opioid dosing decisions/selections and composite pain score in oncology patients. Patients with metastatic solid tumors for whom near-future opioid therapy is anticipated will be randomized to PGx and control arms, stratified by the presence or absence of bony metastases and history of opioid use. In the PGx arm, patients will be preemptively tested using a panel of pharmacogenomic genetic variants, and providers will receive opioid dosing guidance via an electronic medical record-embedded clinical decision support tool. In the control arm, pain prescribing will occur per standard of care without genotype information. The primary study outcome will be composite pain intensity during the first 45 days after an index opioid prescription for codeine, tramadol, or hydrocodone. Safety will be assessed by comparing opioid-related adverse event rates between the two study arms. Secondary outcomes will include rates of hospitalization/emergency room visits, cumulative morphine equivalents received, and type of first opioid prescribed.
- 30 September 2023
- Published by Taylor & Francis in Critical Reviews in Clinical Laboratory Sciences
- Vol. 61 (2) , 89-106
Implementation of pharmacogenomics testing for precision medicine
Great strides have been made in the past decade to lower barriers to clinical pharmacogenomics implementation. Nevertheless, PGx consultation prior to prescribing therapeutics is not yet mainstream. This review addresses the current climate surrounding PGx implementation, focusing primarily on strategies for implementation at academic institutions, particularly at The University of Chicago, and provides an up-to-date guide of resources supporting the development of PGx programs. Remaining challenges and recent strategies for overcoming these challenges to implementation are discussed.
- 30 September 2023
- Published by Taylor & Francis in Critical Reviews in Clinical Laboratory Sciences
- Vol. 61 (2) , 89-106
Implementation of pharmacogenomics testing for precision medicine
Great strides have been made in the past decade to lower barriers to clinical pharmacogenomics implementation. Nevertheless, PGx consultation prior to prescribing therapeutics is not yet mainstream. This review addresses the current climate surrounding PGx implementation, focusing primarily on strategies for implementation at academic institutions, particularly at The University of Chicago, and provides an up-to-date guide of resources supporting the development of PGx programs. Remaining challenges and recent strategies for overcoming these challenges to implementation are discussed.
- 19 September 2023
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 161 (1) , 97-106
Is the automated Elecsys tacrolimus assay on the Roche cobas e 602 analyzer an acceptable replacement for a liquid chromatography–tandem mass spectrometry–based assay?
This study evaluated the suitability and accuracy of the automated Roche Elecsys tacrolimus electrochemiluminescence immunoassay (ECLIA) by comparing it with a current laboratory-developed test by liquid chromatography–tandem mass spectrometry (LC-MS/MS). The tacrolimus ECLIA was evaluated for precision, linearity, interference, and postextraction stability. Accuracy was compared with LC-MS/MS. The tacrolimus ECLIA assay is precise, exhibits a measuring range of 0.75 to 30 ng/mL, and is tolerant of significant interferences (plasma indices: hemolysis r2 = 0.97; Sy/x = 0.94; n = 43) and an absolute mean (SD) bias of 2.2 (1.7) ng/mL. Postextraction studies confirmed that samples were stable for up to 30 minutes under routine laboratory conditions. The 2 major challenges for implementation of the tacrolimus ECLIA assay are the postextraction sample stability and the significant proportional bias observed compared with the LC-MS/MS reference method. The 30-minute window for analysis of extracted samples is a practical challenge to the routine workflow of the core laboratory. In addition, disagreement between the immunoassay and LC-MS/MS methods can lead to discordant clinical interpretations and ultimately affect patient care.
- 19 September 2023
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 161 (1) , 97-106
Is the automated Elecsys tacrolimus assay on the Roche cobas e 602 analyzer an acceptable replacement for a liquid chromatography–tandem mass spectrometry–based assay?
This study evaluated the suitability and accuracy of the automated Roche Elecsys tacrolimus electrochemiluminescence immunoassay (ECLIA) by comparing it with a current laboratory-developed test by liquid chromatography–tandem mass spectrometry (LC-MS/MS). The tacrolimus ECLIA was evaluated for precision, linearity, interference, and postextraction stability. Accuracy was compared with LC-MS/MS. The tacrolimus ECLIA assay is precise, exhibits a measuring range of 0.75 to 30 ng/mL, and is tolerant of significant interferences (plasma indices: hemolysis r2 = 0.97; Sy/x = 0.94; n = 43) and an absolute mean (SD) bias of 2.2 (1.7) ng/mL. Postextraction studies confirmed that samples were stable for up to 30 minutes under routine laboratory conditions. The 2 major challenges for implementation of the tacrolimus ECLIA assay are the postextraction sample stability and the significant proportional bias observed compared with the LC-MS/MS reference method. The 30-minute window for analysis of extracted samples is a practical challenge to the routine workflow of the core laboratory. In addition, disagreement between the immunoassay and LC-MS/MS methods can lead to discordant clinical interpretations and ultimately affect patient care.
- 28 August 2023
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 161 (1) , 1-3
Time to stop reporting estimates of any prostate cancer risk with percentage of free prostate-specific antigen
Serum prostate-specific antigen (PSA) testing is a cornerstone of the diagnosis and management of prostate cancer (PCa), but its poor specificity is a significant limitation to its utility as a screening test. This issue has led to an ongoing search for screening biomarkers that can be used in men without a diagnosis of PCa. One such marker is free PSA, which is the fraction of PSA in the serum unbound to proteins. Free PSA is divided by total PSA to calculate the percentage of free PSA (%fPSA), which is a well-studied biomarker with an inverse relationship to the risk of PCa. Head to head, %fPSA outperforms total PSA in detecting any PCa and grade group 2 or higher PCa.1,2 Percent-free PSA is widely used in the work-up for PCa on its own or as a component of composite tests such as The 4Kscore Test or Prostate Health Index. To aid with interpretation, laboratories often report %fPSA results with a standardized table that provides estimates for risk of biopsy-detected PCa based on %fPSA. Although the estimates provided vary by institution, they generally describe %fPSA less than 10% as higher risk and %fPSA above 25% as lower risk. At many institutions, including ours, for men with PSA values between 4 and 10 ng/mL, the reported risk of PCa if %fPSA is less than 10% is greater than 40%, whereas in those with %fPSA above 25%, it is less than 10% Figure 1.
- 28 August 2023
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 161 (1) , 1-3
Time to stop reporting estimates of any prostate cancer risk with percentage of free prostate-specific antigen
Serum prostate-specific antigen (PSA) testing is a cornerstone of the diagnosis and management of prostate cancer (PCa), but its poor specificity is a significant limitation to its utility as a screening test. This issue has led to an ongoing search for screening biomarkers that can be used in men without a diagnosis of PCa. One such marker is free PSA, which is the fraction of PSA in the serum unbound to proteins. Free PSA is divided by total PSA to calculate the percentage of free PSA (%fPSA), which is a well-studied biomarker with an inverse relationship to the risk of PCa. Head to head, %fPSA outperforms total PSA in detecting any PCa and grade group 2 or higher PCa.1,2 Percent-free PSA is widely used in the work-up for PCa on its own or as a component of composite tests such as The 4Kscore Test or Prostate Health Index. To aid with interpretation, laboratories often report %fPSA results with a standardized table that provides estimates for risk of biopsy-detected PCa based on %fPSA. Although the estimates provided vary by institution, they generally describe %fPSA less than 10% as higher risk and %fPSA above 25% as lower risk. At many institutions, including ours, for men with PSA values between 4 and 10 ng/mL, the reported risk of PCa if %fPSA is less than 10% is greater than 40%, whereas in those with %fPSA above 25%, it is less than 10% Figure 1.
- 2 January 2023
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 8 (2) , 285-295
Reducing Specimen Rejection Rates Using Concentration-Dependent Hemolysis Rejection Thresholds
Background: Using middleware solutions, it is possible to implement concentration-dependent analyte-specific hemolysis rejection limits. This makes day-to-day reporting of clinical specimens more efficient and potentially lowers sample rejection rates compared to a “one-size-fits-all” approach (i.e., solely based on a single cutoff provided in the package insert). Methods: Hemolysis interference studies were performed at multiple analyte concentrations for three frequently ordered tests. For each assay, concentration-dependent hemolysis rejection limits were designed based on the total allowable error (TAE) for the analyte as well as the clinical significance of such incurred inaccuracy at the respective concentrations. In general, the following rationale was used: if the interference exceeds 10% (or package insert cutoffs), a comment is placed on the result. If the interference exceeds the TAE, the result will not be reported. Reduction in specimen rejection rates were estimated by comparing the incurred specimen rejection rates when package inserts’ vs concentration-dependent hemolysis interference limits were applied to a data set in our institute during a three-month period. Results: Concentration-dependent analyte-specific hemolysis rejection thresholds were designed for three commonly ordered assays that are especially susceptible to hemolysis interference. It is estimated that these novel thresholds for aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and direct bilirubin (DBIL) reduced specimen rejection rates from 9.3% to 1.3%, 31.4% to 4.8%, and 19.9% to 7.1%, respectively. Conclusions: Concentration-dependent analyte-specific hemolysis rejection thresholds for three commonly ordered assays can reduce rejection rates without significantly compromising the quality of test results.
- 2 January 2023
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 8 (2) , 285-295
Reducing Specimen Rejection Rates Using Concentration-Dependent Hemolysis Rejection Thresholds
Background: Using middleware solutions, it is possible to implement concentration-dependent analyte-specific hemolysis rejection limits. This makes day-to-day reporting of clinical specimens more efficient and potentially lowers sample rejection rates compared to a “one-size-fits-all” approach (i.e., solely based on a single cutoff provided in the package insert). Methods: Hemolysis interference studies were performed at multiple analyte concentrations for three frequently ordered tests. For each assay, concentration-dependent hemolysis rejection limits were designed based on the total allowable error (TAE) for the analyte as well as the clinical significance of such incurred inaccuracy at the respective concentrations. In general, the following rationale was used: if the interference exceeds 10% (or package insert cutoffs), a comment is placed on the result. If the interference exceeds the TAE, the result will not be reported. Reduction in specimen rejection rates were estimated by comparing the incurred specimen rejection rates when package inserts’ vs concentration-dependent hemolysis interference limits were applied to a data set in our institute during a three-month period. Results: Concentration-dependent analyte-specific hemolysis rejection thresholds were designed for three commonly ordered assays that are especially susceptible to hemolysis interference. It is estimated that these novel thresholds for aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and direct bilirubin (DBIL) reduced specimen rejection rates from 9.3% to 1.3%, 31.4% to 4.8%, and 19.9% to 7.1%, respectively. Conclusions: Concentration-dependent analyte-specific hemolysis rejection thresholds for three commonly ordered assays can reduce rejection rates without significantly compromising the quality of test results.