Frantisek Rund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frantisek Rund has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Jaroslav Bouse
Department of Radioelectronics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, 166 27, Czech Republic
4 shared publicationsVáclav Vencovský
Department of Radioelectronics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, 166 27, Czech Republic
3 shared publications- Václav Vencovský
Department of Radio Engineering, Czech Technical University in Prague 1 , Technická 2, 166 27 Prague
3 shared publications - Dominik Storek
Czech Technical University in Prague
2 shared publications - Petr Marsalek
Department of Animal Protection and Welfare and Veterinary Public Health, Faculty of Veterinary Hygiene and Ecology, University of Veterinary Sciences Brno, 612 42 Brno, Czech Republic
2 shared publications - Aleš Vetešník
Department of Nuclear Chemistry, Czech Technical University in Prague, Czech Republic
1 shared publication
Latest Publications
- 11 November 2021
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 69 (7/8) , 586-593
An Evaluation of Click Detection Algorithms Against the Results of Listening Tests
This paper evaluates the ability of several algorithms to detect impulse distortions (clicks) in audio signals. The systems are evaluated against data from a listening test conducted using real audio signals provided by a vinyl manufacturer. Some of the signals contained clicks due to damage during the manufacturing process. An evaluation of click detection algorithms against listening test results focuses on the ability of the click-detection algorithms to detect perceptible clicks. The...
- 11 November 2021
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 69 (7/8) , 586-593
An Evaluation of Click Detection Algorithms Against the Results of Listening Tests
This paper evaluates the ability of several algorithms to detect impulse distortions (clicks) in audio signals. The systems are evaluated against data from a listening test conducted using real audio signals provided by a vinyl manufacturer. Some of the signals contained clicks due to damage during the manufacturing process. An evaluation of click detection algorithms against listening test results focuses on the ability of the click-detection algorithms to detect perceptible clicks. The...
- 1 January 2019
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 145 (1) , 1-15
Functional rate-code models of the auditory brainstem for predicting lateralization and discrimination data of human binaural perception
This paper presents a rate-code model of binaural interaction inspired by recent neurophysiological findings. The model consists of a peripheral part and a binaural part. The binaural part is composed of models of the medial superior olive (MSO) and the lateral superior olive (LSO), which are parts of the auditory brainstem. The MSO and LSO model outputs are preprocessed in the interaural time difference (ITD) and interaural level difference (ILD) central stages, respectively, which give absolute values of the predicted lateralization at their outputs, allowing a direct comparison with psychophysical data. The predictions obtained with the MSO and LSO models are compared with subjective data on the lateralization of pure tones and narrowband noises, discrimination of the ITD and ILD, and discrimination of the phase warp. The lateralization and discrimination experiments show good agreement with the subjective data. In the case of the phase-warp experiment, the models agree qualitatively with the subjective data. The results demonstrate that rate-code models of MSO and LSO can be used to explain psychophysical data considering lateralization and discrimination based on binaural cues.
- 1 January 2019
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 145 (1) , 1-15
Functional rate-code models of the auditory brainstem for predicting lateralization and discrimination data of human binaural perception
This paper presents a rate-code model of binaural interaction inspired by recent neurophysiological findings. The model consists of a peripheral part and a binaural part. The binaural part is composed of models of the medial superior olive (MSO) and the lateral superior olive (LSO), which are parts of the auditory brainstem. The MSO and LSO model outputs are preprocessed in the interaural time difference (ITD) and interaural level difference (ILD) central stages, respectively, which give absolute values of the predicted lateralization at their outputs, allowing a direct comparison with psychophysical data. The predictions obtained with the MSO and LSO models are compared with subjective data on the lateralization of pure tones and narrowband noises, discrimination of the ITD and ILD, and discrimination of the phase warp. The lateralization and discrimination experiments show good agreement with the subjective data. In the case of the phase-warp experiment, the models agree qualitatively with the subjective data. The results demonstrate that rate-code models of MSO and LSO can be used to explain psychophysical data considering lateralization and discrimination based on binaural cues.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparison of two objective methods of quality assessment for digital audio broadcasting
Monitoring of the audio content quality is important for Digital Audio Broadcasting. Although the subjective methods asses quality more reliably, the objective methods have to be considered when needed big amount of the repeated tests. The highest differences between results of objective and subjective assessment were proved for modern high efficient codecs in the case of the lower bitrates. In this paper, two objective methods, PEAQ and PEMO-Q, are compared to be able to choose the more reliable method for audio quality monitoring. It is shown that PEMO-Q gives better results in the case of lower bitrates for the both High Efficiency profiles of Advanced Audio Coding codec. But the improvement is not essential considering the differences between results of the objective and the subjective assessment methods. Moreover, for music samples, PEMO-Q method brings worse results in the case of lower bitrates for Low Complexity profile of Advanced Audio Coding codec.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparison of two objective methods of quality assessment for digital audio broadcasting
Monitoring of the audio content quality is important for Digital Audio Broadcasting. Although the subjective methods asses quality more reliably, the objective methods have to be considered when needed big amount of the repeated tests. The highest differences between results of objective and subjective assessment were proved for modern high efficient codecs in the case of the lower bitrates. In this paper, two objective methods, PEAQ and PEMO-Q, are compared to be able to choose the more reliable method for audio quality monitoring. It is shown that PEMO-Q gives better results in the case of lower bitrates for the both High Efficiency profiles of Advanced Audio Coding codec. But the improvement is not essential considering the differences between results of the objective and the subjective assessment methods. Moreover, for music samples, PEMO-Q method brings worse results in the case of lower bitrates for Low Complexity profile of Advanced Audio Coding codec.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Drum Kit sound localization tests on binaural hearing model with ANN
Binaural hearing is an important ability of humans. While utilizing a binaural hearing model with Artificial Neural Network it is possible to simulate localization of sound source position by humans. In this paper localization of drum kit sounds as well as localization prediction dependence on head related functions used to synthesize these drum kit sounds are concerned. Three separate tests were performed using two classification algorithms: for horizontal plane only, for both horizontal and vertical planes (Koshkina E., Bouse J., Proc. of Poster 2017). In the first test localization of auralized drum kit sounds through different HRTF sets at fixed positions was performed to observe elevation and azimuth prediction differences. In the other two tests localization at unfixed positions for drum kit sounds with and without room reflections was performed.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Drum Kit sound localization tests on binaural hearing model with ANN
Binaural hearing is an important ability of humans. While utilizing a binaural hearing model with Artificial Neural Network it is possible to simulate localization of sound source position by humans. In this paper localization of drum kit sounds as well as localization prediction dependence on head related functions used to synthesize these drum kit sounds are concerned. Three separate tests were performed using two classification algorithms: for horizontal plane only, for both horizontal and vertical planes (Koshkina E., Bouse J., Proc. of Poster 2017). In the first test localization of auralized drum kit sounds through different HRTF sets at fixed positions was performed to observe elevation and azimuth prediction differences. In the other two tests localization at unfixed positions for drum kit sounds with and without room reflections was performed.
- 19 March 2018
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 66 (3) , 167-171
Reference Equivalent Threshold Sound Pressure Levels for Nonaudiometric Headphones
For a given type of headphone, the sound pressure levels of pure tones at which an adequate number of young listeners without hearing loss just perceived the tones is called Reference Equivalent Threshold Sound Pressure Levels (RETSPLs). Current standards and norms have established RETSPL values for specific headphones; other headphones do not have such values. Although the Sennheiser HD 650 circumaural headphone is often used in behavioral experiments and listening tests, its RETSPL values...
- 19 March 2018
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 66 (3) , 167-171
Reference Equivalent Threshold Sound Pressure Levels for Nonaudiometric Headphones
For a given type of headphone, the sound pressure levels of pure tones at which an adequate number of young listeners without hearing loss just perceived the tones is called Reference Equivalent Threshold Sound Pressure Levels (RETSPLs). Current standards and norms have established RETSPL values for specific headphones; other headphones do not have such values. Although the Sennheiser HD 650 circumaural headphone is often used in behavioral experiments and listening tests, its RETSPL values...
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 090003
The relationship between SFOAEs and tuning of cochlear filters in a model of the human cochlea
It has been suggested that the stimulus frequency otoacoustic emissions (SFOAEs) are generated due to coherent reflections of forward-traveling waves. In this paper, the emissions were simulated by a two-dimensional hydrodynamic cochlea model with parameters based on real dimensions of the human cochlea. Simulations were done using a low-level pure tone at frequencies between 0.5 and 1.3 kHz, and 3 and 6 kHz. In agreement with animal experimental data, the ratio between the simulated SFOAE group delays and group delays estimated from the basilar membrane transfer functions were between 1 and 2. In agreement with the coherent reflection filtering theory, the SFOAE delay was affected by the frequency selectivity of the cochlear filters. However, the simulated results gave different tuning ratios for two models differing only in tuning of their cochlear filters.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 090003
The relationship between SFOAEs and tuning of cochlear filters in a model of the human cochlea
It has been suggested that the stimulus frequency otoacoustic emissions (SFOAEs) are generated due to coherent reflections of forward-traveling waves. In this paper, the emissions were simulated by a two-dimensional hydrodynamic cochlea model with parameters based on real dimensions of the human cochlea. Simulations were done using a low-level pure tone at frequencies between 0.5 and 1.3 kHz, and 3 and 6 kHz. In agreement with animal experimental data, the ratio between the simulated SFOAE group delays and group delays estimated from the basilar membrane transfer functions were between 1 and 2. In agreement with the coherent reflection filtering theory, the SFOAE delay was affected by the frequency selectivity of the cochlear filters. However, the simulated results gave different tuning ratios for two models differing only in tuning of their cochlear filters.
- 1 December 2017
- Published by University of California Press in Music Perception: An Interdisciplinary Journal
- Vol. 35 (2) , 127-143
Roughness of Two Simultaneous Harmonic Complex Tones On Just-Tempered and Equal-Tempered Scales
This study is focused on the perceived roughness of two simultaneous harmonic complex tones with ratios between their fundamental frequencies set to create intervals on just-tempered (JT) and equal-tempered (ET) scales. According to roughness theories, ET intervals should produce more roughness. However, previous studies have shown the opposite for intervals in which the lower fundamental frequency of the complex was equal to 261.6 Hz. The aim of this study is to verify and explain these results by using intervals composed of complexes whose spectral components were generated with either a sine starting phase or with a random starting phase. Results of the current study showed the same phenomenon as previous studies. To examine whether the explanation of the phenomenon lies in the function of the peripheral ear, three roughness models based upon this function were used: the Daniel and Weber (1997) model, the synchronization index (SI) model, and the model based on a hydrodynamic cochlear model. For most of the corresponding JT and ET intervals, only the Daniel and Weber (1997) model predicted less roughness in the ET intervals. In addition to this, the intervals were analyzed by a model simulating the auditory periphery. The results showed that a possible cause for the roughness differences may be in the frequencies of fluctuations of the signal in the peripheral ear. For JT intervals the fluctuations in the adjacent places on the simulated basilar membrane had either the same frequency or integer multiples of that frequency and were synchronized. Since a previous study showed that synchronized fluctuations in adjacent auditory filters lead to higher roughness than out of phase fluctuations (Terhardt, 1974), this may cause more roughness across JT and ET intervals.
- 1 December 2017
- Published by University of California Press in Music Perception: An Interdisciplinary Journal
- Vol. 35 (2) , 127-143
Roughness of Two Simultaneous Harmonic Complex Tones On Just-Tempered and Equal-Tempered Scales
This study is focused on the perceived roughness of two simultaneous harmonic complex tones with ratios between their fundamental frequencies set to create intervals on just-tempered (JT) and equal-tempered (ET) scales. According to roughness theories, ET intervals should produce more roughness. However, previous studies have shown the opposite for intervals in which the lower fundamental frequency of the complex was equal to 261.6 Hz. The aim of this study is to verify and explain these results by using intervals composed of complexes whose spectral components were generated with either a sine starting phase or with a random starting phase. Results of the current study showed the same phenomenon as previous studies. To examine whether the explanation of the phenomenon lies in the function of the peripheral ear, three roughness models based upon this function were used: the Daniel and Weber (1997) model, the synchronization index (SI) model, and the model based on a hydrodynamic cochlear model. For most of the corresponding JT and ET intervals, only the Daniel and Weber (1997) model predicted less roughness in the ET intervals. In addition to this, the intervals were analyzed by a model simulating the auditory periphery. The results showed that a possible cause for the roughness differences may be in the frequencies of fluctuations of the signal in the peripheral ear. For JT intervals the fluctuations in the adjacent places on the simulated basilar membrane had either the same frequency or integer multiples of that frequency and were synchronized. Since a previous study showed that synchronized fluctuations in adjacent auditory filters lead to higher roughness than out of phase fluctuations (Terhardt, 1974), this may cause more roughness across JT and ET intervals.
- 27 December 2016
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 64 (12) , 978-987
Impulse Response Measurements using MLS Technique on Nonsynchronous Devices
Maximum-length sequences (MLS) are widely used for measurement of impulse responses of linear time-invariant systems in acoustic and audio systems. It is usually believed that one of the drawbacks of the MLS technique is a requirement of synchronized devices used for the generation and acquisition of the MLS signals. This study shows that the MLS technique can easily be improved and applied to devices that are not synchronous, or operate at different sampling frequencies. To show the...
- 27 December 2016
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 64 (12) , 978-987
Impulse Response Measurements using MLS Technique on Nonsynchronous Devices
Maximum-length sequences (MLS) are widely used for measurement of impulse responses of linear time-invariant systems in acoustic and audio systems. It is usually believed that one of the drawbacks of the MLS technique is a requirement of synchronized devices used for the generation and acquisition of the MLS signals. This study shows that the MLS technique can easily be improved and applied to devices that are not synchronous, or operate at different sampling frequencies. To show the...
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 41 (3) , 437-447
Subjective Evaluation of Three Headphone-Based Virtual Sound Source Positioning Methods Including Differential Head-Related Transfer Function
This paper analyses the performance of Differential Head-Related Transfer Function (DHRTF), an alternative transfer function for headphone-based virtual sound source positioning within a horizontal plane. This experimental one-channel function is used to reduce processing and avoid timbre affection while preserving signal features important for sound localisation. The use of positioning algorithm employing the DHRTF is compared to two other common positioning methods: amplitude panning and HRTF processing. Results of theoretical comparison and quality assessment of the methods by subjective listening tests are presented. The tests focus on distinctive aspects of the positioning methods: spatial impression, timbre affection, and loudness fluctuations. The results show that the DHRTF positioning method is applicable with very promising performance; it avoids perceptible channel coloration that occurs within the HRTF method, and it delivers spatial impression more successfully than the simple amplitude panning method.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Archives of Acoustics
- Vol. 41 (3) , 437-447
Open AccessSubjective Evaluation of Three Headphone-Based Virtual Sound Source Positioning Methods Including Differential Head-Related Transfer Function
This paper analyses the performance of Differential Head-Related Transfer Function (DHRTF), an alternative transfer function for headphone-based virtual sound source positioning within a horizontal plane. This experimental one-channel function is used to reduce processing and avoid timbre affection while preserving signal features important for sound localisation. The use of positioning algorithm employing the DHRTF is compared to two other common positioning methods: amplitude panning and HRTF processing. Results of theoretical comparison and quality assessment of the methods by subjective listening tests are presented. The tests focus on distinctive aspects of the positioning methods: spatial impression, timbre affection, and loudness fluctuations. The results show that the DHRTF positioning method is applicable with very promising performance; it avoids perceptible channel coloration that occurs within the HRTF method, and it delivers spatial impression more successfully than the simple amplitude panning method.
- 21 April 2016
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 64 (4) , 208-217
Artifact Reduction in Positioning Algorithm Using Differential HRTF
This article introduces three methods for artifact reduction in Differential Head-Related Transfer Function (DHRTF). Such artifacts may occur within virtual sound source positioning methods when spike-like spectral peaks occur in the module of the DHRTF. These spectral features result in an undesirable whistling-like sound component that distorts both timbre and spatial perception of the virtual sound. DHRTF filters require preprocessing by an appropriate method that is able to remove or...
- 21 April 2016
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 64 (4) , 208-217
Artifact Reduction in Positioning Algorithm Using Differential HRTF
This article introduces three methods for artifact reduction in Differential Head-Related Transfer Function (DHRTF). Such artifacts may occur within virtual sound source positioning methods when spike-like spectral peaks occur in the module of the DHRTF. These spectral features result in an undesirable whistling-like sound component that distorts both timbre and spatial perception of the virtual sound. DHRTF filters require preprocessing by an appropriate method that is able to remove or...