Gutian Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gutian Zhao has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Jie Cheng
24 shared publications- Zhonghua Ni
School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacturing of Precision Medicine Equipment, Southeast University, Nanjing, 211189, China
23 shared publications Gensheng Wu
22 shared publicationsXue Hu
16 shared publicationsBin Wang
Jiangsu Key Laboratory for Design and Manufacturing of Precision Medicine Equipment, Southeast University, Nanjing, 211189, China
15 shared publicationsYuan Tian
School of Mechano-Electronic Engineering, Suzhou Polytechnic University, Suzhou, 215104, China
14 shared publications
Latest Publications
- 8 May 2026
- Published by Wiley in CLEAN – Soil, Air, Water
- Vol. 54 (5) , e70194
Dual‐Scale Channels of Hollow Reed Stem Toward Synergistic Thermal and Water Management in Solar Evaporation
Interfacial solar vapor generation presents a promising avenue for sustainable freshwater production. However, its practical implementation is impeded by high energy cost, salt accumulation, and unstable water supply. Inspiration, drawn from natural reeds, effectively transports water across long distance. The evaporator utilizes the hierarchical and porous vascular bundles as optimal channels for spontaneous water pumping. Various reeds are systematically evaluated before and after delignification. These findings show that the reeds with hollow structure facilitate thermal localization through their internal air gaps while enabling rapid vapor escape via its central cavity. This innovative design yields the superior evaporation performance that significantly exceeds that of solid reeds, exhibiting a distinctive and positive size effect up to a certain scale. Microscopic characterization indicates that the microstructures of hollow reeds, coupled with enhanced hydrophilicity resulting from delignification, collectively ensure rapid capillary water transport. Furthermore, numerical simulations confirm that the evaporation performance can be further optimized by adjusting wall thickness. This work introduces a bio‐inspired structural prototype spanning both micro‐ and macroscales for water evaporation. It demonstrates the substantial potential of engineered natural materials for automatic pumping, structural stability, and resistance to salt fouling within sustainable water purification technologies.
- 8 May 2026
- Published by Wiley in CLEAN – Soil, Air, Water
- Vol. 54 (5) , e70194
Dual‐Scale Channels of Hollow Reed Stem Toward Synergistic Thermal and Water Management in Solar Evaporation
Interfacial solar vapor generation presents a promising avenue for sustainable freshwater production. However, its practical implementation is impeded by high energy cost, salt accumulation, and unstable water supply. Inspiration, drawn from natural reeds, effectively transports water across long distance. The evaporator utilizes the hierarchical and porous vascular bundles as optimal channels for spontaneous water pumping. Various reeds are systematically evaluated before and after delignification. These findings show that the reeds with hollow structure facilitate thermal localization through their internal air gaps while enabling rapid vapor escape via its central cavity. This innovative design yields the superior evaporation performance that significantly exceeds that of solid reeds, exhibiting a distinctive and positive size effect up to a certain scale. Microscopic characterization indicates that the microstructures of hollow reeds, coupled with enhanced hydrophilicity resulting from delignification, collectively ensure rapid capillary water transport. Furthermore, numerical simulations confirm that the evaporation performance can be further optimized by adjusting wall thickness. This work introduces a bio‐inspired structural prototype spanning both micro‐ and macroscales for water evaporation. It demonstrates the substantial potential of engineered natural materials for automatic pumping, structural stability, and resistance to salt fouling within sustainable water purification technologies.
- 26 January 2026
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 27 (2) , 1534-1546
Engineering a Biomimetic Poly( l -lactic acid) Nerve Conduit with Dual-Scale Aligned Topography toward Bridging Large-Gap Peripheral Nerve Injuries
Biodegradable nerve guidance conduits (NGCs) are compelling alternatives to autografts for repairing severe peripheral nerve injuries. However, a major obstacle in developing effective NGCs is their structural and functional mismatch with repair and regeneration, leading to inadequate neuronal guidance and improper axon dispersion. Herein, we report a biomimetic NGC that replicates the multiscale architecture of native nerves. It features aligned microchannels of clinically relevant lengths and nanotextured walls. The biomimetic topology is fabricated in poly(l-lactic acid) (PLLA) via an integrated forming technique that exploits strain-induced crystallization to control crack propagation. Comprehensive in vitro experiments confirm the exceptional thermal stability, mechanical robustness, and structural integrity of PLLA NGCs. Importantly, the synergistic micro- and nanoscale alignment is critical for directing axon growth and minimizing dispersion. By elucidating this novel fabrication mechanism and demonstrating dual-scale bioinspired architecture, our work establishes a new platform with the potential for large-gap peripheral nerve repair.
- 26 January 2026
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 27 (2) , 1534-1546
Engineering a Biomimetic Poly( l -lactic acid) Nerve Conduit with Dual-Scale Aligned Topography toward Bridging Large-Gap Peripheral Nerve Injuries
Biodegradable nerve guidance conduits (NGCs) are compelling alternatives to autografts for repairing severe peripheral nerve injuries. However, a major obstacle in developing effective NGCs is their structural and functional mismatch with repair and regeneration, leading to inadequate neuronal guidance and improper axon dispersion. Herein, we report a biomimetic NGC that replicates the multiscale architecture of native nerves. It features aligned microchannels of clinically relevant lengths and nanotextured walls. The biomimetic topology is fabricated in poly(l-lactic acid) (PLLA) via an integrated forming technique that exploits strain-induced crystallization to control crack propagation. Comprehensive in vitro experiments confirm the exceptional thermal stability, mechanical robustness, and structural integrity of PLLA NGCs. Importantly, the synergistic micro- and nanoscale alignment is critical for directing axon growth and minimizing dispersion. By elucidating this novel fabrication mechanism and demonstrating dual-scale bioinspired architecture, our work establishes a new platform with the potential for large-gap peripheral nerve repair.
- Open Access
- 1 August 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3080 (1)
Evaluation of the low-temperature mechanical properties of Poly (L-lactic acid) self-expanding braided stents
Poly (L-lactic acid) (PLLA), attributed to its remarkable mechanical properties, has been widely applied in the medical field, such as vascular stents. Nevertheless, the mechanical properties of PLLA are notably affected by temperature due to its viscoelastic characteristics. Therefore, this study focuses on exploring the impact of low temperature on the mechanical properties of oriented PLLA and PLLA elf-expanding braided stents. The findings of the study indicate that oriented PLLA exhibits excellent mechanical properties under low-temperature conditions. During the low-temperature crimping process, the PLLA braided stent not only demonstrates good recovery performance but also maintains its mechanical superiority after crimping release. This study provides a solid theoretical foundation for the storage and crimping operations of PLLA braided stents in low-temperature environments, thereby further broadening their application prospects in the field of medical devices.
- 1 August 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3080 (1)
Open AccessEvaluation of the low-temperature mechanical properties of Poly (L-lactic acid) self-expanding braided stents
Poly (L-lactic acid) (PLLA), attributed to its remarkable mechanical properties, has been widely applied in the medical field, such as vascular stents. Nevertheless, the mechanical properties of PLLA are notably affected by temperature due to its viscoelastic characteristics. Therefore, this study focuses on exploring the impact of low temperature on the mechanical properties of oriented PLLA and PLLA elf-expanding braided stents. The findings of the study indicate that oriented PLLA exhibits excellent mechanical properties under low-temperature conditions. During the low-temperature crimping process, the PLLA braided stent not only demonstrates good recovery performance but also maintains its mechanical superiority after crimping release. This study provides a solid theoretical foundation for the storage and crimping operations of PLLA braided stents in low-temperature environments, thereby further broadening their application prospects in the field of medical devices.
- 31 May 2025
- Published by Wiley in Biopolymers
- Vol. 116 (4) , e70034
Bioresorbable Composite Polymeric Stents: Alleviating Deployment Damage and Maintaining Significant Mechanical Properties
The latest‐generation Poly(L‐lactic acid) (PLLA) based fully bioresorbable stents (BRS) are facing a grave challenge due to their higher clinical risk of post‐implantation. There is consensus that the strut thickness of BRS far exceeds that of metal stents; this is the main reason for the poor clinical outcomes. Therefore, overcoming the gap in mechanical properties between PLLA and metal, and effectively reducing the strut thickness of BRS without sacrificing mechanical properties, is a research priority. In this paper, the vital structural weakness of BRS causing the poor mechanical properties was discovered from the preparation process. We proposed the use of an elastomeric coating to alleviate the damage in weakness during deployment. Experiments and numerical simulations conducted on PLLA stents with and without poly(L‐lactide‐co‐ε‐caprolactone) (PLCL) coating have confirmed that they can reduce stress concentration during deployment. The composite stents exhibit higher radial supporting capability after deployment. Significantly, the radial strength of the 100 μm thin‐strut stent increased by 31%, up to 1061.8 mmHg. Moreover, in vivo animal experiments conducted on rabbits show encouraging biocompatibility and effectiveness of the composite stents. Our work provided a pure thin‐strut PLLA stent with superior mechanical properties and biocompatibility, which can become a reliable platform for future research and clinical applications of BRS.
- 31 May 2025
- Published by Wiley in Biopolymers
- Vol. 116 (4) , e70034
Bioresorbable Composite Polymeric Stents: Alleviating Deployment Damage and Maintaining Significant Mechanical Properties
The latest‐generation Poly(L‐lactic acid) (PLLA) based fully bioresorbable stents (BRS) are facing a grave challenge due to their higher clinical risk of post‐implantation. There is consensus that the strut thickness of BRS far exceeds that of metal stents; this is the main reason for the poor clinical outcomes. Therefore, overcoming the gap in mechanical properties between PLLA and metal, and effectively reducing the strut thickness of BRS without sacrificing mechanical properties, is a research priority. In this paper, the vital structural weakness of BRS causing the poor mechanical properties was discovered from the preparation process. We proposed the use of an elastomeric coating to alleviate the damage in weakness during deployment. Experiments and numerical simulations conducted on PLLA stents with and without poly(L‐lactide‐co‐ε‐caprolactone) (PLCL) coating have confirmed that they can reduce stress concentration during deployment. The composite stents exhibit higher radial supporting capability after deployment. Significantly, the radial strength of the 100 μm thin‐strut stent increased by 31%, up to 1061.8 mmHg. Moreover, in vivo animal experiments conducted on rabbits show encouraging biocompatibility and effectiveness of the composite stents. Our work provided a pure thin‐strut PLLA stent with superior mechanical properties and biocompatibility, which can become a reliable platform for future research and clinical applications of BRS.
- 28 March 2025
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 36 (4)
The Key to Increasing the Elongation of Poly (l‐Lactic Acid) Monofilaments in Hydrothermal Environment‐Dislocation Slip
Biodegradable polymers such as poly (l‐lactic acid) (PLLA) have extensive applications in the clinical and medical areas due to their superior mechanical properties. When applied in implantable medical devices, PLLA will inevitably face the challenge of a 37°C liquid environment that can affect its mechanical performance. This study mainly explores the impact of temperature–water synergy on PLLA monofilaments. The combined effects of temperature (25°C–65°C) and the water environment are systematically studied, especially for the 37°C liquid medium simulating the human body. It was found that the mechanical properties of PLLA monofilaments got worse with the increase of temperature or the immersion of water molecules but improved in a 37°C liquid environment, especially for the elongation at break. By scanning electron microscopy (SEM) and wide‐angle X‐ray scattering (WAXS) analysis, it is believed that the key to increasing the elongation in 37°C liquid environment is the extensive occurrence of dislocation slip. This study has provided further understanding of the intrinsic connection between the mechanical properties and structural changes of PLLA monofilaments, which is crucial for the application in medical devices.
- 28 March 2025
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 36 (4)
The Key to Increasing the Elongation of Poly (l‐Lactic Acid) Monofilaments in Hydrothermal Environment‐Dislocation Slip
Biodegradable polymers such as poly (l‐lactic acid) (PLLA) have extensive applications in the clinical and medical areas due to their superior mechanical properties. When applied in implantable medical devices, PLLA will inevitably face the challenge of a 37°C liquid environment that can affect its mechanical performance. This study mainly explores the impact of temperature–water synergy on PLLA monofilaments. The combined effects of temperature (25°C–65°C) and the water environment are systematically studied, especially for the 37°C liquid medium simulating the human body. It was found that the mechanical properties of PLLA monofilaments got worse with the increase of temperature or the immersion of water molecules but improved in a 37°C liquid environment, especially for the elongation at break. By scanning electron microscopy (SEM) and wide‐angle X‐ray scattering (WAXS) analysis, it is believed that the key to increasing the elongation in 37°C liquid environment is the extensive occurrence of dislocation slip. This study has provided further understanding of the intrinsic connection between the mechanical properties and structural changes of PLLA monofilaments, which is crucial for the application in medical devices.
- 21 February 2025
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 26 (3) , 1992-2002
Internal Secondary Structural Conformational States of Silk Fibroin Studied by Raman Spectroscopy with Band Deconvolution Analysis
Silk fibroin (SF) is an extensively utilized biofiber recognized for its excellent mechanical properties across various applications. However, the relationship between its internal structure and mechanical behavior remains inadequately understood. In this work, we employed polarized Raman spectra to investigate how SF's secondary structures respond to external tensile loads. Our results show considerable variations in the amide III band, particularly the 1210 cm-1 random coil subpeak, under tensile stimuli. Subsequent loading-unloading experiments that plotted the peak intensity ratio of I1210 cm-1/I1226 cm-1 against tensile strain produced multiple hysteresis loops, suggesting irreversible structural changes during mechanical cycling. With additional evidence from other characteristic bands, we demonstrate that tensile elongation facilitates the transition of random coils to β-sheets within the SF network, which intrinsically contributes to the fiber's stiffening behavior. This work provides valuable insight into SF's deformation mechanism and highlights the significance of the previously underappreciated amide III band.
- 21 February 2025
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 26 (3) , 1992-2002
Internal Secondary Structural Conformational States of Silk Fibroin Studied by Raman Spectroscopy with Band Deconvolution Analysis
Silk fibroin (SF) is an extensively utilized biofiber recognized for its excellent mechanical properties across various applications. However, the relationship between its internal structure and mechanical behavior remains inadequately understood. In this work, we employed polarized Raman spectra to investigate how SF's secondary structures respond to external tensile loads. Our results show considerable variations in the amide III band, particularly the 1210 cm-1 random coil subpeak, under tensile stimuli. Subsequent loading-unloading experiments that plotted the peak intensity ratio of I1210 cm-1/I1226 cm-1 against tensile strain produced multiple hysteresis loops, suggesting irreversible structural changes during mechanical cycling. With additional evidence from other characteristic bands, we demonstrate that tensile elongation facilitates the transition of random coils to β-sheets within the SF network, which intrinsically contributes to the fiber's stiffening behavior. This work provides valuable insight into SF's deformation mechanism and highlights the significance of the previously underappreciated amide III band.