Yasuo Yoshimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yasuo Yoshimi has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Aaryashree Aaryashree
Innovative Global Program, College of Engineering, Shibaura Institute of Technology, Toyosu, Koto-city, Tokyo, Japan
7 shared publications Akihiko Hatano
Dept. of Material Eng, Shibaura Institute of Technology, Tokyo, Japan
2 shared publications- Akihiko Hatano
Department of Chemistry, Shibaura Institute of Technology, Fukasaku, Minumaku, Saitama-City 337-8570, Saitama, Japan
2 shared publications - Daichi Oino
Department of Applied Chemistry, Shibaura Institute of Technology, Tokyo 135-8548, Japan
2 shared publications - Ewa Moczko
Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Viña del Mar 2562307, Chile
2 shared publications - Hirofumi Ohira
Department of Applied Chemistry, Shibaura Institute of Technology, Tokyo 135-8548, Japan
2 shared publications
Latest Publications
- Open Access
- 24 June 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (13) , 977
A Poly(methacrolein-co-methacrylamide)-Based Template Anchoring Strategy for the Synthesis of Fluorescent Molecularly Imprinted Polymer Nanoparticles for Highly Selective Serotonin Sensing
Neurotransmitters such as serotonin regulate key physiological and cognitive functions, yet real-time detection remains challenging due to the limitations of conventional techniques like amperometry and microdialysis. Fluorescent molecularly imprinted polymer nanoparticles (fMIP-NPs) offer a promising alternative and are typically synthesized via solid-phase synthesis, in which template molecules are covalently immobilized on a solid support to enable site-specific imprinting. However, strong template–template interactions during this process can compromise selectivity. To overcome this, we incorporated a poly(methacrolein-co-methacrylamide)-based template anchoring strategy to minimize undesired template interactions and enhance imprinting efficiency. We optimized the synthesis of poly(methacrolein-co-methacrylamide) under three different conditions by varying the monomer compositions and reaction parameters. The poly(methacrolein-co-methacrylamide) synthesized under Condition 3 (5:1 methacrolein-to-methacrylamide molar ratio, 1:150 initiator-to-total monomer ratio, and 4.59 M total monomer concentration) yielded the most selective fMIP-NPs, whose fluorescence intensity increased with an increase in serotonin concentration, rising by up to 37% upon serotonin binding. This improvement is attributed to higher aldehyde functionality in the poly(methacrolein-co-methacrylamide) which enhances template immobilization and generates a rigid imprinted cavity to interact with serotonin. These findings suggest that the developed fMIP-NPs hold significant potential as imaging probes for neurotransmitter detection, contributing to advanced studies in neural network analysis.
- 24 June 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (13) , 977
Open AccessA Poly(methacrolein-co-methacrylamide)-Based Template Anchoring Strategy for the Synthesis of Fluorescent Molecularly Imprinted Polymer Nanoparticles for Highly Selective Serotonin Sensing
Neurotransmitters such as serotonin regulate key physiological and cognitive functions, yet real-time detection remains challenging due to the limitations of conventional techniques like amperometry and microdialysis. Fluorescent molecularly imprinted polymer nanoparticles (fMIP-NPs) offer a promising alternative and are typically synthesized via solid-phase synthesis, in which template molecules are covalently immobilized on a solid support to enable site-specific imprinting. However, strong template–template interactions during this process can compromise selectivity. To overcome this, we incorporated a poly(methacrolein-co-methacrylamide)-based template anchoring strategy to minimize undesired template interactions and enhance imprinting efficiency. We optimized the synthesis of poly(methacrolein-co-methacrylamide) under three different conditions by varying the monomer compositions and reaction parameters. The poly(methacrolein-co-methacrylamide) synthesized under Condition 3 (5:1 methacrolein-to-methacrylamide molar ratio, 1:150 initiator-to-total monomer ratio, and 4.59 M total monomer concentration) yielded the most selective fMIP-NPs, whose fluorescence intensity increased with an increase in serotonin concentration, rising by up to 37% upon serotonin binding. This improvement is attributed to higher aldehyde functionality in the poly(methacrolein-co-methacrylamide) which enhances template immobilization and generates a rigid imprinted cavity to interact with serotonin. These findings suggest that the developed fMIP-NPs hold significant potential as imaging probes for neurotransmitter detection, contributing to advanced studies in neural network analysis.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (64) , 3409
A Flexible Sensor for Vancomycin Fabricated By Depositing Molecularly Imprinted Carbon Paste on a Wire
1. Introduction Vancomycin (VCM), an antibacterial drug, has a narrow effective blood concentration range, requiring therapeutic drug monitoring (TDM) to measure blood levels and optimize dosing regimens . Neonates, in particular, have large individual differences in the rate of drug metabolism, so strict TDM is necessary, but the dilemma is that the amount of blood drawn must be kept to a minimum. Therefore, we decided to develop a method of TDM without blood sampling by implanting a sensor that detects VCM under the skin. The sensor must be flexible enough not to damage the subcutaneous tissue. We have developed a sensor using a MIP carbon paste (MIP-CP) electrode, in which graphite particles with molecularly imprinted polymers are mixed with oil. Since higher mechanical strength is required for indwelling sensors, we fabricated MIP-carbon dough (MIP-CD) electrodes by mixing MIP with a thermosetting silicon resin prepolymer and thermosetting it. This was applied to a wire to develop a flexible wire-type sensor, and its performance was evaluated. 2. 2. experimental method 2-1. MIP graft polymerization /MIP-CD fabrication Methacrylic acid, ethylene glycol dimethacrylate, and allylamine carboxypropionic-3-ferrocene were graft copolymerized on the surface of graphite particles with fixed polymerization initiator in the presence of template VCM. Then, after washing and drying with sodium chloride solution and distilled water, the uncured MIP-CD was mixed with thermosetting silicone resin at a weight ratio of 7:3. Non-imprinted polymer (NIP)-CD, which was prepared by the same procedure without adding a template during synthesis, was also prepared for comparison. 2-2. Fabrication of MIP-CD sensor Carbon ink was applied to a 20 mm tip of a 50 mm tin-plated copper wire, and uncured MIP-CD was applied on top. Then, silicon resin was applied for insulation to limit the effective area of the MIP-CD electrode, and both the insulation and MIP-CD were heat-cured in a dryer to fabricate the wire electrode shown in Fig. 1. 2-3. measurement method Differential pulse voltammetry was performed on the MIP (or NIP)-CD sensor in phosphate buffer containing VCM or teicoplanin (TEIC), which has a similar structure, and the relationship between current and concentration was plotted. 3. Results and Discussion A comparison of the sensitivity of MIP-CD and NIP-CD electrodes to VCM is shown in Fig. 2: the current at MIP-CD increased linearly with increasing VCM concentration, while that at NIP-CD was insensitive. This result indicates that the current at the MIP-CD electrode reflects the specific binding of VCM to the imprinted binding site. As shown in Fig. 3, the MIP-CD electrode was not sensitive to TEIC and showed high selectivity. Conclusion The electrode with MIP-CD fixed on a wire is strong and flexible, yet has a specific response to VCM, and is expected to be used as an indwelling subcutaneous sensor. *This work was supported by the Bridging Research Program of the Japan Agency for Medical Research and Development (Keio University Center). Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (64) , 3409
A Flexible Sensor for Vancomycin Fabricated By Depositing Molecularly Imprinted Carbon Paste on a Wire
1. Introduction Vancomycin (VCM), an antibacterial drug, has a narrow effective blood concentration range, requiring therapeutic drug monitoring (TDM) to measure blood levels and optimize dosing regimens . Neonates, in particular, have large individual differences in the rate of drug metabolism, so strict TDM is necessary, but the dilemma is that the amount of blood drawn must be kept to a minimum. Therefore, we decided to develop a method of TDM without blood sampling by implanting a sensor that detects VCM under the skin. The sensor must be flexible enough not to damage the subcutaneous tissue. We have developed a sensor using a MIP carbon paste (MIP-CP) electrode, in which graphite particles with molecularly imprinted polymers are mixed with oil. Since higher mechanical strength is required for indwelling sensors, we fabricated MIP-carbon dough (MIP-CD) electrodes by mixing MIP with a thermosetting silicon resin prepolymer and thermosetting it. This was applied to a wire to develop a flexible wire-type sensor, and its performance was evaluated. 2. 2. experimental method 2-1. MIP graft polymerization /MIP-CD fabrication Methacrylic acid, ethylene glycol dimethacrylate, and allylamine carboxypropionic-3-ferrocene were graft copolymerized on the surface of graphite particles with fixed polymerization initiator in the presence of template VCM. Then, after washing and drying with sodium chloride solution and distilled water, the uncured MIP-CD was mixed with thermosetting silicone resin at a weight ratio of 7:3. Non-imprinted polymer (NIP)-CD, which was prepared by the same procedure without adding a template during synthesis, was also prepared for comparison. 2-2. Fabrication of MIP-CD sensor Carbon ink was applied to a 20 mm tip of a 50 mm tin-plated copper wire, and uncured MIP-CD was applied on top. Then, silicon resin was applied for insulation to limit the effective area of the MIP-CD electrode, and both the insulation and MIP-CD were heat-cured in a dryer to fabricate the wire electrode shown in Fig. 1. 2-3. measurement method Differential pulse voltammetry was performed on the MIP (or NIP)-CD sensor in phosphate buffer containing VCM or teicoplanin (TEIC), which has a similar structure, and the relationship between current and concentration was plotted. 3. Results and Discussion A comparison of the sensitivity of MIP-CD and NIP-CD electrodes to VCM is shown in Fig. 2: the current at MIP-CD increased linearly with increasing VCM concentration, while that at NIP-CD was insensitive. This result indicates that the current at the MIP-CD electrode reflects the specific binding of VCM to the imprinted binding site. As shown in Fig. 3, the MIP-CD electrode was not sensitive to TEIC and showed high selectivity. Conclusion The electrode with MIP-CD fixed on a wire is strong and flexible, yet has a specific response to VCM, and is expected to be used as an indwelling subcutaneous sensor. *This work was supported by the Bridging Research Program of the Japan Agency for Medical Research and Development (Keio University Center). Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (64) , 3382
Freshness Indicating Substance Sensor in Meat Using Molecularly Imprinted Carbon Paste Electrode
Fresh fish and meat are rich in adenosine-triphosphate (ATP), which over time is converted via adenosine-diphosphate (ADP) and adenosine-monophosphate (AMP) into the flavor component inosinate, which, with more time, is converted into the unpleasant-tasting components inosine and hypoxanthine . These six substances are indicators to measure the freshness and maturity of meat and fish. If these substances can be easily measured at the distribution site, fair trade based on objective judgments of freshness and ripeness will become possible. We are attempting a simple disposable sensor using molecularly imprinted polymer-immobilized carbon paste (MIP-CP). Graphite particles immobilized with a radical polymerization initiator were immersed in a solution of the target materials, inosine, methacrylamidophenylboronic acid, methacrylic acid, and methylenebisacrylamide, and graft polymerized by photoirradiation. The particles were washed with hydrochloric acid to remove the inosine to obtain graphite covered with an MIP layer. This was mixed with ferrocene-containing silicone oil to form a paste and applied to a commercial carbon screen-printed electrode (Zensor, Taipei) to obtain disposable electrodes. Differential pulse voltammetry was performed in buffer solutions containing inosine or sodium inosinate; the current at 0.9 V vs. Ag/AgCl increased with increasing inosine concentration, but there was little sensitivity to sodium inosinate concentration as shown in the Figure. These results indicate that a sensor has been created that shows a highly selective response to inosine, which is the template for MIP. The measurement takes about 30 seconds. We will continue to improve the reproducibility and develop a sensor that can detect the other five indicator substances in the same way. This work is partially supported by Small-Business Innovation Research (SBIR) Program of Bio-oriented Technology Research Advancement Institution (BRAIN), in Japan (SU23A03). Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (64) , 3382
Freshness Indicating Substance Sensor in Meat Using Molecularly Imprinted Carbon Paste Electrode
Fresh fish and meat are rich in adenosine-triphosphate (ATP), which over time is converted via adenosine-diphosphate (ADP) and adenosine-monophosphate (AMP) into the flavor component inosinate, which, with more time, is converted into the unpleasant-tasting components inosine and hypoxanthine . These six substances are indicators to measure the freshness and maturity of meat and fish. If these substances can be easily measured at the distribution site, fair trade based on objective judgments of freshness and ripeness will become possible. We are attempting a simple disposable sensor using molecularly imprinted polymer-immobilized carbon paste (MIP-CP). Graphite particles immobilized with a radical polymerization initiator were immersed in a solution of the target materials, inosine, methacrylamidophenylboronic acid, methacrylic acid, and methylenebisacrylamide, and graft polymerized by photoirradiation. The particles were washed with hydrochloric acid to remove the inosine to obtain graphite covered with an MIP layer. This was mixed with ferrocene-containing silicone oil to form a paste and applied to a commercial carbon screen-printed electrode (Zensor, Taipei) to obtain disposable electrodes. Differential pulse voltammetry was performed in buffer solutions containing inosine or sodium inosinate; the current at 0.9 V vs. Ag/AgCl increased with increasing inosine concentration, but there was little sensitivity to sodium inosinate concentration as shown in the Figure. These results indicate that a sensor has been created that shows a highly selective response to inosine, which is the template for MIP. The measurement takes about 30 seconds. We will continue to improve the reproducibility and develop a sensor that can detect the other five indicator substances in the same way. This work is partially supported by Small-Business Innovation Research (SBIR) Program of Bio-oriented Technology Research Advancement Institution (BRAIN), in Japan (SU23A03). Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (65) , 3192
A Disposable Sensor for Rapid Histamine Detection in Fish Using Molecularly Imprinted Carbon Paste Electrode
Introduction: Histamine (HM), a toxic compound, is produced due to an enzymatic reaction when histidine (HS)-rich red fish such as tunas and other fish and their processed products are improperly stored, e.g., leaving them at room temperature. With the increasing popularity of raw fish consumption, HM analysis is mandatory for these fish in various countries. However, the conventional immunoassay method is time-consuming, costly, and technically demanding, burdening wholesalers heavily. Molecularly Imprinted Polymers-based materials are attractive materials for sensor fabrication due to their high selectivity, stability, and ease of production. In this study, we attempted to develop a Molecularly Imprinted Polymer grafted Carbon Paste (MIP-CP) for histamine sensing. Experimental Methods First, a radical polymerization initiator was fixed on the surface of graphite particles [1]. Next, histamine dihydrochloride, itaconic acid, and ethylene glycol dimethacrylate (EDMA) were dissolved in a mixture of distilled water and dimethylformamide to prepare a polymerization solution. The polymerization solution and initiator-fixed graphite were placed in a quartz tube and irradiated with a xenon lamp for 1 hr. HM was extracted and removed using acetic acid. MIP-CP was prepared by mixing MIP-grafted graphite and silicon oil containing ferrocene in a 7:3 weight ratio. Non-imprinted polymer (NIP)-CP was also prepared using the same procedure, except that HM was not added. Differential pulse voltammetry (DPV) was performed with electrodes packed with the obtained MIP-CPs on a disposable chip [2]. The performance of the HM sensor was evaluated based on the relationship between the oxidation current of ferrocene and HM concentration. (Measurement range 0 μg/mL~100 μg/mL) Experimental results The dependence of the oxidation current density on HM concentration at the NIP and MIP electrodes was confirmed (0.0085 μA-mL/μg, R²=0.9357). The increase in current density with increasing HM concentration at the MIP-CP electrode was more than three times greater than at the NIP-CP electrode. This confirmed that MIP-CP exhibited current changes corresponding to the interaction between HM and HM-imprinted sites. Furthermore, the current increased linearly with increasing HM concentration from 0-100 µg/mL. This dynamic range includes 50 µg/mL, which is considered the lower limit of acceptable Hm concentration in fish meat. However, the current value was constant for HS concentration at 0.75 µA over the range of 40-100 µg/mL and below. Therefore, the sensor is saturated with HS at concentrations above 40 µg/mL, and histidine interference can be excluded by subtracting 0.75 µA from the current value obtained when measuring the fish meat sample. Conclusion We successfully developed a reagentless, disposable histamine sensor using MIP-CP, which provides a rapid, reliable, and cost-effective method for histamine detection in fish. References: [1] Y. Yoshimi, Y. Yagisawa, R. Yamaguchi, and M. Seki, Sen. Act. B Chem., 259, 455–462, 2018. [2] Aaryashree; Choudhary, A.K.; Yoshimi, Y., Sensors, 23, p3271, 2023. Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (65) , 3192
A Disposable Sensor for Rapid Histamine Detection in Fish Using Molecularly Imprinted Carbon Paste Electrode
Introduction: Histamine (HM), a toxic compound, is produced due to an enzymatic reaction when histidine (HS)-rich red fish such as tunas and other fish and their processed products are improperly stored, e.g., leaving them at room temperature. With the increasing popularity of raw fish consumption, HM analysis is mandatory for these fish in various countries. However, the conventional immunoassay method is time-consuming, costly, and technically demanding, burdening wholesalers heavily. Molecularly Imprinted Polymers-based materials are attractive materials for sensor fabrication due to their high selectivity, stability, and ease of production. In this study, we attempted to develop a Molecularly Imprinted Polymer grafted Carbon Paste (MIP-CP) for histamine sensing. Experimental Methods First, a radical polymerization initiator was fixed on the surface of graphite particles [1]. Next, histamine dihydrochloride, itaconic acid, and ethylene glycol dimethacrylate (EDMA) were dissolved in a mixture of distilled water and dimethylformamide to prepare a polymerization solution. The polymerization solution and initiator-fixed graphite were placed in a quartz tube and irradiated with a xenon lamp for 1 hr. HM was extracted and removed using acetic acid. MIP-CP was prepared by mixing MIP-grafted graphite and silicon oil containing ferrocene in a 7:3 weight ratio. Non-imprinted polymer (NIP)-CP was also prepared using the same procedure, except that HM was not added. Differential pulse voltammetry (DPV) was performed with electrodes packed with the obtained MIP-CPs on a disposable chip [2]. The performance of the HM sensor was evaluated based on the relationship between the oxidation current of ferrocene and HM concentration. (Measurement range 0 μg/mL~100 μg/mL) Experimental results The dependence of the oxidation current density on HM concentration at the NIP and MIP electrodes was confirmed (0.0085 μA-mL/μg, R²=0.9357). The increase in current density with increasing HM concentration at the MIP-CP electrode was more than three times greater than at the NIP-CP electrode. This confirmed that MIP-CP exhibited current changes corresponding to the interaction between HM and HM-imprinted sites. Furthermore, the current increased linearly with increasing HM concentration from 0-100 µg/mL. This dynamic range includes 50 µg/mL, which is considered the lower limit of acceptable Hm concentration in fish meat. However, the current value was constant for HS concentration at 0.75 µA over the range of 40-100 µg/mL and below. Therefore, the sensor is saturated with HS at concentrations above 40 µg/mL, and histidine interference can be excluded by subtracting 0.75 µA from the current value obtained when measuring the fish meat sample. Conclusion We successfully developed a reagentless, disposable histamine sensor using MIP-CP, which provides a rapid, reliable, and cost-effective method for histamine detection in fish. References: [1] Y. Yoshimi, Y. Yagisawa, R. Yamaguchi, and M. Seki, Sen. Act. B Chem., 259, 455–462, 2018. [2] Aaryashree; Choudhary, A.K.; Yoshimi, Y., Sensors, 23, p3271, 2023. Figure 1
- 15 April 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (1) , 77-81
A disposable edoxaban sensor chip using carbon paste electrode grafted with molecularly imprinted polymer
Although direct oral anticoagulants (DOACs) are generally safe and TDM is not required, blood levels of the drug are important information for response decisions in emergency care. In this study, an attempt was made to develop a disposable sensor chip for the rapid detection of edoxaban in blood, a type of DOAC. Molecularly imprinted polymers with edoxaban tosilate as a template and sodium p-styrene sulfonate as a functional monomer were grafted onto the surface of graphite particles, mixed with silicon oil dissolved in ferrocene to form a paste, and filled onto a substrate made of plastic film. Sensor chips were fabricated. The current obtained from this sensor by voltammetry within 150 s depended on the edoxaban concentration. Sensitivity to edoxaban was also confirmed in bovine whole blood. The potential of disposable sensors to rapidly detect edoxaban in whole blood was demonstrated in this study, although selectivity, reproducibility, and sensitivity need to be improved for practical use.
- 15 April 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (1) , 77-81
A disposable edoxaban sensor chip using carbon paste electrode grafted with molecularly imprinted polymer
Although direct oral anticoagulants (DOACs) are generally safe and TDM is not required, blood levels of the drug are important information for response decisions in emergency care. In this study, an attempt was made to develop a disposable sensor chip for the rapid detection of edoxaban in blood, a type of DOAC. Molecularly imprinted polymers with edoxaban tosilate as a template and sodium p-styrene sulfonate as a functional monomer were grafted onto the surface of graphite particles, mixed with silicon oil dissolved in ferrocene to form a paste, and filled onto a substrate made of plastic film. Sensor chips were fabricated. The current obtained from this sensor by voltammetry within 150 s depended on the edoxaban concentration. Sensitivity to edoxaban was also confirmed in bovine whole blood. The potential of disposable sensors to rapidly detect edoxaban in whole blood was demonstrated in this study, although selectivity, reproducibility, and sensitivity need to be improved for practical use.
- Open Access
Disposable Sensor Chips with Molecularly Imprinted Carbon Paste Electrodes for Monitoring Anti-Epileptic Drugs
Epilepsy is a neurological disorder that affects millions of people worldwide. Anti-epileptic drugs (AEDs) are critical for their management. However, the therapeutic window is narrow, and traditional laboratory-based therapeutic drug monitoring (TDM) methods can be time consuming and unsuitable for point-of-care testing. To address this issue, we developed a disposable sensor chip based on molecularly imprinted polymer-modified carbon paste electrodes (MIP-CPs) for the TDM of AEDs such as phenobarbital (PB), carbamazepine (CBZ), and levetiracetam (LEV). In this work, functional monomers (methacrylic acid) and crosslinking monomers (methylene bisacrylamide and ethylene glycol dimethacrylate) were copolymerized in the presence of the AED template and grafted on the graphite particles by simple radical photopolymerization. The grafted particles were mixed with silicon oil, dissolving ferrocene as a redox marker to make the MIP-carbon paste (CP). Disposable sensor chips were fabricated by packing the MIP-CP into the base made of poly (ethylene glycol terephthalate) (PET) film. The sensor’s sensitivity was determined using differential pulse voltammetry (DPV), carried out on a single sensor chip for each operation. Linearity was obtained from 0–60 μg/mL in PB and LEV and 0–12 μg/mL in CBZ, covering their respective therapeutic range. The time taken for each measurement was around 2 min. The experiment using whole bovine blood and bovine plasma indicated that the existence of species that interfered had a negligible effect on the test’s sensitivity. This disposable MIP sensor provides a promising approach for point-of-care testing and facilitating the management of epilepsy. Compared with existing tests, this sensor offers a faster and more accurate way to monitor AEDs, which is crucial for optimizing therapy and improving patient outcomes. Overall, the proposed disposable sensor chip based on MIP-CPs represents a significant advancement in AED monitoring, with the potential for rapid, accurate, and convenient point-of-care testing.
Open AccessDisposable Sensor Chips with Molecularly Imprinted Carbon Paste Electrodes for Monitoring Anti-Epileptic Drugs
Epilepsy is a neurological disorder that affects millions of people worldwide. Anti-epileptic drugs (AEDs) are critical for their management. However, the therapeutic window is narrow, and traditional laboratory-based therapeutic drug monitoring (TDM) methods can be time consuming and unsuitable for point-of-care testing. To address this issue, we developed a disposable sensor chip based on molecularly imprinted polymer-modified carbon paste electrodes (MIP-CPs) for the TDM of AEDs such as phenobarbital (PB), carbamazepine (CBZ), and levetiracetam (LEV). In this work, functional monomers (methacrylic acid) and crosslinking monomers (methylene bisacrylamide and ethylene glycol dimethacrylate) were copolymerized in the presence of the AED template and grafted on the graphite particles by simple radical photopolymerization. The grafted particles were mixed with silicon oil, dissolving ferrocene as a redox marker to make the MIP-carbon paste (CP). Disposable sensor chips were fabricated by packing the MIP-CP into the base made of poly (ethylene glycol terephthalate) (PET) film. The sensor’s sensitivity was determined using differential pulse voltammetry (DPV), carried out on a single sensor chip for each operation. Linearity was obtained from 0–60 μg/mL in PB and LEV and 0–12 μg/mL in CBZ, covering their respective therapeutic range. The time taken for each measurement was around 2 min. The experiment using whole bovine blood and bovine plasma indicated that the existence of species that interfered had a negligible effect on the test’s sensitivity. This disposable MIP sensor provides a promising approach for point-of-care testing and facilitating the management of epilepsy. Compared with existing tests, this sensor offers a faster and more accurate way to monitor AEDs, which is crucial for optimizing therapy and improving patient outcomes. Overall, the proposed disposable sensor chip based on MIP-CPs represents a significant advancement in AED monitoring, with the potential for rapid, accurate, and convenient point-of-care testing.
- Open Access
- 3 January 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (1) , 212
Synthesis of fluorescent Molecularly Imprinted Polymer Nanoparticles Sensing Small Neurotransmitters with High Selectivity Using Immobilized Templates with Regulated Surface Density
To develop nanosensors to probe neurotransmitters, we synthesized fluorescent-functionalized molecularly imprinted polymeric nanoparticles (fMIP-NPs) using monoamine neurotransmitters (serotonin and dopamine) immobilized on glass beads as templates. The size and fluorescence intensity of the fMIP-NPs synthesized with blended silane couplers increased with the presence of the target but were insensitive to the target analogs (L-tryptophan and L-dopa, respectively). However, when the template is anchored by a pure silane agent, both the fluorescence intensity and particle size of the fMIP-NPs were sensitive to the structural analog of the template. Another fMIP-NP was synthesized in the presence of poly([2-(methacryloyloxy)ethyl] trimethylammonium chloride (METMAC)-co-methacrylamide) grafted onto glass beads as a dummy template for acetylcholine. Acetylcholine increased the diameter and fluorescence intensity of the fMIP-NP, but choline had no effect. When the homopolymer of METMAC was used as a template, the fluorescence intensity and size of the resulting nanoparticles were not responsive to either acetylcholine or choline. The principle of increased fluorescence intensity due to specific interaction with the target substance is probably due to the increased distance between the fluorescent functional groups and decreased self-quenching due to the swelling caused by the specific interaction with the template. The results also indicate that MIP nanoparticles prepared by solid-phase synthesis can be used for targeting small molecules, such as the neurotransmitters addressed in this study, by adjusting the surface density of the template.
- 3 January 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (1) , 212
Open AccessSynthesis of fluorescent Molecularly Imprinted Polymer Nanoparticles Sensing Small Neurotransmitters with High Selectivity Using Immobilized Templates with Regulated Surface Density
To develop nanosensors to probe neurotransmitters, we synthesized fluorescent-functionalized molecularly imprinted polymeric nanoparticles (fMIP-NPs) using monoamine neurotransmitters (serotonin and dopamine) immobilized on glass beads as templates. The size and fluorescence intensity of the fMIP-NPs synthesized with blended silane couplers increased with the presence of the target but were insensitive to the target analogs (L-tryptophan and L-dopa, respectively). However, when the template is anchored by a pure silane agent, both the fluorescence intensity and particle size of the fMIP-NPs were sensitive to the structural analog of the template. Another fMIP-NP was synthesized in the presence of poly([2-(methacryloyloxy)ethyl] trimethylammonium chloride (METMAC)-co-methacrylamide) grafted onto glass beads as a dummy template for acetylcholine. Acetylcholine increased the diameter and fluorescence intensity of the fMIP-NP, but choline had no effect. When the homopolymer of METMAC was used as a template, the fluorescence intensity and size of the resulting nanoparticles were not responsive to either acetylcholine or choline. The principle of increased fluorescence intensity due to specific interaction with the target substance is probably due to the increased distance between the fluorescent functional groups and decreased self-quenching due to the swelling caused by the specific interaction with the template. The results also indicate that MIP nanoparticles prepared by solid-phase synthesis can be used for targeting small molecules, such as the neurotransmitters addressed in this study, by adjusting the surface density of the template.
- 9 October 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-02 (61) , 2236
(Digital Presentation) A Disposable Chip Sensor for the Detection of Vancomycin: Studying the Long-Term Stability
Vancomycin is one of the most important anti-bacterial drugs for the treatment of MRSA infection. Continuous monitoring is commonly recommended as it has a low therapeutic window, which is often limited by the equipment cost, and the technical skills required for modern TDM techniques such as HP-LCs and immunoassays. As a result, a cost-effective and quick detection solution for Vancomycin TDM is critical. We have already reported a successful vancomycin sensor on a ceramic base, a paper base, and a PET (polyethylene terephthalate) base, in our previous works 1,2. However, the long-term stability of the sensor for the clinical trial is very important. Therefore, this study focused on the improvement of the stability of the sensor. The PET chip is composed of a PET base on which the silver wiring was printed using an inkjet printer. It contains two holes for electrodes with a 2.0 mm diameter for the counter electrode and a 1.0 mm diameter for the working electrode. The chip also comprises a circular reservoir of diameter 8 mm. VCM imprinted poly(methylene bisacrylamide-co-methacrylic acid-co-Allylaminocarboxypropyonic-3-ferrocene) was grafted on graphite particle surface by a procedure similar to our previous work. This grafted graphite was mixed with a) silicon oil (MIPsi ), and b) paraffin oil (MIPpff ) to make a paste to use as the sensing material. The viscosity of both the oils was the same. We performed the chronoamperometric analysis with a VCM sample solution (0-60 µgmL-1, in phosphate buffer) filled in the sample reservoir. The chronoamperometric analysis time was 15 seconds for each sample. Current obtained at the 10th second was recorded to obtain the calibration curve. The change in current at 10s demonstrated strong linearity with the VCM concentration in both MIPsi and MIPpff , indicating good linearity with the change in current at 10s. Furthermore, this result was obtained using a "single-use" chip, which implies that each concentration was measured using a separate chip. MIPsi and MIPpff were both sensitive to vancomycin. However, when the sensor was packed and kept for 3 days, the MIPsi sensor lost its sensitivity completely. Sensor with the working electrode made of MIPpff, however, retained their sensitivity. MIPpff was further packed and kept for 10 days to have a deeper insight into the effect of binder oil on the long-term stability of the sensor and the sensor was still found to be sensitive. From the results of this study, it can be concluded that a stable sensor that can sensitively detect vancomycin can be made using paraffin oil as the binder oil. References Aaryashree, A., Takeda, Y., Yoshimi, Y., Hatano, A. & Kida, M. A Disposable Vancomycin Sensor Using Molecularly Imprinted Carbon Paste on a Ceramic Chip. in ECS Meeting Abstracts vols MA2020-02 3332–3332 (2020). Aaryashree et al. A “Single-Use” Ceramic-Based Electrochemical Sensor Chip Using Molecularly Imprinted Carbon Paste Electrode. Sensors 20, 5847 (2020).
- 9 October 2022
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2022-02 (61) , 2236
(Digital Presentation) A Disposable Chip Sensor for the Detection of Vancomycin: Studying the Long-Term Stability
Vancomycin is one of the most important anti-bacterial drugs for the treatment of MRSA infection. Continuous monitoring is commonly recommended as it has a low therapeutic window, which is often limited by the equipment cost, and the technical skills required for modern TDM techniques such as HP-LCs and immunoassays. As a result, a cost-effective and quick detection solution for Vancomycin TDM is critical. We have already reported a successful vancomycin sensor on a ceramic base, a paper base, and a PET (polyethylene terephthalate) base, in our previous works 1,2. However, the long-term stability of the sensor for the clinical trial is very important. Therefore, this study focused on the improvement of the stability of the sensor. The PET chip is composed of a PET base on which the silver wiring was printed using an inkjet printer. It contains two holes for electrodes with a 2.0 mm diameter for the counter electrode and a 1.0 mm diameter for the working electrode. The chip also comprises a circular reservoir of diameter 8 mm. VCM imprinted poly(methylene bisacrylamide-co-methacrylic acid-co-Allylaminocarboxypropyonic-3-ferrocene) was grafted on graphite particle surface by a procedure similar to our previous work. This grafted graphite was mixed with a) silicon oil (MIPsi ), and b) paraffin oil (MIPpff ) to make a paste to use as the sensing material. The viscosity of both the oils was the same. We performed the chronoamperometric analysis with a VCM sample solution (0-60 µgmL-1, in phosphate buffer) filled in the sample reservoir. The chronoamperometric analysis time was 15 seconds for each sample. Current obtained at the 10th second was recorded to obtain the calibration curve. The change in current at 10s demonstrated strong linearity with the VCM concentration in both MIPsi and MIPpff , indicating good linearity with the change in current at 10s. Furthermore, this result was obtained using a "single-use" chip, which implies that each concentration was measured using a separate chip. MIPsi and MIPpff were both sensitive to vancomycin. However, when the sensor was packed and kept for 3 days, the MIPsi sensor lost its sensitivity completely. Sensor with the working electrode made of MIPpff, however, retained their sensitivity. MIPpff was further packed and kept for 10 days to have a deeper insight into the effect of binder oil on the long-term stability of the sensor and the sensor was still found to be sensitive. From the results of this study, it can be concluded that a stable sensor that can sensitively detect vancomycin can be made using paraffin oil as the binder oil. References Aaryashree, A., Takeda, Y., Yoshimi, Y., Hatano, A. & Kida, M. A Disposable Vancomycin Sensor Using Molecularly Imprinted Carbon Paste on a Ceramic Chip. in ECS Meeting Abstracts vols MA2020-02 3332–3332 (2020). Aaryashree et al. A “Single-Use” Ceramic-Based Electrochemical Sensor Chip Using Molecularly Imprinted Carbon Paste Electrode. Sensors 20, 5847 (2020).
- Open Access
A Disposable Sensor Chip Using a Paste Electrode with Surface-Imprinted Graphite Particles for Rapid and Reagentless Monitoring of Theophylline
This work focuses on a carbon-based imprinted polymer composite, employed as a molecular recognition and sensing interface in fabricating a disposable electrochemical sensor. The carbon-paste electrode was made of a molecularly imprinted polymer comprising a copolymer of methacrylic acid as the functional monomer and blended crosslinking monomers of N,N′-methylenebisacrylamide, and ethylene glycol dimethacrylate, with theophylline as the template. The analytical properties of the proposed theophylline sensor were investigated, and the findings revealed an increase in differential pulse voltammetric current compared to the non-imprinted electrode. Under optimized conditions, the sensor has shown high sensitivity, high selectivity, lower detection limit (2.5 µg/mL), and satisfactory long-term stability. Further, the sensor was tested in whole bovine blood and validated without any matrix effect and cross-reactivity. Additionally, chronoamperometry of the sensor chip supported a rapid determination of THO with a short response time of 3 s. This carbon-paste electrode is highly specific for theophylline and may be applied as a drug sensor for clinical use.
Open AccessA Disposable Sensor Chip Using a Paste Electrode with Surface-Imprinted Graphite Particles for Rapid and Reagentless Monitoring of Theophylline
This work focuses on a carbon-based imprinted polymer composite, employed as a molecular recognition and sensing interface in fabricating a disposable electrochemical sensor. The carbon-paste electrode was made of a molecularly imprinted polymer comprising a copolymer of methacrylic acid as the functional monomer and blended crosslinking monomers of N,N′-methylenebisacrylamide, and ethylene glycol dimethacrylate, with theophylline as the template. The analytical properties of the proposed theophylline sensor were investigated, and the findings revealed an increase in differential pulse voltammetric current compared to the non-imprinted electrode. Under optimized conditions, the sensor has shown high sensitivity, high selectivity, lower detection limit (2.5 µg/mL), and satisfactory long-term stability. Further, the sensor was tested in whole bovine blood and validated without any matrix effect and cross-reactivity. Additionally, chronoamperometry of the sensor chip supported a rapid determination of THO with a short response time of 3 s. This carbon-paste electrode is highly specific for theophylline and may be applied as a drug sensor for clinical use.
- Open Access
Reagentless Sensing of Vancomycin Using an Indium Tin Oxide Electrode Grafted with Molecularly Imprinted Polymer including Ferrocenyl Group
Vancomycin (VCM) is a first-line antimicrobial agent against methicillin-resistant Staphylococcus aureus, a cause of nosocomial infections. Therapeutic drug monitoring is strongly recommended for VCM-based chemotherapy. The authors attempted to develop a simple VCM sensor based on molecularly imprinted polymer (MIP), which can be used with simple operations. Methacrylic acid (MAA), acrylamide, methylenebisacrylamide, and allylamine carboxypropionate-3-ferrocene (ACPF) were copolymerized in the presence of VCM and grafted from the surface of indium-tin oxide (ITO) to obtain MIP-coated electrodes. The MIP-grafted ITO electrode was used for differential pulse voltammetry (DPV) measurements in a buffer solution containing VCM or whole bovine blood. The obtained current depends on the VCM concentration with high linearity. The dynamic range covered the therapeutic range (20–40 μg/mL) of the VCM but was almost insensitive to teicoplanin, which has a similar structure to VCM. The ITO electrodes grafted by the same procedure except for omitting either VCM or APCF were not sensitive to VCM. The sensitivity of the MIP electrodes to VCM in whole blood and buffered saline, but the background current in blood was higher than that in saline. This high background current was also seen in the deproteinized plasma. Thus, the current is probably originated from the oxidation of low molecular weight reducing agents in the blood. The MIP-grafted ITO electrode using ACPF as a functional monomer would be a promising highly selective sensor for real-time monitoring of VCM with proper correction of the background current.
Open AccessReagentless Sensing of Vancomycin Using an Indium Tin Oxide Electrode Grafted with Molecularly Imprinted Polymer including Ferrocenyl Group
Vancomycin (VCM) is a first-line antimicrobial agent against methicillin-resistant Staphylococcus aureus, a cause of nosocomial infections. Therapeutic drug monitoring is strongly recommended for VCM-based chemotherapy. The authors attempted to develop a simple VCM sensor based on molecularly imprinted polymer (MIP), which can be used with simple operations. Methacrylic acid (MAA), acrylamide, methylenebisacrylamide, and allylamine carboxypropionate-3-ferrocene (ACPF) were copolymerized in the presence of VCM and grafted from the surface of indium-tin oxide (ITO) to obtain MIP-coated electrodes. The MIP-grafted ITO electrode was used for differential pulse voltammetry (DPV) measurements in a buffer solution containing VCM or whole bovine blood. The obtained current depends on the VCM concentration with high linearity. The dynamic range covered the therapeutic range (20–40 μg/mL) of the VCM but was almost insensitive to teicoplanin, which has a similar structure to VCM. The ITO electrodes grafted by the same procedure except for omitting either VCM or APCF were not sensitive to VCM. The sensitivity of the MIP electrodes to VCM in whole blood and buffered saline, but the background current in blood was higher than that in saline. This high background current was also seen in the deproteinized plasma. Thus, the current is probably originated from the oxidation of low molecular weight reducing agents in the blood. The MIP-grafted ITO electrode using ACPF as a functional monomer would be a promising highly selective sensor for real-time monitoring of VCM with proper correction of the background current.