Mohammed Fakhro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammed Fakhro has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Sandra Lindstedt
Department of Clinical Sciences, Lund University, Lund, Sweden
7 shared publications - Lars Algotsson
Department of Cardiothoracic Anaesthesia and Intensive Care, Skane University Hospital, Lund University, Lund, Sweden
3 shared publications - Malin Malmsjö
Department of Clinical Sciences Lund, Ophthalmology, Skåne University Hospital Lund University Lund Sweden
3 shared publications - Leif Pierre
Department of Cardiothoracic Surgery, Skåne University Hospital, Lund University, Lund, Sweden
2 shared publications - Richard Ingemansson
Department of Cardiothoracic Surgery, Skåne University Hospital, Lund University, Lund, Sweden
2 shared publications Ann-Christin Nilsson
Department of Cardiothoracic Surgery and Transplantation, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
1 shared publication
Latest Publications
- Open Access
Refining Risk Stratification and Surveillance Strategies in Pleuropulmonary Solitary Fibrous Tumors—An International, Retrospective, Multicenter Analysis
Background: Solitary fibrous tumor of the pleura are rare neoplasms, and follow-up protocol is lacking. Various risk stratification systems have been proposed to predict recurrence. The aim of this study is to evaluate common risk scores and risk factors leading to a recommendation for follow-up frequency. Methods: We pooled data as part of a multicenter international study with the participation of eight centers in Germany, Switzerland, Denmark, and Austria. Kaplan–Meier survival-curves were used comparing several risk stratification system(s). A Log-rank test was performed to analyze prognostic clinical and pathological factors affecting overall and recurrence-free survival. Results: We included 155 patients from 2004 to 2024: 52.3% were male, median age was 64 years (range 32 to 89). Recurrence rate was 17.4% with median recurrence-free survival of 131 months. Mean time to recurrence was 64.4 (range 9–151) months. Analysis showed that age, tumor morphology, necrosis, and increased mitotic activity were independent prognostic factors for RFS. Conclusions: The WHO risk stratification system demonstrated the highest discriminatory power for recurrence-free survival in the Kaplan–Meier analyses, indicating that the WHO classification remains the most accurate predictor to date. We modified the commonly used risk systems to achieve improved stratification into low-, intermediate- and high-risk groups. The occurrence of late recurrences underscores the need for long-term follow-up.
Open AccessRefining Risk Stratification and Surveillance Strategies in Pleuropulmonary Solitary Fibrous Tumors—An International, Retrospective, Multicenter Analysis
Background: Solitary fibrous tumor of the pleura are rare neoplasms, and follow-up protocol is lacking. Various risk stratification systems have been proposed to predict recurrence. The aim of this study is to evaluate common risk scores and risk factors leading to a recommendation for follow-up frequency. Methods: We pooled data as part of a multicenter international study with the participation of eight centers in Germany, Switzerland, Denmark, and Austria. Kaplan–Meier survival-curves were used comparing several risk stratification system(s). A Log-rank test was performed to analyze prognostic clinical and pathological factors affecting overall and recurrence-free survival. Results: We included 155 patients from 2004 to 2024: 52.3% were male, median age was 64 years (range 32 to 89). Recurrence rate was 17.4% with median recurrence-free survival of 131 months. Mean time to recurrence was 64.4 (range 9–151) months. Analysis showed that age, tumor morphology, necrosis, and increased mitotic activity were independent prognostic factors for RFS. Conclusions: The WHO risk stratification system demonstrated the highest discriminatory power for recurrence-free survival in the Kaplan–Meier analyses, indicating that the WHO classification remains the most accurate predictor to date. We modified the commonly used risk systems to achieve improved stratification into low-, intermediate- and high-risk groups. The occurrence of late recurrences underscores the need for long-term follow-up.
- Open Access
- 31 March 2021
- Published by Wiley in Evidence-Based Complementary and Alternative Medicine
- Vol. 2021, 1-9
Aged Garlic Extract Reduces IL-6: A Double-Blind Placebo-Controlled Trial in Females with a Low Risk of Cardiovascular Disease
Background. Chronic inflammation is a risk factor for cardiovascular disease. The aim of the study was to evaluate whether a daily supplementation of aged garlic extract (AGE) could reduce inflammation in females with low risk for cardiovascular disease. The study was conducted at a single center, as a parallel randomized placebo-controlled trial. Method. 63 females with a Framingham risk score over 10 underwent cardiac computed tomography (CT) scan. Of those, patients with a coronary artery calcium (CAC) scores less than 5 (n = 31) met the inclusion criteria and were randomized, in a double-blind manner to an intake of placebo or AGE (2400 mg daily) for 1 year. Results. Main outcome measure was changes in inflammatory biomarkers, blood pressure, fastening blood glucose, and blood lipids. A total of 29 patients (14 in the AGE group and 15 in the placebo group) completed the study and were analyzed. Females treated with AGE showed lower levels of inflammatory marker IL-6 after 12 months of treatment compared to females receiving placebo ( ). The blood lipids had a trend towards a lowering effect in females treated with AGE; however, this trend was not significant. Conclusion. The present study concludes that AGE lowers IL-6 in females with a risk profile of cardiovascular disease. We could also conclude that risk prediction with cardiac CT scan turned out to be superior in estimating the risk of cardiac disease compared to Framingham risk score. This trial is registered with NCT03860350.
- 31 March 2021
- Published by Wiley in Evidence-Based Complementary and Alternative Medicine
- Vol. 2021, 1-9
Open AccessAged Garlic Extract Reduces IL-6: A Double-Blind Placebo-Controlled Trial in Females with a Low Risk of Cardiovascular Disease
Background. Chronic inflammation is a risk factor for cardiovascular disease. The aim of the study was to evaluate whether a daily supplementation of aged garlic extract (AGE) could reduce inflammation in females with low risk for cardiovascular disease. The study was conducted at a single center, as a parallel randomized placebo-controlled trial. Method. 63 females with a Framingham risk score over 10 underwent cardiac computed tomography (CT) scan. Of those, patients with a coronary artery calcium (CAC) scores less than 5 (n = 31) met the inclusion criteria and were randomized, in a double-blind manner to an intake of placebo or AGE (2400 mg daily) for 1 year. Results. Main outcome measure was changes in inflammatory biomarkers, blood pressure, fastening blood glucose, and blood lipids. A total of 29 patients (14 in the AGE group and 15 in the placebo group) completed the study and were analyzed. Females treated with AGE showed lower levels of inflammatory marker IL-6 after 12 months of treatment compared to females receiving placebo ( ). The blood lipids had a trend towards a lowering effect in females treated with AGE; however, this trend was not significant. Conclusion. The present study concludes that AGE lowers IL-6 in females with a risk profile of cardiovascular disease. We could also conclude that risk prediction with cardiac CT scan turned out to be superior in estimating the risk of cardiac disease compared to Framingham risk score. This trial is registered with NCT03860350.
- Open Access
- 23 June 2020
- Published by Taylor & Francis in Scandinavian Cardiovascular Journal
- Vol. 54 (5) , 322-329
Impact of allograft ischemic time on long-term survival in lung transplantation: a Swedish monocentric study
Purpose: The influence of allograft ischemic time (IT) on short- and long-term mortality remains under debate in lung transplantation (LTx). Due to a scarcity in donors, better understanding of IT might improve the outcome after LTx. Methods: Between January 1990 and June 2016; 307 patients underwent LTx at Lund university hospital, Sweden. The end-point used was death/Re-LTx assessed by Cox regression and Kaplan–Meier survival. Results: Kaplan–Meier survival for mean IT (min) between subgroups ≤120, 121–240, 241–360 and 361+ showed significant difference for pairwise-comparisons with superior outcome for IT between ≤120 and 240 min. Cox regression analyses for each hour of IT in patients with a limited survival up to 1- and 5-year had a hazard ratio (HR) of 1.119 and 1.063 respectively (p < .05). Conclusions: In LTx, every 2-hour increase of IT is equivalent to an increased mortality of up to 24% within 5 years. LTx with an IT of ≤120 min had a superior survival in both 1- and 5 years in comparison to an IT of up to 360 min. Better application of IT provides a key role in improving LTx outcome.
- 23 June 2020
- Published by Taylor & Francis in Scandinavian Cardiovascular Journal
- Vol. 54 (5) , 322-329
Open AccessImpact of allograft ischemic time on long-term survival in lung transplantation: a Swedish monocentric study
Purpose: The influence of allograft ischemic time (IT) on short- and long-term mortality remains under debate in lung transplantation (LTx). Due to a scarcity in donors, better understanding of IT might improve the outcome after LTx. Methods: Between January 1990 and June 2016; 307 patients underwent LTx at Lund university hospital, Sweden. The end-point used was death/Re-LTx assessed by Cox regression and Kaplan–Meier survival. Results: Kaplan–Meier survival for mean IT (min) between subgroups ≤120, 121–240, 241–360 and 361+ showed significant difference for pairwise-comparisons with superior outcome for IT between ≤120 and 240 min. Cox regression analyses for each hour of IT in patients with a limited survival up to 1- and 5-year had a hazard ratio (HR) of 1.119 and 1.063 respectively (p < .05). Conclusions: In LTx, every 2-hour increase of IT is equivalent to an increased mortality of up to 24% within 5 years. LTx with an IT of ≤120 min had a superior survival in both 1- and 5 years in comparison to an IT of up to 360 min. Better application of IT provides a key role in improving LTx outcome.
- Open Access
- 9 October 2019
- Published by IntechOpen
Lung Transplantation: A Final Option for End-Stage Interstitial Lung Diseases
Lung transplantation (LTx) is an established, well-recognized medical intervention for treating patients with an end-stage irreversible pulmonary disease. Such diseases include interstitial lung disease (ILD), where other standard medical options often have been proven as insufficient. Post-operative survival after LTx depends on various factors such as the general and organ-specific recipient status in addition to donor organ condition and operative technique. The prolonged survival rates obtained during the 1980s and 1990s have established LTx in the medical field. Reflecting the improvements made in the field of organ preservation, operative technique, immunosuppressants, recipient and donor organ selection and prophylactic as well as direct treatment in the wide spectrum of possible infections in the recipient. Despite LTx being the golden standard for treating end-stage irreversible ILD, with idiopathic pulmonary fibrosis (IPF) as the most common cause, post-operative outcome is greatly hampered compared to the outcome of other patient categories within LTx. This chapter will provide insight in the outcome of ILD and subsequently IFP after LTx.
- 9 October 2019
- Published by IntechOpen
Open AccessLung Transplantation: A Final Option for End-Stage Interstitial Lung Diseases
Lung transplantation (LTx) is an established, well-recognized medical intervention for treating patients with an end-stage irreversible pulmonary disease. Such diseases include interstitial lung disease (ILD), where other standard medical options often have been proven as insufficient. Post-operative survival after LTx depends on various factors such as the general and organ-specific recipient status in addition to donor organ condition and operative technique. The prolonged survival rates obtained during the 1980s and 1990s have established LTx in the medical field. Reflecting the improvements made in the field of organ preservation, operative technique, immunosuppressants, recipient and donor organ selection and prophylactic as well as direct treatment in the wide spectrum of possible infections in the recipient. Despite LTx being the golden standard for treating end-stage irreversible ILD, with idiopathic pulmonary fibrosis (IPF) as the most common cause, post-operative outcome is greatly hampered compared to the outcome of other patient categories within LTx. This chapter will provide insight in the outcome of ILD and subsequently IFP after LTx.
- Open Access
- 1 July 2019
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 14 (1) , 1-8
Ten year follow-up of lung transplantations using initially rejected donor lungs after reconditioning using ex vivo lung perfusion
In 2006 and 2007 we performed double lung transplantation with marginal donor lungs assessed and reconditioned by Ex Vivo Lung Perfusion (EVLP), using a technique developed by Professor Stig Steen. Here we present a 10-year follow-up comparing the outcomes of lung transplantations performed at our clinic using EVLP lungs vs. conventional lungs. Between 2006 and 2007, 21 patients (6 EVLP, 15 conventional) underwent double lung transplantation (LTx) with follow-up on May 2017 at Lund University Hospital, Sweden. Pulmonary function was measured at 3/6/12 months, and annually thereafter for a period of 10 years in addition to survival and freedom from chronic lung allograft dysfunction (CLAD) being analyzed. Regarding Forced Expiratory Volume in 1 s (FEV1) and 6MWT at 3, 6, and 12 months and annually thereafter, no difference in median FEV1 nor 6MWT was found for EVLP-LTx vs. conventional-LTx (p > 0.05). No difference was shown in post-operative survival between EVLP-LTx vs. conventional LTx for patients with an overall survival up to 10-years (p > 0.05). The same pattern was shown in sub analyses for patients with a limited survival up to 1 and 5 years (p > 0.05). No superiority was found in conventional-LTx over EVLP-LTx, neither in long-term survival nor pulmonary function. No difference in CLAD-free survival was seen between the two groups. We believe that EVLP is a safe and effective method to use in LTx, greatly increasing the donor pool by improving marginal lungs and providing an objective assessment of the viability of marginal donor lungs.
- 1 July 2019
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 14 (1) , 1-8
Open AccessTen year follow-up of lung transplantations using initially rejected donor lungs after reconditioning using ex vivo lung perfusion
In 2006 and 2007 we performed double lung transplantation with marginal donor lungs assessed and reconditioned by Ex Vivo Lung Perfusion (EVLP), using a technique developed by Professor Stig Steen. Here we present a 10-year follow-up comparing the outcomes of lung transplantations performed at our clinic using EVLP lungs vs. conventional lungs. Between 2006 and 2007, 21 patients (6 EVLP, 15 conventional) underwent double lung transplantation (LTx) with follow-up on May 2017 at Lund University Hospital, Sweden. Pulmonary function was measured at 3/6/12 months, and annually thereafter for a period of 10 years in addition to survival and freedom from chronic lung allograft dysfunction (CLAD) being analyzed. Regarding Forced Expiratory Volume in 1 s (FEV1) and 6MWT at 3, 6, and 12 months and annually thereafter, no difference in median FEV1 nor 6MWT was found for EVLP-LTx vs. conventional-LTx (p > 0.05). No difference was shown in post-operative survival between EVLP-LTx vs. conventional LTx for patients with an overall survival up to 10-years (p > 0.05). The same pattern was shown in sub analyses for patients with a limited survival up to 1 and 5 years (p > 0.05). No superiority was found in conventional-LTx over EVLP-LTx, neither in long-term survival nor pulmonary function. No difference in CLAD-free survival was seen between the two groups. We believe that EVLP is a safe and effective method to use in LTx, greatly increasing the donor pool by improving marginal lungs and providing an objective assessment of the viability of marginal donor lungs.
- Open Access
- 13 March 2019
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 7 (1) , 16
Different particle flow patterns from the airways after recruitment manoeuvres using volume-controlled or pressure-controlled ventilation
Noninvasive online monitoring of different particle flows from the airways may serve as an additional tool to assess mechanical ventilation. In the present study, we used a customised PExA, an optical particle counter for monitoring particle flow and size distribution in exhaled air, to analyse airway particle flow for three subsequent days. We compared volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) and performed recruitment manoeuvres (RM). Six animals were randomised into two groups: half received VCV before PCV and the other half received PCV before VCV. Measurements were taken daily for 1 h in each mode during three subsequent days in six fully anaesthetised domestic pigs. A RM was performed twice daily for 60 s at positive end-expiratory pressure (PEEP) of 10, 4 breaths/min and inspiratory-expiratory ratio (I:E) of 2:1. Measurements were taken for 3 min before the RM, 1 min during the RM and for 3 min after the RM. The particle sizes measured were between 0.48 and 3.37 μm. A significant stepwise decrease was observed in total particle count from day 1 to day 3, and at the same time, an increase in fluid levels was seen. Comparing VCV to PCV, a significant increase in total particle count was observed on day 2, with the highest particle count occurring during VCV. A significant increase was observed comparing before and after RM on day 1 and 2 but not on day 3. One animal developed ARDS and showed a different particle pattern compared to the other animals. This study shows the safety and useability of the PExA technique used in conjunction with mechanical ventilation. We detected differences between the ventilation modes VCV and PCV in total particle count without any significant changes in ventilator pressure levels, FiO2 levels or the animals’ vital parameters. The findings during RM indicate an opening of the small airways, but the effect is short lived. We have also showed that VCV and PCV may affect the lung physiology differently during recruitment manoeuvres. These findings might indicate that this technique may provide more refined information on the impact of mechanical ventilation.
- 13 March 2019
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 7 (1) , 16
Open AccessDifferent particle flow patterns from the airways after recruitment manoeuvres using volume-controlled or pressure-controlled ventilation
Noninvasive online monitoring of different particle flows from the airways may serve as an additional tool to assess mechanical ventilation. In the present study, we used a customised PExA, an optical particle counter for monitoring particle flow and size distribution in exhaled air, to analyse airway particle flow for three subsequent days. We compared volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) and performed recruitment manoeuvres (RM). Six animals were randomised into two groups: half received VCV before PCV and the other half received PCV before VCV. Measurements were taken daily for 1 h in each mode during three subsequent days in six fully anaesthetised domestic pigs. A RM was performed twice daily for 60 s at positive end-expiratory pressure (PEEP) of 10, 4 breaths/min and inspiratory-expiratory ratio (I:E) of 2:1. Measurements were taken for 3 min before the RM, 1 min during the RM and for 3 min after the RM. The particle sizes measured were between 0.48 and 3.37 μm. A significant stepwise decrease was observed in total particle count from day 1 to day 3, and at the same time, an increase in fluid levels was seen. Comparing VCV to PCV, a significant increase in total particle count was observed on day 2, with the highest particle count occurring during VCV. A significant increase was observed comparing before and after RM on day 1 and 2 but not on day 3. One animal developed ARDS and showed a different particle pattern compared to the other animals. This study shows the safety and useability of the PExA technique used in conjunction with mechanical ventilation. We detected differences between the ventilation modes VCV and PCV in total particle count without any significant changes in ventilator pressure levels, FiO2 levels or the animals’ vital parameters. The findings during RM indicate an opening of the small airways, but the effect is short lived. We have also showed that VCV and PCV may affect the lung physiology differently during recruitment manoeuvres. These findings might indicate that this technique may provide more refined information on the impact of mechanical ventilation.
- Open Access
- 28 January 2019
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 14 (1) , 24
ABO-identical matching has no superiority in long-term survival in comparison to ABO-compatible matching in lung transplantation
Even though identical blood group matching between recipient and donor is preferred, it is still not clear by how much this improves the outcome for patients who received a lung transplant (LTx), or whether there is any survival benefit. Earlier studies have yielded ambiguous results and few have investigated long-term survival. The aim of this study is, therefore, to explore the different outcomes of identical and compatible recipient and donor blood group matching to determine whether identical matching is superior (LTx). Between January 1990 to June 2016, 297 patients underwent primary LTx, 10 patients underwent heart and lung transplantation (HLTx), and 18 patients required re-transplantation (Re-LTx) at Skåne University Hospital in Lund. With a total of 325 transplantations at our center, 262 were ABO-identically matched while 53 were ABO-compatible. For survival analyses, the end-point used was retransplantation-free survival in addition to excluding HLTx (n = 10), assessed by Cox regression and Kaplan-Meier. ABO-compatible patients had a median of 49 days (2–641), and ABO-identical patients had a median of 89 days (1–1717) (p = 0.048) on the transplant waiting list. Patients with a limited survival up to 1-year showed significant difference in survival rate for ABO-compatible recipients compared to ABO-identical recipients (p < 0.05), however no significant difference was shown in overall survival between the two groups (p > 0.05), with the same pattern shown in patients with a limited survival rate up to ten years, emphysema-patients, when excluding single-LTx and patients transplanted before 2005 and after 2005, respectively (p > 0.05). Recipients who received ABO-compatible matched grafts showed a similar survival rate to recipients who received ABO-identical matched grafts in the present study. Cytolomegalovirus and Ebstein Barr Virus mismatch were also identified as risk factors particular among emphysema patients. Since ABO-identical transplantations and ABO-compatible transplantations showed similar results, the present selection-bias of preferring ABO-identical lungs could be adjusted to increase organ allocation. It might also be possible to shorten recipient waiting list time, as an identical match showed over 80% higher time on the waiting list than a compatible, non-identical match.
- 28 January 2019
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 14 (1) , 24
Open AccessABO-identical matching has no superiority in long-term survival in comparison to ABO-compatible matching in lung transplantation
Even though identical blood group matching between recipient and donor is preferred, it is still not clear by how much this improves the outcome for patients who received a lung transplant (LTx), or whether there is any survival benefit. Earlier studies have yielded ambiguous results and few have investigated long-term survival. The aim of this study is, therefore, to explore the different outcomes of identical and compatible recipient and donor blood group matching to determine whether identical matching is superior (LTx). Between January 1990 to June 2016, 297 patients underwent primary LTx, 10 patients underwent heart and lung transplantation (HLTx), and 18 patients required re-transplantation (Re-LTx) at Skåne University Hospital in Lund. With a total of 325 transplantations at our center, 262 were ABO-identically matched while 53 were ABO-compatible. For survival analyses, the end-point used was retransplantation-free survival in addition to excluding HLTx (n = 10), assessed by Cox regression and Kaplan-Meier. ABO-compatible patients had a median of 49 days (2–641), and ABO-identical patients had a median of 89 days (1–1717) (p = 0.048) on the transplant waiting list. Patients with a limited survival up to 1-year showed significant difference in survival rate for ABO-compatible recipients compared to ABO-identical recipients (p < 0.05), however no significant difference was shown in overall survival between the two groups (p > 0.05), with the same pattern shown in patients with a limited survival rate up to ten years, emphysema-patients, when excluding single-LTx and patients transplanted before 2005 and after 2005, respectively (p > 0.05). Recipients who received ABO-compatible matched grafts showed a similar survival rate to recipients who received ABO-identical matched grafts in the present study. Cytolomegalovirus and Ebstein Barr Virus mismatch were also identified as risk factors particular among emphysema patients. Since ABO-identical transplantations and ABO-compatible transplantations showed similar results, the present selection-bias of preferring ABO-identical lungs could be adjusted to increase organ allocation. It might also be possible to shorten recipient waiting list time, as an identical match showed over 80% higher time on the waiting list than a compatible, non-identical match.
- Open Access
- 25 November 2017
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 12 (1) , 100
Double lung, unlike single lung transplantation might provide a protective effect on mortality and bronchiolitis obliterans syndrome
Survival after lung transplantation (LTx) is often limited by bronchiolitis obliterans syndrome (BOS). Survey of 278 recipients who underwent LTx. The endpoint used was BOS (BOS grade ≥ 2), death or Re-lung transplantation (Re-LTx) assessed by competing risk regression analyses. The incidence of BOS grade ≥ 2 among double LTx (DLTx) recipients was 16 ± 3% at 5 years, 30 ± 4% at 10 years, and 37 ± 5% at 20 years, compared to single LTx (SLTx) recipients whose corresponding incidence of BOS grade ≥ 2 was 11 ± 3%, 20 ± 4%, and 24 ± 5% at 5, 10, and 20 years, respectively (p > 0. 05). The incidence of BOS grade ≥ 2 by major indications ranked in descending order: other, PF, CF, COPD, PH and AAT1 (p < 0. 05). The mortality rate by major indication ranked in descending order: COPD, PH, AAT1, PF, Other and CF (p < 0. 05). No differences were seen in the incidence of BOS grade ≥ 2 regarding type of transplant, however, DLTx recipients showed a better chance of survival despite developing BOS compared to SLTx recipients. The highest incidence of BOS was seen among CF, PF, COPD, PH, and AAT1 recipients in descending order, however, CF and PF recipients showed a better chance of survival despite developing BOS compared to COPD, PH, and AAT1 recipients.
- 25 November 2017
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 12 (1) , 100
Open AccessDouble lung, unlike single lung transplantation might provide a protective effect on mortality and bronchiolitis obliterans syndrome
Survival after lung transplantation (LTx) is often limited by bronchiolitis obliterans syndrome (BOS). Survey of 278 recipients who underwent LTx. The endpoint used was BOS (BOS grade ≥ 2), death or Re-lung transplantation (Re-LTx) assessed by competing risk regression analyses. The incidence of BOS grade ≥ 2 among double LTx (DLTx) recipients was 16 ± 3% at 5 years, 30 ± 4% at 10 years, and 37 ± 5% at 20 years, compared to single LTx (SLTx) recipients whose corresponding incidence of BOS grade ≥ 2 was 11 ± 3%, 20 ± 4%, and 24 ± 5% at 5, 10, and 20 years, respectively (p > 0. 05). The incidence of BOS grade ≥ 2 by major indications ranked in descending order: other, PF, CF, COPD, PH and AAT1 (p < 0. 05). The mortality rate by major indication ranked in descending order: COPD, PH, AAT1, PF, Other and CF (p < 0. 05). No differences were seen in the incidence of BOS grade ≥ 2 regarding type of transplant, however, DLTx recipients showed a better chance of survival despite developing BOS compared to SLTx recipients. The highest incidence of BOS was seen among CF, PF, COPD, PH, and AAT1 recipients in descending order, however, CF and PF recipients showed a better chance of survival despite developing BOS compared to COPD, PH, and AAT1 recipients.
- Open Access
- 5 September 2017
- Published by International Scientific Information, Inc. in Annals of Transplantation
- Vol. 22, 532-540
Impact of Forced Expiratory Volume in 1 Second (FEV1) and 6-Minute Walking Distance at 3, 6, and 12 Months and Annually on Survival and Occurrence of Bronchiolitis Obliterans Syndrome (BOS) After Lung Transplantation
BACKGROUND Development of bronchiolitis obliterans syndrome (BOS) is a great limitation for patient survival in lung transplantation (LTx). A curative treatment for BOS is still missing, and in terminal stages re-transplantation (Re-LTx) is the only salvation. It is possible to slow the progress of BOS if it is detected at an early stage. This might be possible by assessing pulmonary function pattern. MATERIAL AND METHODS Between 1990 and 2014, 278 patients underwent LTx at Skåne University Hospital, Sweden. Pulmonary function was followed using spirometry (FEV1) and 6-minute walking test (6MWT) measured at 3, 6, and 12 months and annually. The endpoint used was freedom from BOS (BOS grade ≤1), BOS (BOS grade ≥2), and death or Re-LTx. RESULTS Double-lung transplantation (DLTx) showed a hazard ratio (HR) of 0.514 (p=0.001) versus recipients who underwent single-lung transplantation (SLTx). Regarding freedom from BOS, FEV1 showed an HR of 0.597 and 6MWT an HR of 0.982 (p<0.001). Regarding combined endpoint BOS ≥2 and Re-LTx, FEV1 showed an HR of 0.618 and 6MWT an HR of 0.972 (p<0.001). CONCLUSIONS Recipients with higher FEV1 or 6MWT values had better chances of survival. Recipients with DLTx had a significant survival benefit and a protective effect against development of BOS. As the distance that the patient can walk in 6 minutes increases, risk for death or Re-LTx is significantly lower, as is incidence of developing BOS grade ≥2. Understanding changes within pulmonary function are probably key to understanding patient prognosis.
- 5 September 2017
- Published by International Scientific Information, Inc. in Annals of Transplantation
- Vol. 22, 532-540
Open AccessImpact of Forced Expiratory Volume in 1 Second (FEV1) and 6-Minute Walking Distance at 3, 6, and 12 Months and Annually on Survival and Occurrence of Bronchiolitis Obliterans Syndrome (BOS) After Lung Transplantation
BACKGROUND Development of bronchiolitis obliterans syndrome (BOS) is a great limitation for patient survival in lung transplantation (LTx). A curative treatment for BOS is still missing, and in terminal stages re-transplantation (Re-LTx) is the only salvation. It is possible to slow the progress of BOS if it is detected at an early stage. This might be possible by assessing pulmonary function pattern. MATERIAL AND METHODS Between 1990 and 2014, 278 patients underwent LTx at Skåne University Hospital, Sweden. Pulmonary function was followed using spirometry (FEV1) and 6-minute walking test (6MWT) measured at 3, 6, and 12 months and annually. The endpoint used was freedom from BOS (BOS grade ≤1), BOS (BOS grade ≥2), and death or Re-LTx. RESULTS Double-lung transplantation (DLTx) showed a hazard ratio (HR) of 0.514 (p=0.001) versus recipients who underwent single-lung transplantation (SLTx). Regarding freedom from BOS, FEV1 showed an HR of 0.597 and 6MWT an HR of 0.982 (p<0.001). Regarding combined endpoint BOS ≥2 and Re-LTx, FEV1 showed an HR of 0.618 and 6MWT an HR of 0.972 (p<0.001). CONCLUSIONS Recipients with higher FEV1 or 6MWT values had better chances of survival. Recipients with DLTx had a significant survival benefit and a protective effect against development of BOS. As the distance that the patient can walk in 6 minutes increases, risk for death or Re-LTx is significantly lower, as is incidence of developing BOS grade ≥2. Understanding changes within pulmonary function are probably key to understanding patient prognosis.