Kyu Chang Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kyu Chang Park has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
Jin Jang
Department of Information Display and Advanced Display Research Center, Kyung Hee University, Dongdaemoon-ku, Seoul 130-701, Korea
16 shared publicationsJe Hwang Ryu
Kyung Hee University Department of Information Display and Advanced Display Research Center Seoul 130-701, Korea
9 shared publications- Yi Yin Yu
Department of Information Display, Kyung Hee University , 26, Kyungdae-ro, Dongdaemun-gu, Seoul 02447, Republic of Korea
8 shared publications Jung Su Kang
Department of Information Display and Advanced Display Research Institute, Kyung Hee University , Seoul 130-701, South Korea
6 shared publicationsKi Seo Kim
Department of Physics and Advanced Display Research Center , Kyung Hee University
5 shared publications- Jaydip Sawant
Department of Ocean System Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Republic of Korea
4 shared publications
Latest Publications
- 2 June 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (4)
Fabrication of carbon nanotube-based cold electron source for x-ray battery inspection
High-resolution x-ray imaging under low-voltage conditions is essential for nondestructive evaluation of lithium-ion batteries, where microscale internal defects critically affect safety and long-term performance. However, many previously reported electron emission sources exhibit limitations in beam confinement, particularly under low-voltage or high-current operating conditions, which can restrict imaging resolution and practical applicability. To address these challenges, a newly optimized single-island C-beam x-ray source based on a carbon nanotube (CNT) cold-cathode field emitter is proposed for low-voltage, high-resolution battery inspection. The electron source was optimized through improved electrode geometry and electrostatic focusing, resulting in enhanced beam convergence and reduced focal spot size. Electrical characterization demonstrated reliable operation, delivering a maximum emission current of 1.15 mA in a diode mode and a stable anode current of 0.42 mA in a triode mode. These improvements enabled the formation of a tightly confined focal spot of approximately 32 μm at an anode voltage of 65 kV. Imaging performance was quantitatively validated using line-pair phantoms, confirming a practical spatial resolution of 38.5 μm with contrast-to-noise ratio values ranging from 1.6 to 5.47 under low-dose conditions. The optimized system further achieved high-throughput capability, supporting inspection rates of 300–500 cylindrical cells/min, surpassing conventional low-voltage commercial x-ray systems. The proposed CNT-based C-beam source demonstrates a compact, energy-efficient, and scalable solution for rapid, low-dose, and high-fidelity nondestructive inspection of advanced energy storage devices.
- 2 June 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (4)
Fabrication of carbon nanotube-based cold electron source for x-ray battery inspection
High-resolution x-ray imaging under low-voltage conditions is essential for nondestructive evaluation of lithium-ion batteries, where microscale internal defects critically affect safety and long-term performance. However, many previously reported electron emission sources exhibit limitations in beam confinement, particularly under low-voltage or high-current operating conditions, which can restrict imaging resolution and practical applicability. To address these challenges, a newly optimized single-island C-beam x-ray source based on a carbon nanotube (CNT) cold-cathode field emitter is proposed for low-voltage, high-resolution battery inspection. The electron source was optimized through improved electrode geometry and electrostatic focusing, resulting in enhanced beam convergence and reduced focal spot size. Electrical characterization demonstrated reliable operation, delivering a maximum emission current of 1.15 mA in a diode mode and a stable anode current of 0.42 mA in a triode mode. These improvements enabled the formation of a tightly confined focal spot of approximately 32 μm at an anode voltage of 65 kV. Imaging performance was quantitatively validated using line-pair phantoms, confirming a practical spatial resolution of 38.5 μm with contrast-to-noise ratio values ranging from 1.6 to 5.47 under low-dose conditions. The optimized system further achieved high-throughput capability, supporting inspection rates of 300–500 cylindrical cells/min, surpassing conventional low-voltage commercial x-ray systems. The proposed CNT-based C-beam source demonstrates a compact, energy-efficient, and scalable solution for rapid, low-dose, and high-fidelity nondestructive inspection of advanced energy storage devices.
- 13 March 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (5) , 05SP29
Analysis of beam profile shaping of cold electron beam (C-beam) based EUV light source
Stable and well-controlled extreme-ultraviolet (EUV) light source is crucial for next-generation compact EUV inspection and nanolithography platforms. For stable EUV beam operation requires a well-controlled spatial photon distribution, yet our laboratory EUV systems inherently generate off-axis photon components that lead to beam halos, local over-illumination, and temporal instability. In this work, we present a practical aperture-filtered EUV beam conditioning strategy that suppresses high-angle off-axis photons and reshapes the native emission profile into a cleaner, quasi-Gaussian central beam. By inserting engineered apertures between the EUV generation region and the measurement zone where calibrated EUV photodiodes and sapphire-anode imaging are employed, we achieve suppression of off-axis EUV emission, precise control over the beam profile, and improved short-term stability at a typical operating voltage of 10 kV. Systematic beam-profile measurements show that optimized circular apertures effectively reduce peripheral intensity fluctuations, eliminate halo contributions, and enhance EUV beam temporal reproducibility and intensity operation without relying on diffractive optics or a focusing lens. These findings demonstrate that aperture-driven angular filtering offers a simple, cost-effective, and robust method for improving the quality and stability of C-beam-driven EUV sources, with strong potential for applications in pellicle inspection, mask metrology, and next-generation EUV diagnostics.
- 13 March 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (5) , 05SP29
Analysis of beam profile shaping of cold electron beam (C-beam) based EUV light source
Stable and well-controlled extreme-ultraviolet (EUV) light source is crucial for next-generation compact EUV inspection and nanolithography platforms. For stable EUV beam operation requires a well-controlled spatial photon distribution, yet our laboratory EUV systems inherently generate off-axis photon components that lead to beam halos, local over-illumination, and temporal instability. In this work, we present a practical aperture-filtered EUV beam conditioning strategy that suppresses high-angle off-axis photons and reshapes the native emission profile into a cleaner, quasi-Gaussian central beam. By inserting engineered apertures between the EUV generation region and the measurement zone where calibrated EUV photodiodes and sapphire-anode imaging are employed, we achieve suppression of off-axis EUV emission, precise control over the beam profile, and improved short-term stability at a typical operating voltage of 10 kV. Systematic beam-profile measurements show that optimized circular apertures effectively reduce peripheral intensity fluctuations, eliminate halo contributions, and enhance EUV beam temporal reproducibility and intensity operation without relying on diffractive optics or a focusing lens. These findings demonstrate that aperture-driven angular filtering offers a simple, cost-effective, and robust method for improving the quality and stability of C-beam-driven EUV sources, with strong potential for applications in pellicle inspection, mask metrology, and next-generation EUV diagnostics.
- 16 January 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (6)
Extreme ultraviolet light source with cold cathode electron beam using silicon solid target
We report on the significant enhancement of extreme ultraviolet (EUV) light power with a cold cathode electron-beam by substituting the conventional Tin (Sn) excitation anode with a solid silicon (Si) target. Conventionally, solid anode for EUV generation would be very difficult to apply the high input power for EUV generation due to debris generation. To obtain higher EUV power, we should consider on the anode power thermal load to enhance EUV photon power. Consequently, we achieved a 4-fold increase in the absolute EUV photon current compared to the maximum output obtainable from the solid Sn target. This result suggests that for compact, solid-target-based EUV sources, the target's capability to withstand high input power is a more critical factor for total brightness than the atomic emission efficiency alone
- 16 January 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (6)
Extreme ultraviolet light source with cold cathode electron beam using silicon solid target
We report on the significant enhancement of extreme ultraviolet (EUV) light power with a cold cathode electron-beam by substituting the conventional Tin (Sn) excitation anode with a solid silicon (Si) target. Conventionally, solid anode for EUV generation would be very difficult to apply the high input power for EUV generation due to debris generation. To obtain higher EUV power, we should consider on the anode power thermal load to enhance EUV photon power. Consequently, we achieved a 4-fold increase in the absolute EUV photon current compared to the maximum output obtainable from the solid Sn target. This result suggests that for compact, solid-target-based EUV sources, the target's capability to withstand high input power is a more critical factor for total brightness than the atomic emission efficiency alone
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (2) , 1008-1014
Carbon Nanotube-Based Cold Electron Beam (C-Beam) EUV Source for CNT Membrane Inspection
Extreme ultraviolet (EUV) lithography continues to drive progress in semiconductor fabrication by enabling patterning of structures smaller than 7 nm. However, contamination and debris during EUV exposure remain a significant challenge. To enhance production efficiency and device yield, it is essential to maintain clean patterning conditions. A crucial element in achieving this is the implementation of high-transmission pellicles, which serve to prevent contaminating particles from reaching the focal plane. By doing so, these pellicles significantly reduce the risk of imaging defects caused by particle interference. In this work, we present a novel debris-free EUV light source based on carbon nanotube (CNT) cold cathode electron beam emission designed specifically for pellicle inspection applications. The system generates EUV radiation by directing electron beams onto a tin (Sn) anode, achieving high-intensity, narrowband EUV light output without plasma generation or particle contamination. This compact and low-power EUV system enables reliable, high-precision measurement of pellicle transmission characteristics, even for ultrathin membranes. Three CNT-based pellicle samples were systematically evaluated under consistent operating conditions. Among these, Sample H demonstrated the highest transmittance of 94.25% $\pm ~0.40$ % confirming the method’s suitability for precise performance evaluation of ultrathin EUV pellicles. These experimental results confirm the utility of the cold cathode-based electron beam (C-beam) source for quantitative EUV pellicle characterization. This work offers a scalable pathway for laboratory-scale, high-resolution EUV metrology essential to next-generation lithography.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (2) , 1008-1014
Carbon Nanotube-Based Cold Electron Beam (C-Beam) EUV Source for CNT Membrane Inspection
Extreme ultraviolet (EUV) lithography continues to drive progress in semiconductor fabrication by enabling patterning of structures smaller than 7 nm. However, contamination and debris during EUV exposure remain a significant challenge. To enhance production efficiency and device yield, it is essential to maintain clean patterning conditions. A crucial element in achieving this is the implementation of high-transmission pellicles, which serve to prevent contaminating particles from reaching the focal plane. By doing so, these pellicles significantly reduce the risk of imaging defects caused by particle interference. In this work, we present a novel debris-free EUV light source based on carbon nanotube (CNT) cold cathode electron beam emission designed specifically for pellicle inspection applications. The system generates EUV radiation by directing electron beams onto a tin (Sn) anode, achieving high-intensity, narrowband EUV light output without plasma generation or particle contamination. This compact and low-power EUV system enables reliable, high-precision measurement of pellicle transmission characteristics, even for ultrathin membranes. Three CNT-based pellicle samples were systematically evaluated under consistent operating conditions. Among these, Sample H demonstrated the highest transmittance of 94.25% $\pm ~0.40$ % confirming the method’s suitability for precise performance evaluation of ultrathin EUV pellicles. These experimental results confirm the utility of the cold cathode-based electron beam (C-beam) source for quantitative EUV pellicle characterization. This work offers a scalable pathway for laboratory-scale, high-resolution EUV metrology essential to next-generation lithography.
- 1 January 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (1)
Optimization and performance enhancement of single island carbon nanotube electron beams for microscopy application
This study explores the influence of island diameter, shape, and emitter density on the performance of vertically aligned carbon nanotube (VACNT) cold cathodes for high-resolution electron microscopy applications. VACNT arrays with varying island diameters (small, medium, and large) and shapes (hexagonal and square) were fabricated to evaluate their impact on electron field emission. The effect of increasing emitter density within a fixed area was also analyzed. Smaller island diameters produced stronger localized electric fields, enhancing current density, while hexagonal shapes provided better beam focusing with reduced divergence. Increased emitter density improved total current output and emission stability. Optimized electron beam emission currents of 650 and 120 μA were achieved for diode and triode structures, respectively, using a hexagonal design with 19 emitters and a 23 μm diameter. The optimized emitters demonstrated exceptional performance, with a high current density of 1.2 × 106 A/m2 and a beam brightness of 1.8 × 108 A/m2 sr V. Additionally, the emitters exhibited a minimal beam divergence angle of 1.02°, ensuring precision and focus on electron beam applications. These results highlight the potential of the developed electron beam system for advanced applications requiring high-intensity, stable, and precise electron sources. These findings underscore the importance of optimizing geometric parameters to enhance electron beam performance, advancing VACNT-based electron sources for microscopy and other precision technologies.
- 1 January 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (1)
Optimization and performance enhancement of single island carbon nanotube electron beams for microscopy application
This study explores the influence of island diameter, shape, and emitter density on the performance of vertically aligned carbon nanotube (VACNT) cold cathodes for high-resolution electron microscopy applications. VACNT arrays with varying island diameters (small, medium, and large) and shapes (hexagonal and square) were fabricated to evaluate their impact on electron field emission. The effect of increasing emitter density within a fixed area was also analyzed. Smaller island diameters produced stronger localized electric fields, enhancing current density, while hexagonal shapes provided better beam focusing with reduced divergence. Increased emitter density improved total current output and emission stability. Optimized electron beam emission currents of 650 and 120 μA were achieved for diode and triode structures, respectively, using a hexagonal design with 19 emitters and a 23 μm diameter. The optimized emitters demonstrated exceptional performance, with a high current density of 1.2 × 106 A/m2 and a beam brightness of 1.8 × 108 A/m2 sr V. Additionally, the emitters exhibited a minimal beam divergence angle of 1.02°, ensuring precision and focus on electron beam applications. These results highlight the potential of the developed electron beam system for advanced applications requiring high-intensity, stable, and precise electron sources. These findings underscore the importance of optimizing geometric parameters to enhance electron beam performance, advancing VACNT-based electron sources for microscopy and other precision technologies.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (12) , 7060-7065
Physical Interpretation of Field Emission Behavior in Patterned Samples via Simulation-Validated Models
Vertically aligned carbon nanotube (VACNT) arrays have been developed to enhance field emission (FE) performance. In this study, the CNT tips were arranged in a $17\times 17$ square array, and various patterns were selectively introduced by removing the tips to mitigate the screening effect and improve the emission characteristics. FE experiments were conducted for each pattern and the corresponding simulations were performed and compared. To quantitatively evaluate the performance of each pattern, eight analytical models were introduced. Among these, the minimum $E$ field (Min E) model predicted excellent agreement with the top three patterns in the experimental results, indicating potentially predictive tools for future emitter design.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (12) , 7060-7065
Physical Interpretation of Field Emission Behavior in Patterned Samples via Simulation-Validated Models
Vertically aligned carbon nanotube (VACNT) arrays have been developed to enhance field emission (FE) performance. In this study, the CNT tips were arranged in a $17\times 17$ square array, and various patterns were selectively introduced by removing the tips to mitigate the screening effect and improve the emission characteristics. FE experiments were conducted for each pattern and the corresponding simulations were performed and compared. To quantitatively evaluate the performance of each pattern, eight analytical models were introduced. Among these, the minimum $E$ field (Min E) model predicted excellent agreement with the top three patterns in the experimental results, indicating potentially predictive tools for future emitter design.
- 1 March 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 43 (2)
Focusing electrode effect on the EUV lighting technology based on C-beam irradiation technique
One of the key issues in large-scale semiconductor manufacturing is EUV (extreme ultraviolet) lighting source technology [N. Fu, Y. Liu, X. Ma, and Z. Chen, J. Microelectron. Manuf. 2, 1 (2019); I. Fomenkov et al., Adv. Opt. Technol. 6, 173 (2017); J. Beckers, T. van de Ven, R. van der Horst, D. Astakhov, and V. Banine, Appl. Sci. 9, 2827 (2019); V. Y. Banine, K. N. Koshelev, and G. Swinkels, J. Phys. D: Appl. Phys.J. Phys. D. Appl. Phys. 44, 253001 (2011)]. We have previously demonstrated the use of a cold cathode electron beam (C-beam) for the EUV lighting source [S. T. Yoo and K. C. Park, Nanomaterials 12, 4134 (2022); S. T. Yoo and K. C. Park, Jpn. J. Appl. Phys. 62, SG1002 (2023); B. C. Adhikari, S. T. Yoo, and K. C. Park, in 2023 7th IEEE Electron Devices Technology and Manufacturing Conference, Seoul, South Korea, 7 -10 March 2023 (IEEE, New York, 2023), pp. 1–3]. However, advancing the next generation of EUV lighting with C-beam irradiation requires improvements in beam spot size, EUV efficiency, and lighting power, as identified in our earlier studies. To address these issues, we implemented a focusing electrode technique [B. C. Adhikari, B. Ketan, R. Patil, E. H. Choi, and K. C. Park, Sci. Rep. 13, 15630 (2023)]. This approach improves the beam’s spot size and brightness without reducing the anode current. By measuring transmittance under different anode and focusing bias conditions, we identified the optimal focusing electrode bias that avoids electron reflection between the focusing electrode and the beam. As a result, we achieved a 4.8 times reduction in beam divergence angle and a 34% increase in brightness, measured by gray value on a phosphor screen, without any loss of anode current. Additionally, by increasing the anode current density with a focusing electrode, we observed a 23.7% improvement in EUV photocurrent as measured with a photodiode equipped with a Zr filter (300 nm) [F. R. Powell and T. A. Johnson, in Emerging Lithographic Technologies V, Santa Clara, California USA, 25 February-2 March 2001 (SPIE, Bellingham, 2001), pp. 585–589; N. I. Chkhalo et al., in International Conference on Micro- and Nano-Electronics 2009, Zvenigorod, Russia, 5-9 October 2009 (IEEE, New York, 2010), pp. 49–57]. These findings highlight the potential of developing an EUV inspection tool based on the C-beam irradiation technique by integrating the focusing electrode.
- 1 March 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 43 (2)
Focusing electrode effect on the EUV lighting technology based on C-beam irradiation technique
One of the key issues in large-scale semiconductor manufacturing is EUV (extreme ultraviolet) lighting source technology [N. Fu, Y. Liu, X. Ma, and Z. Chen, J. Microelectron. Manuf. 2, 1 (2019); I. Fomenkov et al., Adv. Opt. Technol. 6, 173 (2017); J. Beckers, T. van de Ven, R. van der Horst, D. Astakhov, and V. Banine, Appl. Sci. 9, 2827 (2019); V. Y. Banine, K. N. Koshelev, and G. Swinkels, J. Phys. D: Appl. Phys.J. Phys. D. Appl. Phys. 44, 253001 (2011)]. We have previously demonstrated the use of a cold cathode electron beam (C-beam) for the EUV lighting source [S. T. Yoo and K. C. Park, Nanomaterials 12, 4134 (2022); S. T. Yoo and K. C. Park, Jpn. J. Appl. Phys. 62, SG1002 (2023); B. C. Adhikari, S. T. Yoo, and K. C. Park, in 2023 7th IEEE Electron Devices Technology and Manufacturing Conference, Seoul, South Korea, 7 -10 March 2023 (IEEE, New York, 2023), pp. 1–3]. However, advancing the next generation of EUV lighting with C-beam irradiation requires improvements in beam spot size, EUV efficiency, and lighting power, as identified in our earlier studies. To address these issues, we implemented a focusing electrode technique [B. C. Adhikari, B. Ketan, R. Patil, E. H. Choi, and K. C. Park, Sci. Rep. 13, 15630 (2023)]. This approach improves the beam’s spot size and brightness without reducing the anode current. By measuring transmittance under different anode and focusing bias conditions, we identified the optimal focusing electrode bias that avoids electron reflection between the focusing electrode and the beam. As a result, we achieved a 4.8 times reduction in beam divergence angle and a 34% increase in brightness, measured by gray value on a phosphor screen, without any loss of anode current. Additionally, by increasing the anode current density with a focusing electrode, we observed a 23.7% improvement in EUV photocurrent as measured with a photodiode equipped with a Zr filter (300 nm) [F. R. Powell and T. A. Johnson, in Emerging Lithographic Technologies V, Santa Clara, California USA, 25 February-2 March 2001 (SPIE, Bellingham, 2001), pp. 585–589; N. I. Chkhalo et al., in International Conference on Micro- and Nano-Electronics 2009, Zvenigorod, Russia, 5-9 October 2009 (IEEE, New York, 2010), pp. 49–57]. These findings highlight the potential of developing an EUV inspection tool based on the C-beam irradiation technique by integrating the focusing electrode.
- Open Access
- 2 April 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (3)
Effect of beam and gate offset size on x-ray focal spot resolution of a cold cathode electron beam
In x-ray imaging, high resolution is essential, particularly in sectors such as medical and industries where the need for nondestructive defect detection is required. Previous research has shown that altering beam design and the number of gates offset holes has an impact on focal spot size (FSS). However, the specific effects of beam size and offset size were not thoroughly assessed. In the present study, the influence of beam size and gate offset size was evaluated by utilizing a cold cathode electron beam. Various beam sizes were employed to achieve a small FSS, and subsequently, the smallest beam was utilized to examine the impact of gate offset size. In doing so, the smallest FSS of 0.25 mm vertical and 0.33 mm horizontal was attained without the utilization of any additional focusing lens. This illustrates that by adjusting the beam size and gate offset size, it is possible to attain a small FSS, facilitating the development of an economically viable x-ray imaging beam.
- 2 April 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (3)
Open AccessEffect of beam and gate offset size on x-ray focal spot resolution of a cold cathode electron beam
In x-ray imaging, high resolution is essential, particularly in sectors such as medical and industries where the need for nondestructive defect detection is required. Previous research has shown that altering beam design and the number of gates offset holes has an impact on focal spot size (FSS). However, the specific effects of beam size and offset size were not thoroughly assessed. In the present study, the influence of beam size and gate offset size was evaluated by utilizing a cold cathode electron beam. Various beam sizes were employed to achieve a small FSS, and subsequently, the smallest beam was utilized to examine the impact of gate offset size. In doing so, the smallest FSS of 0.25 mm vertical and 0.33 mm horizontal was attained without the utilization of any additional focusing lens. This illustrates that by adjusting the beam size and gate offset size, it is possible to attain a small FSS, facilitating the development of an economically viable x-ray imaging beam.
- Open Access
- 16 February 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (2)
Impact of electrical aging on x-ray image quality and dose rate with vertically aligned carbon nanotube based cold cathode electron beam (C-beam)
The adoption of vertically aligned carbon nanotubes (VACNTs) as electron emitters in x-ray generation has opened a new path for medical imaging technology advancement. With their outstanding electron emission capabilities, VACNTs provide a distinct advantage in miniaturizing and improving the performance of x-ray devices. This research focuses on the effect of electrical aging on x-ray imaging quality and the dose rate while using VACNTs as the electron source. The study includes a thorough examination of the electrical aging effects on VACNT-based x-ray systems, with an emphasis on changes in emission characteristics, beam stability, and the resulting variations in x-ray output. Experiment results show that electrical aging has a considerable impact on the performance of VACNT-based x-ray sources, with visible changes in electron emission parameters and subsequent consequences on x-ray imaging quality. Furthermore, the study investigates the relationship between electrical aging and the x-ray dose rate, providing vital insights into radiation exposure optimization in medical diagnostics.
- 16 February 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (2)
Open AccessImpact of electrical aging on x-ray image quality and dose rate with vertically aligned carbon nanotube based cold cathode electron beam (C-beam)
The adoption of vertically aligned carbon nanotubes (VACNTs) as electron emitters in x-ray generation has opened a new path for medical imaging technology advancement. With their outstanding electron emission capabilities, VACNTs provide a distinct advantage in miniaturizing and improving the performance of x-ray devices. This research focuses on the effect of electrical aging on x-ray imaging quality and the dose rate while using VACNTs as the electron source. The study includes a thorough examination of the electrical aging effects on VACNT-based x-ray systems, with an emphasis on changes in emission characteristics, beam stability, and the resulting variations in x-ray output. Experiment results show that electrical aging has a considerable impact on the performance of VACNT-based x-ray sources, with visible changes in electron emission parameters and subsequent consequences on x-ray imaging quality. Furthermore, the study investigates the relationship between electrical aging and the x-ray dose rate, providing vital insights into radiation exposure optimization in medical diagnostics.
- Open Access
- 20 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Optimization of vertically aligned carbon nanotube beam trajectory with the help of focusing electrode in the microchannel plate
The focusing electrode plays an important role to reduce the electron beam trajectory with low dispersion and high brightness. This article summarizes the importance of the vertically aligned multi-walled carbon nanotube effect with the focusing electrode. First of all, the effect of electron beam trajectory is studied with the different heights, hole sizes, and applied voltage of the focusing electrode by the opera 3D simulation. The field emission electron beam spot is captured in the microchannel plate which helps to reduce the signal noise effect and damage of CNT tips by the joule heating effect. The high-dense bright spot is optimized at the focusing electrode hole size of 2 mm, and the height of 1 mm from the gate mesh electrode at the low bias voltage of − 200 V without the loss of current. The FWHM of the electron beam is calculated 0.9 mm with its opening angle of 0.9° which could be applicable in high-resolution multi-electron beam microscopy and nano-focused X-ray system technology.
- 20 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Open AccessOptimization of vertically aligned carbon nanotube beam trajectory with the help of focusing electrode in the microchannel plate
The focusing electrode plays an important role to reduce the electron beam trajectory with low dispersion and high brightness. This article summarizes the importance of the vertically aligned multi-walled carbon nanotube effect with the focusing electrode. First of all, the effect of electron beam trajectory is studied with the different heights, hole sizes, and applied voltage of the focusing electrode by the opera 3D simulation. The field emission electron beam spot is captured in the microchannel plate which helps to reduce the signal noise effect and damage of CNT tips by the joule heating effect. The high-dense bright spot is optimized at the focusing electrode hole size of 2 mm, and the height of 1 mm from the gate mesh electrode at the low bias voltage of − 200 V without the loss of current. The FWHM of the electron beam is calculated 0.9 mm with its opening angle of 0.9° which could be applicable in high-resolution multi-electron beam microscopy and nano-focused X-ray system technology.