Francesc Xavier Muñoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesc Xavier Muñoz has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Francisco Javier del Campo
BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
3 shared publications - Jordi Mas
Department of Genetics and Microbiology, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain
3 shared publications - Eva Baldrich
Diagnostic Nanotools Group, Vall d'Hebron Institute of Research (VHIR), Instituto de Investigación Sanitaria Hospital Universitari Vall d'Hebron (IIS IR-HUVH), 08035 Barcelona, Spain
2 shared publications François G. Chevallier
Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, UK, Fax: (+44) 01865-27541
2 shared publications- Richard G. Compton
Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, United Kingdom
2 shared publications - Roser Mas
Centro National de Microelectrónica, IMB-CNM, CSIC, Campus de la Universidad Autónoma de Barcelona, Bellaterra 08193, Spain
2 shared publications
Latest Publications
- Open Access
- 13 February 2026
- Published by Elsevier in SSRN Electronic Journal
Silk–Ionic Liquid Lactate Biosensor with a Diffusion Layer for Wide-Range and High-Sensitivity Sweat Analysis
This study presents a hybrid electrochemical biosensor for lactate detection in human sweat, integrating silk fibroin as a bioactive immobilization matrix, ionic liquids (IL) as ionic conductivity enhancers, and a Prussian Blue-based transducer. Silk fibroin significantly enhanced lactate oxidase stability and catalytic activity, while the incorporation of IL improved ionic transport, thereby favoring electron transfer and increasing sensor sensitivity. To overcome the intrinsically narrow linear range of enzymatic lactate sensors, a diffusion-modulating top layer was engineered, enabling controlled mass transport and extending the measurable range to the full physiological lactate window in sweat (0.5-70 mM). The resulting biosensor exhibited high sensitivity, robust linearity, and stable performance. Validation with artificial and real sweat samples demonstrated accurate quantification and >90% recovery, with strong agreement with ion chromatography. This diffusion-layer-enhanced silk/ionic liquid platform offers a novel materials-engineered approach for high-performance, real-time, and non-invasive lactate sensing in wearable and health-monitoring applications.
- 13 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSilk–Ionic Liquid Lactate Biosensor with a Diffusion Layer for Wide-Range and High-Sensitivity Sweat Analysis
This study presents a hybrid electrochemical biosensor for lactate detection in human sweat, integrating silk fibroin as a bioactive immobilization matrix, ionic liquids (IL) as ionic conductivity enhancers, and a Prussian Blue-based transducer. Silk fibroin significantly enhanced lactate oxidase stability and catalytic activity, while the incorporation of IL improved ionic transport, thereby favoring electron transfer and increasing sensor sensitivity. To overcome the intrinsically narrow linear range of enzymatic lactate sensors, a diffusion-modulating top layer was engineered, enabling controlled mass transport and extending the measurable range to the full physiological lactate window in sweat (0.5-70 mM). The resulting biosensor exhibited high sensitivity, robust linearity, and stable performance. Validation with artificial and real sweat samples demonstrated accurate quantification and >90% recovery, with strong agreement with ion chromatography. This diffusion-layer-enhanced silk/ionic liquid platform offers a novel materials-engineered approach for high-performance, real-time, and non-invasive lactate sensing in wearable and health-monitoring applications.
- 1 July 2012
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 66, 27-37
Design of a microfluidic respirometer for semi-continuous amperometric short time biochemical oxygen demand (BODst) analysis
- 1 July 2012
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 66, 27-37
Design of a microfluidic respirometer for semi-continuous amperometric short time biochemical oxygen demand (BODst) analysis
- 1 December 2008
- Published by Elsevier in Analytical Biochemistry
- Vol. 383 (1) , 68-75
Sensing bacteria but treating them well: Determination of optimal incubation and storage conditions
- 1 December 2008
- Published by Elsevier in Analytical Biochemistry
- Vol. 383 (1) , 68-75
Sensing bacteria but treating them well: Determination of optimal incubation and storage conditions
- 30 June 2008
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 33 (11) , 2729-2737
Microchip power compensated calorimetry applied to metal hydride characterization
- 30 June 2008
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 33 (11) , 2729-2737
Microchip power compensated calorimetry applied to metal hydride characterization
- 10 June 2008
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 133 (8) , 1009-1012
Enzyme shadowing: using antibody–enzyme dually-labeled magnetic particles for fast bacterial detection
Using magnetic particles and immunoseparation for target recovery and detection has been reported to improve the performance and detection limits of traditional analytical methods. For example, magnetic immunocapture can be coupled to detection in a sandwich format using an antibody (Ab) labeled with a reporter molecule or enzyme. In this work we demonstrate that simultaneous incorporation of capture and reporter biocomponents onto the sensing surface is possible and provides assays that are extremely fast and easy to carry out. As a proof of concept, we have produced dually-labeled magnetic particles, simultaneously functionalized with antibody and reporter enzyme. Subsequent capture of Escherichia coli generates a shadowing effect on the particle surface and interferes with the activity of a number of enzyme units. The decrease in signal recorded is proportional to the bacterial concentration and is specific for the target microorganism, with a detection limit of 103–104cell mL−1 in an assay of about one hour.
- 10 June 2008
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 133 (8) , 1009-1012
Enzyme shadowing: using antibody–enzyme dually-labeled magnetic particles for fast bacterial detection
Using magnetic particles and immunoseparation for target recovery and detection has been reported to improve the performance and detection limits of traditional analytical methods. For example, magnetic immunocapture can be coupled to detection in a sandwich format using an antibody (Ab) labeled with a reporter molecule or enzyme. In this work we demonstrate that simultaneous incorporation of capture and reporter biocomponents onto the sensing surface is possible and provides assays that are extremely fast and easy to carry out. As a proof of concept, we have produced dually-labeled magnetic particles, simultaneously functionalized with antibody and reporter enzyme. Subsequent capture of Escherichia coli generates a shadowing effect on the particle surface and interferes with the activity of a number of enzyme units. The decrease in signal recorded is proportional to the bacterial concentration and is specific for the target microorganism, with a detection limit of 103–104cell mL−1 in an assay of about one hour.
- 31 August 2007
- Published by Elsevier in Microelectronic Engineering
- Vol. 84 (5-8) , 1775-1778
Second order effects of aspect ratio variations in high sensitivity grating couplers
- 31 August 2007
- Published by Elsevier in Microelectronic Engineering
- Vol. 84 (5-8) , 1775-1778
Second order effects of aspect ratio variations in high sensitivity grating couplers
- 7 November 2006
- Published by Wiley in Chemphyschem
- Vol. 7 (12) , 2585-2592
A New Method for the Study of Processes at the Liquid-Liquid Interface Using an Array of Microdroplets on a Au Electrode
- 7 November 2006
- Published by Wiley in Chemphyschem
- Vol. 7 (12) , 2585-2592
A New Method for the Study of Processes at the Liquid-Liquid Interface Using an Array of Microdroplets on a Au Electrode