Yuan Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuan Gao has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Tayeb Ghasr
Department of Electrical and Computer engineering (ECpE), Iowa State University, Ames, IA, USA
4 shared publications - Reza Zoughi
Electrical and Computer Engineering Department, Center for Nondestructive Evaluation, Iowa State University, Ames, IA, USA
4 shared publications Reza Zoughi
Applied Microwave Nondestructive Testing Laboratory (amntl), Electrical and Computer Engineering Department, Missouri University of Science and Technology, Rolla, MO, USA
3 shared publications- Baolong Wu
School of Electronics and Information, Northwestern Polytechnical University, Xi’an 710072, China
1 shared publication - Mahboobeh Mahmoodi
Power and Signal Integrity Group, Qualcomm Technologies Inc., San Diego, CA, USA
1 shared publication - Michael Nacy
Applied Microwave Nondestructive Testing Laboratory, Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, MO 65409 USA
1 shared publication
Latest Publications
- Open Access
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 1, 1-9
Design of a Novel Frequency-Coded Chipless RFID Tag
Chipless radio frequency identification (RFID) is a low-cost RFID solution that has the potential to replace traditional barcodes in short-range applications. In this paper, a novel frequency-coded chipless RFID tag is designed at Ku-band (12.4-18 GHz). Compared to previous designs, the proposed tag has a more compact design by multiplexing one tag antenna for both transmitting and receiving purposes. In addition, the tag is designed on a substrate with ground plane, which reduces the undesired effect of the background detuning. To demonstrate the performance of the proposed chipless RFID tag, four 3-bit tags are designed in simulation, with having two of them manufactured and tested. Simulations and measurements are performed for codes of 000 and 111, and the results verify the validity of the proposed design. Finally, the sensitivity of the tag response to fabrication errors and orientation are discussed and demonstrated with simulations.
- 17 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 1, 1-9
Open AccessDesign of a Novel Frequency-Coded Chipless RFID Tag
Chipless radio frequency identification (RFID) is a low-cost RFID solution that has the potential to replace traditional barcodes in short-range applications. In this paper, a novel frequency-coded chipless RFID tag is designed at Ku-band (12.4-18 GHz). Compared to previous designs, the proposed tag has a more compact design by multiplexing one tag antenna for both transmitting and receiving purposes. In addition, the tag is designed on a substrate with ground plane, which reduces the undesired effect of the background detuning. To demonstrate the performance of the proposed chipless RFID tag, four 3-bit tags are designed in simulation, with having two of them manufactured and tested. Simulations and measurements are performed for codes of 000 and 111, and the results verify the validity of the proposed design. Finally, the sensitivity of the tag response to fabrication errors and orientation are discussed and demonstrated with simulations.
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (7) , 4919-4929
Complex Permittivity Extraction From Synthetic Aperture Radar Images
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (7) , 4919-4929
Complex Permittivity Extraction From Synthetic Aperture Radar Images
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (2) , 512-524
Towards Accurate and Wideband In Vivo Measurement of Skin Dielectric Properties
In this paper, we first review the most common measurement methods, previously used, for assessing the complex permittivity of human skin, namely, open-ended coaxial and waveguide probe reflectometry methods. We then outline and emphasize their useful features and shortcomings that can adversely affect the measurements. Then, an approach utilizing an open-ended waveguide probe with an engineered ground plane and a thin dielectric layer in front of the aperture to prevent skin protrusion is proposed. This approach utilizes a full-wave electromagnetic model that accurately describes the interaction of a layered skin with this probe. Furthermore, comprehensive analyses were performed to investigate the important sources of modeling and measurement errors and their influences on the calculated skin complex permittivity. The results of these analyses have shown that the proposed method can achieve $~ $85% and $~ $95% calculation accuracy for skin relative (to free space) dielectric constant and relative dielectric loss factor, respectively. Finally, a series of in vivo measurement was performed in the Ka-band (26.5-40 GHz) on several different locations of three human subjects using this proposed method. In addition, it is demonstrated that the homogeneous skin model cannot be used for areas of the body where the stratum corneum (SC) layer is relatively thick (e.g., palm). Finally, the effect of a thick SC layer on the relative complex permittivity calculation was discussed, and a modified method to determine the relative complex permittivity of the layered skin was proposed and verified by simulations.
- 16 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (2) , 512-524
Towards Accurate and Wideband In Vivo Measurement of Skin Dielectric Properties
In this paper, we first review the most common measurement methods, previously used, for assessing the complex permittivity of human skin, namely, open-ended coaxial and waveguide probe reflectometry methods. We then outline and emphasize their useful features and shortcomings that can adversely affect the measurements. Then, an approach utilizing an open-ended waveguide probe with an engineered ground plane and a thin dielectric layer in front of the aperture to prevent skin protrusion is proposed. This approach utilizes a full-wave electromagnetic model that accurately describes the interaction of a layered skin with this probe. Furthermore, comprehensive analyses were performed to investigate the important sources of modeling and measurement errors and their influences on the calculated skin complex permittivity. The results of these analyses have shown that the proposed method can achieve $~ $85% and $~ $95% calculation accuracy for skin relative (to free space) dielectric constant and relative dielectric loss factor, respectively. Finally, a series of in vivo measurement was performed in the Ka-band (26.5-40 GHz) on several different locations of three human subjects using this proposed method. In addition, it is demonstrated that the homogeneous skin model cannot be used for areas of the body where the stratum corneum (SC) layer is relatively thick (e.g., palm). Finally, the effect of a thick SC layer on the relative complex permittivity calculation was discussed, and a modified method to determine the relative complex permittivity of the layered skin was proposed and verified by simulations.
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (12) , 2804-2811
Resolution-Based Analysis for Optimizing Subaperture Measurements in Circular SAR Imaging
Circular geometries are often encountered in nondestructive testing and evaluation applications. Circular synthetic aperture radar imaging technique, capable of producing high-resolution images, has great utility for this purpose. However, in many such applications, scanning only a portion of the circular geometry (i.e., scanning domain), called the subaperture, may only be possible or sufficient for a particular inspection need. Consequently, in subaperture imaging, for an imaging aspect angle and aspect angle measurement interval, we must determine the expected image resolution. In this paper, for an arbitrary area of interest, we analyze the image spatial resolution obtained from a generally defined aspect angle and aspect angle measurement interval. Using resolution as the criteria, we use this method to determine the boundary between small and large subapertures, which also show to produce markedly different range and cross-range resolutions as a function of aspect angle and aspect angle measurement interval. Moreover, the optimum aspect angle and aspect angle measurement interval for this fixed area of interest are defined based on these analyses. Finally, the results of these analyses and images obtained from simulations are compared and corroborated with relevant experimental results at X-band (8.2-12.4 GHz).
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (12) , 2804-2811
Resolution-Based Analysis for Optimizing Subaperture Measurements in Circular SAR Imaging
Circular geometries are often encountered in nondestructive testing and evaluation applications. Circular synthetic aperture radar imaging technique, capable of producing high-resolution images, has great utility for this purpose. However, in many such applications, scanning only a portion of the circular geometry (i.e., scanning domain), called the subaperture, may only be possible or sufficient for a particular inspection need. Consequently, in subaperture imaging, for an imaging aspect angle and aspect angle measurement interval, we must determine the expected image resolution. In this paper, for an arbitrary area of interest, we analyze the image spatial resolution obtained from a generally defined aspect angle and aspect angle measurement interval. Using resolution as the criteria, we use this method to determine the boundary between small and large subapertures, which also show to produce markedly different range and cross-range resolutions as a function of aspect angle and aspect angle measurement interval. Moreover, the optimum aspect angle and aspect angle measurement interval for this fixed area of interest are defined based on these analyses. Finally, the results of these analyses and images obtained from simulations are compared and corroborated with relevant experimental results at X-band (8.2-12.4 GHz).
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Effects of translational position error on microwave synthetic aperture radar (SAR) imaging systems
Translational position error in imaging systems can cause significant imaging quality degradation or image distortion. In this study, effects of translational position error in microwave SAR imaging system is investigated and evaluated by defining three image quality metrics. Extensive simulations are performed, in X-Band (8.2-12.4 GHz), to show the relationship between image quality and translational position error. Simulation results show that the imaging quality degrades with increasing position errors, and the sensitivity to translational position error increases as the standoff distance decreases. Measurements are also performed in X-Band for a 1D SAR imaging system. The measured results show good agreement with the simulated results. The methodology proposed in this study could be used to evaluate the feasibility or help define the required specifications of a microwave SAR imaging system for a specific application.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Effects of translational position error on microwave synthetic aperture radar (SAR) imaging systems
Translational position error in imaging systems can cause significant imaging quality degradation or image distortion. In this study, effects of translational position error in microwave SAR imaging system is investigated and evaluated by defining three image quality metrics. Extensive simulations are performed, in X-Band (8.2-12.4 GHz), to show the relationship between image quality and translational position error. Simulation results show that the imaging quality degrades with increasing position errors, and the sensitivity to translational position error increases as the standoff distance decreases. Measurements are also performed in X-Band for a 1D SAR imaging system. The measured results show good agreement with the simulated results. The methodology proposed in this study could be used to evaluate the feasibility or help define the required specifications of a microwave SAR imaging system for a specific application.
- 9 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (1) , 77-84
Millimeter Wave Reflectometry and Imaging for Noninvasive Diagnosis of Skin Burn Injuries
Accurate assessment of the degree of burn in human skin is critically important for burn technicians and physicians when making treatment decisions. Millimeter wave reflectometry and imaging are potential diagnostic tools capable of distinguishing between healthy and burned skin, as the dielectric properties of the latter are significantly different from that of the former. In this paper, the commonly used layered model of human skin is used to simulate the reflection properties of skin with varying degrees of burn, at Ka-band (26.5-40 GHz), to demonstrate the potential for such diagnosis. Measurements of complex reflection coefficient are also conducted on a pigskin with and without medical dressing, which is a close mimic to human skin. Good agreement is obtained, in amplitude and variation trends in the reflection coefficient results, between simulation and measurement results, indicating the potential effectiveness and feasibility of burn degree diagnosis by localized millimeter wave reflectometry and complex reflection coefficient $L^{{\mathrm {2}}}$ -Norm analysis. Finally, synthetic aperture radar imaging technique is used to examine the efficacy of imaging for burn wound at V-band (50-75 GHz). In addition, the effectiveness of localized and imaging methods for evaluating burns covered by medical dressings is also demonstrated.- 9 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (1) , 77-84
Millimeter Wave Reflectometry and Imaging for Noninvasive Diagnosis of Skin Burn Injuries
Accurate assessment of the degree of burn in human skin is critically important for burn technicians and physicians when making treatment decisions. Millimeter wave reflectometry and imaging are potential diagnostic tools capable of distinguishing between healthy and burned skin, as the dielectric properties of the latter are significantly different from that of the former. In this paper, the commonly used layered model of human skin is used to simulate the reflection properties of skin with varying degrees of burn, at Ka-band (26.5-40 GHz), to demonstrate the potential for such diagnosis. Measurements of complex reflection coefficient are also conducted on a pigskin with and without medical dressing, which is a close mimic to human skin. Good agreement is obtained, in amplitude and variation trends in the reflection coefficient results, between simulation and measurement results, indicating the potential effectiveness and feasibility of burn degree diagnosis by localized millimeter wave reflectometry and complex reflection coefficient $L^{{\mathrm {2}}}$ -Norm analysis. Finally, synthetic aperture radar imaging technique is used to examine the efficacy of imaging for burn wound at V-band (50-75 GHz). In addition, the effectiveness of localized and imaging methods for evaluating burns covered by medical dressings is also demonstrated.- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Millimeter reflectometry as an effective diagnosis tool for skin burn injuries
Accurate skin degree-of-burn assessment is critically important and can assist burn technicians and physicians to make appropriate treatment decisions. Millimeter wave imaging is a potential diagnosis tool capable of distinguishing between healthy and burned skin as the dielectric properties of the latter is significantly different from that of the former. In this paper, the layered model of human skin is used along with numerical electromagnetic simulations, at V-band (50-75 GHz), to demonstrate the potential for such diagnosis. In addition, an image of a burned pig skin is produced at V-band showing the potential of this methodology at millimeter wave frequencies.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Millimeter reflectometry as an effective diagnosis tool for skin burn injuries
Accurate skin degree-of-burn assessment is critically important and can assist burn technicians and physicians to make appropriate treatment decisions. Millimeter wave imaging is a potential diagnosis tool capable of distinguishing between healthy and burned skin as the dielectric properties of the latter is significantly different from that of the former. In this paper, the layered model of human skin is used along with numerical electromagnetic simulations, at V-band (50-75 GHz), to demonstrate the potential for such diagnosis. In addition, an image of a burned pig skin is produced at V-band showing the potential of this methodology at millimeter wave frequencies.