Kepa Balparda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kepa Balparda has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Tatiana Herrera-Chalarca
Department of Clinical Research and Legal Affairs, Black Mammoth Surgical, Medellín, Colombia
12 shared publications- Laura Andrea Silva-Quintero
Departamento de Oftalmología
6 shared publications - Tatiana Herrera-Chalarca
Department of Clinical Research, Black Mammoth Surgical, Medellín, Colombia
5 shared publications - Ana María Diaz-Zuluaga
University of California Los Angeles
4 shared publications Mariana Escobar-Giraldo
Univ Pontificia Bolivariana, Dept Ophthalmol, Medellin, Colombia
4 shared publications- Claudia Marcela Vanegas-Ramírez
Department of Ophthalmology, Universidad Pontificia Bolivariana, Medellín, Colombia
3 shared publications
Latest Publications
- Open Access
- 28 July 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (8) , 1108-1115
Keratopigmentation in the modern era: A review of current techniques, results, and safety
To conduct a literature review on current knowledge regarding keratopigmentation (KTP), with a particular focus on femtosecond-assisted procedures. A narrative literature review was performed. Academic databases (PubMed, Google Scholar, Cochrane Library, and SciELO) were searched for articles containing the keywords “keratopigmentation” and “corneal tattoo.” All relevant articles were reviewed, and appropriate ones related to the topic were included in the review. KTP has a variety of indications, including enhancing the aesthetic profile of blind eyes with decompensated corneas and alleviating symptoms related to iris atrophy. The trend of strictly cosmetic KTP has recently gained popularity among several surgeons worldwide. Despite some controversy, most articles reported excellent outcomes associated with KTP, alongside a high safety profile. Histopathological studies have demonstrated that modern micronized pigments are entirely biocompatible. Femtosecond laser-assisted KTP appears to be a safe and effective procedure. However, more long-term studies are necessary to enhance our understanding of the risks associated with strictly cosmetic applications of this technique.
- 28 July 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (8) , 1108-1115
Open AccessKeratopigmentation in the modern era: A review of current techniques, results, and safety
To conduct a literature review on current knowledge regarding keratopigmentation (KTP), with a particular focus on femtosecond-assisted procedures. A narrative literature review was performed. Academic databases (PubMed, Google Scholar, Cochrane Library, and SciELO) were searched for articles containing the keywords “keratopigmentation” and “corneal tattoo.” All relevant articles were reviewed, and appropriate ones related to the topic were included in the review. KTP has a variety of indications, including enhancing the aesthetic profile of blind eyes with decompensated corneas and alleviating symptoms related to iris atrophy. The trend of strictly cosmetic KTP has recently gained popularity among several surgeons worldwide. Despite some controversy, most articles reported excellent outcomes associated with KTP, alongside a high safety profile. Histopathological studies have demonstrated that modern micronized pigments are entirely biocompatible. Femtosecond laser-assisted KTP appears to be a safe and effective procedure. However, more long-term studies are necessary to enhance our understanding of the risks associated with strictly cosmetic applications of this technique.
- 18 February 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (2) , 160-167
Multivariate Determinants of Emotional Compromise and Subjective Functional Quality of Life in Surgery-Naïve Patients With Keratoconus as Measured With the Keratoconus End Points Assessment Questionnaire
Purpose: Keratoconus affects patients' quality of life. No study has assessed the multivariate determinants of quality of life using the keratoconus end points assessment questionnaire (KEPAQ). Methods: This study included patients with keratoconus with no history of ocular surgery, who underwent clinical evaluation and tomographic imaging using a dual Scheimpflug/Placido device (Galilei G6). Emotional and functional quality of life was assessed using the KEPAQ. Multiple linear regression models were constructed for each KEPAQ subscale to adjust for confounding variables. Results: A total of 140 surgery-naïve patients with keratoconus were included, with a median age of 39 years and a male predominance (57.1%). For the KEPAQ-E subscale, the multivariate model was significant [F(84,10) = 2.79; adjusted R 2 = 0.160, P = 0.005], showing that female sex (β = −0.41) and worse corrected distance visual acuity in the better-seeing eye (β = −0.29) were associated with lower quality of life. Including the functional subscale score significantly enhanced the model's performance (adjusted R 2 = 0.464, β = 0.60). For the KEPAQ-F subscale, the model was also significant [F(84,10) = 2.37; adjusted R 2 = 0.127, P = 0.016], with corneal astigmatism in the better-seeing eye (β = −0.30) reducing quality of life. Adding the emotional subscale score improved the model (adjusted R 2 = 0.442, β = 0.62). Conclusions: Female sex, reduced vision, and corneal astigmatism negatively affect quality of life in patients with keratoconus. Nonetheless, patients' perceived impairment as measured in 1 subscale is a stronger predictor of overall quality of life than clinical and tomographic factors alone.
- 18 February 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (2) , 160-167
Multivariate Determinants of Emotional Compromise and Subjective Functional Quality of Life in Surgery-Naïve Patients With Keratoconus as Measured With the Keratoconus End Points Assessment Questionnaire
Purpose: Keratoconus affects patients' quality of life. No study has assessed the multivariate determinants of quality of life using the keratoconus end points assessment questionnaire (KEPAQ). Methods: This study included patients with keratoconus with no history of ocular surgery, who underwent clinical evaluation and tomographic imaging using a dual Scheimpflug/Placido device (Galilei G6). Emotional and functional quality of life was assessed using the KEPAQ. Multiple linear regression models were constructed for each KEPAQ subscale to adjust for confounding variables. Results: A total of 140 surgery-naïve patients with keratoconus were included, with a median age of 39 years and a male predominance (57.1%). For the KEPAQ-E subscale, the multivariate model was significant [F(84,10) = 2.79; adjusted R 2 = 0.160, P = 0.005], showing that female sex (β = −0.41) and worse corrected distance visual acuity in the better-seeing eye (β = −0.29) were associated with lower quality of life. Including the functional subscale score significantly enhanced the model's performance (adjusted R 2 = 0.464, β = 0.60). For the KEPAQ-F subscale, the model was also significant [F(84,10) = 2.37; adjusted R 2 = 0.127, P = 0.016], with corneal astigmatism in the better-seeing eye (β = −0.30) reducing quality of life. Adding the emotional subscale score improved the model (adjusted R 2 = 0.442, β = 0.62). Conclusions: Female sex, reduced vision, and corneal astigmatism negatively affect quality of life in patients with keratoconus. Nonetheless, patients' perceived impairment as measured in 1 subscale is a stronger predictor of overall quality of life than clinical and tomographic factors alone.
- Open Access
- 23 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13, e00142
PRK plus crosslinking to correct refractive error after phakic intraocular lens repeated rotation: Bioptics Xtra
Introduction: Phakic intraocular lens (IOL) surgery is generally considered safe; however, spontaneous IOL rotation can occur in some patients. Repeat spontaneous rotation of the IOL presents a significant challenge that requires careful management. Patient and Clinical Findings: A 30-year-old man underwent bilateral phakic IOL implantation for high myopia in the context of a borderline cornea, characterized by keratometric asymmetry and anterior elevation at the location of the thinnest corneal point. The IOLs experienced spontaneous rotation, which was initially managed by surgical repositioning. However, the IOLs rotated spontaneously again less than a week after the repositioning. Diagnosis, Intervention, and Outcomes: The patient underwent topography-guided photorefractive keratectomy (PRK) combined with accelerated crosslinking (30 mW/cm2 for 90 seconds, totaling 2.7 J/cm2) in both eyes. 6-month post-PRK Xtra, his uncorrected vision improved to 20/20 in the right eye and 20/25 in the left eye. The IOLs have remained stable in their final rotated positions. Conclusions: This is the first reported case, to the authors' knowledge, of using PRK Xtra to manage residual refractive error in a patient experiencing repeated spontaneous rotation of phakic IOLs. This technique is feasible and may serve as an alternative to IOL exchange. It has been named “Bioptics Xtra.”
- 23 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13, e00142
Open AccessPRK plus crosslinking to correct refractive error after phakic intraocular lens repeated rotation: Bioptics Xtra
Introduction: Phakic intraocular lens (IOL) surgery is generally considered safe; however, spontaneous IOL rotation can occur in some patients. Repeat spontaneous rotation of the IOL presents a significant challenge that requires careful management. Patient and Clinical Findings: A 30-year-old man underwent bilateral phakic IOL implantation for high myopia in the context of a borderline cornea, characterized by keratometric asymmetry and anterior elevation at the location of the thinnest corneal point. The IOLs experienced spontaneous rotation, which was initially managed by surgical repositioning. However, the IOLs rotated spontaneously again less than a week after the repositioning. Diagnosis, Intervention, and Outcomes: The patient underwent topography-guided photorefractive keratectomy (PRK) combined with accelerated crosslinking (30 mW/cm2 for 90 seconds, totaling 2.7 J/cm2) in both eyes. 6-month post-PRK Xtra, his uncorrected vision improved to 20/20 in the right eye and 20/25 in the left eye. The IOLs have remained stable in their final rotated positions. Conclusions: This is the first reported case, to the authors' knowledge, of using PRK Xtra to manage residual refractive error in a patient experiencing repeated spontaneous rotation of phakic IOLs. This technique is feasible and may serve as an alternative to IOL exchange. It has been named “Bioptics Xtra.”
- Open Access
- 1 October 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2741-2749
One-Year Results of a Posterior Chamber Toric Phakic Intraocular Lens Implantation in Patients with Keratoconus
Purpose: To determine clinical and refractive results after the implantation of EyeCryl Phakic Toric intraocular lens in patients with stable keratoconus. Methods: The study included all patients diagnosed with keratoconus who underwent implantation of an EyeCryl Phakic Toric intraocular lens (Biotech Healthcare Holding; Ahmedabad, India) in at least one eye and had a follow-up of at least 12 months. Visual and refractive data were collected for all patients, along with corneal tomography measurements using Pentacam, and vault measurement using optical coherence tomography. This retrospective study was conducted at a high-volume private refractive surgery center in Medellín, Colombia. Results: A total of 83 eyes from 47 patients were included in the study. The majority (71.1%) were female, with a mean age of 31.2 ± 5.1 years. After 12 months of follow-up post-surgery, the spherical equivalent improved significantly from – 8.19 ± 4.04 D to – 0.06 ± 0.48 D (p < 0.001). Furthermore, 77% of eyes had a post-surgical spherical equivalent within ± 0.50 D, while 92% had residual astigmatism ≤ 0.50 D. Twelve months after surgery, mean manifest astigmatism was – 0.28 ± 0.27 D. Uncorrected visual acuity also showed improvement, from 1.11 ± 0.35 LogMAR to 0.14 ± 0.11 LogMAR. Moreover, 52.4% of eyes demonstrated an improvement of at least one line in best-corrected visual acuity. Notably, no intraoperative or postoperative complications were observed in the study population. Conclusion: The implantation of EyeCryl Phakic Toric intraocular lenses represents a highly effective and safe option for correcting refractive errors in patients with a history of keratoconus. Refractive accuracy is excellent, and a significant proportion of patients experienced an improvement in their best-corrected vision by at least one line.
- 1 October 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2741-2749
Open AccessOne-Year Results of a Posterior Chamber Toric Phakic Intraocular Lens Implantation in Patients with Keratoconus
Purpose: To determine clinical and refractive results after the implantation of EyeCryl Phakic Toric intraocular lens in patients with stable keratoconus. Methods: The study included all patients diagnosed with keratoconus who underwent implantation of an EyeCryl Phakic Toric intraocular lens (Biotech Healthcare Holding; Ahmedabad, India) in at least one eye and had a follow-up of at least 12 months. Visual and refractive data were collected for all patients, along with corneal tomography measurements using Pentacam, and vault measurement using optical coherence tomography. This retrospective study was conducted at a high-volume private refractive surgery center in Medellín, Colombia. Results: A total of 83 eyes from 47 patients were included in the study. The majority (71.1%) were female, with a mean age of 31.2 ± 5.1 years. After 12 months of follow-up post-surgery, the spherical equivalent improved significantly from – 8.19 ± 4.04 D to – 0.06 ± 0.48 D (p < 0.001). Furthermore, 77% of eyes had a post-surgical spherical equivalent within ± 0.50 D, while 92% had residual astigmatism ≤ 0.50 D. Twelve months after surgery, mean manifest astigmatism was – 0.28 ± 0.27 D. Uncorrected visual acuity also showed improvement, from 1.11 ± 0.35 LogMAR to 0.14 ± 0.11 LogMAR. Moreover, 52.4% of eyes demonstrated an improvement of at least one line in best-corrected visual acuity. Notably, no intraoperative or postoperative complications were observed in the study population. Conclusion: The implantation of EyeCryl Phakic Toric intraocular lenses represents a highly effective and safe option for correcting refractive errors in patients with a history of keratoconus. Refractive accuracy is excellent, and a significant proportion of patients experienced an improvement in their best-corrected vision by at least one line.
- 1 February 2024
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 40 (2) , e89-e97
The Effects of Whole-Corneal and Whole-Eye Higher Order Aberrations on the Discrepancy Between Refractive and Corneal Astigmatism in Otherwise Healthy Candidates for Refractive Surgery
Purpose: To evaluate the effect of different whole-corneal and whole-eye higher order aberrations (HOAs) on levels of axis discrepancy. Methods: This was a retrospective study including healthy candidates for refractive surgery, with one eye being randomly selected. A total of 360 eyes were included. Whole-corneal and whole-eye HOAs were measured twice with a Pentacam AXL Wave (Oculus Optikgeräte GmbH), and subjective manifest refraction was obtained. Axis discrepancy was defined as the absolute difference between Total Corneal Refractive Power flat keratometry axis and manifest refractive axis. Two multiple linear regression models that sought to explore the effect of HOAs in predicting axis discrepancy while adjusting for corneal and refractive confounders were built. Results: Mean age was 29.1 ± 5.8 years and 63.9% of the patients were women. Mean manifest sphere and cylinder were −3.09 ± 2.36 and −1.45 ± 1.37 diopters (D), respectively. Mean cylinder axis discrepancy was 14.4 ± 14.5°. On multiple linear regression, the only variables significantly associated with axis discrepancy were corneal cylinder and corneal lower order aberrations [ F (5,339) = 29.746; P < .001; adjusted R 2 = 0.295]. Lower levels of corneal cylinder are by far the main contributor to astigmatism axis mismatch (ß = −1.164). There was not a single HOA, either corneal or ocular, that significantly loaded into any models. Conclusions: Astigmatism axis mismatch decreases rapidly with increasing levels of corneal astigmatism. Corneal and whole-eye HOAs have no role in astigmatism axis mismatch in healthy candidates for refractive surgery. [ J Refract Surg . 2024;40(2):e89–e97.]
- 1 February 2024
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 40 (2) , e89-e97
The Effects of Whole-Corneal and Whole-Eye Higher Order Aberrations on the Discrepancy Between Refractive and Corneal Astigmatism in Otherwise Healthy Candidates for Refractive Surgery
Purpose: To evaluate the effect of different whole-corneal and whole-eye higher order aberrations (HOAs) on levels of axis discrepancy. Methods: This was a retrospective study including healthy candidates for refractive surgery, with one eye being randomly selected. A total of 360 eyes were included. Whole-corneal and whole-eye HOAs were measured twice with a Pentacam AXL Wave (Oculus Optikgeräte GmbH), and subjective manifest refraction was obtained. Axis discrepancy was defined as the absolute difference between Total Corneal Refractive Power flat keratometry axis and manifest refractive axis. Two multiple linear regression models that sought to explore the effect of HOAs in predicting axis discrepancy while adjusting for corneal and refractive confounders were built. Results: Mean age was 29.1 ± 5.8 years and 63.9% of the patients were women. Mean manifest sphere and cylinder were −3.09 ± 2.36 and −1.45 ± 1.37 diopters (D), respectively. Mean cylinder axis discrepancy was 14.4 ± 14.5°. On multiple linear regression, the only variables significantly associated with axis discrepancy were corneal cylinder and corneal lower order aberrations [ F (5,339) = 29.746; P < .001; adjusted R 2 = 0.295]. Lower levels of corneal cylinder are by far the main contributor to astigmatism axis mismatch (ß = −1.164). There was not a single HOA, either corneal or ocular, that significantly loaded into any models. Conclusions: Astigmatism axis mismatch decreases rapidly with increasing levels of corneal astigmatism. Corneal and whole-eye HOAs have no role in astigmatism axis mismatch in healthy candidates for refractive surgery. [ J Refract Surg . 2024;40(2):e89–e97.]
- Open Access
- 12 December 2023
- Published by Instituto Mexicano del Seguro Social in Revista de la Sociedad Colombiana de Oftalmología
- Vol. 56 (3)
Implante de lente trifocal en piggyback para brindar trifocalidad en paciente con cirugía previa
CLÍNICO Resumen Ante la disponibilidad de plataformas de lentes intraoculares (LIO) trifocales, que funcionan muy bien, algunos de los pacientes a quienes se les ha implantado un LIO monofocal (lo que aún ocurre en un alto porcentaje de los casos en nuestro medio) desean explorar la posibilidad de un procedimiento quirúrgico para mejorar la visión intermedia y cercana. El objetivo de este estudio es describir el resultado del segundo caso en Colombia de implante de un LIO trifocal piggyback (1stQ AddOn, Medicontour Medical Engineering Ltd, Hungría) para mejorar la visión en una paciente joven previamente sometida a facoemulsificación de implante de LIO monofocal. Como resultado, se alcanzó una excelente agudeza visual sin corrección, logrando una gran satisfacción e independencia completa de anteojos para todas las distancias. El uso de este tipo de lentes es un abordaje fácil, seguro y efectivo para brindar trifocalidad en pacientes previamente sometidos a facoemulsificación de cristalino con implante de LIO monofocal que deseen mejorar su dependencia a anteojos.
- 12 December 2023
- Published by Instituto Mexicano del Seguro Social in Revista de la Sociedad Colombiana de Oftalmología
- Vol. 56 (3)
Open AccessImplante de lente trifocal en piggyback para brindar trifocalidad en paciente con cirugía previa
CLÍNICO Resumen Ante la disponibilidad de plataformas de lentes intraoculares (LIO) trifocales, que funcionan muy bien, algunos de los pacientes a quienes se les ha implantado un LIO monofocal (lo que aún ocurre en un alto porcentaje de los casos en nuestro medio) desean explorar la posibilidad de un procedimiento quirúrgico para mejorar la visión intermedia y cercana. El objetivo de este estudio es describir el resultado del segundo caso en Colombia de implante de un LIO trifocal piggyback (1stQ AddOn, Medicontour Medical Engineering Ltd, Hungría) para mejorar la visión en una paciente joven previamente sometida a facoemulsificación de implante de LIO monofocal. Como resultado, se alcanzó una excelente agudeza visual sin corrección, logrando una gran satisfacción e independencia completa de anteojos para todas las distancias. El uso de este tipo de lentes es un abordaje fácil, seguro y efectivo para brindar trifocalidad en pacientes previamente sometidos a facoemulsificación de cristalino con implante de LIO monofocal que deseen mejorar su dependencia a anteojos.
- Open Access
- 22 November 2023
- Published by Instituto Mexicano del Seguro Social in Revista de la Sociedad Colombiana de Oftalmología
- Vol. 56 (2)
Mejoría de la calidad visual, corneal y refractiva en queratocono por medio del protocolo de Atenas
R e v i s t a Resumen Se presenta el caso de un paciente con queratocono, con distorsión corneal moderada, quien es sometido a cirugía PRK guiada por topografía con crosslinking (protocolo de Atenas), con un excelente resultado anatómico y funcional. Se reportan las imágenes de tomografía de Scheimpflug y la simulación de calidad visual basada en aberrometría Hartmann-Shack.
- 22 November 2023
- Published by Instituto Mexicano del Seguro Social in Revista de la Sociedad Colombiana de Oftalmología
- Vol. 56 (2)
Open AccessMejoría de la calidad visual, corneal y refractiva en queratocono por medio del protocolo de Atenas
R e v i s t a Resumen Se presenta el caso de un paciente con queratocono, con distorsión corneal moderada, quien es sometido a cirugía PRK guiada por topografía con crosslinking (protocolo de Atenas), con un excelente resultado anatómico y funcional. Se reportan las imágenes de tomografía de Scheimpflug y la simulación de calidad visual basada en aberrometría Hartmann-Shack.
- 7 August 2023
- Published by Springer Nature in International Ophthalmology
- Vol. 43 (11) , 4087-4096
Ocular residual astigmatism (ORA) does not seem to correlate with baseline refractive error among refractive surgery candidates
Purpose Ocular residual astigmatism (ORA) is defined as the difference between refractive astigmatism and anterior corneal astigmatism. A high ORA may be correlated with poorer results in patients undergoing corneal-based laser surgery. Is a high baseline refractive error related to a higher degree of ORA? Methods This was a retrospective analytical study including 181 right eyes of an equal number of refractive surgery candidates. Manifest subjective refraction was measured, along with a Pentacam AXL Wave corneal tomography. Via a vector analysis with this methodology, subjective cylinder was translated into the corneal plane and a vectorial subtraction was performed in order to measure ORA. Spearman’s rank order test, one-way ANOVA and Chi-square were used to determine whether different levels of baseline refractive error correlate with different levels of ORA. Results Mean age was 28.33 ± 4.71 years with a female preponderance (65.7%). Mean ORA was 0.74 ± 0.39 D, with 33.1% of eyes having an ORA ≥ 0.90 D. There was not a correlation between ORA and level of myopia (rho = − 0.022; p = 0.764), nor between ORA and spherical equivalent (rho = 0.009; p = 0.903). Refractive astigmatism did not demonstrate to be correlated with ORA level either (rho = 0.078; p = 0.329). One-way ANOVA tests failed to demonstrate an association between different classifications of refractive error and level of ORA. Conclusions In the studied population, ORA is not correlated with baseline refractive error. Every patient presenting for possible corneal-based laser refractive surgery should be evaluated for a possible high level of ORA, irrespective of their baseline ametropia level.
- 7 August 2023
- Published by Springer Nature in International Ophthalmology
- Vol. 43 (11) , 4087-4096
Ocular residual astigmatism (ORA) does not seem to correlate with baseline refractive error among refractive surgery candidates
Purpose Ocular residual astigmatism (ORA) is defined as the difference between refractive astigmatism and anterior corneal astigmatism. A high ORA may be correlated with poorer results in patients undergoing corneal-based laser surgery. Is a high baseline refractive error related to a higher degree of ORA? Methods This was a retrospective analytical study including 181 right eyes of an equal number of refractive surgery candidates. Manifest subjective refraction was measured, along with a Pentacam AXL Wave corneal tomography. Via a vector analysis with this methodology, subjective cylinder was translated into the corneal plane and a vectorial subtraction was performed in order to measure ORA. Spearman’s rank order test, one-way ANOVA and Chi-square were used to determine whether different levels of baseline refractive error correlate with different levels of ORA. Results Mean age was 28.33 ± 4.71 years with a female preponderance (65.7%). Mean ORA was 0.74 ± 0.39 D, with 33.1% of eyes having an ORA ≥ 0.90 D. There was not a correlation between ORA and level of myopia (rho = − 0.022; p = 0.764), nor between ORA and spherical equivalent (rho = 0.009; p = 0.903). Refractive astigmatism did not demonstrate to be correlated with ORA level either (rho = 0.078; p = 0.329). One-way ANOVA tests failed to demonstrate an association between different classifications of refractive error and level of ORA. Conclusions In the studied population, ORA is not correlated with baseline refractive error. Every patient presenting for possible corneal-based laser refractive surgery should be evaluated for a possible high level of ORA, irrespective of their baseline ametropia level.
- Open Access
- 5 April 2023
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (4) , 1432-1440
Rasch development and validation of the “Medellín Dry Eye Inventory” (ME·Dry), an instrument to measure multidimensional quality of life compromise in patients with dry eye disease
Purpose: Dry eye disease (DED) is a common condition that affects the quality of life. There is a great need for better-developed scales that comply with Rasch model requirements. Methods: Prospective study including patients with DED. A series of focus groups were performed to determine the best items to be included. A Rasch modeling methodology was used to validate the Medellín Dry Eye Inventory (ME·Dry). After iterative analysis and scale modification, a final version of the scale was attained which complied with the Rasch analysis expectations. Correlation between the different subscales of the ME·Dry and the Ocular Surface Disease Index (OSDI) was evaluated through Spearman correlation. Results: A total of 166 patients with DED were included. Rasch modeling demonstrated an excellent behavior for the ME·Dry, including four subscales: Symptoms, Triggers, Activity Limitation, and Emotional Compromise. Infit and Outfit parameters were all between 0.50 and 1.50, with excellent category utilization. Person and item separation and reliability were excellent for all subscales. There was a need for a category collapsing for the Emotional Compromise subscale. There was a strong correlation between the different subscales of the ME·Dry except for the Emotional Compromise subscale, which seems to be independent. Conclusion: The ME·Dry is a reliable scale, complying with the Rasch model expectations, that allows for a reliable measurement of quality of life compromise in patients with DED. Emotional compromise secondary to DED does not seem to correlate with disease severity as assessed by the other quality-of-life subscales.
- 5 April 2023
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (4) , 1432-1440
Open AccessRasch development and validation of the “Medellín Dry Eye Inventory” (ME·Dry), an instrument to measure multidimensional quality of life compromise in patients with dry eye disease
Purpose: Dry eye disease (DED) is a common condition that affects the quality of life. There is a great need for better-developed scales that comply with Rasch model requirements. Methods: Prospective study including patients with DED. A series of focus groups were performed to determine the best items to be included. A Rasch modeling methodology was used to validate the Medellín Dry Eye Inventory (ME·Dry). After iterative analysis and scale modification, a final version of the scale was attained which complied with the Rasch analysis expectations. Correlation between the different subscales of the ME·Dry and the Ocular Surface Disease Index (OSDI) was evaluated through Spearman correlation. Results: A total of 166 patients with DED were included. Rasch modeling demonstrated an excellent behavior for the ME·Dry, including four subscales: Symptoms, Triggers, Activity Limitation, and Emotional Compromise. Infit and Outfit parameters were all between 0.50 and 1.50, with excellent category utilization. Person and item separation and reliability were excellent for all subscales. There was a need for a category collapsing for the Emotional Compromise subscale. There was a strong correlation between the different subscales of the ME·Dry except for the Emotional Compromise subscale, which seems to be independent. Conclusion: The ME·Dry is a reliable scale, complying with the Rasch model expectations, that allows for a reliable measurement of quality of life compromise in patients with DED. Emotional compromise secondary to DED does not seem to correlate with disease severity as assessed by the other quality-of-life subscales.
- Open Access
- 30 December 2022
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (1) , 63-68
Determination of the repeatability of corneal densitometry as measured with a Scheimpflug camera device in refractive surgery candidates
Purpose: Corneal densitometry analysis provides an objective measurement of corneal transparency in patients undergoing photorefractive keratectomy (PRK). To date, no study that focuses on determining the reliability and smallest real difference (SRD), specifically in PRK candidates, has been published. Methods: The study was conducted at Clínica de Oftalmología Sandiego, Medellín, Colombia. This was a prospective and analytical study. Refractive surgery candidates underwent Pentacam measurements twice with five minutes of difference. Repeatability of measurements was evaluated for every area using Wilcoxon signed-rank test, Spearman’s rank-order correlation, and the intraclass correlation coefficient, followed by a within-subjects factor (Sw) finishing with a determination of the SRD for all areas. Bland–Altman plots were created and analyzed. Results: A total of 110 eyes were included. The mean total densitometry was 18.67 ± 1.56 grayscale units (GSU) and 18.65 ± 1.49 GSU for the first and second measurements, respectively. Wilcoxon was non-significant (P > 0.05) while the intraclass correlation coefficient demonstrated an excellent agreement. SRD ranged from 0.21 GSU (posterior × 6–10 mm) to 1.79 GSU (total × 10–12 mm). Anterior depths and 10–12 mm annulus had consistently more variability and greater (worse) SRD. The 10–12 mm annulus showed great dispersion on the Bland–Altman plots. Conclusion: Corneal densitometry has an excellent repeatability in refractive surgery candidates for areas below 10 mm. Any densitometry change ≥1.0 GSU in areas under 10 mm should be considered as well above measurement noise and corresponding to a real change in measured parameters. The 10–12 mm area does not seem to be reliable enough in refractive surgery candidates to warrant surveillance after corneal-based surgery.
- 30 December 2022
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (1) , 63-68
Open AccessDetermination of the repeatability of corneal densitometry as measured with a Scheimpflug camera device in refractive surgery candidates
Purpose: Corneal densitometry analysis provides an objective measurement of corneal transparency in patients undergoing photorefractive keratectomy (PRK). To date, no study that focuses on determining the reliability and smallest real difference (SRD), specifically in PRK candidates, has been published. Methods: The study was conducted at Clínica de Oftalmología Sandiego, Medellín, Colombia. This was a prospective and analytical study. Refractive surgery candidates underwent Pentacam measurements twice with five minutes of difference. Repeatability of measurements was evaluated for every area using Wilcoxon signed-rank test, Spearman’s rank-order correlation, and the intraclass correlation coefficient, followed by a within-subjects factor (Sw) finishing with a determination of the SRD for all areas. Bland–Altman plots were created and analyzed. Results: A total of 110 eyes were included. The mean total densitometry was 18.67 ± 1.56 grayscale units (GSU) and 18.65 ± 1.49 GSU for the first and second measurements, respectively. Wilcoxon was non-significant (P > 0.05) while the intraclass correlation coefficient demonstrated an excellent agreement. SRD ranged from 0.21 GSU (posterior × 6–10 mm) to 1.79 GSU (total × 10–12 mm). Anterior depths and 10–12 mm annulus had consistently more variability and greater (worse) SRD. The 10–12 mm annulus showed great dispersion on the Bland–Altman plots. Conclusion: Corneal densitometry has an excellent repeatability in refractive surgery candidates for areas below 10 mm. Any densitometry change ≥1.0 GSU in areas under 10 mm should be considered as well above measurement noise and corresponding to a real change in measured parameters. The 10–12 mm area does not seem to be reliable enough in refractive surgery candidates to warrant surveillance after corneal-based surgery.