Marina V Voinova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marina V Voinova has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
A Isacsson
Department of Applied Physics, Chalmers University of Technology and Göteborg University, S-412 96 Göteborg, Sweden
1 shared publication- Andrew G. Ewing
Department of Chemistry and Molecular Biology University of Gothenburg Gothenburg Sweden
1 shared publication - Ann-Sofie Cans
Department of Chemistry and Chemical Engineering, Chalmers University of Technology, Kemigården 4, SE-412 96 Gothenburg, Sweden
1 shared publication B Kasemo
Department of Applied Physics, Chalmers University of Technology and Göteborg University, S-412 96 Göteborg, Sweden
1 shared publication- Bogdan V. Tkachuk
Department of Industrial and Biomedical Electronics, National Technical University "Kharkiv Polytechnic Institute
1 shared publication - Evgen Sokol
National Technical University “Kharkiv Polytechnic Institute,”, Kharkiv, Ukraine
1 shared publication
Latest Publications
- Open Access
Physical Processes in Polymeric Filters Used for Dialysis
The key physical processes in polymeric filters used for the blood purification include transport across the capillary wall and the interaction of blood cells with the polymer membrane surface. Theoretical modeling of membrane transport is an important tool which provides researchers with a quantification of the complex phenomena involved in dialysis. In the paper, we present a dense review of the most successful theoretical approaches to the description of transport across the polymeric membrane wall as well as the cell–polymer surface interaction, and refer to the corresponding experimental methods while studying these phenomena in dialyzing filters.
Open AccessPhysical Processes in Polymeric Filters Used for Dialysis
The key physical processes in polymeric filters used for the blood purification include transport across the capillary wall and the interaction of blood cells with the polymer membrane surface. Theoretical modeling of membrane transport is an important tool which provides researchers with a quantification of the complex phenomena involved in dialysis. In the paper, we present a dense review of the most successful theoretical approaches to the description of transport across the polymeric membrane wall as well as the cell–polymer surface interaction, and refer to the corresponding experimental methods while studying these phenomena in dialyzing filters.
- 1 June 2018
- Published by Elsevier in Urban Climate
- Vol. 24, 264-275
The theory of acoustic sensors application in air quality control
- 1 June 2018
- Published by Elsevier in Urban Climate
- Vol. 24, 264-275
The theory of acoustic sensors application in air quality control
- Open Access
- 6 April 2015
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 4 (1) , 137-142
Modelling of the response of acoustic piezoelectric resonators in biosensor applications – Part 1: The general theoretical analysis
Acoustic piezoelectric resonators are widely used as precise analytical chemistry tools for the real-time monitoring of a negligibly small amount of surface-attached mass of biological components, in particular, in environmental biosensor measurements. The surface acoustic wave (SAW)-based sensors and the quartz crystal microbalance (QCM) compared in our work belong to the leading group due to their considerable advantages. These piezoelectric resonators are considered now as high-resolution analytical tools allowing researchers to discriminate between components due to the selective polymer coating on the resonator surface. The gravimetrical measurements performed with the SAW-based or QCM sensors provide the experimental data with high precision for the detection of surface mass for the thin adsorbed layer rigidly attached to the oscillator surface. The new challenge is the analysis of soft and biological materials, where the viscous losses of energy can essentially influence measured characteristics. Modelling is the important part of the analysis allowing researchers to quantify the results of the experiments. The present work provides a general theory of SH-SAW devices probing soft and biological materials. The results are compared with QCM-D operated in liquid media.
- 6 April 2015
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 4 (1) , 137-142
Open AccessModelling of the response of acoustic piezoelectric resonators in biosensor applications – Part 1: The general theoretical analysis
Acoustic piezoelectric resonators are widely used as precise analytical chemistry tools for the real-time monitoring of a negligibly small amount of surface-attached mass of biological components, in particular, in environmental biosensor measurements. The surface acoustic wave (SAW)-based sensors and the quartz crystal microbalance (QCM) compared in our work belong to the leading group due to their considerable advantages. These piezoelectric resonators are considered now as high-resolution analytical tools allowing researchers to discriminate between components due to the selective polymer coating on the resonator surface. The gravimetrical measurements performed with the SAW-based or QCM sensors provide the experimental data with high precision for the detection of surface mass for the thin adsorbed layer rigidly attached to the oscillator surface. The new challenge is the analysis of soft and biological materials, where the viscous losses of energy can essentially influence measured characteristics. Modelling is the important part of the analysis allowing researchers to quantify the results of the experiments. The present work provides a general theory of SH-SAW devices probing soft and biological materials. The results are compared with QCM-D operated in liquid media.
- Open Access
- 14 June 2011
- Published by Springer Nature in Discover Nano
- Vol. 6 (1) , 421
Mechanics of lipid bilayer junctions affecting the size of a connecting lipid nanotube
In this study we report a physical analysis of the membrane mechanics affecting the size of the highly curved region of a lipid nanotube (LNT) that is either connected between a lipid bilayer vesicle and the tip of a glass microinjection pipette (tube-only) or between a lipid bilayer vesicle and a vesicle that is attached to the tip of a glass microinjection pipette (two-vesicle). For the tube-only configuration (TOC), a micropipette is used to pull a LNT into the interior of a surface-immobilized vesicle, where the length of the tube L is determined by the distance of the micropipette to the vesicle wall. For the two-vesicle configuration (TVC), a small vesicle is inflated at the tip of the micropipette tip and the length of the tube L is in this case determined by the distance between the two interconnected vesicles. An electrochemical method monitoring diffusion of electroactive molecules through the nanotube has been used to determine the radius of the nanotube R as a function of nanotube length L for the two configurations. The data show that the LNT connected in the TVC constricts to a smaller radius in comparison to the tube-only mode and that tube radius shrinks at shorter tube lengths. To explain these electrochemical data, we developed a theoretical model taking into account the free energy of the membrane regions of the vesicles, the LNT and the high curvature junctions. In particular, this model allows us to estimate the surface tension coefficients from R(L) measurements.
- 14 June 2011
- Published by Springer Nature in Discover Nano
- Vol. 6 (1) , 421
Open AccessMechanics of lipid bilayer junctions affecting the size of a connecting lipid nanotube
In this study we report a physical analysis of the membrane mechanics affecting the size of the highly curved region of a lipid nanotube (LNT) that is either connected between a lipid bilayer vesicle and the tip of a glass microinjection pipette (tube-only) or between a lipid bilayer vesicle and a vesicle that is attached to the tip of a glass microinjection pipette (two-vesicle). For the tube-only configuration (TOC), a micropipette is used to pull a LNT into the interior of a surface-immobilized vesicle, where the length of the tube L is determined by the distance of the micropipette to the vesicle wall. For the two-vesicle configuration (TVC), a small vesicle is inflated at the tip of the micropipette tip and the length of the tube L is in this case determined by the distance between the two interconnected vesicles. An electrochemical method monitoring diffusion of electroactive molecules through the nanotube has been used to determine the radius of the nanotube R as a function of nanotube length L for the two configurations. The data show that the LNT connected in the TVC constricts to a smaller radius in comparison to the tube-only mode and that tube radius shrinks at shorter tube lengths. To explain these electrochemical data, we developed a theoretical model taking into account the free energy of the membrane regions of the vesicles, the LNT and the high curvature junctions. In particular, this model allows us to estimate the surface tension coefficients from R(L) measurements.
- 1 June 1998
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 249-251, 197-200
Micro-mechanical charge transfer mechanism in soft Coulomb blockade nanostructures
- 1 June 1998
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 249-251, 197-200
Micro-mechanical charge transfer mechanism in soft Coulomb blockade nanostructures
- 1 July 1996
- Published by Elsevier in Thermochimica Acta
- Vol. 280-281, 465-477
The theory of membrane “vitrification”
- 1 July 1996
- Published by Elsevier in Thermochimica Acta
- Vol. 280-281, 465-477
The theory of membrane “vitrification”