AHAndrew Hill

Andrew Hill

*This is an algorithmically generated author record based on publicly available information.

Andrew Hill has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A human factors approach to subcutaneous insulin chart design improves user-performance: An experimental study

    by Andrew Hill, Sophie J. Francis, Mark S. Horswill, Melany J. Christofidis, Marcus O. Watson


  • Open Access

    The Use of Head-Worn Displays for Vital Sign Monitoring in Critical and Acute Care: Systematic Review

    by Francine Elrose, Andrew Hill, David Liu, Isaac Salisbury, Thien LeCong, Robert G Loeb, Penelope Sanderson

    Background: Continuous monitoring of patient vital signs may improve patient outcomes. Head-worn displays (HWDs) can provide hands-free access to continuous vital sign information of patients in critical and acute care contexts and thus may reduce instances of unrecognized patient deterioration. Objective: The purpose of the study is to conduct a systematic review of the literature to evaluate clinical, surrogate, and process outcomes when clinicians use HWDs for continuous patient vital sign monitoring. Methods: The review was registered with PROSPERO (CRD42019119875) and followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines. A literature search was conducted for articles published between January 1995 and June 2020 using the following databases: PubMed, Embase, CINAHL, PsycINFO, and Web of Science. Overall, 2 reviewers independently screened titles and abstracts and then assessed the full text of the articles. Original research articles that evaluated the clinical, surrogate, or process outcomes of head-mounted displays for continuous vital sign monitoring in critical care or acute care contexts were included. Results: Of the 214 records obtained, 15 (7%) articles met the predefined criteria and were included in this review. Of the 15 studies, 7 (47%) took place in a clinical context, whereas the remainder took place in a simulation environment. In 100% (7/7) of the studies that evaluated gaze behavior, changes were found in gaze direction with HWDs. Change detection improvements were found in 67% (2/3) of the studies evaluating changes in the participants’ ability to detect changes in vital signs. Of the 10 studies assessing the ease of use of the HWD, most participants of 7 (70%) studies reported that the HWD was easy to use. In all 6 studies in which participants were asked if they would consider using the HWD in their practice, most participants responded positively, but they often suggested improvements on the HWD hardware or display design. Of the 7 studies conducted in clinical contexts, none reported any clinical outcomes. Conclusions: Although there is limited and sometimes conflicting evidence about the benefits of HWDs from certain surrogate and process outcomes, evidence for clinical outcomes is lacking. Recommendations are to employ user-centered design when developing HWDs, perform longitudinal studies, and seek clinical outcomes. Trial Registration: PROSPERO International Prospective Register of Systematic Reviews CRD42019119875; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=119875


  • Open Access

    The Use of Head-Worn Displays for Vital Sign Monitoring in Critical and Acute Care: Systematic Review (Preprint)

    by Francine Elrose, Andrew Hill, David Liu, Isaac Salisbury, Thien LeCong, Robert G Loeb, Penelope Sanderson

    BACKGROUND Continuous monitoring of patient vital signs may improve patient outcomes. Head-worn displays (HWDs) can provide hands-free access to continuous vital sign information of patients in critical and acute care contexts and thus may reduce instances of unrecognized patient deterioration. OBJECTIVE The purpose of the study is to conduct a systematic review of the literature to evaluate clinical, surrogate, and process outcomes when clinicians use HWDs for continuous patient vital sign monitoring. METHODS The review was registered with PROSPERO (CRD42019119875) and followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines. A literature search was conducted for articles published between January 1995 and June 2020 using the following databases: PubMed, Embase, CINAHL, PsycINFO, and Web of Science. Overall, 2 reviewers independently screened titles and abstracts and then assessed the full text of the articles. Original research articles that evaluated the clinical, surrogate, or process outcomes of head-mounted displays for continuous vital sign monitoring in critical care or acute care contexts were included. RESULTS Of the 214 records obtained, 15 (7%) articles met the predefined criteria and were included in this review. Of the 15 studies, 7 (47%) took place in a clinical context, whereas the remainder took place in a simulation environment. In 100% (7/7) of the studies that evaluated gaze behavior, changes were found in gaze direction with HWDs. Change detection improvements were found in 67% (2/3) of the studies evaluating changes in the participants’ ability to detect changes in vital signs. Of the 10 studies assessing the ease of use of the HWD, most participants of 7 (70%) studies reported that the HWD was easy to use. In all 6 studies in which participants were asked if they would consider using the HWD in their practice, most participants responded positively, but they often suggested improvements on the HWD hardware or display design. Of the 7 studies conducted in clinical contexts, none reported any clinical outcomes. CONCLUSIONS Although there is limited and sometimes conflicting evidence about the benefits of HWDs from certain surrogate and process outcomes, evidence for clinical outcomes is lacking. Recommendations are to employ user-centered design when developing HWDs, perform longitudinal studies, and seek clinical outcomes. CLINICALTRIAL PROSPERO International Prospective Register of Systematic Reviews CRD42019119875; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=119875


  • Improving E. coli Bactofection by Expression of Bacteriophage ΦX174 Gene E

    by Dongwon Park, Andrew Hill, Blaine A. Pfeifer

    Bactofection, a bacterial-mediated form of genetic transfer, is highlighted as an alternative mechanism for gene therapy. A key advantage of this system for immune-reactivity purposes stems from the nature of the bacterial host capable of initiating an immune response by attracting recognition and cellular uptake by antigen-presenting cells (APCs). The approach is also a suitable technique to deliver larger genetic constructs more efficiently as it can transfer plasmids of varying sizes into target mammalian cells. Given these advantages, bacterial vectors are being studied as potential carriers for the delivery of plasmid DNA into target cells to enable expression of heterologous proteins. The bacteria used for bactofection are generally nonpathogenic; however, concerns arise due to the use of a biological agent. To overcome such concerns, enhanced bacterial degradation has been engineered as an attenuation and safety feature for bactofection vectors. In particular, the ΦX174 lysis E (LyE) gene can be repurposed to both minimize bacterial survival within mammalian hosts while also improving overall gene delivery. More specifically, an engineered bacterial vector carrying the LyE gene showed improved gene delivery and safety profiles when tested with murine RAW264.7 macrophage APCs. This chapter outlines steps taken to engineer E. coli for LyE expression as a safer and more effective genetic antigen delivery bactofection vehicle in the context of vaccine utility.

  • Open Access

    Quantitative systematic review: Sources of inaccuracy in manually measured adult respiratory rate data

    by Noa Kallioinen, Andrew Hill, Melany J. Christofidis, Mark S. Horswill, Marcus O. Watson

    Aims: To identify the potential sources of inaccuracy in manually measured adult respiratory rate (RR) data and quantify their effects.Design: Quantitative systematic review with meta‐analyses where appropriate.Data Sources: Medline, CINAHL, and Cochrane Library (from database inception to 31 July 2019).Review Methods: Studies presenting data on individual sources of inaccuracy in the manual measurement of adult RR were analysed, assessed for quality, and grouped according to the source of inaccuracy investigated. Quantitative data were extracted and synthesized and meta‐analyses performed where appropriate.Results: Included studies (N = 49) identified five sources of inaccuracy. Theawareness effectcreates an artefactual reduction in actual RR, andobservation methodsinvolving shorter counts cause systematic underscoring. Individual RR measurements can differ substantially in either direction between observations due tointer‐orintra‐observer variability.Value bias, where particular RRs are over‐represented (suggesting estimation), is a widespread problem.Recording omissionis also widespread, with higher average rates in inpatient versus triage/admission contexts.Conclusion: This review demonstrates that manually measured RR data are subject to several potential sources of inaccuracy.Impact: RR is an important indicator of clinical deterioration and commonly included in track‐and‐trigger systems. However, the usefulness of RR data depends on the accuracy of the observations and documentation, which are subject to five potential sources of inaccuracy identified in this review. A single measurement may be affected by several factors. Hence, clinicians should interpret recorded RR data cautiously unless systems are in place to ensure its accuracy. For nurses, this includes counting rather than estimating RRs, employing 60‐s counts whenever possible, ensuring patients are unaware that their RR is being measured, and documenting the resulting value. For any given site, interventions to improve measurement should take into account the local organizational and cultural context, available resources, and the specific measurement issues that need to be addressed.


  • Open Access

    Improving the Quality of Evaluation Data in Simulation-Based Healthcare Improvement Projects

    by Chiara M. Santomauro, Andrew Hill, Tara McCurdie, Hannah L. MPsych McGlashan

    Summary Statement: Simulation is increasingly being used in healthcare improvement projects. The aims of such projects can be extremely diverse. Accordingly, the outcomes or participant attributes that need to be measured can vary dramatically from project-to-project and may include a wide range of nontechnical skills, technical skills, and psychological constructs. Consequently, there is a growing need for simulation practitioners to be able to identify suitable measurement tools and incorporate them into their work. This article provides a practical introduction and guide to the key considerations for practitioners when selecting and using such tools. It also offers a substantial selection of example tools, both to illustrate the key considerations in relation to choosing a measure (including reliability and validity) and to serve as a convenient resource for those planning a study. By making well-informed choices, practitioners can improve the quality of the data they collect, and the likelihood that their projects will succeed.


  • Open Access

    Eye-tracking reveals how observation chart design features affect the detection of patient deterioration: An experimental study

    by Lillian Cornish, Andrew Hill, Mark S. Horswill, Stefanie I. Becker, Marcus O. Watson


  • Open Access

    Assessing colonoscopic inspection skill using a virtual withdrawal simulation: a preliminary validation of performance metrics

    by Christine M. Zupanc, Guy M. Wallis, Andrew Hill, Robin Burgess-Limerick, Stephan Riek, Annaliese M. Plooy, Mark S. Horswill, Marcus O. Watson, Hans de Visser, David Conlan, et al.

    The effectiveness of colonoscopy for diagnosing and preventing colon cancer is largely dependent on the ability of endoscopists to fully inspect the colonic mucosa, which they achieve primarily through skilled manipulation of the colonoscope during withdrawal. Performance assessment during live procedures is problematic. However, a virtual withdrawal simulation can help identify and parameterise actions linked to successful inspection, and offer standardised assessments for trainees. Eleven experienced endoscopists and 18 endoscopy novices (medical students) completed a mucosal inspection task during three simulated colonoscopic withdrawals. The two groups were compared on 10 performance metrics to preliminarily assess the validity of these measures to describe inspection quality. Four metrics were related to aspects of polyp detection: percentage of polyp markers found; number of polyp markers found per minute; percentage of the mucosal surface illuminated by the colonoscope (≥0.5 s); and percentage of polyp markers illuminated (≥2.5 s) but not identified. A further six metrics described the movement of the colonoscope: withdrawal time; linear distance travelled by the colonoscope tip; total distance travelled by the colonoscope tip; and distance travelled by the colonoscope tip due to movement of the up/down angulation control, movement of the left/right angulation control, and axial shaft rotation. Statistically significant experienced-novice differences were found for 8 of the 10 performance metrics (p’s < .005). Compared with novices, experienced endoscopists inspected more of the mucosa and detected more polyp markers, at a faster rate. Despite completing the withdrawals more quickly than the novices, the experienced endoscopists also moved the colonoscope more in terms of linear distance travelled and overall tip movement, with greater use of both the up/down angulation control and axial shaft rotation. However, the groups did not differ in the number of polyp markers visible on the monitor but not identified, or movement of the left/right angulation control. All metrics that yielded significant group differences had adequate to excellent internal consistency reliability (α = .79 to .90). These systematic differences confirm the potential of the simulated withdrawal task for evaluating inspection skills and strategies. It may be useful for training, and assessment of trainee competence.