RDRasmus Holmboe Dahl

Rasmus Holmboe Dahl

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rasmus Holmboe Dahl has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Non-restrictive cerebral venous dysgenesis in an 11-year-old girl: a case report

    by Maryam Mozaffari, Rasmus Holmboe Dahl, Malene Landbo Børresen, Tina Duelund Hjortshøj, Goetz Benndorf

    Restrictive cerebral venopathy was recently described in a young patient with cerebral venous ischemia, elevated intracranial pressure, and intracranial calcifications. It was anatomically characterized by extensive formation of tortuous small to medium-sized cortical veins and angiographic absence of the deep venous system. We report similar, albeit not identical, angiographic features in an 11-year-old girl with infantile autism, attention deficit disorder, dyslexia, and camptodactyly. Angiography revealed a venous anomaly characterized by diffuse marked tortuousities involving mainly pial and small cortical veins, partial maldevelopment of the deep venous system, and aplasia of the transverse sinuses. Magnetic resonance imaging showed no signs of venous ischemia. Genetic analyses identified a complex rearrangement involving three chromosomal segments. In conclusion, a unique case of non-restrictive cerebral venous dysgenesis associated with chromotripsis is presented.


  • Open Access

    Damage to Polymer Coatings on Microguidewire Tips through Shaping and J-wiring for Optimizing Flow Diverter Deployment: A Scanning Electron Microscopy Study

    by Rasmus Holmboe Dahl, Esben Thormann, René Wugt Larsen, Goetz Benndorf

    Achieving adequate wall apposition is a crucial technical goal when deploying flow diverters to treat wide-neck cerebral aneurysms. The socalled J-wiring technique is a common method used to optimize flow diverter wall apposition. However, the frictional interaction between the shaping device and the microguidewire tip during the formation of the J-loop, as well as the interaction between the J-loop and the flow diverter during J-wiring, may potentially cause damage to the guidewire’s coating. Three frequently used guidewires were tested in vitro in a silicone aneurysm model. Manual J-shaping of guidewire tips, along with the J-wiring technique (including J-shaping), caused damage to the surface coating of guidewires, as observed by scanning electron microscopy. Therefore, both mechanisms may contribute to the generation of polymer micro-fragments in patients treated with flow diversion.

  • Open Access

    Transfistulous coil occlusion of high-grade tentorial dural arteriovenous fistulas: An effective alternative to liquid embolic agents

    by Rasmus Holmboe Dahl, Vagn Eskesen, Lars Poulsgaard, Markus Engebæk Krogager, Goetz Benndorf

  • Open Access

    Blistering barnacles: Space physiology in The Adventures of Tintin

    by Jacob P. Hartmann, Mathis B. Mottelson, Rasmus H. Dahl, Ronni R. Plovsing, Ronan M. G. Berg


  • Open Access

    Endovascular Management of a Ruptured Aneurysm on a Posterior Inferior Cerebellar Artery with Extradural C2-Origin: Case Report and Literature Review

    by Rasmus Holmboe Dahl, Gary Lloyd Horn Jr, Zeyad Metwalli, Shankar Prakash Gopinath, Goetz Benndorf

    Extracranial vascular pathology uncommonly causes intracranial subarachnoid hemorrhage (SAH). Among possible lesions are aneurysms at the craniocervical junction arising from a posterior inferior cerebellar artery (PICA) with an extradural origin. We describe a case of a 55-year-old female presenting with a sudden and severe headache. A computed tomography scan revealed a SAH within the fourth ventricle and cervical spinal canal, and a ruptured saccular aneurysm on a PICA with extradural C2-origin. Despite difficult access anatomy, endovascular treatment was feasible and resulted in subtotal initial occlusion and preservation of distal PICA flow. Upon 3-month follow-up, the aneurysm was completely occluded with a patent PICA. The patient’s clinical status remained stable at the 1.5-year follow-up. In conclusion, we present a rare case of an aneurysm originating from a PICA with extradural C2-origin that was treated endovascularly with preservation of the PICA.


  • Open Access

    Severe hypoxaemic hypercapnia compounds cerebral oxidative–nitrosative stress during extreme apnoea: Implications for cerebral bioenergetic function

    by Damian M. Bailey, Anthony R. Bain, Ryan L. Hoiland, Otto F. Barak, Ivan Drvis, Benjamin S. Stacey, Angelo Iannetelli, Gareth W. Davison, Rasmus H. Dahl, Ronan M. G. Berg, et al.

    We examined the extent to which apnoea‐induced extremes of oxygen demand/carbon dioxide production impact redox regulation of cerebral bioenergetic function. Ten ultra‐elite apnoeists (six men and four women) performed two maximal dry apnoeas preceded by normoxic normoventilation, resulting in severe end‐apnoea hypoxaemic hypercapnia, and hyperoxic hyperventilation designed to ablate hypoxaemia, resulting in hyperoxaemic hypercapnia. Transcerebral exchange of ascorbate radicals (by electron paramagnetic resonance spectroscopy) and nitric oxide metabolites (by tri‐iodide chemiluminescence) were calculated as the product of global cerebral blood flow (by duplex ultrasound) and radial arterial (a) to internal jugular venous (v) concentration gradients. Apnoea duration increased from 306 ± 62 s during hypoxaemic hypercapnia to 959 ± 201 s in hyperoxaemic hypercapnia (P ≤ 0.001). Apnoea generally increased global cerebral blood flow (all P ≤ 0.001) but was insufficient to prevent a reduction in the cerebral metabolic rates of oxygen and glucose (P = 0.015–0.044). This was associated with a general net cerebral output (v > a) of ascorbate radicals that was greater in hypoxaemic hypercapnia (P = 0.046 vs. hyperoxaemic hypercapnia) and coincided with a selective suppression in plasma nitrite uptake (a > v) and global cerebral blood flow (P = 0.034 to vs. hyperoxaemic hypercapnia), implying reduced consumption and delivery of nitric oxide consistent with elevated cerebral oxidative–nitrosative stress. In contrast, we failed to observe equidirectional gradients consistent with S‐nitrosohaemoglobin consumption and plasma S‐nitrosothiol delivery during apnoea (all P ≥ 0.05). Collectively, these findings highlight a key catalytic role for hypoxaemic hypercapnia in cerebral oxidative–nitrosative stress. image Key points: Local sampling of blood across the cerebral circulation in ultra‐elite apnoeists determined the extent to which severe end‐apnoea hypoxaemic hypercapnia (prior normoxic normoventilation) and hyperoxaemic hypercapnia (prior hyperoxic hyperventilation) impact free radical‐mediated nitric oxide bioavailability and global cerebral bioenergetic function. Apnoea generally increased the net cerebral output of free radicals and suppressed plasma nitrite consumption, thereby reducing delivery of nitric oxide consistent with elevated oxidative–nitrosative stress. The apnoea‐induced elevation in global cerebral blood flow was insufficient to prevent a reduction in the cerebral metabolic rates of oxygen and glucose. Cerebral oxidative–nitrosative stress was greater during hypoxaemic hypercapnia compared with hyperoxaemic hypercapnia and coincided with a lower apnoea‐induced elevation in global cerebral blood flow, highlighting a key catalytic role for hypoxaemia. This applied model of voluntary human asphyxia might have broader implications for the management and treatment of neurological diseases characterized by extremes of oxygen demand and carbon dioxide production.


  • Open Access

    Vertebro-Vertebral Fistula Occlusion Using a Woven EndoBridgeTM-Device

    by Rasmus Holmboe Dahl, Mohammad Ghasemi-Rad, Vagn Eskesen, Susanne Christiansen Frevert, Christine Sølling, Goetz Benndorf

    Vertebro-vertebral fistulas (VVFs) are vascular lesions that may develop after trauma or spontaneously in association with connective tissue disorders. We present a rare case of a post-traumatic VVF in a young patient presenting with a painless swelling and a bruit in her left upper neck. Digital subtraction angiography showed an arteriovenous fistula between the left vertebral artery (VA) and the vertebral venous plexus with significant steal phenomenon. Endovascular therapy was performed using a Woven EndoBridgeTM (WEB)-device combined with coils that allowed preservation of the VA. The patient fully recovered from her symptoms and follow-up imaging showed stable occlusion. In conclusion, VVFs can be effectively treated using intrasaccular flow diverters such as the WEB-device, allowing for complete and stable occlusion while preserving the parent artery.


  • Open Access

    Combined cone-beam CT imaging and microsurgical dissection of cadaver specimens to study cerebral venous anatomy: a technical note

    by Markus E. Krogager, Rasmus H. Dahl, Lars Poulsgaard, Kåre Fugleholm, Tom Sehested, Ronni Mikkelsen, Jørgen Tranum-Jensen, Tiit I. Mathiesen, Goetz Benndorf

    Purpose: Cadaver dissections and X-ray based 3D angiography are considered gold standards for studying neurovascular anatomy. We sought to develop a model that utilize the combination of both these techniques to improve current tools for anatomical research, teaching and preoperative surgical planning, particularly addressing the venous system of the brain. Materials and methods: Seven ethanol-fixed human cadaveric heads and one arm were injected with a latex-barium mixture into the internal jugular veins and the brachial artery. After the ethanol-based fixation, specimens were scanned by high-resolution cone-beam CT and images were post-processed on a 3D-workstation. Subsequent, microsurgical dissections were performed by an experienced neurosurgeon and venous anatomy was compared with relevant 3D venograms. Results: Latex-barium mixtures resulted in a homogenous cast with filling of the cerebral venous structures down to 150 μm in diameter. The ethanol-based preparation of the cadaveric brains allowed for near-realistic microsurgical maneuverability during dissection. The model improves assessment of the venous system for anatomical education and hands-on surgical training. Conclusion: To our knowledge we describe the first preparation method which combines near-realistic microsurgical dissection of human heads with high-resolution 3D imaging of the cerebral venous system in the same specimens.


  • Open Access

    O-054 Backloading of guidewires create microscopic coating fragments – another source for cerebral polymer embolisms

    by R Holmboe Dahl, G Benndorf

    Background Cerebral embolism of coating fragments from endovascular devices represent a serious complication to neuroendovascular treatment that may cause ischemic infarction, intraparenchymal hemorrhage, granulomatous angiitis, and non-ischemic cerebral enhancing lesions. Although coating fragments may be created relatively often during neuroendovascular procedures, only few studies have systematically assessed mechanisms responsible for coating damage. We hypothesize that coating fragments may be created when a microguidewire is backloaded through an introducer. Materials and Methods Eight microguidewires (Asahi Chikai 200 cm, Asahi Chikai Black, Fathom™, Hybrid, Radifocus® Guide Wire GT, Synchro2®, Transend™ EX, and Traxcess™) frequently used during endovascular therapy were investigated ex vivo using their dedicated metal or plastic insertion tools to assess for coating delamination after backloading of the microguidewires. Backloading was first performed with a straight microguidewire and subsequently with moderate (15°) and severe (30°) bending of the main body of the microguidewire in front of the insertion tool. After each attempt of backloading, the introducer was flushed with deionized water onto a microscope slide that was imaged with a polarized light microscope (Axio Imager 2 Pol, Zeiss, Oberkochen, Germany). Results Microscopic fragments were observed after every attempt of microguidewire backloading regardless of manufacturer and whether the microguidewire was straight or bent. Fewest and smallest fragments were observed after backloading of straight (figure 1A) microguidewires, while bending of the main body of the guidewire increased the number and size of fragments (figure 1B). All microguidewires in this study produced filamentous and/or band-like fragments that were consistent with peeled off pieces of the microguidewire’s coating. Filamentous fragments measured 3-15 µm in width and had a length of up to 7 mm. Band-like fragments had a width of 35-115 µm and were more often created when microguidewires were bent during backloading. In addition, the smallest fragments measured 1-3 µm in diameter and were observed for all microguidewires. A few large fragments consisted either of multiple intertwined filaments or a single irregular piece. Conclusion Backloading of polymer-coated microguidewires during endovascular therapy should be minimized if possible. More stable hydrophilic coatings on microguidewires and less traumatic insertion tools are desirable. Disclosures R. Holmboe Dahl: None. G. Benndorf: None.

  • Open Access

    E-122 Stapedotomy facilitated by endovascular occlusion of a persistent stapedial artery

    by R Holmboe Dahl, S Bloch, K Hansen, G Benndorf

    Introduction The stapedial artery is an embryonic artery that transiently supplies the cranial vasculature of the human embryo. Postnatal persistence of the stapedial artery may cause conductive hearing loss and pulsatile tinnitus due to its course through the middle ear. The artery may be identified coincidentally on brain CT scans where the foramen spinosum is often absent and may be associated with other vascular variants. In clinical practice, a persistent stapedial artery (PSA) can be found in conjunction with stapes surgery for otosclerosis. We present a patient with a PSA who underwent cerebral angiography and endovascular coiling of the PSA prior to stapedotomy. To our knowledge, endovascular occlusion of a PSA has never been reported although it has been mentioned by several authors as a possible alternative option to surgical techniques. Materials and Methods A 48-year-old woman presented with left-sided conductive hearing loss and pulsatile tinnitus. The patient had previously undergone explorative tympanoplasty, which was aborted due to the PSA. Digital subtraction angiography showed a PSA arising from the cervical portion of the internal carotid artery, which coursed through the middle ear and supplied the MMA territory (figure 1A). Three small detachable coils (Target® 360 & helical (1 mm), Stryker, Kalamazoo, MI, USA) were deployed in the caroticotympanic artery 5 mm below the stapes. The position of the coils in the caroticotympanic canaliculus was confirmed by cone-beam CT (figure 1B). Results The pulsatile tinnitus improved immediately after the procedure. A reduced size of the artery was subsequently found during middle ear surgery that could be performed with only a minor perioperative bleeding. Successful stapedotomy resulted in postoperative normalization of her hearing with some minor residual tinnitus. The patient reported a non-continuous minimal residual tinnitus not affecting her much. Conclusion A PSA is a rare vascular variant and can be associated with other anomalies involving the arterial and osseous structures of the middle ear. Endovascular occlusion of a PSA is a feasible and safe procedure in patients with favorable vascular anatomy. It can decrease the size of the PSA prior to middle ear surgery and thereby minimizing the risk of peroperative bleeding and allowing for stapedotomy especially in patients with a large PSA. The exact role of endovascular occlusion for the treatment of PSA-related conductive hearing loss and pulsatile tinnitus remains to be determined. Disclosures R. Holmboe Dahl: None. S. Bloch: None. K. Hansen: None. G. Benndorf: None.