Bert Maat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bert Maat has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Deniz Başkent
Department of Otorhinolaryngology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
3 shared publications - Eleanor E. Harding
Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
3 shared publications - Etienne Gaudrain
Lyon Neuroscience Research Center, Université Claude Bernard Lyon 1, CNRS UMR5292, Inserm U1028, University of Lyon 1, Center Hospitalier Le Vinatier -Bâtiment 462-Neurocampus,95 boulevard Pinel Lyon, France
3 shared publications - Barbara Tillmann
Université Bourgogne Europe, CNRS, LEAD UMR5022, 21000, Dijon, France
2 shared publications - Pim van Dijk
Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, University of Groningen, P.O. Box 30.001, 9700 RB Groningen, The Netherlands
2 shared publications Robert L. Harris
Department of Otorhinolaryngology / Head and Neck Surgery, University Medical Center Groningen, University of Groningen
2 shared publications
Latest Publications
- Open Access
- 20 March 2025
- Published by SAGE Publications in Quarterly Journal of Experimental Psychology
- Vol. 79 (12) , 3250-3273
Vocal and musical emotion perception, voice cue discrimination, and quality of life in cochlear implant users with and without acoustic hearing
This study aims to provide a comprehensive picture of auditory emotion perception in cochlear implant (CI) users by (1) investigating emotion categorisation in both vocal (pseudo-speech) and musical domains and (2) how individual differences in residual acoustic hearing, sensitivity to voice cues (voice pitch, vocal tract length), and quality of life (QoL) might be associated with vocal emotion perception and, going a step further, also with musical emotion perception. In 28 adult CI users, with or without self-reported acoustic hearing, we showed that sensitivity (d’) scores for emotion categorisation varied largely across the participants, in line with previous research. However, within participants, the d’ scores for vocal and musical emotion categorisation were significantly correlated, indicating both similar processing of auditory emotional cues across the pseudo-speech and music domains as well as robustness of the tests. Only for musical emotion perception, emotion d’ scores were higher in implant users with residual acoustic hearing compared to no acoustic hearing. The voice pitch perception did not significantly correlate with emotion categorisation in either domain, while the vocal tract length significantly correlated in both domains. For QoL, only the sub-domain of Speech production ability, but not the overall QoL scores, correlated with vocal emotion categorisation, partially supporting previous findings. Taken together, results indicate that auditory emotion perception is challenging for some CI users, possibly a consequence of how available the emotion-related cues are via electric hearing. Improving these cues, either via rehabilitation or training, may also help auditory emotion perception in CI users.
- 20 March 2025
- Published by SAGE Publications in Quarterly Journal of Experimental Psychology
- Vol. 79 (12) , 3250-3273
Open AccessVocal and musical emotion perception, voice cue discrimination, and quality of life in cochlear implant users with and without acoustic hearing
This study aims to provide a comprehensive picture of auditory emotion perception in cochlear implant (CI) users by (1) investigating emotion categorisation in both vocal (pseudo-speech) and musical domains and (2) how individual differences in residual acoustic hearing, sensitivity to voice cues (voice pitch, vocal tract length), and quality of life (QoL) might be associated with vocal emotion perception and, going a step further, also with musical emotion perception. In 28 adult CI users, with or without self-reported acoustic hearing, we showed that sensitivity (d’) scores for emotion categorisation varied largely across the participants, in line with previous research. However, within participants, the d’ scores for vocal and musical emotion categorisation were significantly correlated, indicating both similar processing of auditory emotional cues across the pseudo-speech and music domains as well as robustness of the tests. Only for musical emotion perception, emotion d’ scores were higher in implant users with residual acoustic hearing compared to no acoustic hearing. The voice pitch perception did not significantly correlate with emotion categorisation in either domain, while the vocal tract length significantly correlated in both domains. For QoL, only the sub-domain of Speech production ability, but not the overall QoL scores, correlated with vocal emotion categorisation, partially supporting previous findings. Taken together, results indicate that auditory emotion perception is challenging for some CI users, possibly a consequence of how available the emotion-related cues are via electric hearing. Improving these cues, either via rehabilitation or training, may also help auditory emotion perception in CI users.
- Open Access
Vocal and musical emotion perception, voice cue discrimination, and quality of life in cochlear implant users with and without acoustic hearing
This study aims to provide a comprehensive picture of auditory emotion perception in cochlear implant (CI) users by (1) investigating emotion categorization in both vocal (pseudo-speech) and musical domains and (2) how individual differences in residual acoustic hearing, sensitivity to voice cues (voice pitch, vocal tract length), and quality of life (QoL) might be associated with vocal emotion perception and, going a step further, also with musical emotion perception. In 28 adult CI users, with or without self-reported acoustic hearing, we showed that sensitivity (d’) scores for emotion categorization varied largely across the participants, in line with previous research. However, within participants, the d’ scores for vocal and musical emotion categorization were significantly correlated, indicating similar processing of auditory emotional cues across the pseudo-speech and music domains and robustness of the tests. Only for musical emotion perception, emotion d’ scores were higher in implant users with residual acoustic hearing compared to no acoustic hearing. The voice pitch perception did not significantly correlate with emotion categorization in either domain, while the vocal tract length significantly correlated in both domains. For QoL, only the subdomain of Speech production ability, but not the overall QoL scores, correlated with vocal emotion categorization, partially supporting previous findings. Taken together, results indicate that auditory emotion perception is challenging for some CI users, possibly a consequence of how available the emotion-related cues are via electric hearing. Improving these cues, either via rehabilitation or training, may also help auditory emotion perception in CI users.
Open AccessVocal and musical emotion perception, voice cue discrimination, and quality of life in cochlear implant users with and without acoustic hearing
This study aims to provide a comprehensive picture of auditory emotion perception in cochlear implant (CI) users by (1) investigating emotion categorization in both vocal (pseudo-speech) and musical domains and (2) how individual differences in residual acoustic hearing, sensitivity to voice cues (voice pitch, vocal tract length), and quality of life (QoL) might be associated with vocal emotion perception and, going a step further, also with musical emotion perception. In 28 adult CI users, with or without self-reported acoustic hearing, we showed that sensitivity (d’) scores for emotion categorization varied largely across the participants, in line with previous research. However, within participants, the d’ scores for vocal and musical emotion categorization were significantly correlated, indicating similar processing of auditory emotional cues across the pseudo-speech and music domains and robustness of the tests. Only for musical emotion perception, emotion d’ scores were higher in implant users with residual acoustic hearing compared to no acoustic hearing. The voice pitch perception did not significantly correlate with emotion categorization in either domain, while the vocal tract length significantly correlated in both domains. For QoL, only the subdomain of Speech production ability, but not the overall QoL scores, correlated with vocal emotion categorization, partially supporting previous findings. Taken together, results indicate that auditory emotion perception is challenging for some CI users, possibly a consequence of how available the emotion-related cues are via electric hearing. Improving these cues, either via rehabilitation or training, may also help auditory emotion perception in CI users.
- Open Access
- 11 January 2023
- Published by SAGE Publications in Trends in Hearing
- Vol. 27
Musical Emotion Categorization with Vocoders of Varying Temporal and Spectral Content
While previous research investigating music emotion perception of cochlear implant (CI) users observed that temporal cues informing tempo largely convey emotional arousal (relaxing/stimulating), it remains unclear how other properties of the temporal content may contribute to the transmission of arousal features. Moreover, while detailed spectral information related to pitch and harmony in music — often not well perceived by CI users— reportedly conveys emotional valence (positive, negative), it remains unclear how the quality of spectral content contributes to valence perception. Therefore, the current study used vocoders to vary temporal and spectral content of music and tested music emotion categorization (joy, fear, serenity, sadness) in 23 normal-hearing participants. Vocoders were varied with two carriers (sinewave or noise; primarily modulating temporal information), and two filter orders (low or high; primarily modulating spectral information). Results indicated that emotion categorization was above-chance in vocoded excerpts but poorer than in a non-vocoded control condition. Among vocoded conditions, better temporal content (sinewave carriers) improved emotion categorization with a large effect while better spectral content (high filter order) improved it with a small effect. Arousal features were comparably transmitted in non-vocoded and vocoded conditions, indicating that lower temporal content successfully conveyed emotional arousal. Valence feature transmission steeply declined in vocoded conditions, revealing that valence perception was difficult for both lower and higher spectral content. The reliance on arousal information for emotion categorization of vocoded music suggests that efforts to refine temporal cues in the CI user signal may immediately benefit their music emotion perception.
- 11 January 2023
- Published by SAGE Publications in Trends in Hearing
- Vol. 27
Open AccessMusical Emotion Categorization with Vocoders of Varying Temporal and Spectral Content
While previous research investigating music emotion perception of cochlear implant (CI) users observed that temporal cues informing tempo largely convey emotional arousal (relaxing/stimulating), it remains unclear how other properties of the temporal content may contribute to the transmission of arousal features. Moreover, while detailed spectral information related to pitch and harmony in music — often not well perceived by CI users— reportedly conveys emotional valence (positive, negative), it remains unclear how the quality of spectral content contributes to valence perception. Therefore, the current study used vocoders to vary temporal and spectral content of music and tested music emotion categorization (joy, fear, serenity, sadness) in 23 normal-hearing participants. Vocoders were varied with two carriers (sinewave or noise; primarily modulating temporal information), and two filter orders (low or high; primarily modulating spectral information). Results indicated that emotion categorization was above-chance in vocoded excerpts but poorer than in a non-vocoded control condition. Among vocoded conditions, better temporal content (sinewave carriers) improved emotion categorization with a large effect while better spectral content (high filter order) improved it with a small effect. Arousal features were comparably transmitted in non-vocoded and vocoded conditions, indicating that lower temporal content successfully conveyed emotional arousal. Valence feature transmission steeply declined in vocoded conditions, revealing that valence perception was difficult for both lower and higher spectral content. The reliance on arousal information for emotion categorization of vocoded music suggests that efforts to refine temporal cues in the CI user signal may immediately benefit their music emotion perception.
- Open Access
An auditory brainstem implant for treatment of unilateral tinnitus: protocol for an interventional pilot study
Introduction Tinnitus may have a very severe impact on the quality of life. Unfortunately, for many patients, a satisfactory treatment modality is lacking. The auditory brainstem implant (ABI) was originally indicated for hearing restoration in patients with non-functional cochlear nerves, for example, in neurofibromatosis type II. In analogy to a cochlear implant (CI), it has been demonstrated that an ABI may reduce tinnitus as a beneficial side effect. For tinnitus treatment, an ABI may have an advantage over a CI, as cochlear implantation can harm inner ear structures due to its invasiveness, while an ABI is presumed to not damage anatomical structures. This is the first study to implant an ABI to investigate its effect on intractable tinnitus. Methods and analysis In this pilot study, 10 adults having incapacitating unilateral intractable tinnitus and ipsilateral severe hearing loss will have an ABI implanted. The ABI is switched on 6 weeks after implantation, followed by several fitting sessions aimed at finding an optimal stimulation strategy. The primary outcome will be the change in Tinnitus Functioning Index. Secondary outcomes will be tinnitus burden and quality of life (using Tinnitus Handicap Inventory and Hospital Anxiety and Depression Scale questionnaires), tinnitus characteristics (using Visual Analogue Scale, a tinnitus analysis), safety, audiometric and vestibular function. The end point is set at 1 year after implantation. Follow-up will continue until 5 years after implantation. Ethics and dissemination The protocol was reviewed and approved by the Institutional Review Board of the University Medical Centre Groningen, The Netherlands (METc 2015/479). The trial is registered at www.clinicialtrials.gov and will be updated if amendments are made. Results of this study will be disseminated in peer-reviewed journals and at scientific conferences. Trial registration number NCT02630589. Trial status Inclusion of first patient in November 2017. Data collection is in progress. Trial is open for further inclusion. The trial ends at 5 years after inclusion of the last patient.
Open AccessAn auditory brainstem implant for treatment of unilateral tinnitus: protocol for an interventional pilot study
Introduction Tinnitus may have a very severe impact on the quality of life. Unfortunately, for many patients, a satisfactory treatment modality is lacking. The auditory brainstem implant (ABI) was originally indicated for hearing restoration in patients with non-functional cochlear nerves, for example, in neurofibromatosis type II. In analogy to a cochlear implant (CI), it has been demonstrated that an ABI may reduce tinnitus as a beneficial side effect. For tinnitus treatment, an ABI may have an advantage over a CI, as cochlear implantation can harm inner ear structures due to its invasiveness, while an ABI is presumed to not damage anatomical structures. This is the first study to implant an ABI to investigate its effect on intractable tinnitus. Methods and analysis In this pilot study, 10 adults having incapacitating unilateral intractable tinnitus and ipsilateral severe hearing loss will have an ABI implanted. The ABI is switched on 6 weeks after implantation, followed by several fitting sessions aimed at finding an optimal stimulation strategy. The primary outcome will be the change in Tinnitus Functioning Index. Secondary outcomes will be tinnitus burden and quality of life (using Tinnitus Handicap Inventory and Hospital Anxiety and Depression Scale questionnaires), tinnitus characteristics (using Visual Analogue Scale, a tinnitus analysis), safety, audiometric and vestibular function. The end point is set at 1 year after implantation. Follow-up will continue until 5 years after implantation. Ethics and dissemination The protocol was reviewed and approved by the Institutional Review Board of the University Medical Centre Groningen, The Netherlands (METc 2015/479). The trial is registered at www.clinicialtrials.gov and will be updated if amendments are made. Results of this study will be disseminated in peer-reviewed journals and at scientific conferences. Trial registration number NCT02630589. Trial status Inclusion of first patient in November 2017. Data collection is in progress. Trial is open for further inclusion. The trial ends at 5 years after inclusion of the last patient.
- Open Access
- 9 November 2010
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 12 (1) , 13-28
The Effect of Static Ear Canal Pressure on Human Spontaneous Otoacoustic Emissions: Spectral Width as a Measure of the Intra-cochlear Oscillation Amplitude
Spontaneous otoacoustic emissions can be detected as peaks in the Fourier spectrum of a microphone signal recorded from the ear canal. The height, center frequency, and spectral width of SOAE peaks changed when a static pressure was applied to the ear canal. Most commonly, with either increasing or decreasing static pressure, the frequency increased, the amplitude decreased, and the width increased. These changes are believed to result from changes in the middle ear properties. Specifically, reduced middle ear transmission is assumed to attenuate the amplitude of emissions. We reconsidered this explanation by investigating the relation between peak height and width. We showed that the spectral width of SOAE peaks is approximately proportional to \( 1/\sqrt {{{\hbox{peak}}\;{\hbox{height}}}} \). This is consistent with a (Rayleigh) oscillator model in which broadening of the SOAE peak is caused by broadband intra-cochlear noise, which is assumed to be independent of static ear canal pressure. The relation between emission peak height and width implicates that the intra-cochlear oscillation amplitude attentuates relative to the intra-cochlear noise level when a static ear canal pressure is applied. Apparently, ear canal static pressure directly affects the active mechanics in the inner ear.- 9 November 2010
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 12 (1) , 13-28
Open AccessThe Effect of Static Ear Canal Pressure on Human Spontaneous Otoacoustic Emissions: Spectral Width as a Measure of the Intra-cochlear Oscillation Amplitude
Spontaneous otoacoustic emissions can be detected as peaks in the Fourier spectrum of a microphone signal recorded from the ear canal. The height, center frequency, and spectral width of SOAE peaks changed when a static pressure was applied to the ear canal. Most commonly, with either increasing or decreasing static pressure, the frequency increased, the amplitude decreased, and the width increased. These changes are believed to result from changes in the middle ear properties. Specifically, reduced middle ear transmission is assumed to attenuate the amplitude of emissions. We reconsidered this explanation by investigating the relation between peak height and width. We showed that the spectral width of SOAE peaks is approximately proportional to \( 1/\sqrt {{{\hbox{peak}}\;{\hbox{height}}}} \). This is consistent with a (Rayleigh) oscillator model in which broadening of the SOAE peak is caused by broadband intra-cochlear noise, which is assumed to be independent of static ear canal pressure. The relation between emission peak height and width implicates that the intra-cochlear oscillation amplitude attentuates relative to the intra-cochlear noise level when a static ear canal pressure is applied. Apparently, ear canal static pressure directly affects the active mechanics in the inner ear.