Conan McCaul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Conan McCaul has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
Brian P. Kavanagh
6 shared publicationsDoreen Engelberts
5 shared publications- Patrick Joseph McNamara
University of Iowa
5 shared publications A. Aslani
Department of Anesthesia, The Rotunda Hospital
3 shared publicationsMohamad Atef Radwan
Department of Anaesthesiology and Critical Care Medicine, Mater Misericordiae Hospital, Dublin, Ireland
3 shared publicationsAlik Kornecki
2 shared publications
Latest Publications
- 13 January 2026
- Published by Elsevier in Anesthesiology Clinics
- Vol. 44 (1) , 139-155
Extracorporeal Membrane Oxygenation and Airway Management
- 13 January 2026
- Published by Elsevier in Anesthesiology Clinics
- Vol. 44 (1) , 139-155
Extracorporeal Membrane Oxygenation and Airway Management
- Open Access
- 1 December 2025
- Published by AME Publishing Company in Journal of Oral and Maxillofacial Anesthesia
- Vol. 4, 25
Maintaining oxygenation during awake fibre-optic intubation—the role of high flow nasal oxygen therapy: a narrative review
Background and Objective: Awake fibre-optic intubation (AFOI) is usually performed in patients with challenging airway anatomy under sedation. Oxygen supplementation is recommended during this procedure to avoid hypoxemia. The objective of this review was to determine the optimal method of maintaining oxygenation during this method of intubation of the trachea. The review aims to fill a knowledge gap as no comprehensive assessment of the existing approaches has been carried out to date. Methods: A literature search was carried out across four major databases: PubMed, Scopus, Web of Science, and Google Scholar. Both Medical Subject Headings (MeSH) and free-text keywords were used. The search was last updated on 1st June 2025, and studies published from 1950 up to this date were considered. Eligible studies were those that reported on adult patients (≥18 years) undergoing AFOI, examined oxygenation techniques or hypoxemia as an outcome, were published in English, and included observational studies, randomised controlled trials (RCTs), case series, or surveys. Key Content and Findings: The findings are based mainly on observational studies, with some information from RCTs that compared sedation techniques or intubation equipment. Multiple methods of oxygen administration are described, including low-flow cannula, nasopharyngeal airways (NPAs), anaesthetic circuit pre-oxygenation, fibre-optic working channel oxygen, supraglottic jet ventilation (SJV), transtracheal narrow bore catheters and high-flow nasal oxygen (HFNO), which is the technique currently suggested by the Difficult Airway Society. Owing to a lack of relevant comparative clinical trials, we were unable to establish a clear superiority of any particular approach. Patient safety can be enhanced by screening for established predictors of hypoxemia, and using safe sedation practices. Conclusions: Although high-flow nasal cannula (HFNC) is the recommended method of oxygen administration, there are limited data to support this, as simpler, cheaper technologies such as low flow nasal cannula (LFNC) are adequate for many patients. The recommendation of the authors is to use risk stratification to determine the method of oxygenation and to use high flow in patients at higher risk of hypoxemia. Equally important is adequacy of topicalization and limiting sedation depth to no more than is required.
- 1 December 2025
- Published by AME Publishing Company in Journal of Oral and Maxillofacial Anesthesia
- Vol. 4, 25
Open AccessMaintaining oxygenation during awake fibre-optic intubation—the role of high flow nasal oxygen therapy: a narrative review
Background and Objective: Awake fibre-optic intubation (AFOI) is usually performed in patients with challenging airway anatomy under sedation. Oxygen supplementation is recommended during this procedure to avoid hypoxemia. The objective of this review was to determine the optimal method of maintaining oxygenation during this method of intubation of the trachea. The review aims to fill a knowledge gap as no comprehensive assessment of the existing approaches has been carried out to date. Methods: A literature search was carried out across four major databases: PubMed, Scopus, Web of Science, and Google Scholar. Both Medical Subject Headings (MeSH) and free-text keywords were used. The search was last updated on 1st June 2025, and studies published from 1950 up to this date were considered. Eligible studies were those that reported on adult patients (≥18 years) undergoing AFOI, examined oxygenation techniques or hypoxemia as an outcome, were published in English, and included observational studies, randomised controlled trials (RCTs), case series, or surveys. Key Content and Findings: The findings are based mainly on observational studies, with some information from RCTs that compared sedation techniques or intubation equipment. Multiple methods of oxygen administration are described, including low-flow cannula, nasopharyngeal airways (NPAs), anaesthetic circuit pre-oxygenation, fibre-optic working channel oxygen, supraglottic jet ventilation (SJV), transtracheal narrow bore catheters and high-flow nasal oxygen (HFNO), which is the technique currently suggested by the Difficult Airway Society. Owing to a lack of relevant comparative clinical trials, we were unable to establish a clear superiority of any particular approach. Patient safety can be enhanced by screening for established predictors of hypoxemia, and using safe sedation practices. Conclusions: Although high-flow nasal cannula (HFNC) is the recommended method of oxygen administration, there are limited data to support this, as simpler, cheaper technologies such as low flow nasal cannula (LFNC) are adequate for many patients. The recommendation of the authors is to use risk stratification to determine the method of oxygenation and to use high flow in patients at higher risk of hypoxemia. Equally important is adequacy of topicalization and limiting sedation depth to no more than is required.
- 5 September 2024
- Published by Wolters Kluwer Health in International Anesthesiology Clinics
- Vol. 62 (4) , 101-114
In the Nick of Time—Emergency Front-of-Neck Airway Access
Emergency front-of-neck access refers to all techniques that deliver oxygen into the airway lumen through the anterior neck structures and encompasses access both through the cricothyroid membrane and the tracheal wall. There has yet to be a universal agreement regarding the preferred technique. A surgical incision is currently the most common approach in prehospital and in-hospital care. This review intends to review and summarize the existing clinical, basic science, and societal guidelines for eFONA.
- 5 September 2024
- Published by Wolters Kluwer Health in International Anesthesiology Clinics
- Vol. 62 (4) , 101-114
In the Nick of Time—Emergency Front-of-Neck Airway Access
Emergency front-of-neck access refers to all techniques that deliver oxygen into the airway lumen through the anterior neck structures and encompasses access both through the cricothyroid membrane and the tracheal wall. There has yet to be a universal agreement regarding the preferred technique. A surgical incision is currently the most common approach in prehospital and in-hospital care. This review intends to review and summarize the existing clinical, basic science, and societal guidelines for eFONA.
- 30 April 2024
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 59, 104208
Total spinal anaesthesia following obstetric neuraxial blockade: a narrative review
- 30 April 2024
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 59, 104208
Total spinal anaesthesia following obstetric neuraxial blockade: a narrative review
- Open Access
- 17 March 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (5) , 1265-1273
Exhaled patient derived aerosol dispersion during awake tracheal intubation with concurrent high flow nasal therapy
Awake Tracheal Intubation (ATI) can be performed in cases where there is potential for difficult airway management. It is considered an aerosol generating procedure and is a source of concern to healthcare workers due to the risk of transmission of airborne viral infections, such as SARS–CoV-2. At present, there is a lack of data on the quantities, size distributions and spread of aerosol particles generated during such procedures. This was a volunteer observational study which took place in an operating room of a university teaching hospital. Optical particle sizers were used to provide real time aerosol characterisation during a simulated ATI performed with concurrent high-flow nasal oxygen therapy. The particle sizers were positioned at locations that represented the different locations of clinical staff in an operating room during an ATI. The greatest concentration of patient derived aerosol particles was within 0.5–1.0 m of the subject and along their midline, 2242 #/cm3. As the distance, both radial and longitudinal, from the subject increased, the concentration decreased towards ambient levels, 36.9 ± 5.1 #/cm3. Patient derived aerosol particles < 5 µm in diameter remained entrained in the exhaled aerosol plume and fell to the floor or onto the subject. Patient derived particles > 5 µm in diameter broke away from the exhaled plume and spread radially throughout the operating room. Irrespective of distance and ventilation status, full airborne protective equipment should be worn by all staff when ATI is being performed on patients with suspected viral respiratory infections.
- 17 March 2023
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (5) , 1265-1273
Open AccessExhaled patient derived aerosol dispersion during awake tracheal intubation with concurrent high flow nasal therapy
Awake Tracheal Intubation (ATI) can be performed in cases where there is potential for difficult airway management. It is considered an aerosol generating procedure and is a source of concern to healthcare workers due to the risk of transmission of airborne viral infections, such as SARS–CoV-2. At present, there is a lack of data on the quantities, size distributions and spread of aerosol particles generated during such procedures. This was a volunteer observational study which took place in an operating room of a university teaching hospital. Optical particle sizers were used to provide real time aerosol characterisation during a simulated ATI performed with concurrent high-flow nasal oxygen therapy. The particle sizers were positioned at locations that represented the different locations of clinical staff in an operating room during an ATI. The greatest concentration of patient derived aerosol particles was within 0.5–1.0 m of the subject and along their midline, 2242 #/cm3. As the distance, both radial and longitudinal, from the subject increased, the concentration decreased towards ambient levels, 36.9 ± 5.1 #/cm3. Patient derived aerosol particles < 5 µm in diameter remained entrained in the exhaled aerosol plume and fell to the floor or onto the subject. Patient derived particles > 5 µm in diameter broke away from the exhaled plume and spread radially throughout the operating room. Irrespective of distance and ventilation status, full airborne protective equipment should be worn by all staff when ATI is being performed on patients with suspected viral respiratory infections.
- 3 March 2021
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 191 (1) , 413-420
Evaluation of a novel emergency front of neck access device in a benchtop model of obesity
Background Emergency front of neck access (eFONA) is a critical step in oxygenation in cases of unrelieved airway obstruction. Multiple techniques are used in clinical practice without agreement regarding the optimal approach. We evaluated a novel device, the Cric-Guide (CG), a channelled bougie introducer that enters the airway in a single action and compared it with a scalpel-bougie-tube (SBT) technique in laboratory benchtop model. Methods Seven anaesthesiologists attempted eFONA on both obese and non-obese models using both techniques in randomized order on an excised porcine trachea with an intact larynx with variable subcutaneous tissue depth. The primary outcome was successful tracheal cannulation. Secondary outcomes included false passage rate, time and tissue injury. Results Anaesthesiologists performed 4 cricothyroidotomies on each model with each device. The CG was more successful in airway cannulation (47/56 [89.4%] vs. 33/56 [58.9%], P = 0.007). This difference was observed in the obese model only. The CG was associated with fewer false passages than the standard technique in the obese model (8/56 [14.3%] vs. 23/56 [41.1%], P = 0.006). There were no significant differences in time to completion or injury patterns between the techniques in the obese model, but the SBT was faster in the non-obese model. There was no difference in the proportion of specimens injured. Conclusion The Cric-Guide device was more successful than the standard SBT technique in airway cannulation in an obese neck model and with equivalent frequency and distribution of injury but performed equivalently in the non-obese model.
- 3 March 2021
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 191 (1) , 413-420
Evaluation of a novel emergency front of neck access device in a benchtop model of obesity
Background Emergency front of neck access (eFONA) is a critical step in oxygenation in cases of unrelieved airway obstruction. Multiple techniques are used in clinical practice without agreement regarding the optimal approach. We evaluated a novel device, the Cric-Guide (CG), a channelled bougie introducer that enters the airway in a single action and compared it with a scalpel-bougie-tube (SBT) technique in laboratory benchtop model. Methods Seven anaesthesiologists attempted eFONA on both obese and non-obese models using both techniques in randomized order on an excised porcine trachea with an intact larynx with variable subcutaneous tissue depth. The primary outcome was successful tracheal cannulation. Secondary outcomes included false passage rate, time and tissue injury. Results Anaesthesiologists performed 4 cricothyroidotomies on each model with each device. The CG was more successful in airway cannulation (47/56 [89.4%] vs. 33/56 [58.9%], P = 0.007). This difference was observed in the obese model only. The CG was associated with fewer false passages than the standard technique in the obese model (8/56 [14.3%] vs. 23/56 [41.1%], P = 0.006). There were no significant differences in time to completion or injury patterns between the techniques in the obese model, but the SBT was faster in the non-obese model. There was no difference in the proportion of specimens injured. Conclusion The Cric-Guide device was more successful than the standard SBT technique in airway cannulation in an obese neck model and with equivalent frequency and distribution of injury but performed equivalently in the non-obese model.
- 1 February 2021
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 126 (2) , e77-e78
Optical gas imaging of carbon dioxide at tracheal extubation: a novel technique for visualising exhaled breath
- 1 February 2021
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 126 (2) , e77-e78
Optical gas imaging of carbon dioxide at tracheal extubation: a novel technique for visualising exhaled breath
- 1 May 2019
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 38, 137-142
Anaesthetic management for caesarean section of a parturient with a known difficult airway and closed spinal dysraphism
- 1 May 2019
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 38, 137-142
Anaesthetic management for caesarean section of a parturient with a known difficult airway and closed spinal dysraphism