Felicia Seemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Felicia Seemann has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Dana C. Peters
Department of Radiology and Biomedical Imaging Yale University New Haven Connecticut USA
5 shared publications - Einar Heiberg
Lund University, Skåne University Hospital
5 shared publications Rajiv Ramasawmy
Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health , 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892 , USA
5 shared publications- Adrienne E. Campbell-Washburn
Cardiovascular Branch, Division of Intramural Research National Heart, Lung, and Blood Institute, National Institutes of Health Bethesda Maryland USA
4 shared publications Robert J. Lederman
Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA 20892
4 shared publications- Håkan Arheden
Clinical Physiology, Department of Clinical Sciences Lund, Skåne University Hospital, Lund University, Lund, Sweden
3 shared publications
Latest Publications
- Open Access
- 20 March 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (1) , 101883
Characterizing extravascular lung water—A dual-contrast agent extracellular volume approach by cardiovascular magnetic resonance
- 20 March 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (1) , 101883
Open AccessCharacterizing extravascular lung water—A dual-contrast agent extracellular volume approach by cardiovascular magnetic resonance
- Open Access
- 13 September 2024
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 26 (2) , 101098
Balanced steady-state free precession phase contrast at 0.55T applied to aortic flow
- 13 September 2024
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 26 (2) , 101098
Open AccessBalanced steady-state free precession phase contrast at 0.55T applied to aortic flow
- 31 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (5) , 1838-1850
Tricuspid valve flow measurement using a deep learning framework for automated valve‐tracking 2D phase contrast
Purpose: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve‐tracking 2D method for measuring flow through the dynamic tricuspid valve.Methods: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long‐axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D‐PC scans acquired in a static slice localized at the end‐systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels.Results: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve‐tracking PC net diastolic flow showed excellent correlation with SV by right‐ventricle planimetry (bias ± 1.96 SD = −0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (−1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right‐ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin‐systole. In one patient, valve‐tracking PC displayed a high‐velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography.Conclusion: Automated valve‐tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.
- 31 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (5) , 1838-1850
Tricuspid valve flow measurement using a deep learning framework for automated valve‐tracking 2D phase contrast
Purpose: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve‐tracking 2D method for measuring flow through the dynamic tricuspid valve.Methods: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long‐axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D‐PC scans acquired in a static slice localized at the end‐systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels.Results: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve‐tracking PC net diastolic flow showed excellent correlation with SV by right‐ventricle planimetry (bias ± 1.96 SD = −0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (−1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right‐ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin‐systole. In one patient, valve‐tracking PC displayed a high‐velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography.Conclusion: Automated valve‐tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.
- Open Access
- 16 January 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 2 (1) , qyae016
Non-invasive pressure–volume loops using the elastance model and CMR: a porcine validation at transient pre-loads
Pressure–volume (PV) loops have utility in the evaluation of cardiac pathophysiology but require invasive measurements. Recently, a time-varying elastance model to derive PV loops non-invasively was proposed, using left ventricular (LV) volume by cardiovascular magnetic resonance (CMR) and brachial cuff pressure as inputs. Validation was performed using CMR and pressure measurements acquired on the same day, but not simultaneously, and without varying pre-loads. This study validates the non-invasive elastance model used to estimate PV loops at varying pre-loads, compared with simultaneous measurements of invasive pressure and volume from real-time CMR, acquired concurrent to an inferior vena cava (IVC) occlusion. We performed dynamic PV loop experiments under CMR guidance in 15 pigs (n = 7 naïve, n = 8 with ischaemic cardiomyopathy). Pre-load was altered by IVC occlusion, while simultaneously acquiring invasive LV pressures and volumes from real-time CMR. Pairing pressure and volume signals yielded invasive PV loops, and model-based PV loops were derived using real-time LV volumes. Haemodynamic parameters derived from invasive and model-based PV loops were compared. Across 15 pigs, 297 PV loops were recorded. Intra-class correlation coefficient (ICC) agreement was excellent between model-based and invasive parameters: stroke work (bias = 0.007 ± 0.03 J, ICC = 0.98), potential energy (bias = 0.02 ± 0.03 J, ICC = 0.99), ventricular energy efficiency (bias = −0.7 ± 2.7%, ICC = 0.98), contractility (bias = 0.04 ± 0.1 mmHg/mL, ICC = 0.97), and ventriculoarterial coupling (bias = 0.07 ± 0.15, ICC = 0.99). All haemodynamic parameters differed between naïve and cardiomyopathy animals (P < 0.05). The invasive vs. model-based PV loop dice similarity coefficient was 0.88 ± 0.04. An elastance model–based estimation of PV loops and associated haemodynamic parameters provided accurate measurements at transient loading conditions compared with invasive PV loops. Invasive pressure–volume (PV) loops were derived from concurrent acquisitions of left ventricular (LV) pressure and real-time cardiovascular magnetic imaging (CMR), while simultaneously performing a pre-load reduction by occluding the inferior vena cava. Non-invasive PV loops were derived using a mathematical model of the time-varying elastance with LV volumes by CMR as input. Validation in naïve and ischaemic cardiomyopathy porcine models disclosed excellent agreement for the PV loop–derived haemodynamic parameters such as stroke work, potential energy, ventricular energy efficiency, contractility, and ventriculoarterial coupling. Differences in all haemodynamic parameters were found between naïve and cardiomyopathy animals.
- 16 January 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 2 (1) , qyae016
Open AccessNon-invasive pressure–volume loops using the elastance model and CMR: a porcine validation at transient pre-loads
Pressure–volume (PV) loops have utility in the evaluation of cardiac pathophysiology but require invasive measurements. Recently, a time-varying elastance model to derive PV loops non-invasively was proposed, using left ventricular (LV) volume by cardiovascular magnetic resonance (CMR) and brachial cuff pressure as inputs. Validation was performed using CMR and pressure measurements acquired on the same day, but not simultaneously, and without varying pre-loads. This study validates the non-invasive elastance model used to estimate PV loops at varying pre-loads, compared with simultaneous measurements of invasive pressure and volume from real-time CMR, acquired concurrent to an inferior vena cava (IVC) occlusion. We performed dynamic PV loop experiments under CMR guidance in 15 pigs (n = 7 naïve, n = 8 with ischaemic cardiomyopathy). Pre-load was altered by IVC occlusion, while simultaneously acquiring invasive LV pressures and volumes from real-time CMR. Pairing pressure and volume signals yielded invasive PV loops, and model-based PV loops were derived using real-time LV volumes. Haemodynamic parameters derived from invasive and model-based PV loops were compared. Across 15 pigs, 297 PV loops were recorded. Intra-class correlation coefficient (ICC) agreement was excellent between model-based and invasive parameters: stroke work (bias = 0.007 ± 0.03 J, ICC = 0.98), potential energy (bias = 0.02 ± 0.03 J, ICC = 0.99), ventricular energy efficiency (bias = −0.7 ± 2.7%, ICC = 0.98), contractility (bias = 0.04 ± 0.1 mmHg/mL, ICC = 0.97), and ventriculoarterial coupling (bias = 0.07 ± 0.15, ICC = 0.99). All haemodynamic parameters differed between naïve and cardiomyopathy animals (P < 0.05). The invasive vs. model-based PV loop dice similarity coefficient was 0.88 ± 0.04. An elastance model–based estimation of PV loops and associated haemodynamic parameters provided accurate measurements at transient loading conditions compared with invasive PV loops. Invasive pressure–volume (PV) loops were derived from concurrent acquisitions of left ventricular (LV) pressure and real-time cardiovascular magnetic imaging (CMR), while simultaneously performing a pre-load reduction by occluding the inferior vena cava. Non-invasive PV loops were derived using a mathematical model of the time-varying elastance with LV volumes by CMR as input. Validation in naïve and ischaemic cardiomyopathy porcine models disclosed excellent agreement for the PV loop–derived haemodynamic parameters such as stroke work, potential energy, ventricular energy efficiency, contractility, and ventriculoarterial coupling. Differences in all haemodynamic parameters were found between naïve and cardiomyopathy animals.
- Open Access
- 8 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1396-1413
Dynamic lung water MRI during exercise stress
Purpose: Exercise‐induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time‐resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress.Methods: The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time‐resolved images were acquired at 0.55T using a continuous 3D stack‐of‐spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding‐window reconstruction with 90‐s temporal resolution in 20‐s increments. A supine MRI‐compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified.Results: A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (−1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%).Conclusion: Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding‐window image reconstruction.
- 8 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1396-1413
Open AccessDynamic lung water MRI during exercise stress
Purpose: Exercise‐induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time‐resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress.Methods: The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time‐resolved images were acquired at 0.55T using a continuous 3D stack‐of‐spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding‐window reconstruction with 90‐s temporal resolution in 20‐s increments. A supine MRI‐compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified.Results: A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (−1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%).Conclusion: Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding‐window image reconstruction.
- Open Access
- 15 January 2023
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 25 (1) , 1-13
Dynamic pressure–volume loop analysis by simultaneous real-time cardiovascular magnetic resonance and left heart catheterization
- 15 January 2023
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 25 (1) , 1-13
Open AccessDynamic pressure–volume loop analysis by simultaneous real-time cardiovascular magnetic resonance and left heart catheterization
- 27 December 2022
- Published by Elsevier in International Journal of Cardiology
- Vol. 375, 142-143
Identifying Takotsubo syndrome without contrast agents – Is machine learning-based diagnostics the way to go?
- 27 December 2022
- Published by Elsevier in International Journal of Cardiology
- Vol. 375, 142-143
Identifying Takotsubo syndrome without contrast agents – Is machine learning-based diagnostics the way to go?
- Open Access
- 6 June 2022
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 24 (1) , 35-13
Imaging gravity-induced lung water redistribution with automated inline processing at 0.55 T cardiovascular magnetic resonance
- 6 June 2022
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 24 (1) , 35-13
Open AccessImaging gravity-induced lung water redistribution with automated inline processing at 0.55 T cardiovascular magnetic resonance
- Open Access
- 23 April 2022
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 38 (10) , 2235-2248
Atrioventricular plane displacement and regional function to predict outcome in pulmonary arterial hypertension
To investigate if left and right atrioventricular plane displacement (AVPD) or regional contributions to SV are prognostic for outcome in patients with pulmonary arterial hypertension (PAH). Seventy-one patients with PAH and 20 sex- and age-matched healthy controls underwent CMR. Myocardial borders and RV insertion points were defined at end diastole and end systole in cine short-axis stacks to compute biventricular volumes, lateral (SVlat%) and septal (SVsept%) contribution to stroke volume. Eight atrioventricular points were defined at end diastole and end systole in 2-, 3- and 4-chamber cine long-axis views for computation of AVPD and longitudinal contribution to stroke volume (SVlong%). Cut-off values for survival analysis were defined as two standard deviations above or below the mean of the controls. Outcome was defined as death or lung transplantation. Median follow-up time was 3.6 [IQR 3.7] years. Patients were 57 ± 19 years (65% women) and controls 58 ± 15 years (70% women). Biventricular AVPD, SVlong% and ejection fraction (EF) were lower and SVlat% was higher, while SVsept% was lower in PAH compared with controls. In PAH, transplantation-free survival was lower below cut-off for LV-AVPD (hazard ratio [HR] = 2.1, 95%CI 1.2–3.9, p = 0.02) and RV-AVPD (HR = 9.8, 95%CI 4.6–21.1, p = 0.005). In Cox regression analysis, lower LV-AVPD and RV-AVPD inferred lower transplantation-free survival (LV: HR = 1.16, p = 0.007; RV: HR = 1.11, p = 0.01; per mm decrease). LV-SVlong%, RV-SVlong%, LV-SVlat%, RV-SVlat%, SVsept% and LV- and RVEF did not affect outcome. Low left and right AVPD were associated with outcome in PAH, but regional contributions to stroke volume and EF were not.
- 23 April 2022
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 38 (10) , 2235-2248
Open AccessAtrioventricular plane displacement and regional function to predict outcome in pulmonary arterial hypertension
To investigate if left and right atrioventricular plane displacement (AVPD) or regional contributions to SV are prognostic for outcome in patients with pulmonary arterial hypertension (PAH). Seventy-one patients with PAH and 20 sex- and age-matched healthy controls underwent CMR. Myocardial borders and RV insertion points were defined at end diastole and end systole in cine short-axis stacks to compute biventricular volumes, lateral (SVlat%) and septal (SVsept%) contribution to stroke volume. Eight atrioventricular points were defined at end diastole and end systole in 2-, 3- and 4-chamber cine long-axis views for computation of AVPD and longitudinal contribution to stroke volume (SVlong%). Cut-off values for survival analysis were defined as two standard deviations above or below the mean of the controls. Outcome was defined as death or lung transplantation. Median follow-up time was 3.6 [IQR 3.7] years. Patients were 57 ± 19 years (65% women) and controls 58 ± 15 years (70% women). Biventricular AVPD, SVlong% and ejection fraction (EF) were lower and SVlat% was higher, while SVsept% was lower in PAH compared with controls. In PAH, transplantation-free survival was lower below cut-off for LV-AVPD (hazard ratio [HR] = 2.1, 95%CI 1.2–3.9, p = 0.02) and RV-AVPD (HR = 9.8, 95%CI 4.6–21.1, p = 0.005). In Cox regression analysis, lower LV-AVPD and RV-AVPD inferred lower transplantation-free survival (LV: HR = 1.16, p = 0.007; RV: HR = 1.11, p = 0.01; per mm decrease). LV-SVlong%, RV-SVlong%, LV-SVlat%, RV-SVlat%, SVsept% and LV- and RVEF did not affect outcome. Low left and right AVPD were associated with outcome in PAH, but regional contributions to stroke volume and EF were not.
- 5 April 2022
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 15 (6) , e011686
Transcatheter Myotomy to Relieve Left Ventricular Outflow Tract Obstruction: The Septal Scoring Along the Midline Endocardium Procedure in Animals
Background: Left ventricular outflow tract obstruction complicates hypertrophic cardiomyopathy and transcatheter mitral valve replacement. Septal reduction therapies including surgical myectomy and alcohol septal ablation are limited by surgical morbidity or coronary anatomy and high pacemaker rates, respectively. We developed a novel transcatheter procedure, mimicking surgical myotomy, called Septal Scoring Along the Midline Endocardium (SESAME). Methods: SESAME was performed in 5 naive pigs and 5 pigs with percutaneous aortic banding–induced left ventricular hypertrophy. Fluoroscopy and intracardiac echocardiography guided the procedures. Coronary guiding catheters and guidewires were used to mechanically enter the basal interventricular septum. Imparting a tip bend to the guidewire enabled intramyocardial navigation with multiple df . The guidewire trajectory determined the geometry of SESAME myotomy. The myocardium was lacerated using transcatheter electrosurgery. Cardiac function and tissue characteristics were assessed by cardiac magnetic resonance at baseline, postprocedure, and at 7- or 30-day follow-up. Results: SESAME myotomy along the intended trajectory was achieved in all animals. The myocardium splayed after laceration, increasing left ventricular outflow tract area (753 to 854 mm 2 , P =0.008). Two naive pigs developed ventricular septal defects due to excessively deep lacerations in thin baseline septa. No hypertrophy model pig, with increased septal thickness and left ventricular mass compared with naive pigs, developed ventricular septal defects. One animal developed left axis deviation on ECG but no higher conduction block was seen in any animal. Coronary artery branches were intact on angiography with no infarction on cardiac magnetic resonance late gadolinium imaging. Cardiac magnetic resonance chamber volumes, function, flow, and global strain were preserved. No myocardial edema was evident on cardiac magnetic resonance T1 mapping. Conclusions: This preclinical study demonstrated feasibility of SESAME, a novel transcatheter myotomy to relieve left ventricular outflow tract obstruction. This percutaneous procedure using available devices, with a safe surgical precedent, is readily translatable into patients.
- 5 April 2022
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 15 (6) , e011686
Transcatheter Myotomy to Relieve Left Ventricular Outflow Tract Obstruction: The Septal Scoring Along the Midline Endocardium Procedure in Animals
Background: Left ventricular outflow tract obstruction complicates hypertrophic cardiomyopathy and transcatheter mitral valve replacement. Septal reduction therapies including surgical myectomy and alcohol septal ablation are limited by surgical morbidity or coronary anatomy and high pacemaker rates, respectively. We developed a novel transcatheter procedure, mimicking surgical myotomy, called Septal Scoring Along the Midline Endocardium (SESAME). Methods: SESAME was performed in 5 naive pigs and 5 pigs with percutaneous aortic banding–induced left ventricular hypertrophy. Fluoroscopy and intracardiac echocardiography guided the procedures. Coronary guiding catheters and guidewires were used to mechanically enter the basal interventricular septum. Imparting a tip bend to the guidewire enabled intramyocardial navigation with multiple df . The guidewire trajectory determined the geometry of SESAME myotomy. The myocardium was lacerated using transcatheter electrosurgery. Cardiac function and tissue characteristics were assessed by cardiac magnetic resonance at baseline, postprocedure, and at 7- or 30-day follow-up. Results: SESAME myotomy along the intended trajectory was achieved in all animals. The myocardium splayed after laceration, increasing left ventricular outflow tract area (753 to 854 mm 2 , P =0.008). Two naive pigs developed ventricular septal defects due to excessively deep lacerations in thin baseline septa. No hypertrophy model pig, with increased septal thickness and left ventricular mass compared with naive pigs, developed ventricular septal defects. One animal developed left axis deviation on ECG but no higher conduction block was seen in any animal. Coronary artery branches were intact on angiography with no infarction on cardiac magnetic resonance late gadolinium imaging. Cardiac magnetic resonance chamber volumes, function, flow, and global strain were preserved. No myocardial edema was evident on cardiac magnetic resonance T1 mapping. Conclusions: This preclinical study demonstrated feasibility of SESAME, a novel transcatheter myotomy to relieve left ventricular outflow tract obstruction. This percutaneous procedure using available devices, with a safe surgical precedent, is readily translatable into patients.