Richard D. Branson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard D. Branson has a total of 247 co-authors. Here are the top co-authors by number of shared publications:
Dario Rodriquez
13 shared publicationsJay A Johannigman
Division of Trauma and Critical Care, Department of Surgery, University of Cincinnati, Cincinnati, Ohio
6 shared publicationsJay A. Johannigman
6 shared publications- Thomas C. Blakeman
Mr. Blakeman, Ms. Schuster, Drs. Gilday, Goodman, and Mr. Branson are affiliated with University of Cincinnati, Cincinnati, Ohio, USA
4 shared publications Bryce Rh Robinson
Division of Trauma and Critical Care, Department of Surgery, University of Cincinnati, Cincinnati, Ohio
3 shared publicationsDina Gomaa
3 shared publications
Latest Publications
- 1 July 2026
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 191 (Supplement) , 90-96
Development and Evaluation of a System to Ventilate 2 Patients With a Single Ventilator
Introduction: Concerns over ventilator shortages during COVID-19 led to a number of potential solutions including using one ventilator for multiple patients. Large scale peer to peer military operations could create similar shortages. We developed and tested a device to allow 2 patients to be ventilated with a single, currently deployed ventilator. Materials and Methods: Limitations of previous designs were reviewed and design requirements detailed. An accessory device capable of splitting gas flow to 2 patients was created with separate settings for peak inspiratory pressure (PIP) and positive-end expiratory pressure (PEEP). Monitoring of airway pressures and volumes delivered to each patient were also provided along with high and low alarms. Respiratory rate, inspiratory time, inspired oxygen concentration, and rise time settings were shared and identical for each simulated patient. All breaths were pressure control (PC) breaths. Bench testing on a test lung capable of separate adjustments for compliance and resistance was accomplished across the operational range. Airway pressures and volumes delivered to each lung were continuously measured using a flow and pressure monitor and recorded for analysis. Results: The device provided individualized setting of PIP and PEEP for each patient across the ventilator’s range to account for variations in lung mechanics and ventilatory requirements. The delivered VT to patient “B” was within 10% of the target in all conditions tested. The delivered VT to patient “A” was within 10% of the target in 21 of 22 conditions tested and within 15% in all conditions. Ti was the most important shared setting with respect to delivering the target VT to either patient. Disconnection of either patient resulted in similar reductions to VT in the companion patient, while obstruction and suctioning caused markedly different effects on the VT, PIP, and PEEP delivery to the companion patient. Conclusions: An accessory to a deployed ventilator allowed for independent delivery of PIP, tidal volume and PEEP across a clinically relevant range of values in the face of large differences in lung compliance and resistance between simulated patients. The complexity of the system provides monitoring and overcomes previously identified limitations. However, implementation of such a system is limited by regulatory requirements and training concerns.
- 1 July 2026
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 191 (Supplement) , 90-96
Development and Evaluation of a System to Ventilate 2 Patients With a Single Ventilator
Introduction: Concerns over ventilator shortages during COVID-19 led to a number of potential solutions including using one ventilator for multiple patients. Large scale peer to peer military operations could create similar shortages. We developed and tested a device to allow 2 patients to be ventilated with a single, currently deployed ventilator. Materials and Methods: Limitations of previous designs were reviewed and design requirements detailed. An accessory device capable of splitting gas flow to 2 patients was created with separate settings for peak inspiratory pressure (PIP) and positive-end expiratory pressure (PEEP). Monitoring of airway pressures and volumes delivered to each patient were also provided along with high and low alarms. Respiratory rate, inspiratory time, inspired oxygen concentration, and rise time settings were shared and identical for each simulated patient. All breaths were pressure control (PC) breaths. Bench testing on a test lung capable of separate adjustments for compliance and resistance was accomplished across the operational range. Airway pressures and volumes delivered to each lung were continuously measured using a flow and pressure monitor and recorded for analysis. Results: The device provided individualized setting of PIP and PEEP for each patient across the ventilator’s range to account for variations in lung mechanics and ventilatory requirements. The delivered VT to patient “B” was within 10% of the target in all conditions tested. The delivered VT to patient “A” was within 10% of the target in 21 of 22 conditions tested and within 15% in all conditions. Ti was the most important shared setting with respect to delivering the target VT to either patient. Disconnection of either patient resulted in similar reductions to VT in the companion patient, while obstruction and suctioning caused markedly different effects on the VT, PIP, and PEEP delivery to the companion patient. Conclusions: An accessory to a deployed ventilator allowed for independent delivery of PIP, tidal volume and PEEP across a clinically relevant range of values in the face of large differences in lung compliance and resistance between simulated patients. The complexity of the system provides monitoring and overcomes previously identified limitations. However, implementation of such a system is limited by regulatory requirements and training concerns.
- 17 June 2026
- Published by SAGE Publications in Respiratory Care
- Vol. 71 (8) , 859-871
Patient-Ventilator Interaction: Timing Discordance in Invasive Ventilation
Mechanical ventilation goals include restoration of gas exchange, lung protection, and patient comfort. Improving patient comfort through synchronous patient-ventilator interaction represents a common clinical challenge in the management of these patients. Patient-ventilator discordance describes a mismatch between the patient’s intrinsic respiratory timing and effort with the ventilatory support provided by the ventilator. Achieving concordance requires an understanding of physiologic principles related to the control of breathing, expertise in recognition of discordance using the pressure and flow waveforms, and an in-depth knowledge of ventilator operation. Discordance is a common occurrence in ventilated patients, and over the past two decades, the recognition of patient-ventilator discordance has improved with education, simulation, and advances in instrumentation. Despite these advances, the impact of patient-ventilator discordance remains controversial. Growing evidence suggests patient-ventilator discordance is associated with adverse outcomes including mortality, increased sedation requirements, and duration of mechanical ventilation, although a cause-and-effect relationship has not been clearly demonstrated. Discordance may simply be a marker of the severity of illness. However, the impact of discordance varies based on the type and timing of discordance, lung mechanics, and the magnitude of patient effort. Some types of discordance may have positive effects. This article aims to explore the pathophysiology and identification of patient-ventilator discordance related to timing.
- 17 June 2026
- Published by SAGE Publications in Respiratory Care
- Vol. 71 (8) , 859-871
Patient-Ventilator Interaction: Timing Discordance in Invasive Ventilation
Mechanical ventilation goals include restoration of gas exchange, lung protection, and patient comfort. Improving patient comfort through synchronous patient-ventilator interaction represents a common clinical challenge in the management of these patients. Patient-ventilator discordance describes a mismatch between the patient’s intrinsic respiratory timing and effort with the ventilatory support provided by the ventilator. Achieving concordance requires an understanding of physiologic principles related to the control of breathing, expertise in recognition of discordance using the pressure and flow waveforms, and an in-depth knowledge of ventilator operation. Discordance is a common occurrence in ventilated patients, and over the past two decades, the recognition of patient-ventilator discordance has improved with education, simulation, and advances in instrumentation. Despite these advances, the impact of patient-ventilator discordance remains controversial. Growing evidence suggests patient-ventilator discordance is associated with adverse outcomes including mortality, increased sedation requirements, and duration of mechanical ventilation, although a cause-and-effect relationship has not been clearly demonstrated. Discordance may simply be a marker of the severity of illness. However, the impact of discordance varies based on the type and timing of discordance, lung mechanics, and the magnitude of patient effort. Some types of discordance may have positive effects. This article aims to explore the pathophysiology and identification of patient-ventilator discordance related to timing.
- 18 May 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (5) , 055016
Mathematical modeling of the respiratory system in swine with acute respiratory distress syndrome
Objective. The objective of this study is to develop a low-order mathematical model of respiratory gas exchange for design and evaluation of physiological closed-loop controlled (PCLC) mechanical ventilation and oxygenation systems, particularly under acute respiratory distress syndrome (ARDS) conditions. Approach. Experimental data from 11 swine subjects undergoing ARDS followed by hemorrhage were used to derive the mathematical model. The animals were ventilated using a PCLC system that regulated inspired oxygen fraction (FiO 2 ), positive end-expiratory pressure (PEEP), and other ventilation parameters. The mathematical model takes metabolic carbon dioxide production rate ( V ˙ CO 2 ), FiO 2 , and PEEP as inputs and outputs end-tidal CO 2 pressure (PetCO 2 ), arterial oxygen pressure (PaO 2 ), and oxygen saturation (SaO 2 ). Main results. The mathematical model accurately reproduced observed gas exchange dynamics in ARDS conditions, effectively capturing O 2 and CO 2 behavior in response to the controlled ventilation parameters. Significance. The present study focuses on mathematical model development and calibration using experimental data. The current results support its utility in simulating respiratory gas exchange under lung injury conditions. This low-order mathematical model may offer a promising tool for evaluating and designing PCLC mechanical ventilation and oxygenation, with potential applications in controller development and its preclinical testing.
- 18 May 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (5) , 055016
Mathematical modeling of the respiratory system in swine with acute respiratory distress syndrome
Objective. The objective of this study is to develop a low-order mathematical model of respiratory gas exchange for design and evaluation of physiological closed-loop controlled (PCLC) mechanical ventilation and oxygenation systems, particularly under acute respiratory distress syndrome (ARDS) conditions. Approach. Experimental data from 11 swine subjects undergoing ARDS followed by hemorrhage were used to derive the mathematical model. The animals were ventilated using a PCLC system that regulated inspired oxygen fraction (FiO 2 ), positive end-expiratory pressure (PEEP), and other ventilation parameters. The mathematical model takes metabolic carbon dioxide production rate ( V ˙ CO 2 ), FiO 2 , and PEEP as inputs and outputs end-tidal CO 2 pressure (PetCO 2 ), arterial oxygen pressure (PaO 2 ), and oxygen saturation (SaO 2 ). Main results. The mathematical model accurately reproduced observed gas exchange dynamics in ARDS conditions, effectively capturing O 2 and CO 2 behavior in response to the controlled ventilation parameters. Significance. The present study focuses on mathematical model development and calibration using experimental data. The current results support its utility in simulating respiratory gas exchange under lung injury conditions. This low-order mathematical model may offer a promising tool for evaluating and designing PCLC mechanical ventilation and oxygenation, with potential applications in controller development and its preclinical testing.
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 101 (4) , 673-681
Automated control of inspired oxygen in mechanically ventilated trauma and acute care surgery patients: A randomized controlled trial
BACKGROUND: Automated physiologic closed-loop control (PCLC) of inspired oxygen fraction (FIO 2 ) may improve oxygen titration while reducing clinician workload. We conducted a randomized noninferiority trial comparing PCLC with protocolized manual control (MC) in mechanically ventilated trauma and acute care surgery patients. METHODS: In this randomized, controlled, multicenter trial, adult mechanically ventilated patients were randomized to PCLC or MC FIO 2 titration targeting arterial oxygen saturation (SpO 2 ) of 94%±2%. The primary effectiveness outcome was the percentage of time SpO 2 remained within the target range. The primary safety outcome was hypoxemia (SpO 2 2 target range was 36.8% (IQR, 22.1–49.6) with MC and 30.1% (IQR, 18.4–44.7) with PCLC, meeting criteria for noninferiority [the mean±SD of the relative duration on the transformed scale was 0.53 (0.37) and 0.61 (0.36). The mean difference between the transformed data was −0.08 with a one-sided lower 97.5% CL of −0.18. Comparing this lower 95% CL with the prespecified noninferiority margin (NM) of −0.35, this difference lay within the NM. Hypoxemia occurred in fewer patients assigned to PCLC compared with MC (22% vs. 38%, p =0.04). PCLC was associated with lower FIO 2 exposure, more frequent automated adjustments, and fewer manual FIO 2 adjustments. CONCLUSIONS: In mechanically ventilated trauma and acute care surgery patients, PCLC of FIO 2 was noninferior to protocolized MC for maintaining target oxygen saturation. PCLC was associated with fewer hypoxemic events, reduced oxygen usage, and more frequent automated FIO 2 changes. ( J Trauma Acute Care Surg . 2026;000:000–000. Copyright © 2026 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Association for the Surgery of Trauma.) LEVEL OF EVIDENCE: Randomized Controlled Trial with single blinding; Level II.
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Trauma and Acute Care Surgery
- Vol. 101 (4) , 673-681
Automated control of inspired oxygen in mechanically ventilated trauma and acute care surgery patients: A randomized controlled trial
BACKGROUND: Automated physiologic closed-loop control (PCLC) of inspired oxygen fraction (FIO 2 ) may improve oxygen titration while reducing clinician workload. We conducted a randomized noninferiority trial comparing PCLC with protocolized manual control (MC) in mechanically ventilated trauma and acute care surgery patients. METHODS: In this randomized, controlled, multicenter trial, adult mechanically ventilated patients were randomized to PCLC or MC FIO 2 titration targeting arterial oxygen saturation (SpO 2 ) of 94%±2%. The primary effectiveness outcome was the percentage of time SpO 2 remained within the target range. The primary safety outcome was hypoxemia (SpO 2 2 target range was 36.8% (IQR, 22.1–49.6) with MC and 30.1% (IQR, 18.4–44.7) with PCLC, meeting criteria for noninferiority [the mean±SD of the relative duration on the transformed scale was 0.53 (0.37) and 0.61 (0.36). The mean difference between the transformed data was −0.08 with a one-sided lower 97.5% CL of −0.18. Comparing this lower 95% CL with the prespecified noninferiority margin (NM) of −0.35, this difference lay within the NM. Hypoxemia occurred in fewer patients assigned to PCLC compared with MC (22% vs. 38%, p =0.04). PCLC was associated with lower FIO 2 exposure, more frequent automated adjustments, and fewer manual FIO 2 adjustments. CONCLUSIONS: In mechanically ventilated trauma and acute care surgery patients, PCLC of FIO 2 was noninferior to protocolized MC for maintaining target oxygen saturation. PCLC was associated with fewer hypoxemic events, reduced oxygen usage, and more frequent automated FIO 2 changes. ( J Trauma Acute Care Surg . 2026;000:000–000. Copyright © 2026 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Association for the Surgery of Trauma.) LEVEL OF EVIDENCE: Randomized Controlled Trial with single blinding; Level II.
- Open Access
- 20 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 195, 110505
Virtual patient model for evaluating automated inspired oxygen control
- 20 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 195, 110505
Open AccessVirtual patient model for evaluating automated inspired oxygen control
- 15 July 2024
- Published by Wiley in Respirology
- Vol. 29 (9) , 741-742
Home oxygen guidelines: We do not know enough about LTOT
- 15 July 2024
- Published by Wiley in Respirology
- Vol. 29 (9) , 741-742
Home oxygen guidelines: We do not know enough about LTOT
- Open Access
- 1 June 2024
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 209 (11) , 1301-1303
U.S. Food and Drug Administration Strategy to Evaluate Pulse Oximeters: The Same Cause Will Produce the Same Effects
- 1 June 2024
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 209 (11) , 1301-1303
Open AccessU.S. Food and Drug Administration Strategy to Evaluate Pulse Oximeters: The Same Cause Will Produce the Same Effects
- 24 January 2024
- Published by SAGE Publications in Respiratory Care
- Vol. 69 (2) , 275-279
Sustainability in Respiratory Therapy: Revisiting Reusables
- 24 January 2024
- Published by SAGE Publications in Respiratory Care
- Vol. 69 (2) , 275-279
Sustainability in Respiratory Therapy: Revisiting Reusables