José Fernando Diniz Chubaci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
José Fernando Diniz Chubaci has a total of 204 co-authors. Here are the top co-authors by number of shared publications:
S. Watanabe
20 shared publicationsM. Matsuoka
Instituto de Fisica, Universidade de São Paulo, Brasil
9 shared publications- Nilo Francisco Cano
Universidade Federal de São Paulo, Instituto do Mar, Santos, SP, Brazil
9 shared publications S Watanabe
9 shared publicationsShigueo Watanabe
8 shared publicationsK. Ogata
Nissin Electric Company, Ltd. , 47, Umezu-Takase-cho, Ukyo-ku, Kyota 615-8686, Japan
6 shared publications
Latest Publications
- 19 July 2024
- Published by Elsevier in Quaternary International
- Vol. 707, 38-49
Quartz OSL dating of ancient ceramics fragments from the Churajon archaeological complex in Arequipa, Peru
- 19 July 2024
- Published by Elsevier in Quaternary International
- Vol. 707, 38-49
Quartz OSL dating of ancient ceramics fragments from the Churajon archaeological complex in Arequipa, Peru
- Open Access
- 8 March 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (10)
Driven electron g-factor anisotropy in layered III–V semiconductors: Interfacing, tunnel coupling, and structure inversion asymmetry effects
A key piece for spintronic applications, the so-called electron g-factor engineering is still predominantly based on the semiconductor bulk g factor and its dependence on the bandgap energy. In nanostructures, however, the mesoscopic confinement introduces exclusive anisotropies, transforming scalar g factors into tensors, enabling different renormalization mechanisms as routes for fine-tuning the electron g factor. These questions we address in this comparative theoretical analysis between the obtained electron g-factor (tensor) anisotropies for realistic InAs|AlSb- and In0.53Ga0.47As|InP-based multilayers. The electron g-factor anisotropy, i.e., the difference between g factors for magnetic fields parallel and perpendicular to the interfaces, is analytically calculated via perturbation theory using the envelope-function approach based on the eight-band Kane model. Effects from bulk, interfacing, tunnel coupling, and structure inversion asymmetry are systematically introduced within a transparent comparative view; differences between obtained anisotropies, such as in the magnitude, sign, and other fine details, are analyzed in terms of the heterostructure parameters, mapped over different confining and tunnel-coupling regimes without requiring elaborated numerical computations.
- 8 March 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (10)
Open AccessDriven electron g-factor anisotropy in layered III–V semiconductors: Interfacing, tunnel coupling, and structure inversion asymmetry effects
A key piece for spintronic applications, the so-called electron g-factor engineering is still predominantly based on the semiconductor bulk g factor and its dependence on the bandgap energy. In nanostructures, however, the mesoscopic confinement introduces exclusive anisotropies, transforming scalar g factors into tensors, enabling different renormalization mechanisms as routes for fine-tuning the electron g factor. These questions we address in this comparative theoretical analysis between the obtained electron g-factor (tensor) anisotropies for realistic InAs|AlSb- and In0.53Ga0.47As|InP-based multilayers. The electron g-factor anisotropy, i.e., the difference between g factors for magnetic fields parallel and perpendicular to the interfaces, is analytically calculated via perturbation theory using the envelope-function approach based on the eight-band Kane model. Effects from bulk, interfacing, tunnel coupling, and structure inversion asymmetry are systematically introduced within a transparent comparative view; differences between obtained anisotropies, such as in the magnitude, sign, and other fine details, are analyzed in terms of the heterostructure parameters, mapped over different confining and tunnel-coupling regimes without requiring elaborated numerical computations.
- Open Access
- 4 December 2022
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 10 (3B)
Nuclear and non-nuclear analytical techniques applied to pre-colonial archaeological ceramics from the upper Madeira River/Brazil (940 to 760 B.P)
This article presents the results of applying three archaeometric techniques in archaeological ceramics from the upper river Madeira region in Amazonia. The first consists of the nuclear technique, neutron activation analysis (INAA), to identify the trace elements of the clay sources used in the production of the vessels. The second, non-nuclear X-ray diffraction (XRD), was used to characterise the mineral phases of each clay source. The third technique, electron paramagnetic resonance spectroscopy (EPR), estimated burning temperature related to the production stage of the artefacts. This approach made it possible to understand technological choices linked to selecting specific clay sources. The results suggest that different indigenous groups that inhabited the region between 940 and 760 B.P selected three clay sources to produce their vessels.
- 4 December 2022
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 10 (3B)
Open AccessNuclear and non-nuclear analytical techniques applied to pre-colonial archaeological ceramics from the upper Madeira River/Brazil (940 to 760 B.P)
This article presents the results of applying three archaeometric techniques in archaeological ceramics from the upper river Madeira region in Amazonia. The first consists of the nuclear technique, neutron activation analysis (INAA), to identify the trace elements of the clay sources used in the production of the vessels. The second, non-nuclear X-ray diffraction (XRD), was used to characterise the mineral phases of each clay source. The third technique, electron paramagnetic resonance spectroscopy (EPR), estimated burning temperature related to the production stage of the artefacts. This approach made it possible to understand technological choices linked to selecting specific clay sources. The results suggest that different indigenous groups that inhabited the region between 940 and 760 B.P selected three clay sources to produce their vessels.
- 1 December 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 177
Study of thermoluminescence of green quartz pellets for low dose dosimetry
- 1 December 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 177
Study of thermoluminescence of green quartz pellets for low dose dosimetry
- 1 July 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 172
Calculated and experimental response of calcium silicate polycrystalline to high and very-high neutron doses
- 1 July 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 172
Calculated and experimental response of calcium silicate polycrystalline to high and very-high neutron doses
- Open Access
- 21 February 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 174, 01012
Characterization of multilayer Thick-GEM geometries as10B converters aiming thermal neutron detection
Boron-based thermal neutron detectors have recently regained some attention from the instrumentation community as a strong alternative to helium-3 detectors. From the existing concepts exploiting boron layers in position sensitive detectors, the Cascade [1] is the one that takes full advantage of the 2D capabilities of gaseous detectors, with the position resolution not limited by the architecture of the detector. In this work, a proposal for the Cascade detector, based on Thick-GEMs is presented, together with some preliminary studies of the suitable pitch that optimizes the neutron conversion efficiency, while keeping the collection efficiency intact. The characterization of Thick-GEM prototypes produced in Brazil with hole pitch from 0.75 to 3 mm shows that these devices already present a stable performance at low gains, also resulting in fair energy resolution, when cascaded with a standard KaptonTM50 µm GEM. Results of the first attempts of boron film depositions with Ion Beam Assisted Deposition and characterization by Ion Beam Analysis are also presented.
- 21 February 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 174, 01012
Open AccessCharacterization of multilayer Thick-GEM geometries as10B converters aiming thermal neutron detection
Boron-based thermal neutron detectors have recently regained some attention from the instrumentation community as a strong alternative to helium-3 detectors. From the existing concepts exploiting boron layers in position sensitive detectors, the Cascade [1] is the one that takes full advantage of the 2D capabilities of gaseous detectors, with the position resolution not limited by the architecture of the detector. In this work, a proposal for the Cascade detector, based on Thick-GEMs is presented, together with some preliminary studies of the suitable pitch that optimizes the neutron conversion efficiency, while keeping the collection efficiency intact. The characterization of Thick-GEM prototypes produced in Brazil with hole pitch from 0.75 to 3 mm shows that these devices already present a stable performance at low gains, also resulting in fair energy resolution, when cascaded with a standard KaptonTM50 µm GEM. Results of the first attempts of boron film depositions with Ion Beam Assisted Deposition and characterization by Ion Beam Analysis are also presented.
- 1 January 2018
- Published by Optica Publishing Group
- p. Tu4A.41
Study of InN thin film for pulse oximeter application
During the last few years the interest in indium nitride (InN) semiconductor has been remarkable because this material is a small bandgap semiconductor and could be used for infrared applications and as an IR sensor. The objective of this study is the development of pulse oximeter sensor based in InN thin film deposited by RF magnetron sputtering. A Software was produced in Labview. Its function is to reproduce the results from pulse oximeter. The data are obtained through microcontroller arduino. LEDs with 850 nm and 632 nm were used in the measurement; oxy/deoxyhemoglobin ratio can be calculated from the ratio of the absorption of red and infrared light. An analysis of spectral response was performed.
- 1 January 2018
- Published by Optica Publishing Group
- p. Tu4A.41
Study of InN thin film for pulse oximeter application
During the last few years the interest in indium nitride (InN) semiconductor has been remarkable because this material is a small bandgap semiconductor and could be used for infrared applications and as an IR sensor. The objective of this study is the development of pulse oximeter sensor based in InN thin film deposited by RF magnetron sputtering. A Software was produced in Labview. Its function is to reproduce the results from pulse oximeter. The data are obtained through microcontroller arduino. LEDs with 850 nm and 632 nm were used in the measurement; oxy/deoxyhemoglobin ratio can be calculated from the ratio of the absorption of red and infrared light. An analysis of spectral response was performed.
- 2 September 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 46 (1) , 451-457
Studies of Radiation-Induced Defects in Li2SiO3:Sm Phosphor Material
- 2 September 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 46 (1) , 451-457
Studies of Radiation-Induced Defects in Li2SiO3:Sm Phosphor Material