Melina-Maria Zempila
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Melina-Maria Zempila has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Alkiviadis Bais
Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
13 shared publications - Andreas Kazantzidis
University of Patras, Greece
6 shared publications - Ilias Fountoulakis
Research Centre for Atmospheric Physics and Climatology, Academy of Athens, 106 79 Athens, Greece
5 shared publications - Michael Taylor
Climatic Research Unit, School of Environmental Sciences, University of East Anglia, Norwich, NR4 7TJ, United Kingdom
5 shared publications - Stelios Kazadzis
Physicalisch Meteorologisches Observatorium, World Radiation Center, Davos, 7260, Switzerland
5 shared publications - Maria-Elissavet Koukouli
Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki, Thessaloniki, Greece
4 shared publications
Latest Publications
- Open Access
- 10 March 2020
- Published by Copernicus GmbH
Hyper-Spectral Imaging for Earth Observation Applications
In this study, we present a hyper-spectral imaging (HSI) system that focuses on the spectral window 470-970 nm and meets the demands of static sampling and remote sensing when mounted on an Unmanned Aerial System (UAS). The system comprises two HS cameras, a compact industrial PC and a battery pack. It has a total weight of <1.8kg, including the bracket for mounting to an active DJI Ronin gimbal. A labview interface was also developed to collect, process and analyse the images from the two HS cameras. The software has the ability to set the parameters for the cameras’ exposure times and capture frequency, while it can provide the digital counts at a single point of the image or the averaged counts over a rectangular area of the image. For the purposes of aerial applications, the program provides the ability of delayed start and sequentially image capture. For the calibration of the raw HS images, an offline workflow is developed to derive absolute reflectance values. The processing chain includes dark and vignetting correction, spectral response characterization, digital number to reflectance conversion and hyperspectral data cube reconstruction. The system has been already deployed in several in house studies: detection of dothistroma in Scots pine needles, starch detection in apples and bananas, and avocados maturity indication, while aerial imagery was also acquired during field campaigns in the UK and China aiming to create a tree species distribution map and to early identify tree health issues. The development of the system is dynamic as technology is moving forward and the demand for light-weighted multi-sensor UAS surveys is increased during the last decade. Furthermore, the calibration processes and data analysis techniques are constantly updated to meet international requirements and push the accuracy of the products to the highest standards.
- 10 March 2020
- Published by Copernicus GmbH
Open AccessHyper-Spectral Imaging for Earth Observation Applications
In this study, we present a hyper-spectral imaging (HSI) system that focuses on the spectral window 470-970 nm and meets the demands of static sampling and remote sensing when mounted on an Unmanned Aerial System (UAS). The system comprises two HS cameras, a compact industrial PC and a battery pack. It has a total weight of <1.8kg, including the bracket for mounting to an active DJI Ronin gimbal. A labview interface was also developed to collect, process and analyse the images from the two HS cameras. The software has the ability to set the parameters for the cameras’ exposure times and capture frequency, while it can provide the digital counts at a single point of the image or the averaged counts over a rectangular area of the image. For the purposes of aerial applications, the program provides the ability of delayed start and sequentially image capture. For the calibration of the raw HS images, an offline workflow is developed to derive absolute reflectance values. The processing chain includes dark and vignetting correction, spectral response characterization, digital number to reflectance conversion and hyperspectral data cube reconstruction. The system has been already deployed in several in house studies: detection of dothistroma in Scots pine needles, starch detection in apples and bananas, and avocados maturity indication, while aerial imagery was also acquired during field campaigns in the UK and China aiming to create a tree species distribution map and to early identify tree health issues. The development of the system is dynamic as technology is moving forward and the demand for light-weighted multi-sensor UAS surveys is increased during the last decade. Furthermore, the calibration processes and data analysis techniques are constantly updated to meet international requirements and push the accuracy of the products to the highest standards.
- 1 June 2018
- Published by Elsevier in Atmospheric Environment
- Vol. 183, 106-121
Validation of OMI erythemal doses with multi-sensor ground-based measurements in Thessaloniki, Greece
- 1 June 2018
- Published by Elsevier in Atmospheric Environment
- Vol. 183, 106-121
Validation of OMI erythemal doses with multi-sensor ground-based measurements in Thessaloniki, Greece
- 1 July 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 590-591, 92-106
NILU-UV multi-filter radiometer total ozone columns: Comparison with satellite observations over Thessaloniki, Greece
- 1 July 2017
- Published by Elsevier in Science of The Total Environment
- Vol. 590-591, 92-106
NILU-UV multi-filter radiometer total ozone columns: Comparison with satellite observations over Thessaloniki, Greece
- Open Access
- 16 June 2017
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 17 (11) , 7157-7174
TEMIS UV product validation using NILU-UV ground-based measurements in Thessaloniki, Greece
This study aims to cross-validate ground-based and satellite-based models of three photobiological UV effective dose products: the Commission Internationale de l'Éclairage (CIE) erythemal UV, the production of vitamin D in the skin, and DNA damage, using high-temporal-resolution surface-based measurements of solar UV spectral irradiances from a synergy of instruments and models. The satellite-based Tropospheric Emission Monitoring Internet Service (TEMIS; version 1.4) UV daily dose data products were evaluated over the period 2009 to 2014 with ground-based data from a Norsk Institutt for Luftforskning (NILU)-UV multifilter radiometer located at the northern midlatitude super-site of the Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki (LAP/AUTh), in Greece. For the NILU-UV effective dose rates retrieval algorithm, a neural network (NN) was trained to learn the nonlinear functional relation between NILU-UV irradiances and collocated Brewer-based photobiological effective dose products. Then the algorithm was subjected to sensitivity analysis and validation. The correlation of the NN estimates with target outputs was high (r = 0. 988 to 0.990) and with a very low bias (0.000 to 0.011 in absolute units) proving the robustness of the NN algorithm. For further evaluation of the NILU NN-derived products, retrievals of the vitamin D and DNA-damage effective doses from a collocated Yankee Environmental Systems (YES) UVB-1 pyranometer were used. For cloud-free days, differences in the derived UV doses are better than 2 % for all UV dose products, revealing the reference quality of the ground-based UV doses at Thessaloniki from the NILU-UV NN retrievals. The TEMIS UV doses used in this study are derived from ozone measurements by the SCIAMACHY/Envisat and GOME2/MetOp-A satellite instruments, over the European domain in combination with SEVIRI/Meteosat-based diurnal cycle of the cloud cover fraction per 0. 5° × 0. 5° (lat × long) grid cells. TEMIS UV doses were found to be ∼ 12.5 % higher than the NILU NN estimates but, despite the presence of a visually apparent seasonal pattern, the R2 values were found to be robustly high and equal to 0.92–0.93 for 1588 all-sky coincidences. These results significantly improve when limiting the dataset to cloud-free days with differences of 0.57 % for the erythemal doses, 1.22 % for the vitamin D doses, and 1.18 % for the DNA-damage doses, with standard deviations of the order of 11–13 %. The improvement of the comparative statistics under cloud-free cases further testifies to the importance of the appropriate consideration of the contribution of clouds in the UV radiation reaching the Earth's surface. For the urban area of Thessaloniki, with highly variable aerosol, the weakness of the implicit aerosol information introduced to the TEMIS UV dose algorithm was revealed by comparison of the datasets to aerosol optical depths at 340 nm as reported by a collocated CIMEL sun photometer, operating in Thessaloniki at LAP/AUTh as part of the NASA Aerosol Robotic Network.
- 16 June 2017
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 17 (11) , 7157-7174
Open AccessTEMIS UV product validation using NILU-UV ground-based measurements in Thessaloniki, Greece
This study aims to cross-validate ground-based and satellite-based models of three photobiological UV effective dose products: the Commission Internationale de l'Éclairage (CIE) erythemal UV, the production of vitamin D in the skin, and DNA damage, using high-temporal-resolution surface-based measurements of solar UV spectral irradiances from a synergy of instruments and models. The satellite-based Tropospheric Emission Monitoring Internet Service (TEMIS; version 1.4) UV daily dose data products were evaluated over the period 2009 to 2014 with ground-based data from a Norsk Institutt for Luftforskning (NILU)-UV multifilter radiometer located at the northern midlatitude super-site of the Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki (LAP/AUTh), in Greece. For the NILU-UV effective dose rates retrieval algorithm, a neural network (NN) was trained to learn the nonlinear functional relation between NILU-UV irradiances and collocated Brewer-based photobiological effective dose products. Then the algorithm was subjected to sensitivity analysis and validation. The correlation of the NN estimates with target outputs was high (r = 0. 988 to 0.990) and with a very low bias (0.000 to 0.011 in absolute units) proving the robustness of the NN algorithm. For further evaluation of the NILU NN-derived products, retrievals of the vitamin D and DNA-damage effective doses from a collocated Yankee Environmental Systems (YES) UVB-1 pyranometer were used. For cloud-free days, differences in the derived UV doses are better than 2 % for all UV dose products, revealing the reference quality of the ground-based UV doses at Thessaloniki from the NILU-UV NN retrievals. The TEMIS UV doses used in this study are derived from ozone measurements by the SCIAMACHY/Envisat and GOME2/MetOp-A satellite instruments, over the European domain in combination with SEVIRI/Meteosat-based diurnal cycle of the cloud cover fraction per 0. 5° × 0. 5° (lat × long) grid cells. TEMIS UV doses were found to be ∼ 12.5 % higher than the NILU NN estimates but, despite the presence of a visually apparent seasonal pattern, the R2 values were found to be robustly high and equal to 0.92–0.93 for 1588 all-sky coincidences. These results significantly improve when limiting the dataset to cloud-free days with differences of 0.57 % for the erythemal doses, 1.22 % for the vitamin D doses, and 1.18 % for the DNA-damage doses, with standard deviations of the order of 11–13 %. The improvement of the comparative statistics under cloud-free cases further testifies to the importance of the appropriate consideration of the contribution of clouds in the UV radiation reaching the Earth's surface. For the urban area of Thessaloniki, with highly variable aerosol, the weakness of the implicit aerosol information introduced to the TEMIS UV dose algorithm was revealed by comparison of the datasets to aerosol optical depths at 340 nm as reported by a collocated CIMEL sun photometer, operating in Thessaloniki at LAP/AUTh as part of the NASA Aerosol Robotic Network.
- Open Access
- 16 February 2017
- Published by Copernicus GmbH in EGUsphere
- p. 1-26
TEMIS UV product validation using NILU-UV ground-based measurements in Thessaloniki, Greece
This study aims to cross-validate ground-based and satellite-based models of three photobiological UV effective dose products: the CIE erythemal UV, the production of vitamin D in the skin and DNA-damage, using high temporal resolution surface-based measurements of solar UV spectral irradiances from a synergy of instruments and models. The satellite-based Tropospheric Emission Monitoring Internet Service (TEMIS; version 1.4) UV daily dose data products were evaluated over the period 2009 to 2014 with ground-based data from a NILU-UV multifilter radiometer located at the Northern mid-latitude super site of the Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki (LAP/AUTh) in Greece. For the NILU-UV effective dose rates retrieval algorithm, a neural network (NN) was trained to learn the nonlinear functional relation between NILU-UV irradiances and collocated Brewer-based photobiological effective dose products. Then the algorithm was subjected to sensitivity analysis and validation. The correlation of the NN estimates with target outputs was high (r = 0.988 to 0.990) and with a very low bias (0.000 to 0.011 in absolute units) proving the robustness of the NN algorithm. For further evaluation of the NILU NN derived products, retrievals of the vitamin D and DNA-damage effective doses from a collocated YES UVB-1 pyranometer where used. For cloud free days, differences in the derived UV doses are better than 2 % for all UV doses products, revealing the reference quality of the ground-based UV doses at Thessaloniki from the NILU-UV NN retrievals. The TEMIS UV doses used in this study, are derived from ozone measurements by the SCIAMACHY/Envisat and GOME2/MetOp-A satellite instruments, over the European domain in combination with SEVIRI/Meteosat based diurnal cycle of the cloud cover fraction per 0.5° × 0.5° (lat × lon) grid cells. TEMIS UV doses were found to be ~ 12.5 % higher than the NILU NN estimates but, despite the presence of a visually apparent seasonal pattern, the R2 values were found to be robustly high and equal to 0.92–0.93 for 1.588 all sky coincidences. These results significantly improve when limiting the dataset to cloud free days with differences of 0.57 % for the erythemal doses, 1.22 % for the vitamin D doses and 1.18 % for the DNA-damage doses, with standard deviations of the order of 11–13 %. The improvement of the comparative statistics under cloud-free cases further testifies to the importance of the appropriate consideration of the contribution of clouds in the UV radiation reaching the Earth's surface. For the urban area of Thessaloniki with highly variable aerosol the weakness of the implicit aerosol information introduced to the TEMIS UV dose algorithm was revealed by comparison of the datasets to aerosol optical depths at 340 nm as reported by a collocated CIMEL sunphotometer, operating in Thessaloniki at LAP/AUTh as part of the NASA Aerosol Robotic Network.
- 16 February 2017
- Published by Copernicus GmbH in EGUsphere
- p. 1-26
Open AccessTEMIS UV product validation using NILU-UV ground-based measurements in Thessaloniki, Greece
This study aims to cross-validate ground-based and satellite-based models of three photobiological UV effective dose products: the CIE erythemal UV, the production of vitamin D in the skin and DNA-damage, using high temporal resolution surface-based measurements of solar UV spectral irradiances from a synergy of instruments and models. The satellite-based Tropospheric Emission Monitoring Internet Service (TEMIS; version 1.4) UV daily dose data products were evaluated over the period 2009 to 2014 with ground-based data from a NILU-UV multifilter radiometer located at the Northern mid-latitude super site of the Laboratory of Atmospheric Physics, Aristotle University of Thessaloniki (LAP/AUTh) in Greece. For the NILU-UV effective dose rates retrieval algorithm, a neural network (NN) was trained to learn the nonlinear functional relation between NILU-UV irradiances and collocated Brewer-based photobiological effective dose products. Then the algorithm was subjected to sensitivity analysis and validation. The correlation of the NN estimates with target outputs was high (r = 0.988 to 0.990) and with a very low bias (0.000 to 0.011 in absolute units) proving the robustness of the NN algorithm. For further evaluation of the NILU NN derived products, retrievals of the vitamin D and DNA-damage effective doses from a collocated YES UVB-1 pyranometer where used. For cloud free days, differences in the derived UV doses are better than 2 % for all UV doses products, revealing the reference quality of the ground-based UV doses at Thessaloniki from the NILU-UV NN retrievals. The TEMIS UV doses used in this study, are derived from ozone measurements by the SCIAMACHY/Envisat and GOME2/MetOp-A satellite instruments, over the European domain in combination with SEVIRI/Meteosat based diurnal cycle of the cloud cover fraction per 0.5° × 0.5° (lat × lon) grid cells. TEMIS UV doses were found to be ~ 12.5 % higher than the NILU NN estimates but, despite the presence of a visually apparent seasonal pattern, the R2 values were found to be robustly high and equal to 0.92–0.93 for 1.588 all sky coincidences. These results significantly improve when limiting the dataset to cloud free days with differences of 0.57 % for the erythemal doses, 1.22 % for the vitamin D doses and 1.18 % for the DNA-damage doses, with standard deviations of the order of 11–13 %. The improvement of the comparative statistics under cloud-free cases further testifies to the importance of the appropriate consideration of the contribution of clouds in the UV radiation reaching the Earth's surface. For the urban area of Thessaloniki with highly variable aerosol the weakness of the implicit aerosol information introduced to the TEMIS UV dose algorithm was revealed by comparison of the datasets to aerosol optical depths at 340 nm as reported by a collocated CIMEL sunphotometer, operating in Thessaloniki at LAP/AUTh as part of the NASA Aerosol Robotic Network.
- 10 September 2016
- Published by Springer Nature
- p. 1187-1192
Introducing a Cloud Screening Detector Using Global Horizontal Irradiances in UV and PAR in Thessaloniki, Greece
- 10 September 2016
- Published by Springer Nature
- p. 1187-1192
Introducing a Cloud Screening Detector Using Global Horizontal Irradiances in UV and PAR in Thessaloniki, Greece
- 1 September 2016
- Published by Elsevier in Atmospheric Environment
- Vol. 140, 283-297
OMI/Aura UV product validation using NILU-UV ground-based measurements in Thessaloniki, Greece
- 1 September 2016
- Published by Elsevier in Atmospheric Environment
- Vol. 140, 283-297
OMI/Aura UV product validation using NILU-UV ground-based measurements in Thessaloniki, Greece
- Open Access
- 1 March 2016
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 16 (4) , 2493-2505
Short- and long-term variability of spectral solar UV irradiance at Thessaloniki, Greece: effects of changes in aerosols, total ozone and clouds
In this study, we discuss the short- and the long-term variability of spectral UV irradiance at Thessaloniki, Greece, using a long, quality-controlled data set from two Brewer spectrophotometers. Long-term changes in spectral UV irradiance at 307.5, 324 and 350 nm for the period 1994–2014 are presented for different solar zenith angles and discussed in association with changes in total ozone column (TOC), aerosol optical depth (AOD) and cloudiness observed in the same period. Positive changes in annual mean anomalies of UV irradiance, ranging from 2 to 6 % per decade, have been detected both for clear- and all-sky conditions. The changes are generally greater for larger solar zenith angles and for shorter wavelengths. For clear-skies, these changes are, in most cases, statistically significant at the 95 % confidence limit. Decreases in the aerosol load and weakening of the attenuation by clouds lead to increases in UV irradiance in the summer, of 7–9 % per decade for 64° solar zenith angle. The increasing TOC in winter counteracts the effect of decreasing AOD for this particular season, leading to small, statistically insignificant, negative long-term changes in irradiance at 307.5 nm. Annual mean UV irradiance levels are increasing from 1994 to 2006 and remain relatively stable thereafter, possibly due to the combined changes in the amount and optical properties of aerosols. However, no statistically significant corresponding turning point has been detected in the long-term changes of AOD. The absence of signatures of changes in AOD in the short-term variability of irradiance in the UV-A may have been caused by changes in the single scattering albedo of aerosols, which may counteract the effects of changes in AOD on irradiance. The anti-correlation between the year-to-year variability of the irradiance at 307.5 nm and TOC is clear and becomes clearer as the AOD decreases.
- 1 March 2016
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 16 (4) , 2493-2505
Open AccessShort- and long-term variability of spectral solar UV irradiance at Thessaloniki, Greece: effects of changes in aerosols, total ozone and clouds
In this study, we discuss the short- and the long-term variability of spectral UV irradiance at Thessaloniki, Greece, using a long, quality-controlled data set from two Brewer spectrophotometers. Long-term changes in spectral UV irradiance at 307.5, 324 and 350 nm for the period 1994–2014 are presented for different solar zenith angles and discussed in association with changes in total ozone column (TOC), aerosol optical depth (AOD) and cloudiness observed in the same period. Positive changes in annual mean anomalies of UV irradiance, ranging from 2 to 6 % per decade, have been detected both for clear- and all-sky conditions. The changes are generally greater for larger solar zenith angles and for shorter wavelengths. For clear-skies, these changes are, in most cases, statistically significant at the 95 % confidence limit. Decreases in the aerosol load and weakening of the attenuation by clouds lead to increases in UV irradiance in the summer, of 7–9 % per decade for 64° solar zenith angle. The increasing TOC in winter counteracts the effect of decreasing AOD for this particular season, leading to small, statistically insignificant, negative long-term changes in irradiance at 307.5 nm. Annual mean UV irradiance levels are increasing from 1994 to 2006 and remain relatively stable thereafter, possibly due to the combined changes in the amount and optical properties of aerosols. However, no statistically significant corresponding turning point has been detected in the long-term changes of AOD. The absence of signatures of changes in AOD in the short-term variability of irradiance in the UV-A may have been caused by changes in the single scattering albedo of aerosols, which may counteract the effects of changes in AOD on irradiance. The anti-correlation between the year-to-year variability of the irradiance at 307.5 nm and TOC is clear and becomes clearer as the AOD decreases.
- 1 February 2016
- Published by Elsevier in Renewable Energy
- Vol. 86, 831-840
Evaluation of WRF shortwave radiation parameterizations in predicting Global Horizontal Irradiance in Greece
- 1 February 2016
- Published by Elsevier in Renewable Energy
- Vol. 86, 831-840
Evaluation of WRF shortwave radiation parameterizations in predicting Global Horizontal Irradiance in Greece