Hossein Aghili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hossein Aghili has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Soghra Yassaei
Department of Orthodontics, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
9 shared publications - Mahdjoube Goldani Moghadam
Department of Orthodontics, School of Dentistry, Birjand University of Medical Sciences, Birjand, Iran
4 shared publications - Neda Joshan
Sahid Sadoughi University of Medical Sciences, Iran
2 shared publications - Abbas Ali Jafari Nadoushan
Associate Professor, Department of Medical Parasitology and Mycology, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
1 shared publication Abdolrahim Davari
Department of Operative, Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
1 shared publicationAfsane Zahtabche Khuzani
Private Practice, Yazd, Iran
1 shared publication
Latest Publications
- Open Access
- 23 September 2025
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 16, e39
Effect of 980nm Low-Level Laser Therapy on Matrix Metalloproteinase-1 Levels in Gingival Crevicular Fluid During Fixed Orthodontic Treatment
Introduction: Given the unique biostimulatory effects of low-level lasers, particularly on collagen production and fibroblast activity, this study aimed to measure the changes in MMP-1 levels in response to low-level laser therapy (LLLT) in individuals undergoing orthodontic treatment. The increase in MMP-1 may signal beneficial tissue adaptation to orthodontic force. Methods: This double-blind, randomized clinical trial included 22 individuals referred to the orthodontic department of Yazd Faculty of Dentistry who required fixed orthodontic treatment. The left and right mandibular anterior teeth of patients meeting the inclusion criteria were randomly assigned to the intervention and control sides. A low-level diode laser (980 nm, 100 mW output power) was applied to two teeth in the intervention group for two consecutive days. Gingival crevicular fluid (GCF) samples were collected from both sides at 24 hours (T1) and 164 hours (T2) post-irradiation. MMP-1 levels were measured using ELISA. Data were analyzed using SPSS software with independent and paired t-tests, with a significance level set at 0.05. Results: At T1, the mean MMP-1 level in the intervention group was 6.77±0.54 ng/mL, which was significantly higher than the control group’s level of 6.15±0.40 ng/mL (P<0.001). At T2, the mean MMP-1 level in the intervention group (6.20±0.62 ng/mL) was not significantly different from that in the control group (6.21±0.55 ng/mL) (P=0.960). The average MMP-1 level in the control group did not differ significantly between T1 and T2 (P=0.546). However, the mean MMP-1 level in the intervention group at T1 was significantly higher than at T2 (P<0.001). Conclusion: MMP-1 levels in GCF increase temporarily after low-level laser irradiation with orthodontic force, indicating a potentially beneficial effect on tissue remodeling. Levels return to baseline by 164 hours, suggesting a controlled, short-term response.
- 23 September 2025
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 16, e39
Open AccessEffect of 980nm Low-Level Laser Therapy on Matrix Metalloproteinase-1 Levels in Gingival Crevicular Fluid During Fixed Orthodontic Treatment
Introduction: Given the unique biostimulatory effects of low-level lasers, particularly on collagen production and fibroblast activity, this study aimed to measure the changes in MMP-1 levels in response to low-level laser therapy (LLLT) in individuals undergoing orthodontic treatment. The increase in MMP-1 may signal beneficial tissue adaptation to orthodontic force. Methods: This double-blind, randomized clinical trial included 22 individuals referred to the orthodontic department of Yazd Faculty of Dentistry who required fixed orthodontic treatment. The left and right mandibular anterior teeth of patients meeting the inclusion criteria were randomly assigned to the intervention and control sides. A low-level diode laser (980 nm, 100 mW output power) was applied to two teeth in the intervention group for two consecutive days. Gingival crevicular fluid (GCF) samples were collected from both sides at 24 hours (T1) and 164 hours (T2) post-irradiation. MMP-1 levels were measured using ELISA. Data were analyzed using SPSS software with independent and paired t-tests, with a significance level set at 0.05. Results: At T1, the mean MMP-1 level in the intervention group was 6.77±0.54 ng/mL, which was significantly higher than the control group’s level of 6.15±0.40 ng/mL (P<0.001). At T2, the mean MMP-1 level in the intervention group (6.20±0.62 ng/mL) was not significantly different from that in the control group (6.21±0.55 ng/mL) (P=0.960). The average MMP-1 level in the control group did not differ significantly between T1 and T2 (P=0.546). However, the mean MMP-1 level in the intervention group at T1 was significantly higher than at T2 (P<0.001). Conclusion: MMP-1 levels in GCF increase temporarily after low-level laser irradiation with orthodontic force, indicating a potentially beneficial effect on tissue remodeling. Levels return to baseline by 164 hours, suggesting a controlled, short-term response.
- Open Access
- 11 October 2023
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 14, e42
Effect of Erbium:YAG Laser Recycling on Mechanical Characteristics of Retrieved Orthodontic Mini-screws
Introduction: This study aimed to evaluate the influence of two recycling methods on the mechanical and surface characteristics of orthodontic mini-screws. Methods: Thirty-six retrieved mini-screws were randomly classified into two equal groups. In the first group (laser recycled group (LG)), the Er:YAG laser (2940 nm, 5.5 W, 275 mJ, perpendicular to the mini-screws at a distance of 7-10 mm, 25 s) was used to recycle mini-screws. In the second group (phosphoric acid and sodium hypochlorite recycled group (ASG)), the mini-screws were kept in 37% phosphoric acid gel (10 minutes) and then placed in 5.25% sodium hypochlorite for 30 minutes. Eighteen new mini-screws were selected as the control group (CG). Maximum insertion torque (MIT), maximum removal torque (MRT), and fracture torque (FT) of all mini-screws were measured. A sample from each group was examined for the surface changes of the mini-screw and tissue remnants under a scanning electron microscope (SEM). Results: The mean MIT was significantly higher in both LG and ASG groups than the CG (P<0.001 and P=0.002, respectively). However, no significant difference was shown between the LG and ASG groups. The mean values of MRT and FT showed no significant difference between the groups. The amount of tissue remnants in the ASG group was significantly higher than that in the LG group. The evidence of porosity and corrosion was observed on the ASG mini-screw surface, and there was an increase in roughness on the LG mini-screw surface. Conclusion: The Er:YAG laser recycling of mini-screws is a proper method causing minimum damage to the screw surface.
- 11 October 2023
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 14, e42
Open AccessEffect of Erbium:YAG Laser Recycling on Mechanical Characteristics of Retrieved Orthodontic Mini-screws
Introduction: This study aimed to evaluate the influence of two recycling methods on the mechanical and surface characteristics of orthodontic mini-screws. Methods: Thirty-six retrieved mini-screws were randomly classified into two equal groups. In the first group (laser recycled group (LG)), the Er:YAG laser (2940 nm, 5.5 W, 275 mJ, perpendicular to the mini-screws at a distance of 7-10 mm, 25 s) was used to recycle mini-screws. In the second group (phosphoric acid and sodium hypochlorite recycled group (ASG)), the mini-screws were kept in 37% phosphoric acid gel (10 minutes) and then placed in 5.25% sodium hypochlorite for 30 minutes. Eighteen new mini-screws were selected as the control group (CG). Maximum insertion torque (MIT), maximum removal torque (MRT), and fracture torque (FT) of all mini-screws were measured. A sample from each group was examined for the surface changes of the mini-screw and tissue remnants under a scanning electron microscope (SEM). Results: The mean MIT was significantly higher in both LG and ASG groups than the CG (P<0.001 and P=0.002, respectively). However, no significant difference was shown between the LG and ASG groups. The mean values of MRT and FT showed no significant difference between the groups. The amount of tissue remnants in the ASG group was significantly higher than that in the LG group. The evidence of porosity and corrosion was observed on the ASG mini-screw surface, and there was an increase in roughness on the LG mini-screw surface. Conclusion: The Er:YAG laser recycling of mini-screws is a proper method causing minimum damage to the screw surface.
- Open Access
- 1 January 2023
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 14, e12
Effect of Low-Level Laser Therapy on Patients With Class II Mandibular Deficiency Treated with Farmand Functional Appliance
Introduction: Considering the positive effects of a low-level laser on new bone formation, we aimed to investigate the effects of a low-level laser in the treatment of patients with class II mandibular deficiency treated with Farmand functional appliance. Methods: Twenty-two growing patients aged 10-14 years were randomly divided into "Farmand" and "Farmand+Laser" groups. All patients were treated with Farmand functional appliance. Patients in the "Farmand+laser" group were exposed to laser irradiation (980 nm, 100 mw, 4 points around temporomandibular joints, 100 seconds each point) weekly for three months after 3-4 weeks of using the appliance. Lateral cephalometry radiographs were taken from all patients before and after the treatment period, and changes in skeletal and dental parameters were measured. Results: The association of the particular laser irradiation with the functional appliance led to a greater increase in the effective length of the mandible (Co-Gn, P=0.048), the anterior sagittal position of the mandible (SNB, P=0.029), and the length of the ramus (Co-Go, P=0.028), and it showed a further decrease in the discrepancy between the jaws (ANB, P=0.000) compared with the functional appliance alone. Conclusion: The application of the laser with the chosen parameters and protocol in conjunction with the functional appliance improved the effects of the functional appliance and reduced the discrepancy between the two jaws.
- 1 January 2023
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 14, e12
Open AccessEffect of Low-Level Laser Therapy on Patients With Class II Mandibular Deficiency Treated with Farmand Functional Appliance
Introduction: Considering the positive effects of a low-level laser on new bone formation, we aimed to investigate the effects of a low-level laser in the treatment of patients with class II mandibular deficiency treated with Farmand functional appliance. Methods: Twenty-two growing patients aged 10-14 years were randomly divided into "Farmand" and "Farmand+Laser" groups. All patients were treated with Farmand functional appliance. Patients in the "Farmand+laser" group were exposed to laser irradiation (980 nm, 100 mw, 4 points around temporomandibular joints, 100 seconds each point) weekly for three months after 3-4 weeks of using the appliance. Lateral cephalometry radiographs were taken from all patients before and after the treatment period, and changes in skeletal and dental parameters were measured. Results: The association of the particular laser irradiation with the functional appliance led to a greater increase in the effective length of the mandible (Co-Gn, P=0.048), the anterior sagittal position of the mandible (SNB, P=0.029), and the length of the ramus (Co-Go, P=0.028), and it showed a further decrease in the discrepancy between the jaws (ANB, P=0.000) compared with the functional appliance alone. Conclusion: The application of the laser with the chosen parameters and protocol in conjunction with the functional appliance improved the effects of the functional appliance and reduced the discrepancy between the two jaws.
- 1 September 2017
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 35 (9) , 492-497
Effect of Carbon Dioxide Laser on Increasing Vestibular Depth in Cleft Lip and Palate Patients
Background: Shallow upper buccal sulcus deformity in cleft lip and palate patients is one of the common secondary deformities after primary cleft lip and palate repair; this deformity may prevent or complicate orthodontic and prosthodontic procedures causing aesthetic and functional problems. A number of methods are described to increase the anterior maxillary sulcus in these patients. Purpose: This study assessed the use of a carbon dioxide laser (CO 2 ) to increase the sulcus depth. Method: Fifteen patients with cleft lip and palate (eight unilateral and seven bilateral) were studied. The surgical procedure was performed using CO 2 laser. The vestibular depth and lip length were measured at three time points namely before surgery (T0), 1 week following surgery (T1), and 4 months following surgery (T2). After data collection, statistical analyses were done using PASW ® version 18 SPSS. Results: The mean values of vestibular depth were 9.46 ± 1.92, 13.83 ± 1.88, and 13.23 ± 1.76 mm for T0, T1, and T2, respectively. The vestibular depth significantly increased after 4 months of follow-up ( p = 0.001). The mean amount of vestibular depth gain was not significantly different in unilateral and bilateral cleft groups ( p = 0.908). The mean value of upper lip length increased by a mean of 1.23 mm and was statistically significant ( p = 0.001). Conclusions: Upper buccal sulcus reconstruction with CO 2 laser provides successful and stable results. CO 2 laser application is suggested as an alternative to conventional vestibuloplasty.
- 1 September 2017
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 35 (9) , 492-497
Effect of Carbon Dioxide Laser on Increasing Vestibular Depth in Cleft Lip and Palate Patients
Background: Shallow upper buccal sulcus deformity in cleft lip and palate patients is one of the common secondary deformities after primary cleft lip and palate repair; this deformity may prevent or complicate orthodontic and prosthodontic procedures causing aesthetic and functional problems. A number of methods are described to increase the anterior maxillary sulcus in these patients. Purpose: This study assessed the use of a carbon dioxide laser (CO 2 ) to increase the sulcus depth. Method: Fifteen patients with cleft lip and palate (eight unilateral and seven bilateral) were studied. The surgical procedure was performed using CO 2 laser. The vestibular depth and lip length were measured at three time points namely before surgery (T0), 1 week following surgery (T1), and 4 months following surgery (T2). After data collection, statistical analyses were done using PASW ® version 18 SPSS. Results: The mean values of vestibular depth were 9.46 ± 1.92, 13.83 ± 1.88, and 13.23 ± 1.76 mm for T0, T1, and T2, respectively. The vestibular depth significantly increased after 4 months of follow-up ( p = 0.001). The mean amount of vestibular depth gain was not significantly different in unilateral and bilateral cleft groups ( p = 0.908). The mean value of upper lip length increased by a mean of 1.23 mm and was statistically significant ( p = 0.001). Conclusions: Upper buccal sulcus reconstruction with CO 2 laser provides successful and stable results. CO 2 laser application is suggested as an alternative to conventional vestibuloplasty.
- Open Access
- 8 January 2017
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 8 (1) , 17-21
Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets
Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets
- 8 January 2017
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 8 (1) , 17-21
Open AccessEffect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets
Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets
- Open Access
- 1 September 2015
- Vol. 12 (9) , 695-704
Load Deflection Characteristics of Nickel Titanium Initial Archwires
The aim of this study was to assess and compare the characteristics of commonly used initial archwires by their load deflection graphs. This study tested three wire designs namely copper nickel titanium (CNT), nickel titanium (NiTi), and multi-strand NiTi (MSNT) archwires engaged in passive self-ligating (PSL) brackets, active self-ligating (ASL) brackets or conventional brackets. To evaluate the mechanical characteristics of the specimens, a three-point bending test was performed. The testing machine vertically applied force on the midpoint of the wire between the central incisor and canine teeth to obtain 2 and 4mm of deflection. The force level at maximum deflection and characteristics of plateau (the average plateau load and the plateau length) were recorded. Two-way ANOVA and Tukey’s test were used at P <0.05 level of significance. Force level at maximum deflection and plateau length were significantly affected by the amount of deflection. The type of archwires and brackets had significant effects on force level at maximum deflection, and plateau length. However, the bracket type had no significant effect on the average plateau force. With any type of brackets in deflections of 2 and 4mm, MSNT wire exerted the lowest while NiTi wire exerted the highest force level at maximum deflection and plateau phase. The force level at maximum deflection and the plateau length increased with raising the amount of primary deflection; however the average plateau force did not change significantly.
- 1 September 2015
- Vol. 12 (9) , 695-704
Open AccessLoad Deflection Characteristics of Nickel Titanium Initial Archwires
The aim of this study was to assess and compare the characteristics of commonly used initial archwires by their load deflection graphs. This study tested three wire designs namely copper nickel titanium (CNT), nickel titanium (NiTi), and multi-strand NiTi (MSNT) archwires engaged in passive self-ligating (PSL) brackets, active self-ligating (ASL) brackets or conventional brackets. To evaluate the mechanical characteristics of the specimens, a three-point bending test was performed. The testing machine vertically applied force on the midpoint of the wire between the central incisor and canine teeth to obtain 2 and 4mm of deflection. The force level at maximum deflection and characteristics of plateau (the average plateau load and the plateau length) were recorded. Two-way ANOVA and Tukey’s test were used at P <0.05 level of significance. Force level at maximum deflection and plateau length were significantly affected by the amount of deflection. The type of archwires and brackets had significant effects on force level at maximum deflection, and plateau length. However, the bracket type had no significant effect on the average plateau force. With any type of brackets in deflections of 2 and 4mm, MSNT wire exerted the lowest while NiTi wire exerted the highest force level at maximum deflection and plateau phase. The force level at maximum deflection and the plateau length increased with raising the amount of primary deflection; however the average plateau force did not change significantly.
- Open Access
- 26 May 2015
- Vol. 12 (3) , 254-259
Effects of removing adhesive from tooth surfaces by Er:YAG laser and a composite bur on enamel surface roughnessand pulp chamber temperature
At the end of fixed orthodontic treatment, the remnant of adhesive should be eliminated from the tooth surface. The purpose of this study was to compare the effect of three methods of removing adhesive on enamel surface roughness, dental pulp temperature, and also on the time spent. The brackets on 90 extracted teeth were debonded using bracket removal pliers. A thermocouple sensor was fitted on the buccal wall of the pulp chamber through access cavity to measure thermal changes during adhesive removal. The residue of adhesive was eliminated from enamel surface of teeth by either tungsten carbide bur, erbium-doped yttrium aluminum garnet laser, or fiber reinforced composite bur. Scanning electron micrographs images were taken to assess the roughness of enamel surface. The time spent for adhesive removal was recorded as well. Chi-square test was used to evaluate the remnants of adhesive and enamel surface roughness; t-test and also repeated measurement analysis of variance were applied at P < 0.05 to compare the thermal changes of the pulp chamber and time spent between the methods of surface treatment. The results of surface roughness were significantly different (P < 0.001). The pulp temperature changed significantly (P < 0.001). Tungsten carbide bur increased the temperature by 5.5°C significantly slower than reinforced composite bur (P = 0.004), however removed the adhesive residue faster than two other methods although not significantly (P = 0.069). Within the limitations of this study, fiber reinforced composite bur created the smoothest enamel surface while Er:YAG laser the roughest. Tungsten carbide and composite burs generated more heat compared to Er:YAG laser. In addition, tungsten carbide bur was the fastest and Er:YAG laser the slowest devices to remove adhesive residue.
- 26 May 2015
- Vol. 12 (3) , 254-259
Open AccessEffects of removing adhesive from tooth surfaces by Er:YAG laser and a composite bur on enamel surface roughnessand pulp chamber temperature
At the end of fixed orthodontic treatment, the remnant of adhesive should be eliminated from the tooth surface. The purpose of this study was to compare the effect of three methods of removing adhesive on enamel surface roughness, dental pulp temperature, and also on the time spent. The brackets on 90 extracted teeth were debonded using bracket removal pliers. A thermocouple sensor was fitted on the buccal wall of the pulp chamber through access cavity to measure thermal changes during adhesive removal. The residue of adhesive was eliminated from enamel surface of teeth by either tungsten carbide bur, erbium-doped yttrium aluminum garnet laser, or fiber reinforced composite bur. Scanning electron micrographs images were taken to assess the roughness of enamel surface. The time spent for adhesive removal was recorded as well. Chi-square test was used to evaluate the remnants of adhesive and enamel surface roughness; t-test and also repeated measurement analysis of variance were applied at P < 0.05 to compare the thermal changes of the pulp chamber and time spent between the methods of surface treatment. The results of surface roughness were significantly different (P < 0.001). The pulp temperature changed significantly (P < 0.001). Tungsten carbide bur increased the temperature by 5.5°C significantly slower than reinforced composite bur (P = 0.004), however removed the adhesive residue faster than two other methods although not significantly (P = 0.069). Within the limitations of this study, fiber reinforced composite bur created the smoothest enamel surface while Er:YAG laser the roughest. Tungsten carbide and composite burs generated more heat compared to Er:YAG laser. In addition, tungsten carbide bur was the fastest and Er:YAG laser the slowest devices to remove adhesive residue.
- Open Access
- 1 January 2015
- Vol. 12 (1) , 1-10
Antimicrobial Effect of Zataria Multiflora Extract in Comparison with Chlorhexidine Mouthwash on Experimentally Contaminated Orthodontic Elastomeric Ligatures
Long-term use of orthodontic appliances and fixation ligatures creates a favorable environment for the accumulation of oral normal microflora and increases the risk of enamel demineralization and periodontal disease. The aim of this study was to compare the antimicrobial effects of Zataria Multiflora extract and 0.2% chlorhexidine (CHX) mouthwash on experimentally contaminated orthodontic elastomeric ligatures. In this lab trial study, Iranian and foreign-made elastomeric ligatures were experimentally contaminated in Streptococcus mutans, Enterococcus faecalis and Candida albicans suspensions. Ligatures were then decontaminated using 0.2% CHX as the control, 0.5 mg/ml Zataria multiflora extract mouthwashes as the test and phosphate buffered saline (PBS) as the negative control for one hour. Antimicrobial properties of both solutions were evaluated by comparing the mean viable bacterial cell count on both rings after decontamination, using SPSS version 15 software. The mean viable bacterial cell count on Iranian ligatures was greater than that on foreign-made ligatures before disinfection (P=0.001), however this difference for C. albicans was not statistically significant (P=0.061). Chlorhexidine mouthwash completely eliminated all tested microorganisms attached to both elastomeric rings, but Zataria extract was only capable of completely eliminating C. albicans from both ligatures. Statistically significant differences were found in viable bacterial counts on both ligatures before and after disinfection with Zataria extract (P=0.0001). Zataria multiflora extract has antimicrobial properties and can be used for disinfection of elastomeric ligatures. In vivo studies are required to evaluate the efficacy of the incorporation of this herbal extract in mouthwashes for orthodontic patients.
- 1 January 2015
- Vol. 12 (1) , 1-10
Open AccessAntimicrobial Effect of Zataria Multiflora Extract in Comparison with Chlorhexidine Mouthwash on Experimentally Contaminated Orthodontic Elastomeric Ligatures
Long-term use of orthodontic appliances and fixation ligatures creates a favorable environment for the accumulation of oral normal microflora and increases the risk of enamel demineralization and periodontal disease. The aim of this study was to compare the antimicrobial effects of Zataria Multiflora extract and 0.2% chlorhexidine (CHX) mouthwash on experimentally contaminated orthodontic elastomeric ligatures. In this lab trial study, Iranian and foreign-made elastomeric ligatures were experimentally contaminated in Streptococcus mutans, Enterococcus faecalis and Candida albicans suspensions. Ligatures were then decontaminated using 0.2% CHX as the control, 0.5 mg/ml Zataria multiflora extract mouthwashes as the test and phosphate buffered saline (PBS) as the negative control for one hour. Antimicrobial properties of both solutions were evaluated by comparing the mean viable bacterial cell count on both rings after decontamination, using SPSS version 15 software. The mean viable bacterial cell count on Iranian ligatures was greater than that on foreign-made ligatures before disinfection (P=0.001), however this difference for C. albicans was not statistically significant (P=0.061). Chlorhexidine mouthwash completely eliminated all tested microorganisms attached to both elastomeric rings, but Zataria extract was only capable of completely eliminating C. albicans from both ligatures. Statistically significant differences were found in viable bacterial counts on both ligatures before and after disinfection with Zataria extract (P=0.0001). Zataria multiflora extract has antimicrobial properties and can be used for disinfection of elastomeric ligatures. In vivo studies are required to evaluate the efficacy of the incorporation of this herbal extract in mouthwashes for orthodontic patients.
- Open Access
- 1 March 2014
- Vol. 11 (2) , 193-198
Combined effects of Er: YAG laser and casein phosphopeptide-amorphous calcium phosphate on the inhibition of enamel demineralization: An in vitro study
Development of white spot lesions on enamel is a significant and common problem during the fixed orthodontic treatment. Various preventive methods have been suggested. The purpose of this study was to evaluate the preventive potential of MI Paste Plus, Er: YAG Laser and combined under similar in vitro conditions against demineralization. In this experimental in vitro study, 60 extracted premolars were randomly allocated to four groups (n = 15) of control, MI Paste Plus, Laser and MI + Laser (MIL). Enamel surface of each group was treated with one of above materials before and during the pH cycling for 12 days through a daily procedure of demineralization and remineralization for 3 h and 20 h, respectively. Teeth were sectioned and evaluated quantitatively by cross-sectional microhardness testing at 20 μm intervals from the outer enamel surface toward dentinoenamel junction up to 160 μm and data were analyzed using the one-way analysis of variance and Tukey test. P < 0.05 was considered as significant. MIL group had the least amount of demineralization (P < 0.001). Control group (C group) had the greatest relative mineral loss and the laser group (L group) had 45% less mineral loss than the C group and there was no significant difference between the MI Paste Plus and L group (P = 0.154) Based on these results, Er: YAG laser was able to decrease demineralization and was a potential alternative to preventive dentistry and was more effective when combined with casein phosphopeptide-amorphous calcium phosphate products.
- 1 March 2014
- Vol. 11 (2) , 193-198
Open AccessCombined effects of Er: YAG laser and casein phosphopeptide-amorphous calcium phosphate on the inhibition of enamel demineralization: An in vitro study
Development of white spot lesions on enamel is a significant and common problem during the fixed orthodontic treatment. Various preventive methods have been suggested. The purpose of this study was to evaluate the preventive potential of MI Paste Plus, Er: YAG Laser and combined under similar in vitro conditions against demineralization. In this experimental in vitro study, 60 extracted premolars were randomly allocated to four groups (n = 15) of control, MI Paste Plus, Laser and MI + Laser (MIL). Enamel surface of each group was treated with one of above materials before and during the pH cycling for 12 days through a daily procedure of demineralization and remineralization for 3 h and 20 h, respectively. Teeth were sectioned and evaluated quantitatively by cross-sectional microhardness testing at 20 μm intervals from the outer enamel surface toward dentinoenamel junction up to 160 μm and data were analyzed using the one-way analysis of variance and Tukey test. P < 0.05 was considered as significant. MIL group had the least amount of demineralization (P < 0.001). Control group (C group) had the greatest relative mineral loss and the laser group (L group) had 45% less mineral loss than the C group and there was no significant difference between the MI Paste Plus and L group (P = 0.154) Based on these results, Er: YAG laser was able to decrease demineralization and was a potential alternative to preventive dentistry and was more effective when combined with casein phosphopeptide-amorphous calcium phosphate products.
- 1 January 2014
- Vol. 52 (6) , 454-7
Body dysmorphic disorder in Iranian orthodontic patients.
Patient's preoccupations with perceived defect in appearance or excessive concern about minimal flaws are among diagnostic criteria of body dysmorphic disorder (BDD). Sufferers usually seek cosmetic procedures such as orthodontic treatment. This study was conducted to estimate the prevalence of BDD among a sample of Iranian orthodontic patients. A total of 270 orthodontic patients were evaluated with BDD-YBOCS questionnaire for the diagnosis of BDD. Fifteen patients (5.5%) were screened positive for BDD. BDD was more frequent among females, singles and in younger patients. Most of the BDD patients experienced multiple previous orthodontic evaluations. The relative high prevalence of BDD among orthodontic patients in Iran offers that orthodontists should take psychologically based problems such as BDD into account while evaluating patient's orthodontic problems.
- 1 January 2014
- Vol. 52 (6) , 454-7
Body dysmorphic disorder in Iranian orthodontic patients.
Patient's preoccupations with perceived defect in appearance or excessive concern about minimal flaws are among diagnostic criteria of body dysmorphic disorder (BDD). Sufferers usually seek cosmetic procedures such as orthodontic treatment. This study was conducted to estimate the prevalence of BDD among a sample of Iranian orthodontic patients. A total of 270 orthodontic patients were evaluated with BDD-YBOCS questionnaire for the diagnosis of BDD. Fifteen patients (5.5%) were screened positive for BDD. BDD was more frequent among females, singles and in younger patients. Most of the BDD patients experienced multiple previous orthodontic evaluations. The relative high prevalence of BDD among orthodontic patients in Iran offers that orthodontists should take psychologically based problems such as BDD into account while evaluating patient's orthodontic problems.