ISIvica Sović

Ivica Sović

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ivica Sović has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reanalysis of historical earthquakes to improve seismic hazard assessment: Case study of the 1880 Zagreb (Croatia) earthquake

    by Snježana Markušić, Davor Stanko, Ivica Sović, Marijan Kovačić, Bruno Mravlja, Iva Žilić


  • Open Access

    High frequency microseismic noise as possible earthquake precursor

    by Ivica Sović, Kristina Šariri, Mladen Živčić

    Before an earthquake occurs, microseismic noise in high frequency (HF) range, i.e. 2-25 Hz, is being generated during preparation process. These signals change the microseismic noise and, consequently, the spectrum of microseismic noise. Time variation of spectra recorded at the same seismological station could imply the change of the state of noise source. We propose the image moment analysis approach to objectively compare microseismic noise spectra. The result could be used for earthquake precursor identification. Expected spectra change is in HF range, so the analysis has been limited to the shallow tectonic earthquakes with epicenters close, up to 15 km, the seismological stations. The method has been tested post festum using four earthquakes in Dinarides which satisfied condition for epicentral distance. The spectra were calculated for noise recorded in time intervals of 10 days before and 6 to 10 days after the earthquakes. Affine moment invariants were calculated for noise spectra which were treated as the input objects. Spectra of the first five days in the series were referent spectra. The classification parameters were Euclidean distances between referent spectra and the spectra for all days in the series, including referent ones. The results have shown that the spectra of the microseismic noise become noticeably different than the other spectra in time intervals one or two days before an earthquake.


    • 1 May 2010
      • Vol. 41  (5) , 417-25

    Shrinkage evaluation of composite polymerized with LED units using laser interferometry.

    by Alena Knezevic, Kristina Sariri, Ivica Sovic, Nazif Demoli, Zrinka Tarle

    Composite resin materials shrink during polymerization regardless of curing unit or polymerization program used. However, different polymerization programs lead to different shrinkage percentages. The aim of this study was to evaluate linear polymerization shrinkage for five composite materials polymerized with curing modes of two LED curing units. Bluephase C5 (500 mW/cm2, 20 seconds) and Bluephase C8 (high-power mode-800 mW/cm2, 20 seconds; and soft-start mode-650 mW/cm2 for the first 5 seconds, and 800 mW/cm2 for the next 15 seconds) (both curing units by Vivadent) were used for composite resin photopolymerization. The materials used were two fine-particle hybrid composite resins (Tetric Ceram and Artemis) and a nanohybrid composite (Tetric EvoCeram) of different shades (all by Vivadent). Polymerization shrinkage was recorded during each second of the polymerization process using laser interferometry. The results were analyzed by ANOVA, and Tukey post hoc test was used for finding significance levels. The highest shrinkage values were obtained in the case of composite polymerization using the high polymerization mode of Bluephase C8 curing unit (0.61% for Tetric EvoCeram A1 and A3 and 0.69% for Artemis A2), while the lowest results were observed with the soft-start mode of Bluephase C8 LED (0.48% for Artemis A2, 0.41% for Tetric Ceram A3, and 0.35% for Tetric EvoCeram A3.5) and Bluephase C5 curing unit (0.40% for Tetric Ceram A1 and 0.44% for Tetric EvoCeram A3.5). Artemis A2 showed the greatest overall sample dimension change, regardless of the light-curing source used. The initial expansion was recorded for all composite resins and curing modes during the first 4 to 9 seconds of illumination. Negative consequences of polymerization shrinkage and temperature rise can be diminished by applying a polymerization program with lower initial light intensity, which prolongs the pregel phase of the polymerization process.


  • Sensitivity increase in digital holographic interferometry

    by Nazif Demoli, Kristina Šariri, Ivica Sović, Marc Torzynski, Hanan Halaq, Dalibor Vukičević

    When using the interferometric techniques, the optical path changes induce the wavefront deformations that in turn cause the appearance of fringes. One general characteristic of such an approach is the measurement sensitivity. The actual sensitivity of a holographic interferometer is a function of, on one hand, the parameters of the measuring system (such as the wavelength of the light used) and, on the other hand, the environmental conditions in which the measurements are being made. The later depend predominately on statistical fluctuations inherent to the particular laboratory conditions. In many applications the sensitivity is near the limits of the deformation detectability. In such cases, it is of vital interest to increase the number of interferometric fringes thus improving the quality of the acquired data. In this paper, we give an overview of the sensitivity increase through various experimental and numerical approaches. We also present a new numerical iterative method in which every cycle doubles the number of interferometric fringes. The method has shown to be especially useful in applications with sub-wavelength wavefront deformations.