Eugenio Marinetto
Research Subjects
Eugenio Marinetto has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Desco
Universidad Carlos III de Madrid
6 shared publications - Javier Pascau
Departamento de Bioingeniería, Universidad Carlos III de Madrid, Leganés, Spain
5 shared publications J. A. Santos-Miranda
Hospital General Universitario Gregorio Marañón
2 shared publications- Juan Felipe Perez Juste Abascal
Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206 Lyon, France
2 shared publications M. Valdivieso
Gmv innovating solutions
2 shared publications- Verónica García-Vázquez
Centro de Investigación Biomédica en Red de Salud Mental (CIBERSAM)
2 shared publications
Latest Publications
- 28 May 2015
- Published by Wiley in Human Brain Mapping
- Vol. 36 (8) , 3227-3245
Reproducibility of brain-cognition relationships using three cortical surface-based protocols: An exhaustive analysis based on cortical thickness
People differ in their cognitive functioning. This variability has been exhaustively examined at the behavioral, neural and genetic level to uncover the mechanisms by which some individuals are more cognitively efficient than others. Studies investigating the neural underpinnings of interindividual differences in cognition aim to establish a reliable nexus between functional/structural properties of a given brain network and higher order cognitive performance. However, these studies have produced inconsistent results, which might be partly attributed to methodological variations. In the current study, 82 healthy young participants underwent MRI scanning and completed a comprehensive cognitive battery including measurements of fluid, crystallized, and spatial intelligence, along with working memory capacity/executive updating, controlled attention, and processing speed. The cognitive scores were obtained by confirmatory factor analyses. T1‐weighted images were processed using three different surface‐based morphometry (SBM) pipelines, varying in their degree of user intervention, for obtaining measures of cortical thickness (CT) across the brain surface. Distribution and variability of CT and CT‐cognition relationships were systematically compared across pipelines and between two cognitively/demographically matched samples to overcome potential sources of variability affecting the reproducibility of findings. We demonstrated that estimation of CT was not consistent across methods. In addition, among SBM methods, there was considerable variation in the spatial pattern of CT‐cognition relationships. Finally, within each SBM method, results did not replicate in matched subsamples. Hum Brain Mapp 36:3227–3245, 2015.
- 28 May 2015
- Published by Wiley in Human Brain Mapping
- Vol. 36 (8) , 3227-3245
Reproducibility of brain-cognition relationships using three cortical surface-based protocols: An exhaustive analysis based on cortical thickness
People differ in their cognitive functioning. This variability has been exhaustively examined at the behavioral, neural and genetic level to uncover the mechanisms by which some individuals are more cognitively efficient than others. Studies investigating the neural underpinnings of interindividual differences in cognition aim to establish a reliable nexus between functional/structural properties of a given brain network and higher order cognitive performance. However, these studies have produced inconsistent results, which might be partly attributed to methodological variations. In the current study, 82 healthy young participants underwent MRI scanning and completed a comprehensive cognitive battery including measurements of fluid, crystallized, and spatial intelligence, along with working memory capacity/executive updating, controlled attention, and processing speed. The cognitive scores were obtained by confirmatory factor analyses. T1‐weighted images were processed using three different surface‐based morphometry (SBM) pipelines, varying in their degree of user intervention, for obtaining measures of cortical thickness (CT) across the brain surface. Distribution and variability of CT and CT‐cognition relationships were systematically compared across pipelines and between two cognitively/demographically matched samples to overcome potential sources of variability affecting the reproducibility of findings. We demonstrated that estimation of CT was not consistent across methods. In addition, among SBM methods, there was considerable variation in the spatial pattern of CT‐cognition relationships. Finally, within each SBM method, results did not replicate in matched subsamples. Hum Brain Mapp 36:3227–3245, 2015.
- Open Access
- 28 October 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (10) , e110594
Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies
Compressed sensing (CS) has been widely applied to prospective cardiac cine MRI. The aim of this work is to study the benefits obtained by including motion estimation in the CS framework for small-animal retrospective cardiac cine. We propose a novel B-spline-based compressed sensing method (SPLICS) that includes motion estimation and generalizes previous spatiotemporal total variation (ST-TV) methods by taking into account motion between frames. In addition, we assess the effect of an optimum weighting between spatial and temporal sparsity to further improve results. Both methods were implemented using the efficient Split Bregman methodology and were evaluated on rat data comparing animals with myocardial infarction with controls for several acceleration factors. ST-TV with optimum selection of the weighting sparsity parameter led to results similar to those of SPLICS; ST-TV with large relative temporal sparsity led to temporal blurring effects. However, SPLICS always properly corrected temporal blurring, independently of the weighting parameter. At acceleration factors of 15, SPLICS did not distort temporal intensity information but led to some artefacts and slight over-smoothing. At an acceleration factor of 7, images were reconstructed without significant loss of quality. We have validated SPLICS for retrospective cardiac cine in small animal, achieving high acceleration factors. In addition, we have shown that motion modelling may not be essential for retrospective cine and that similar results can be obtained by using ST-TV provided that an optimum selection of the spatiotemporal sparsity weighting parameter is performed.
- 28 October 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (10) , e110594
Open AccessComparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies
Compressed sensing (CS) has been widely applied to prospective cardiac cine MRI. The aim of this work is to study the benefits obtained by including motion estimation in the CS framework for small-animal retrospective cardiac cine. We propose a novel B-spline-based compressed sensing method (SPLICS) that includes motion estimation and generalizes previous spatiotemporal total variation (ST-TV) methods by taking into account motion between frames. In addition, we assess the effect of an optimum weighting between spatial and temporal sparsity to further improve results. Both methods were implemented using the efficient Split Bregman methodology and were evaluated on rat data comparing animals with myocardial infarction with controls for several acceleration factors. ST-TV with optimum selection of the weighting sparsity parameter led to results similar to those of SPLICS; ST-TV with large relative temporal sparsity led to temporal blurring effects. However, SPLICS always properly corrected temporal blurring, independently of the weighting parameter. At acceleration factors of 15, SPLICS did not distort temporal intensity information but led to some artefacts and slight over-smoothing. At an acceleration factor of 7, images were reconstructed without significant loss of quality. We have validated SPLICS for retrospective cardiac cine in small animal, achieving high acceleration factors. In addition, we have shown that motion modelling may not be essential for retrospective cine and that similar results can be obtained by using ST-TV provided that an optimum selection of the spatiotemporal sparsity weighting parameter is performed.
- 1 January 2014
- Published by Springer Nature
- p. 344-347
Semi-automatic Segmentation of Sacrum in Computer Tomography Studies for Intraoperative Radiation Therapy
- 1 January 2014
- Published by Springer Nature
- p. 344-347
Semi-automatic Segmentation of Sacrum in Computer Tomography Studies for Intraoperative Radiation Therapy
- 1 January 2014
- Published by Springer Nature
- p. 233-236
A Prior-Based Image Variation (PRIVA) Approach Applied to Motion-Based Compressed Sensing Cardiac Cine MRI
- 1 January 2014
- Published by Springer Nature
- p. 233-236
A Prior-Based Image Variation (PRIVA) Approach Applied to Motion-Based Compressed Sensing Cardiac Cine MRI
- 1 January 2014
- Published by Springer Nature
- p. 37-40
Optical Tracking System Integration into IORT Treatment Planning System
- 1 January 2014
- Published by Springer Nature
- p. 37-40
Optical Tracking System Integration into IORT Treatment Planning System
- 4 December 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (24) , 8769-8782
Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios
Intra-operative electron radiation therapy (IOERT) combines surgery and ionizing radiation applied directly to an exposed unresected tumour mass or to a post-resection tumour bed. The radiation is collimated and conducted by a specific applicator docked to the linear accelerator. The dose distribution in tissues to be irradiated and in organs at risk can be planned through a pre-operative computed tomography (CT) study. However, surgical retraction of structures and resection of a tumour affecting normal tissues significantly modify the patient's geometry. Therefore, the treatment parameters (applicator dimension, pose (position and orientation), bevel angle, and beam energy) may require the original IOERT treatment plan to be modified depending on the actual surgical scenario. We propose the use of a multi-camera optical tracking system to reliably record the actual pose of the IOERT applicator in relation to the patient's anatomy in an environment prone to occlusion problems. This information can be integrated in the radio-surgical treatment planning system in order to generate a real-time accurate description of the IOERT scenario. We assessed the accuracy of the applicator pose by performing a phantom-based study that resembled three real clinical IOERT scenarios. The error obtained (2 mm) was below the acceptance threshold for external radiotherapy practice, thus encouraging future implementation of this approach in real clinical IOERT scenarios.
- 4 December 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (24) , 8769-8782
Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios
Intra-operative electron radiation therapy (IOERT) combines surgery and ionizing radiation applied directly to an exposed unresected tumour mass or to a post-resection tumour bed. The radiation is collimated and conducted by a specific applicator docked to the linear accelerator. The dose distribution in tissues to be irradiated and in organs at risk can be planned through a pre-operative computed tomography (CT) study. However, surgical retraction of structures and resection of a tumour affecting normal tissues significantly modify the patient's geometry. Therefore, the treatment parameters (applicator dimension, pose (position and orientation), bevel angle, and beam energy) may require the original IOERT treatment plan to be modified depending on the actual surgical scenario. We propose the use of a multi-camera optical tracking system to reliably record the actual pose of the IOERT applicator in relation to the patient's anatomy in an environment prone to occlusion problems. This information can be integrated in the radio-surgical treatment planning system in order to generate a real-time accurate description of the IOERT scenario. We assessed the accuracy of the applicator pose by performing a phantom-based study that resembled three real clinical IOERT scenarios. The error obtained (2 mm) was below the acceptance threshold for external radiotherapy practice, thus encouraging future implementation of this approach in real clinical IOERT scenarios.
- 1 August 2011
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 156 (1) , 350-359
Mobile phone platform as portable chemical analyzer
- 1 August 2011
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 156 (1) , 350-359
Mobile phone platform as portable chemical analyzer