Michael P. Dion
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael P. Dion has a total of 156 co-authors. Here are the top co-authors by number of shared publications:
Seunghee Son
6 shared publicationsKaren Hogue
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
5 shared publicationsMartin Liezers
Pacific Northwest National Laboratory
5 shared publicationsBrian W. Miller
Pacific Northwest National Laboratory
4 shared publicationsGregory C. Eiden
Pacific Northwest National Laboratory, Richland, USA
4 shared publicationsLogan Scott
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
4 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Measurement of a lepton–lepton electroweak reaction (MOLLER) spectrometer magnet—Magnetic field measurement and analysis at Jefferson lab
The Thomas Jefferson National Accelerator Facility has developed a specialized spectrometer system for the MOLLER (Measurement Of a Lepton Lepton Electroweak Reaction) experiment, which is designed to probe weak interactions between electrons using 12 GeV electron LINAC. Scheduled to operate over a three-year period, the experiment relies on five water-cooled toroidal magnets—each with seven-fold symmetry and unique geometry—engineered to focus scattered particles. These magnets generate the magnetic field necessary to separate Moller-scattered electrons from elastically scattered protons within the liquid hydrogen target. To meet physics requirements for the experiment, the field in the bore of each magnet must be low enough to not interfere with the scattered protons and generate unwanted backgrounds downstream. This paper presents an engineering-focused evaluation of the magnetic field mapping process, comparing the measured fields with the design specifications and the simulated fields in the bore. The resulting field maps are intended for use in GEANT4 simulations, where precision is critical due to the challenges of low-field measurements. The field analysis will quantify the differences between the ideal and measured magnetic fields. The final field-mapping data will then be used to verify how well the original engineering assumptions performed in generating field inputs for “ee and ep” tracking simulations.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Measurement of a lepton–lepton electroweak reaction (MOLLER) spectrometer magnet—Magnetic field measurement and analysis at Jefferson lab
The Thomas Jefferson National Accelerator Facility has developed a specialized spectrometer system for the MOLLER (Measurement Of a Lepton Lepton Electroweak Reaction) experiment, which is designed to probe weak interactions between electrons using 12 GeV electron LINAC. Scheduled to operate over a three-year period, the experiment relies on five water-cooled toroidal magnets—each with seven-fold symmetry and unique geometry—engineered to focus scattered particles. These magnets generate the magnetic field necessary to separate Moller-scattered electrons from elastically scattered protons within the liquid hydrogen target. To meet physics requirements for the experiment, the field in the bore of each magnet must be low enough to not interfere with the scattered protons and generate unwanted backgrounds downstream. This paper presents an engineering-focused evaluation of the magnetic field mapping process, comparing the measured fields with the design specifications and the simulated fields in the bore. The resulting field maps are intended for use in GEANT4 simulations, where precision is critical due to the challenges of low-field measurements. The field analysis will quantify the differences between the ideal and measured magnetic fields. The final field-mapping data will then be used to verify how well the original engineering assumptions performed in generating field inputs for “ee and ep” tracking simulations.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Assembly of the MOLLER Toroidal Magnets at Jefferson Lab
The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. This paper presents the assembly process for these five toroidal magnets, detailing critical steps including pin insertion, epoxy application, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Assembly of the MOLLER Toroidal Magnets at Jefferson Lab
The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. This paper presents the assembly process for these five toroidal magnets, detailing critical steps including pin insertion, epoxy application, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The “Measurement of Lepton-Lepton Electroweak Reaction” (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. The magnetic field generated by the Spectrometer is needed to separate the incident beam electrons that scatter from target electrons (Moller scattering) from the protons due to elastic e-p scattering within a liquid hydrogen target. This paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The “Measurement of Lepton-Lepton Electroweak Reaction” (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. The magnetic field generated by the Spectrometer is needed to separate the incident beam electrons that scatter from target electrons (Moller scattering) from the protons due to elastic e-p scattering within a liquid hydrogen target. This paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 869-875
MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature
The aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the MOLLER experiment in experimental Hall A at Jefferson Lab. In this paper, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the Short-Beam Shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma-rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well suited for electrical insulation of MOLLER magnets.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 869-875
MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature
The aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the MOLLER experiment in experimental Hall A at Jefferson Lab. In this paper, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the Short-Beam Shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma-rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well suited for electrical insulation of MOLLER magnets.
- 29 August 2023
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 270, 107281
Short-lived noble gas effluent trends from a research reactor
- 29 August 2023
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 270, 107281
Short-lived noble gas effluent trends from a research reactor
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1357-1361
CLLBC High Temperature Scintillation Characterization and Detector Integration
High temperature detectors are required for nuclear material accounting measurements for some advanced reactor designs including molten salt reactors. The Cs 2 LiLa(Br,Cl) 6 :Ce (CLLBC) scintillator is a dual-mode scintillator that shows excellent gamma detection along with the capability to discriminate gamma-rays from neutrons and is available as a commercial product from RMD. The energy resolution at room temperature (RT) is ~3.0% at 662 keV with a light yield of ~45,000 ph/MeV. The gamma-neutron pulse shape discrimination figure of merit is ~3.5 at RT. We investigated the gamma and neutron detection performance of CLLBC scintillators from 25°C to 200°C. The results showed a good light yield response for gamma events as a function of temperature while the light yield for neutron-capture events monotonically decreased from 100% to 76% at 200°C. When integrated with a high temperature photomultiplier, at 175°C we obtained energy resolutions of 7.8% for 662 keV gammas and 4.2% for neutron-capture events, together with a PSD FOM of 0.74.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1357-1361
CLLBC High Temperature Scintillation Characterization and Detector Integration
High temperature detectors are required for nuclear material accounting measurements for some advanced reactor designs including molten salt reactors. The Cs 2 LiLa(Br,Cl) 6 :Ce (CLLBC) scintillator is a dual-mode scintillator that shows excellent gamma detection along with the capability to discriminate gamma-rays from neutrons and is available as a commercial product from RMD. The energy resolution at room temperature (RT) is ~3.0% at 662 keV with a light yield of ~45,000 ph/MeV. The gamma-neutron pulse shape discrimination figure of merit is ~3.5 at RT. We investigated the gamma and neutron detection performance of CLLBC scintillators from 25°C to 200°C. The results showed a good light yield response for gamma events as a function of temperature while the light yield for neutron-capture events monotonically decreased from 100% to 76% at 200°C. When integrated with a high temperature photomultiplier, at 175°C we obtained energy resolutions of 7.8% for 662 keV gammas and 4.2% for neutron-capture events, together with a PSD FOM of 0.74.
- 16 October 2022
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 255, 107037
Source Term Analysis of Xenon (STAX): An effort focused on differentiating man-made isotope production from nuclear explosions via stack monitoring
- 16 October 2022
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 255, 107037
Source Term Analysis of Xenon (STAX): An effort focused on differentiating man-made isotope production from nuclear explosions via stack monitoring
- Open Access
- 1 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Domestic MC&A Recommendations for Liquid-Fueled MSRs
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessDomestic MC&A Recommendations for Liquid-Fueled MSRs
The U.S. Department of Energy's Office of Scientific and Technical Information
- 28 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1212-1224
Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification
A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. For 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.
- 28 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (6) , 1212-1224
Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification
A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. For 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.