Jan Nissinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jan Nissinen has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Ilkka Nissinen
Circuits and Systems Research Unit, UNIVERSITY OF OULU, Oulu, Finland
28 shared publications Juha Kostamovaara
Circuits and Systems Research Unit, University of Oulu, P.O.Box 4500,University of Oulu, 90014, Finland
17 shared publicationsJ. Kostamovaara
University of Oulu, Circuits and Systems Research Unit, Oulu, Finland
11 shared publications- Tuomo Talala
Circuits and Systems Research Unit, UNIVERSITY OF OULU, Oulu, Finland
5 shared publications - Pekka Keranen
Circuits and Systems Research Unit, UNIVERSITY OF OULU, Oulu, Finland
4 shared publications - Alberto Dalla Mora
Politecnico di Milano
3 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Springer Nature in Journal of Signal Processing Systems
- Vol. 98 (2) , 43
Time-resolved Single-photon Counting IC for Flash Raman Imaging and Single-point Depth Imaging
The work presents the design and post-layout simulations of a 260 × 8 time-resolved single-photon counting (TRSPC) CMOS Single Photon Avalanche Diode (SPAD) sensor, currently under fabrication, with integrated 68 ps-resolution, 2.1 ns dynamic-range time-to-digital converters (TDC). The sensor supports multi-point flash Raman imaging and single-point depth imaging (SPDI). In multi-point mode, spatial information from ten sample locations is mapped into the time-domain using optical fibers of incrementally increasing lengths, each adding an additional 30 ns delay. By resolving these ten time windows on-chip, the sensor allows the entire SPAD array to be reused across all measurement points without sacrificing sensor area. In SPDI mode, a 68 ps time window is digitally selected and photon hits are accumulated within that window. The window is then shifted to the next 68 ps bin to perform digital depth sweeping. Delay elements are stabilized by a Delay Locked Loop (DLL) to maintain consistent timing over process, voltage, and temperature variations. Post-layout simulations validate SPDI functionality, characterize the timing performance of 68 ps and 1.4 ns delay elements, D flip-flop (DFF) behavior in the setup/hold violation region, and assess delay variation in the buffer-tree. The DFF analysis shows a 2.45 ps standard deviation in Cumulative Distribution Function (CDF) -derived timing error, while buffer-tree delay differences from middle to extreme channels range from 8.5–19.2 ps. The integrated TDCs enable digital time gating to reduce fluorescence and improve SNR. Overall, the sensor supports 10-point simultaneous measurement and digital depth sweeping with full-array reuse, while being scalable to larger arrays for real-time Raman imaging.
- 21 September 2026
- Published by Springer Nature in Journal of Signal Processing Systems
- Vol. 98 (2) , 43
Open AccessTime-resolved Single-photon Counting IC for Flash Raman Imaging and Single-point Depth Imaging
The work presents the design and post-layout simulations of a 260 × 8 time-resolved single-photon counting (TRSPC) CMOS Single Photon Avalanche Diode (SPAD) sensor, currently under fabrication, with integrated 68 ps-resolution, 2.1 ns dynamic-range time-to-digital converters (TDC). The sensor supports multi-point flash Raman imaging and single-point depth imaging (SPDI). In multi-point mode, spatial information from ten sample locations is mapped into the time-domain using optical fibers of incrementally increasing lengths, each adding an additional 30 ns delay. By resolving these ten time windows on-chip, the sensor allows the entire SPAD array to be reused across all measurement points without sacrificing sensor area. In SPDI mode, a 68 ps time window is digitally selected and photon hits are accumulated within that window. The window is then shifted to the next 68 ps bin to perform digital depth sweeping. Delay elements are stabilized by a Delay Locked Loop (DLL) to maintain consistent timing over process, voltage, and temperature variations. Post-layout simulations validate SPDI functionality, characterize the timing performance of 68 ps and 1.4 ns delay elements, D flip-flop (DFF) behavior in the setup/hold violation region, and assess delay variation in the buffer-tree. The DFF analysis shows a 2.45 ps standard deviation in Cumulative Distribution Function (CDF) -derived timing error, while buffer-tree delay differences from middle to extreme channels range from 8.5–19.2 ps. The integrated TDCs enable digital time gating to reduce fluorescence and improve SNR. Overall, the sensor supports 10-point simultaneous measurement and digital depth sweeping with full-array reuse, while being scalable to larger arrays for real-time Raman imaging.
- 1 January 2026
- Published by Optica Publishing Group
- p. OM1D.2
CMOS Integrated Circuits with Single-Photon Avalanche Diode (SPAD) Arrays for Time-Domain Diffuse Optics and Raman Spectroscopy
SPAD arrays, multichannel time-to-digital converters and laser diode drivers fabricated in CMOS integrated circuit technologies are presented to pave the way to fabricate portable and wearable devices for time-domain diffuse optics and Raman spectroscopy applications.
- 1 January 2026
- Published by Optica Publishing Group
- p. OM1D.2
CMOS Integrated Circuits with Single-Photon Avalanche Diode (SPAD) Arrays for Time-Domain Diffuse Optics and Raman Spectroscopy
SPAD arrays, multichannel time-to-digital converters and laser diode drivers fabricated in CMOS integrated circuit technologies are presented to pave the way to fabricate portable and wearable devices for time-domain diffuse optics and Raman spectroscopy applications.
- Open Access
- 14 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (9) , 1-4
Utilization of Programmable I/O of RP2350 Microcontroller With CMOS SPAD Sensors
A large amount of data produced by single-photon avalanche diode arrays is a well-known challenge, which is commonly resolved with a high-speed custom interface on a field-programmable gate array (FPGA). In this letter, we present a custom interface utilizing programmable I/O blocks of Raspberry Pi RP2350 microcontroller and show that RP2350 can replace FPGAs in some use cases. Only one of the three programmable I/O blocks on RP2350 and about 40 lines of assembly code were enough to handle 21 time-deterministic signals between RP2350 microcontroller and an optical transceiver. Most importantly, the implemented interface achieves data transfer from the transceiver to RP2350 at 900 Mb/s without loading the main processor of RP2350. The operation of the interface was demonstrated by measuring a photoplethysmogram from a fingertip at 500-Hz sample rate. During the measurement, the power consumption of RP2350 was 110 mW, which was less than a third of the system's total power consumption.
- 14 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (9) , 1-4
Open AccessUtilization of Programmable I/O of RP2350 Microcontroller With CMOS SPAD Sensors
A large amount of data produced by single-photon avalanche diode arrays is a well-known challenge, which is commonly resolved with a high-speed custom interface on a field-programmable gate array (FPGA). In this letter, we present a custom interface utilizing programmable I/O blocks of Raspberry Pi RP2350 microcontroller and show that RP2350 can replace FPGAs in some use cases. Only one of the three programmable I/O blocks on RP2350 and about 40 lines of assembly code were enough to handle 21 time-deterministic signals between RP2350 microcontroller and an optical transceiver. Most importantly, the implemented interface achieves data transfer from the transceiver to RP2350 at 900 Mb/s without loading the main processor of RP2350. The operation of the interface was demonstrated by measuring a photoplethysmogram from a fingertip at 500-Hz sample rate. During the measurement, the power consumption of RP2350 was 110 mW, which was less than a third of the system's total power consumption.
- Open Access
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 38912-38921
Compact Time-Domain Diffuse Optics System Based on CMOS Technologies for Fast Acquisitions of Heartbeat-Induced Absorption Changes
This work introduces a novel compact Time-Domain Diffuse Optics (TD-DO) system based on CMOS integrated circuits for being potentially used in non-invasive tissue characterization and physiological monitoring. The system incorporates a ~800 nm emitting laser diode and a 256-channel Single-Photon Avalanche Diode (SPAD) line sensor, offering high-throughput data acquisition. It offers remarkable capabilities for non-invasive investigations of diffusive media for biological and non-biological applications. To enhance system performance, an alignment method of the TD curves based on cross-correlation maximization is proposed and validated under internationally agreed protocols, such as MEDPHOT and nEUROPt. Finally, fast oscillations in optical properties corresponding to the heartbeat have been detected, showcasing the potential of the system for real-time physiological tracking. The results display the potential of the proposed compact TD-DO system, paving the way for the implementation of wearable instruments capable of non-invasively tracking fast physiological dynamics with high accuracy and robustness.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 38912-38921
Open AccessCompact Time-Domain Diffuse Optics System Based on CMOS Technologies for Fast Acquisitions of Heartbeat-Induced Absorption Changes
This work introduces a novel compact Time-Domain Diffuse Optics (TD-DO) system based on CMOS integrated circuits for being potentially used in non-invasive tissue characterization and physiological monitoring. The system incorporates a ~800 nm emitting laser diode and a 256-channel Single-Photon Avalanche Diode (SPAD) line sensor, offering high-throughput data acquisition. It offers remarkable capabilities for non-invasive investigations of diffusive media for biological and non-biological applications. To enhance system performance, an alignment method of the TD curves based on cross-correlation maximization is proposed and validated under internationally agreed protocols, such as MEDPHOT and nEUROPt. Finally, fast oscillations in optical properties corresponding to the heartbeat have been detected, showcasing the potential of the system for real-time physiological tracking. The results display the potential of the proposed compact TD-DO system, paving the way for the implementation of wearable instruments capable of non-invasively tracking fast physiological dynamics with high accuracy and robustness.
- Open Access
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 30 (1: Single-) , 1-11
0.5 Billion Counts per Second Enable High Speed and Penetration in Time-Domain Diffuse Optics
We present the application to time-domain diffuse optics of a high-speed 8×256 array of single-photon avalanche diodes with integrated 256 parallel time-to-digital converters. Thanks to the high light harvesting capability granted by the overall 0.85 mm 2 active area combined with a high throughput ( i.e. , saturated photon counting and timing rate of 512 million of counts per second), it has been possible for the first time to reconstruct histograms of photons time-of-flight in diffusive media using pulsed illumination at photon counting rate of about 450 million of counts per second even using a source-detector distance of 2 cm. This has been achieved both on tissue-mimicking phantoms as well as in-vivo , permitting high accuracy with extremely low acquisition times (down to 5 ms). This approach has been systematically validated on phantoms using established performance assessment protocols in the field of diffuse optics covering both homogeneous (demonstrating high linearity in the recovering of the absorption coefficient) and heterogeneous (demonstrating high penetration inside scattering media) paradigms. Two preliminary in-vivo proof-of-concept applications on healthy volunteer are shown, specifically, the detection of the heartbeat pattern in the brachioradialis muscle during an arterial cuff occlusion and of the same pattern acquired on the forehead during resting state.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 30 (1: Single-) , 1-11
Open Access0.5 Billion Counts per Second Enable High Speed and Penetration in Time-Domain Diffuse Optics
We present the application to time-domain diffuse optics of a high-speed 8×256 array of single-photon avalanche diodes with integrated 256 parallel time-to-digital converters. Thanks to the high light harvesting capability granted by the overall 0.85 mm 2 active area combined with a high throughput ( i.e. , saturated photon counting and timing rate of 512 million of counts per second), it has been possible for the first time to reconstruct histograms of photons time-of-flight in diffusive media using pulsed illumination at photon counting rate of about 450 million of counts per second even using a source-detector distance of 2 cm. This has been achieved both on tissue-mimicking phantoms as well as in-vivo , permitting high accuracy with extremely low acquisition times (down to 5 ms). This approach has been systematically validated on phantoms using established performance assessment protocols in the field of diffuse optics covering both homogeneous (demonstrating high linearity in the recovering of the absorption coefficient) and heterogeneous (demonstrating high penetration inside scattering media) paradigms. Two preliminary in-vivo proof-of-concept applications on healthy volunteer are shown, specifically, the detection of the heartbeat pattern in the brachioradialis muscle during an arterial cuff occlusion and of the same pattern acquired on the forehead during resting state.
- Open Access
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (9) , 4635-4645
On the Spectral Quality of Time-Resolved CMOS SPAD-Based Raman Spectroscopy With High Fluorescence Backgrounds
The fluorescence background in Raman spectroscopy can be effectively suppressed by using pulsed lasers and time-gated detectors. A recent solution to reduce the high complexity and bulkiness of the time-gated systems is to implement the detector by utilizing time-resolved single-photon avalanche diodes (SPADs) fabricated in complementary-metal-oxide-semiconductor (CMOS) technology. In this study, we investigate the effects of fluorescence-to-Raman ratio, recording time and excitation intensity on the quality of Raman spectra measured by using one of the furthest developed fluorescence-suppressed Raman spectrometers based on a time-resolved CMOS SPAD line sensor. The objectives were to provide information on the significance of the different causes behind the distortion of the measured Raman spectra with various measurement conditions and to provide general information on the possibilities to exploit the high-intensity non-stationary pulsed laser excitation to gain additional improvement on the spectral quality due to laser-induced fluorescence saturation. It was shown that the distortion of the spectra with samples having short fluorescence lifetimes (~2 ns) and high fluorescence-to-Raman ratios, i.e. with challenging samples, is dominated by the timing skew of the sensor instead of the shot noise caused by the detected events. In addition, the actual reason for the observed improvement in the spectral quality as a function of excitation intensity was discovered not to be the conventionally thought increased number of detected photons but rather the laser-induced fluorescence saturation. At best, 26% improvement to the signal-to-noise ratio was observed due to fluorescence saturation.
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (9) , 4635-4645
Open AccessOn the Spectral Quality of Time-Resolved CMOS SPAD-Based Raman Spectroscopy With High Fluorescence Backgrounds
The fluorescence background in Raman spectroscopy can be effectively suppressed by using pulsed lasers and time-gated detectors. A recent solution to reduce the high complexity and bulkiness of the time-gated systems is to implement the detector by utilizing time-resolved single-photon avalanche diodes (SPADs) fabricated in complementary-metal-oxide-semiconductor (CMOS) technology. In this study, we investigate the effects of fluorescence-to-Raman ratio, recording time and excitation intensity on the quality of Raman spectra measured by using one of the furthest developed fluorescence-suppressed Raman spectrometers based on a time-resolved CMOS SPAD line sensor. The objectives were to provide information on the significance of the different causes behind the distortion of the measured Raman spectra with various measurement conditions and to provide general information on the possibilities to exploit the high-intensity non-stationary pulsed laser excitation to gain additional improvement on the spectral quality due to laser-induced fluorescence saturation. It was shown that the distortion of the spectra with samples having short fluorescence lifetimes (~2 ns) and high fluorescence-to-Raman ratios, i.e. with challenging samples, is dominated by the timing skew of the sensor instead of the shot noise caused by the detected events. In addition, the actual reason for the observed improvement in the spectral quality as a function of excitation intensity was discovered not to be the conventionally thought increased number of detected photons but rather the laser-induced fluorescence saturation. At best, 26% improvement to the signal-to-noise ratio was observed due to fluorescence saturation.
- Open Access
- 25 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (16) , 6711-6720
Depth Analysis of Semi-Transparent Media by a Time-Correlated CMOS SPAD Line Sensor-Based Depth-Resolving Raman Spectrometer
Raman spectroscopy has proved to have potential in deep surface analytical applications. We present here, to the best of our knowledge, the first time depth analysis of semi-transparent media by a depth-resolving Raman spectrometer based on an adjustable time-correlated CMOS SPAD (single-photon avalanche diode) line sensor that can measure the depth of target samples embedded in a centimeter-scale semi-transparent medium simultaneously with a normal Raman depth profiling operation and suppress the fluorescence background by means of adjustable picosecond time gating. The variability of the depth derivation was measured to be ± 0.43 cm at depths ranging from 2 cm to 9 cm. In addition, the advantages of the adjustable picosecond time gating in terms of depth derivation and fluorescence background suppression performance were shown by comparing gate widths ranging from 100 ps to 13 ns. We believe that the technology concerned could pave the way for a new kind of compact, practical depth-resolving Raman spectrometer for deep subsurface analytical applications.
- 25 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (16) , 6711-6720
Open AccessDepth Analysis of Semi-Transparent Media by a Time-Correlated CMOS SPAD Line Sensor-Based Depth-Resolving Raman Spectrometer
Raman spectroscopy has proved to have potential in deep surface analytical applications. We present here, to the best of our knowledge, the first time depth analysis of semi-transparent media by a depth-resolving Raman spectrometer based on an adjustable time-correlated CMOS SPAD (single-photon avalanche diode) line sensor that can measure the depth of target samples embedded in a centimeter-scale semi-transparent medium simultaneously with a normal Raman depth profiling operation and suppress the fluorescence background by means of adjustable picosecond time gating. The variability of the depth derivation was measured to be ± 0.43 cm at depths ranging from 2 cm to 9 cm. In addition, the advantages of the adjustable picosecond time gating in terms of depth derivation and fluorescence background suppression performance were shown by comparing gate widths ranging from 100 ps to 13 ns. We believe that the technology concerned could pave the way for a new kind of compact, practical depth-resolving Raman spectrometer for deep subsurface analytical applications.
- Open Access
Distance-Resolving Raman Radar Based on a Time-Correlated CMOS Single-Photon Avalanche Diode Line Sensor
Remote Raman spectroscopy is widely used to detect minerals, explosives and air pollution, for example. One of its main problems, however, is background radiation that is caused by ambient light and sample fluorescence. We present here, to the best of our knowledge, the first time a distance-resolving Raman radar device that is based on an adjustable, time-correlated complementary metal-oxide-semiconductor (CMOS) single-photon avalanche diode line sensor which can measure the location of the target sample simultaneously with the normal stand-off spectrometer operation and suppress the background radiation dramatically by means of sub-nanosecond time gating. A distance resolution of 3.75 cm could be verified simultaneously during normal spectrometer operation and Raman spectra of titanium dioxide were distinguished by this system at distances of 250 cm and 100 cm with illumination intensities of the background of 250 lux and 7600 lux, respectively. In addition, the major Raman peaks of olive oil, which has a fluorescence-to-Raman signal ratio of 33 and a fluorescence lifetime of 2.5 ns, were distinguished at a distance of 30 cm with a 250 lux background illumination intensity. We believe that this kind of time-correlated CMOS single-photon avalanche diode sensor could pave the way for new compact distance-resolving Raman radars for application where distance information within a range of several metres is needed at the same time as a Raman spectrum.
Open AccessDistance-Resolving Raman Radar Based on a Time-Correlated CMOS Single-Photon Avalanche Diode Line Sensor
Remote Raman spectroscopy is widely used to detect minerals, explosives and air pollution, for example. One of its main problems, however, is background radiation that is caused by ambient light and sample fluorescence. We present here, to the best of our knowledge, the first time a distance-resolving Raman radar device that is based on an adjustable, time-correlated complementary metal-oxide-semiconductor (CMOS) single-photon avalanche diode line sensor which can measure the location of the target sample simultaneously with the normal stand-off spectrometer operation and suppress the background radiation dramatically by means of sub-nanosecond time gating. A distance resolution of 3.75 cm could be verified simultaneously during normal spectrometer operation and Raman spectra of titanium dioxide were distinguished by this system at distances of 250 cm and 100 cm with illumination intensities of the background of 250 lux and 7600 lux, respectively. In addition, the major Raman peaks of olive oil, which has a fluorescence-to-Raman signal ratio of 33 and a fluorescence lifetime of 2.5 ns, were distinguished at a distance of 30 cm with a 250 lux background illumination intensity. We believe that this kind of time-correlated CMOS single-photon avalanche diode sensor could pave the way for new compact distance-resolving Raman radars for application where distance information within a range of several metres is needed at the same time as a Raman spectrum.
- Open Access
- 8 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (9) , 3789-3798
A $16\times256$ SPAD Line Detector With a 50-ps, 3-bit, 256-Channel Time-to-Digital Converter for Raman SpectroscopyA 16×256 element single-photon avalanche diode (SPAD) array with a 256-channel, 3-bit on-chip time-to-digital converter (TDC) has been developed for fluorescence-suppressed Raman spectroscopy. The circuit is fabricated in 0.35 μm highvoltage CMOS technology and it allows a measurement rate of 400 kframe/s. In order to be able to separate the Raman and fluorescence photons even in the presence of the unavoidable timing skew of the timing signals of the TDC, the time-of-arrival of every detected photon is recorded with high time resolution at each spectral point with respect to the emitted short and intensive laser pulse (~150ps). The dynamic range of the TDC is set so that no Raman photon is lost due to the timing skew, and thus the complete time history of the detected photons is available at each spectral point. The resolution of the TDC was designed to be adjustable from 50 ps to 100 ps. The error caused by the timing skew and the residual variation in the resolution of the TDC along the spectral points is mitigated utilizing a calibration measurement from reference sample with known smooth fluorescence spectrum. As a proof of concept, the Raman spectrum of sesame seed oil, having a high fluorescence-to-Raman ratio and a short fluorescence lifetime of 1.9 ns, was successfully recorded.
- 8 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (9) , 3789-3798
Open AccessA $16\times256$ SPAD Line Detector With a 50-ps, 3-bit, 256-Channel Time-to-Digital Converter for Raman SpectroscopyA 16×256 element single-photon avalanche diode (SPAD) array with a 256-channel, 3-bit on-chip time-to-digital converter (TDC) has been developed for fluorescence-suppressed Raman spectroscopy. The circuit is fabricated in 0.35 μm highvoltage CMOS technology and it allows a measurement rate of 400 kframe/s. In order to be able to separate the Raman and fluorescence photons even in the presence of the unavoidable timing skew of the timing signals of the TDC, the time-of-arrival of every detected photon is recorded with high time resolution at each spectral point with respect to the emitted short and intensive laser pulse (~150ps). The dynamic range of the TDC is set so that no Raman photon is lost due to the timing skew, and thus the complete time history of the detected photons is available at each spectral point. The resolution of the TDC was designed to be adjustable from 50 ps to 100 ps. The error caused by the timing skew and the residual variation in the resolution of the TDC along the spectral points is mitigated utilizing a calibration measurement from reference sample with known smooth fluorescence spectrum. As a proof of concept, the Raman spectrum of sesame seed oil, having a high fluorescence-to-Raman ratio and a short fluorescence lifetime of 1.9 ns, was successfully recorded.
- Open Access
- 1 March 2018
- Published by Elsevier in Microchemical Journal
- Vol. 137, 342-347
Evaluation of time-gated Raman spectroscopy for the determination of nitric, sulfuric and hydrofluoric acid concentrations in pickle liquor
- 1 March 2018
- Published by Elsevier in Microchemical Journal
- Vol. 137, 342-347
Open AccessEvaluation of time-gated Raman spectroscopy for the determination of nitric, sulfuric and hydrofluoric acid concentrations in pickle liquor