  • Perspective: On the discontinuity between the scale realizations VPDB2020 and VPDB2006 – The underestimated role of measurement uncertainties?

    by Sergey Assonov

    Several recent publications have discussed the discontinuity between the δ 13 C scale realization VPDB2020 (new IAEA carbonate reference materials (RMs) IAEA‐610/611/612) and the LSVEC‐traceable realization named as VPDB2006 (organic RMs normalized to LSVEC in 2006, and USGS44 with its δ 13 C based on those RMs and LSVEC). This looks like an unsolvable puzzle. The question from practical users is as follows: do we want to be correct, that is, use VPDB2020, or be compatible with the results obtained in previous years, that is, use VPDB2006? In metrology, the significance of any discrepancy is considered in terms of the associated combined uncertainty. Uncertainties estimated for VPDB2020 according to the metrological approaches are much lower than the discontinuity. However, the situation for VPDB2006 is unclear. By reviewing publications related to LSVEC and LSVEC‐normalized organic RMs of 2006, several missing and/or underestimated uncertainty components can be identified. When these missing or underestimated uncertainties are taken together, the discontinuity at negative δ 13 C appears to be the same as or similar to the combined underestimated uncertainties for VPDB2006.


  • Exploring δ 13 C data compatibility in a broad δ 13 C range: Reassembling δ 13 C values obtained for NIST CO 2 RMs 8562–8564 at different laboratories

    by Sergey Assonov

    Rationale: Stable isotope datasets obtained in different laboratories over years must be compared and combined. The strict compatibility in δ 13 C at ±0.01‰ and ±0.02‰, k = 1, respectively, is required for observations of greenhouse gases CO 2 and methane. That implies the long‐term compatibility of calibrations realized at different laboratories. Thus far, this level of compatibility has not been demonstrated for pure CO 2 in a broad δ 13 C range and over years. Methods: We reassemble the δ 13 C obtained in different laboratories for NIST CO 2 RMs 8562–8564, which are pure CO 2 gases. If the measurements are based on independent calibrations and reported on the same 17 O correction framework, δ 13 C of all three RMs can be used to estimate the long‐term δ 13 C data compatibility. Results: δ 13 C values obtained in different laboratories for NIST CO 2 RMs 8562–8564 (a range of δ 13 C from ~ −3.7‰ to ~ −41.6‰) from 1998 to 2020 agree within their uncertainties. Two NIST studies (1999 and 2004) have combined data from several laboratories using different Isotope ratio mass spectrometry (IRMS) methods and somewhat different approaches. Three single‐laboratory studies (2003, 2008, and 2020) have used the same type of IRMS and similar approaches. The δ 13 C values from these laboratories agree within ±0.01‰, k = 1, over the entire δ 13 C range and have uncertainties about two times lower than those obtained at NIST by combining data from several laboratories. Conclusion: The δ 13 C values for NIST CO 2 RMs 8562–8564 obtained in three laboratories using the same IRMS (2003, 2008, and 2020) agree within ±0.01‰, k = 1. First, this confirms the long‐term stability in δ 13 C of RMs 8562–8564. Second, this example of compatibility in δ 13 C calibrations on pure CO 2 , from −3.7‰ to −41.6‰, is relevant to stable isotope measurements of greenhouse gases CO 2 and methane. Third, this confirms the high accuracy of the δ 13 C(air–CO 2 ) calibrations performed in 2003 and 2008 for the project Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrumented Container (CARIBIC).


  • Assessment of the accuracy of the 17 O correction algorithm used in δ 13 C determinations by CO 2 mass spectrometry

    by Sergey Assonov

    Rationale: High‐accuracy δ 13 C values are required for observations of greenhouse gases CO 2 and methane, and, consequently, for international reference materials (RMs). Recently, another application, clumped isotope geothermometry of natural carbonates, has demonstrated the requirement for high‐accuracy δ 13 C values. δ 13 C determinations by mass spectrometry use an 17 O isobaric correction on m / z 45, where 17 O abundance is calculated from the measured 18 O with the 17 O– 18 O relationship assumed with λ = 0.528. This relationship is the key assumption of the algorithm proposed in 2003 and accepted by IUPAC in 2010. However, to date, this relationship and potential δ 13 C biases have not been verified using 17 O measurements. Methods: To verify the 17 O correction and to estimate potential δ 13 C biases, we compile measured 17 O data for carbonate RMs, for a range of natural carbonates that are typically analyzed in clumped isotope geothermometry and for CO 2 in isotope equilibrium with natural waters including plants and biota. δ 13 C biases are calculated based on 17 O deviation from the 17 O– 18 O relationship assumed in the 17 O correction. Results: To estimate δ 13 C biases accurately, the VPDB‐CO 2 framework for expressing 17 O excess is defined and linked to the δ 13 C scale definition. δ 13 C biases estimated for carbonate RMs are found within ±0.004‰; the biases estimated for natural carbonates and CO 2 in equilibrium with natural waters are mostly within ±0.010‰ (bidirectional distribution around zero). In all cases, the estimated biases are found within the best instrumental uncertainty of modern isotope ratio mass spectrometry (IRMS) (around ±0.014‰, k = 2). Conclusions: For the first time, high accuracy of δ 13 C data obtained by CO 2 mass spectrometry using the 17 O correction with fixed λ = 0.528 has been demonstrated using measured 17 O data. δ 13 C biases estimated are within the best IRMS precision (±0.014‰, k = 2) and can be neglected in most practical applications. To obtain high‐quality δ 13 C data, it is strictly necessary that all data are treated on the VPDB‐CO 2 scale.


  • A stable isotope toolbox for water and inorganic carbon cycle studies

    by Claude Hillaire-Marcel, Sang-Tae Kim, Amaëlle Landais, Prosenjit Ghosh, Sergey Assonov, Christophe Lécuyer, Marc Blanchard, Harro A. J. Meijer, Hans Christian Steen-Larsen


  • Open Access

    Metrological traceability of measurement results and calibration hierarchy is a prerequisite for improved data compatibility: example of the VPDB scale. 

    by Sergey Assonov

    For stable isotope data sets to be compared or combined in biogeochemical studies, their compatibility must be well understood. For δ13C measurements in greenhouse gases, the WMO GAW program has set compatibility targets of 0.010 ‰ for atmospheric CO2 and 0.020 ‰ for atmospheric methane (in background air studies [1, 2]). The direct comparison of samples between laboratories can provide limited information, such as a snapshot for a specific time period, but combining data sets produced over decades requires more efforts. To produce high quality data, reliable calibrations must be made, mutually consistent values of reference materials (RMs) must be used, and a traceability scheme that ensures low uncertainty must be implemented.The VPDB δ13C scale provides example of approaches developed recently. Several problems with the existing implementation of the VPDB scale have been identified between 2009-2016 [3]: the primary reference material (RM) NBS19 was exhausted and needed to be replaced; the δ13C of LSVEC (used to anchor the VPDB scale at negative δ13C) was found to be drifting and its use as a RM for δ13C was discontinued [4]; other RMs that were available in 2016 (e.g., NBS18) were not able to be used to develop new RMs as their uncertainties were too large. Given that the VPDB scale is artefact-based and not supported by absolute ratio measurements with uncertainty as low as required, the principles of value assignments on the VPDB scale were needed to be revised.To ensure that a revised scheme did not encounter similar problems (with dependence on a single scale-anchor), several fundamental metrological principles were considered: (i) traceability of measurement results to the primary RM, (ii) a hierarchy of calibrators and (iii) comprehensive understanding of measurement method(s) [5]. The revised VPDB scheme [3] was applied to the new primary RM [6] and three RMs covering a large δ13C range (to negative values) [7]. Values were assigned in a mutually consistent way, with uncertainties ranging from 0.010 to 0.015 ‰, depending on the assigned δ13C. Each RM value has an uncertainty assigned that includes all known instrumental corrections, potential alterations due to storage, and inhomogeneity assessment [6,7]. The scheme allows for the δ13C range to be expanded by developing new carbonate RMs, and to be extended to matrix-based RMs.The revised VPDB δ13C scale realization should lead to a robust basis for improving data compatibility. The developed framework can be applied to other measurements of biogeochemical interest, such as small 17O variations (in H2O, carbonates and other samples), clumped isotopes, and various paleoclimate reconstructions. Notably, the traceability principle is helpful in realistic uncertainty estimations which provide a tool to understand constrains and limiting steps in data comparisons.REFERENCES:  [1]. WMO, GAW Report No.229. 2016. [2]. WMO, GAW Report No.242. 2018. [3]. Assonov, S. et al., RCM, 2021. https://doi.org/10.1002/rcm.9018. [4]. IUPAC, Press release of the IUPAC meeting in 2017, https://iupac.org/standard-atomic-weights-of-14-chemical-elements-revised/. [5]. De Bievre, P. et al., PURE APPL CHEM, 2011. 83(10): p. 1873-1935. [6]. Assonov, S., et al., RCM, 2020: p. https://doi.org/10.1002/rcm.8867. [7]. Assonov, S. et al., RCM, 2021. https://doi.org/10.1002/rcm.9014

  • On the metrological traceability and hierarchy of stable isotope reference materials aimed at realisation of the VPDB scale: Revision of the VPDB δ 13 C scale based on multipoint scale‐anchoring RMs

    by Sergey Assonov, Ales Fajgelj, Colin Allison, Manfred Gröning

    Rationale: In recent years, the primary reference material (RM) for the VPDB scale, NBS19, has become unavailable, and the RM used for low‐end scale‐anchoring, LSVEC, was found unsuitable due a drift in the δ 13 C value. Given these problems, new RMs aimed at realising the VPDB δ 13 C scale with low uncertainty were produced. Establishing the consistency of the new RMs with the “old” RMs prompted our revision of the underlying principles of RM value assignments, and the VPDB δ 13 C scale realisation and its long‐term sustainability. Methods: Analysis of major developments of the VPDB scale, a review of the contemporary requirements for RMs, and comparison with well‐established measurement scales have been performed, with the aim of revising the VPDB δ 13 C scale, principles of RM value assignments, and calibrator hierarchy. Requirements for scale‐anchoring RMs with low uncertainty and measures to establish the scale sustainability have been formulated. Results: The revised scale realisation is based on multiple reference points, well‐defined calibration hierarchy and the use of well‐understood methods for value assignment. The realisation scheme includes the new primary RM IAEA‐603 and scale‐anchoring RMs IAEA‐610, IAEA‐611 and IAEA‐612, covering δ 13 C from +2.46 to −36.7 ‰ VPDB, with uncertainties, including inhomogeneity and stability assessment, of less than 0.015 ‰. The values of these four RMs were assigned in a mutually consistent way; agreement between measurements made using this realisation with those made using the VPDB scale of 2006 has been demonstrated on NIST CO 2 RMs 8562–8564. Conclusions: Multipoint‐anchoring of the VPDB δ 13 C scale provides several distinct “points” on the scale as means for cross‐measurements to check the stability and viability of RMs and detect drift of values, if any. This ensures that the δ 13 C scale is suitable for the most demanding applications, and provides options for developing further RMs with high accuracy inside a robust scale realisation scheme.


  • Characterisation of new reference materials IAEA‐610, IAEA‐611 and IAEA‐612 aimed at the VPDB δ 13 C scale realisation with small uncertainty

    by Sergey Assonov, Ales Fajgelj, Jean‐François Hélie, Colin Allison, Manfred Gröning

    Rationale: LSVEC, the second anchor Reference Material (RM) for the VPDB δ 13 C scale realisation, was introduced in 2006. In 2015, its δ 13 C value was found to be drifting and, in 2017, its use as an RM for δ 13 C was officially discontinued by IUPAC. New RMs of low uncertainty are needed. This paper describes the preparation and characterisation of IAEA‐610, IAEA‐611 and IAEA‐612 (calcium carbonate, of chemical origin) which shall serve as a set of RMs aimed at anchoring the VPDB scale at negative δ 13 C values. Methods: The preparation and characterisation of IAEA‐610, IAEA‐611 and IAEA‐612 were performed by addressing the contemporary technical requirements for RM production and characterisation (ISO Guide 35:2017). The three RMs were produced in large quantities, and the first batch was sealed into ampoules (0.5 g) to ensure the integrity of the RM during storage; additional batches were sealed for long‐term storage. The most accurate method of CO 2 preparation and stable isotope measurements was used, namely carbonate‐H 3 PO 4 reaction under well‐controlled conditions combined with well‐tested stable isotope ratio mass spectrometry. Results: The assigned values of δ 13 C and associated uncertainties are based on a large number of analyses (~10 mg aliquots) performed at IAEA and address all the known uncertainty components. For aliquots down to ~100 μg, the δ 13 C uncertainty is increased. The uncertainty components considered are as follows: (i) material homogeneity, (ii) value assignment against IAEA‐603, (iii) potential storage effects, (iv) effect of the 17 O correction, and (v) mass spectrometer linearity and cross‐contamination memory in the ion source. Conclusions: The new RMs IAEA‐610, IAEA‐611 and IAEA‐612 have been characterised on the VPDB δ 13 C scale in a mutually consistent way. The use of three RMs will allow a consistent realisation of the VPDB δ 13 C scale with small uncertainty to be established, and to reach metrological compatibility of measurement results over several decades.


  • Preparation and characterisation of IAEA‐603, a new primary reference material aimed at the VPDB scale realisation for δ 13 C and δ 18 O determination

    by Sergey Assonov, Manfred Groening, Ales Fajgelj, Jean‐Francois Hélie, Claude Hillaire‐Marcel

    Rationale: NBS19 carbonate, a primary reference material (RM) for the Vienna Pee Dee Belemnite (VPDB) scale realisation introduced in 1987, was exhausted in 2009, and no primary RM was available for several years. This study describes the preparation and characterisation of a new RM, IAEA‐603 (Ca‐carbonate, calcite of marble origin), which shall serve as a new primary RM (replacement for NBS19) or primary calibrator aimed at the highest realisation of the VPDB scale for δ 13 C and δ 18 O values, including the VPDB‐CO 2 δ 18 O scale. Methods: IAEA‐603 preparation and characterisation (value transfer) against NBS19 were performed by addressing the major modern technical requirements for the production and characterisation of RMs (ISO Guide 35). IAEA‐603 was produced in a large quantity, and the first batch was sealed into ampoules (0.5 g) to ensure RM integrity during storage; four other batches were sealed for long‐term storage. The most accurate method of CO 2 preparation for isotope mass spectrometry was used, namely carbonate–H 3 PO 4 reaction under controlled conditions. Results: The assigned values of δ 13 C = +2.460 ± 0.010‰ and δ 18 O = −2.370 ± 0.040‰ ( k = 1) are based on a large number of analyses (~10 mg aliquots) performed at IAEA and address all the known uncertainty components. For aliquots down to 120 μg, the δ 18 O uncertainty remains unchanged but shall be doubled for δ 13 C. The uncertainty components considered are as follows: (a) material homogeneity (within and between the 5200 ampoules produced), (b) value assignment against NBS19, (c) storage effects and (d) effect of the 17 O correction. Conclusions: The new primary RM IAEA‐603 replaces NBS19 in its use as the highest calibrator for the VPDB δ 13 C and δ 18 O scale, including the VPDB‐CO 2 δ 18 O scale. The use of IAEA‐603 will allow laboratories worldwide to establish consistent realisation of the scales for δ 13 C and δ 18 O values and metrological comparability of measurement results for decades. The VPDB scale definition based on NBS19 stays valid.


  • Open Access

    Application of lead isotope ratios for pollution source investigation in the marine environment

    by Emiliya Vassileva, Anna Maria Orani, Sergey Assonov

    Lead is a non-essential toxic element that at high levels of human exposure causes damage to many organs of the human body. This element naturally occurs in the Earth crust, but its biogeochemical cycle has been altered by anthropogenic activities, which have introduced high amount of this element from different sources. Among inorganic contaminants, Pb is perhaps the most studied, but the determination of its total concentration only is not sufficient for a proper evaluation of contamination sources. Discrimination of anthropogenic and geogenic lead sources requires both precise and accurate isotope ratio determination as well as high versatility due to the complexity of environmental matrices, such as sediments, biota and seawater. This element has a partially radiogenic isotopic composition with 208Pb, 206Pb and 207Pb originating from the radioactive decay of 238U, 235U and 232Th respectively and 204Pb representing the only natural stable isotope. This characteristic isotopic composition represents a powerful analytical tool as it allows to trace the sources, fate and effects of possible Pb contamination. The most common way to express the Pb isotopic composition is using the ratio 206Pb/207Pb, because of the easy interference-free determination and isotopes’ abundance. The determination of 204Pb by ICP-MS is quite challenging as this is also the least abundant among Pb isotopes (about 1.4%) and it is also affected by isobaric interference from 204Hg. The latter derives from both sample matrices and from plasma/sweep gas supplies and it represents a big analytical challenge, especially for marine biota samples, where the amount of Hg can be up to 100 times higher than Pb. In this work we present the development and the application of analytical methodology for the accurate and precise determination of Pb isotope ratios by HR-ICP-MS in different marine environmental matrices (sediments, seawater and biota). Analytical procedures are involving a separation of Pb from the sample matrix and mercury, present in the sample. For seawater samples, the use of the SeaFAST automated system allowed simultaneous matrix separation and analyte pre-concentration before ICP-MS analysis. A comparison of results for lead isotope ratios obtained with MC-ICP-MS and HR ICP-MS in the same samples, in all cases, showed very good agreement . The total uncertainty associated to each result was estimated and all major contributions to the combined uncertainty of the obtained results were identified. As all such studies involve companions of different datasets, the uncertainty estimation is critical to ensure correct companions.  The developed methodology was applied to different marine samples, namely sediments from Caribbean, Baltic and Namibian coasts, biota samples from French Polynesia, seawater samples from Mediterranean and Arctic seas. 

  • Open Access

    The IAEA carbonate reference materials aimed at the VPDB scale realization with low uncertainty.

    by Sergey Assonov, Ales Fajgelj, Manfred Gröning

    The stable isotope scales of the light elements (H, C, O, S) are artefact-based (related to a primary reference material) and their practical realisation is based on several refence materials (RMs) traceable to the primary RM on a respective delta-scale. NBS19 carbonate, the primary RM for the VPDB scale introduced in 1987, exhausted in 2012, and its replacement was not available for several years. In 2016, IAEA-603 carbonate (replacement for NBS19) was released as the new primary RM having been carefully calibrated versus the remaining NBS19. The IAEA-603 uncertainty in δ13C and δ18O for the first batch (5200 ampoules produced) is ±0.010 ‰ and ±0.040 ‰ respectively (1-sigma level); the homogeneity assessment is the major component of total uncertainty which is limited by the best mass-spectrometer performance and the method (carbonate-acid reaction) reproducibility.In 2015, monitoring of LSVEC (formerly the second scale-anchor on the VPDB scale) detected variable drifts in its δ13C value and therefore the use of LSVEC as RM for δ13C was discontinued. It was recognised that a replacement for LSVEC is needed for normalization of the δ13C measurement results, also to address the strict uncertainty requirements for δ13C observations in atmospheric CO2 and methane (≤0.01 ‰ and ≤0.02 ‰ correspondingly). Similar to IAEA-603, any new RMs will address the technical requirements for RMs laid out by ISO Guide 35: 2017 including (i) RM batch production and batch characterisation; (ii) homogeneity and stability assessment of the final product (RMs sealed off in 0.5 g ampoules) and (iii) value and uncertainty assignment based on the metrological traceability. Three new carbonate RMs are in preparation at the IAEA; the uncertainty in δ13C for all three materials due to RM’ homogeneity is already confirmed at ≤0.01 ‰ (on 10 mg aliquots), which is at the limit of the best modern mass-spectrometers. The isotopic characterisation of these new carbonate RMs is in progress; they should be released in 2020.Together with IAEA-603, the three new RMs will provide a reliable realization of the VPDB scale with the lowest possible uncertainty. With these RMs users can (i) select RMs in a suitable δ13C range, (ii) detect any potential drift of RMs including the behaviour of daily lab-standards and (iii) detect any potential problem in applying the 17O correction at end-user laboratories. In conclusion, these new reference materials will allow laboratories worldwide to establish metrological comparability for decades.