Fabien Leboeuf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fabien Leboeuf has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Morgan Sangeux
Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Centre for Clinical Motion Analysis, University Children's Hospital Basel, Switzerland
4 shared publications - Raphaël Gross
Nantes Université, CHU Nantes, Movement - Interactions - Performance, MIP, UR 4334, 25 bis bd Guy Mollet, F-44000 Nantes, France
4 shared publications J. Reay
School of Health & Society, The University of Salford, UK
3 shared publicationsM. Sangeux
University Children's Hospital, Basel, Switzerland
3 shared publicationsMickael Fonseca
Unige geneve
3 shared publicationsMorgan Sangeux
UKBB
3 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by Elsevier in Annals of Physical and Rehabilitation Medicine
- Vol. 69 (7) , 102151
Impaired gastrocnemius medialis muscle-tendon decoupling reduces gait efficiency in spastic paresis syndrome
- 5 August 2026
- Published by Elsevier in Annals of Physical and Rehabilitation Medicine
- Vol. 69 (7) , 102151
Open AccessImpaired gastrocnemius medialis muscle-tendon decoupling reduces gait efficiency in spastic paresis syndrome
- 19 May 2026
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 36 (5) , e70300
Impact of Correcting for Pelvic Tilt on the Assessment of Concentric Hip Extension Torque: Validity and Reliability of Isokinetic Dynamometry
A low hip extensor strength has been associated with various musculoskeletal injuries and an impaired motor performance. Hip strength is often assessed by using an isokinetic dynamometer. However, the validity and reliability of such testing have not been examined comprehensively. In this study, 14 participants performed maximal concentric contractions on a dynamometer in supine position at 60° s −1 , 120° s −1 , 180° s −1 , and 350° s −1 on two different days to assess inter‐day reliability. Hip angle and angular velocity were determined using 3‐D motion analysis (3‐D MOCAP) and were compared to the angle and angular velocity of the dynamometer. Additionally, we corrected dynamometer kinematics using linear regressions incorporating pelvic tilt angle and angular velocity. Our results showed that the dynamometer angle was lower than the hip angle based on 3‐D MOCAP ( p < 0.001). This was mostly explained by pelvic tilt (R 2 = 0.81). From 60° to 180° s −1 the torque was lower when the range of motion was defined based on 3‐D MOCAP ( d = 1.0–1.2, p < 0.001) compared to the dynamometer, which difference was reduced significantly after correcting the hip angle for the pelvic tilt by applying regression models ( d = 0.12–0.35, p > 0.05). From 45° to 20° hip angles the reliability of torque was good‐to‐excellent except at 350° s −1 . In future studies, considering pelvic tilt may improve the accuracy and reliability of examining hip extension torque.
- 19 May 2026
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 36 (5) , e70300
Impact of Correcting for Pelvic Tilt on the Assessment of Concentric Hip Extension Torque: Validity and Reliability of Isokinetic Dynamometry
A low hip extensor strength has been associated with various musculoskeletal injuries and an impaired motor performance. Hip strength is often assessed by using an isokinetic dynamometer. However, the validity and reliability of such testing have not been examined comprehensively. In this study, 14 participants performed maximal concentric contractions on a dynamometer in supine position at 60° s −1 , 120° s −1 , 180° s −1 , and 350° s −1 on two different days to assess inter‐day reliability. Hip angle and angular velocity were determined using 3‐D motion analysis (3‐D MOCAP) and were compared to the angle and angular velocity of the dynamometer. Additionally, we corrected dynamometer kinematics using linear regressions incorporating pelvic tilt angle and angular velocity. Our results showed that the dynamometer angle was lower than the hip angle based on 3‐D MOCAP ( p < 0.001). This was mostly explained by pelvic tilt (R 2 = 0.81). From 60° to 180° s −1 the torque was lower when the range of motion was defined based on 3‐D MOCAP ( d = 1.0–1.2, p < 0.001) compared to the dynamometer, which difference was reduced significantly after correcting the hip angle for the pelvic tilt by applying regression models ( d = 0.12–0.35, p > 0.05). From 45° to 20° hip angles the reliability of torque was good‐to‐excellent except at 350° s −1 . In future studies, considering pelvic tilt may improve the accuracy and reliability of examining hip extension torque.
- Open Access
Effect of the conventional gait model 2 variants on lower-limb kinematics in individuals with cerebral palsy
Background Three dimensional gait analysis (3DGA) is widely used to support clinical decision making in individuals with motor impairments. However, kinematic outputs depend strongly on the underlying biomechanical model. The open source Conventional Gait Model II (CGM2) integrates updates to joint centre estimation (CGM2.1), inverse kinematics (CGM2.2), and cluster based segment tracking (CGM2.3). While previous work demonstrated consistency among CGM2 variants in typically developing children, their effect in clinical populations remains unknown. This study quantified how CGM2 variants influence gait kinematics in individuals with cerebral palsy (CP). Methods Twenty one individuals with CP (GMFCS I , II) underwent 3DGA using a 12 camera motion capture system and a CGM2.3 marker set. Hip, knee, and ankle kinematics from 487 gait cycles were computed using pyCGM2. Differences between CGM2.1, CGM2.2, and CGM2.3 were evaluated using Mean Absolute Deviation (MAD) and the adjusted coefficient of determination (R2). Results Overall, small differences were observed between model variants. MAD values were typically below 5 deg for most joints and planes, with high correlation between curves (R2>0.7). Hip rotation showed the largest discrepancies, with maximum MAD up to 7.7 deg when comparing CGM2.2 and CGM2.3. Differences between CGM2.1 and CGM2.3 were greater in the transverse and frontal planes but remained within acceptable limits (<5 deg), except for hip rotation. Conclusion The CGM2 variant selection has limited impact on gait kinematics in individuals with CP, and most differences fall within known repeatability error. However, transverse plane kinematics, particularly hip rotation, should be interpreted with caution when comparing data across CGM2 variants
Open AccessEffect of the conventional gait model 2 variants on lower-limb kinematics in individuals with cerebral palsy
Background Three dimensional gait analysis (3DGA) is widely used to support clinical decision making in individuals with motor impairments. However, kinematic outputs depend strongly on the underlying biomechanical model. The open source Conventional Gait Model II (CGM2) integrates updates to joint centre estimation (CGM2.1), inverse kinematics (CGM2.2), and cluster based segment tracking (CGM2.3). While previous work demonstrated consistency among CGM2 variants in typically developing children, their effect in clinical populations remains unknown. This study quantified how CGM2 variants influence gait kinematics in individuals with cerebral palsy (CP). Methods Twenty one individuals with CP (GMFCS I , II) underwent 3DGA using a 12 camera motion capture system and a CGM2.3 marker set. Hip, knee, and ankle kinematics from 487 gait cycles were computed using pyCGM2. Differences between CGM2.1, CGM2.2, and CGM2.3 were evaluated using Mean Absolute Deviation (MAD) and the adjusted coefficient of determination (R2). Results Overall, small differences were observed between model variants. MAD values were typically below 5 deg for most joints and planes, with high correlation between curves (R2>0.7). Hip rotation showed the largest discrepancies, with maximum MAD up to 7.7 deg when comparing CGM2.2 and CGM2.3. Differences between CGM2.1 and CGM2.3 were greater in the transverse and frontal planes but remained within acceptable limits (<5 deg), except for hip rotation. Conclusion The CGM2 variant selection has limited impact on gait kinematics in individuals with CP, and most differences fall within known repeatability error. However, transverse plane kinematics, particularly hip rotation, should be interpreted with caution when comparing data across CGM2 variants
- Open Access
Within- and Between-Assessor Reliability of Biarticular Muscle-Tendon Unit Lengths: Application of a Conventional Gait Model 2-based musculoskeletal model
Cerebral palsy (CP) is characterized by neuromusculoskeletal impairments, including reduced muscle fiber lengths, which alter muscle-tendon unit (MTU) lengths and contribute to gait deviations. Estimation of MTU length reliability using musculoskeletal modeling is essential for guiding interventions such as muscle lengthening. This study aims to assess within-assessor (WA) and between-assessor (BA) reliability of MTU length estimation during gait in CP and non-impaired (NI) individuals. 38 individuals (19CP,19TD) participated in 3 3DGA sessions (2 by the same assessor). Normalized MTU length, MTU lengthening, and maximum lengthening range of the rectus femoris, semitendinosus, and gastrocnemius medialis were reported. Reliability was quantified through the standard error of measurement (SEM) and minimal detectable change (MDC). The mean SEM (MDC) during the gait ranged from 1.0-2.1% (2.5-5.7%) for normalized MTU length, from 3.6-8.7 mm (10.1-24.1 mm) for MTU lengthening, and from 2.9-8.0 mm (8.0-22.1 mm) for MTU lengthening range in individuals with CP. In NI individuals, the mean SEM (MDC) during the cycle ranged from 0.6-1.3% (1.8-3.7%) for normalized MTU length, from 2.6-5.0 mm (7.3-13.9 mm) for MTU lengthening, and from 2.7-5.0 mm (7.5-12.4 mm) for MTU lengthening range. Results suggest reliable estimations by the
Open AccessWithin- and Between-Assessor Reliability of Biarticular Muscle-Tendon Unit Lengths: Application of a Conventional Gait Model 2-based musculoskeletal model
Cerebral palsy (CP) is characterized by neuromusculoskeletal impairments, including reduced muscle fiber lengths, which alter muscle-tendon unit (MTU) lengths and contribute to gait deviations. Estimation of MTU length reliability using musculoskeletal modeling is essential for guiding interventions such as muscle lengthening. This study aims to assess within-assessor (WA) and between-assessor (BA) reliability of MTU length estimation during gait in CP and non-impaired (NI) individuals. 38 individuals (19CP,19TD) participated in 3 3DGA sessions (2 by the same assessor). Normalized MTU length, MTU lengthening, and maximum lengthening range of the rectus femoris, semitendinosus, and gastrocnemius medialis were reported. Reliability was quantified through the standard error of measurement (SEM) and minimal detectable change (MDC). The mean SEM (MDC) during the gait ranged from 1.0-2.1% (2.5-5.7%) for normalized MTU length, from 3.6-8.7 mm (10.1-24.1 mm) for MTU lengthening, and from 2.9-8.0 mm (8.0-22.1 mm) for MTU lengthening range in individuals with CP. In NI individuals, the mean SEM (MDC) during the cycle ranged from 0.6-1.3% (1.8-3.7%) for normalized MTU length, from 2.6-5.0 mm (7.3-13.9 mm) for MTU lengthening, and from 2.7-5.0 mm (7.5-12.4 mm) for MTU lengthening range. Results suggest reliable estimations by the
- Open Access
Methodological updates in the Conventional Gait Model 2 preserve kinematic reliability in asymptomatic and cerebral palsy individuals
Three-dimensional gait analysis is widely used to support clinical decision-making in neuromuscular disorders, with the Conventional Gait Model (CGM) being the most commonly applied biomechanical model in clinical practice. Recent developments of the CGM, grouped under the open-source CGM2 framework, introduced methodological updates intended to improve robustness while preserving backward compatibility. However, the reliability of these successive CGM2 iterations has not been comprehensively evaluated, particularly in pathological gait populations. This study investigated within- and between-assessor reliability of lower-limb kinematics across three CGM2 versions (2.1, 2.2, and 2.3) in asymptomatic participants and individuals with cerebral palsy. Reliability was quantified using standard error of measurement and minimal detectable change across the gait cycle. Overall measurement error remained low and consistent across models and participant groups, with standard errors close to 2 deg and minimal detectable changes around 6 deg. Introducing kinematic fitting had minimal influence on reliability, while adding tracking markers on the thigh and shank produced a modest reduction in hip transverse rotation error. These findings indicate that methodological refinements implemented in CGM2 preserve the reliability of the original CGM while providing incremental improvements for clinically relevant parameters, supporting its use in both asymptomatic and pathological gait analysis and longitudinal clinical assessments
Open AccessMethodological updates in the Conventional Gait Model 2 preserve kinematic reliability in asymptomatic and cerebral palsy individuals
Three-dimensional gait analysis is widely used to support clinical decision-making in neuromuscular disorders, with the Conventional Gait Model (CGM) being the most commonly applied biomechanical model in clinical practice. Recent developments of the CGM, grouped under the open-source CGM2 framework, introduced methodological updates intended to improve robustness while preserving backward compatibility. However, the reliability of these successive CGM2 iterations has not been comprehensively evaluated, particularly in pathological gait populations. This study investigated within- and between-assessor reliability of lower-limb kinematics across three CGM2 versions (2.1, 2.2, and 2.3) in asymptomatic participants and individuals with cerebral palsy. Reliability was quantified using standard error of measurement and minimal detectable change across the gait cycle. Overall measurement error remained low and consistent across models and participant groups, with standard errors close to 2 deg and minimal detectable changes around 6 deg. Introducing kinematic fitting had minimal influence on reliability, while adding tracking markers on the thigh and shank produced a modest reduction in hip transverse rotation error. These findings indicate that methodological refinements implemented in CGM2 preserve the reliability of the original CGM while providing incremental improvements for clinically relevant parameters, supporting its use in both asymptomatic and pathological gait analysis and longitudinal clinical assessments
- Open Access
The FeetMe® Insoles System: Repeatability, Standard Error of Measure, and Responsiveness
Background: Three-dimensional motion analysis using optoelectronic cameras and force platforms is typically used to quantify gait disorders. However, these systems have various limitations, particularly when assessing patients in an ecological environment. To address these limitations, several wearable devices have been developed. However, few studies have reported metrological information regarding their repeatability and sensitivity to change. Methods: A healthy adult performed 6 min walking tests with FeetMe® system insoles under different walking conditions overground and on a treadmill. The standard error of measurement (SEM), the minimum detectable differences (MDDs), and the effect size (ES) were calculated for spatio-temporal parameters, and the ground reaction force was calculated from the 16,000 steps recorded. Results: SEM values were below 3.9% for the ground reaction force and below 6.8% for spatio-temporal parameters. ES values were predominantly high, with 72.9% of cases between overground and treadmill conditions with induced asymmetry, and 64.5% of cases between treadmill conditions with and without induced asymmetry exhibiting an ES greater than 1.2. The minimum detectable differences ranged from 4.5% to 10.7% for ground reaction forces and 2.1% to 18.9% for spatio-temporal parameters. Conclusion: Our study demonstrated that the FeetMe® system is a reliable solution. The sensitivity to change showed that these instrumented insoles can effectively reflect patient asymmetry and progress.
Open AccessThe FeetMe® Insoles System: Repeatability, Standard Error of Measure, and Responsiveness
Background: Three-dimensional motion analysis using optoelectronic cameras and force platforms is typically used to quantify gait disorders. However, these systems have various limitations, particularly when assessing patients in an ecological environment. To address these limitations, several wearable devices have been developed. However, few studies have reported metrological information regarding their repeatability and sensitivity to change. Methods: A healthy adult performed 6 min walking tests with FeetMe® system insoles under different walking conditions overground and on a treadmill. The standard error of measurement (SEM), the minimum detectable differences (MDDs), and the effect size (ES) were calculated for spatio-temporal parameters, and the ground reaction force was calculated from the 16,000 steps recorded. Results: SEM values were below 3.9% for the ground reaction force and below 6.8% for spatio-temporal parameters. ES values were predominantly high, with 72.9% of cases between overground and treadmill conditions with induced asymmetry, and 64.5% of cases between treadmill conditions with and without induced asymmetry exhibiting an ES greater than 1.2. The minimum detectable differences ranged from 4.5% to 10.7% for ground reaction forces and 2.1% to 18.9% for spatio-temporal parameters. Conclusion: Our study demonstrated that the FeetMe® system is a reliable solution. The sensitivity to change showed that these instrumented insoles can effectively reflect patient asymmetry and progress.
- 24 August 2023
- Published by Elsevier in Journal of Biomechanics
- Vol. 159, 111774
On the accuracy of the Conventional gait Model: Distinction between marker misplacement and soft tissue artefact errors
- 24 August 2023
- Published by Elsevier in Journal of Biomechanics
- Vol. 159, 111774
On the accuracy of the Conventional gait Model: Distinction between marker misplacement and soft tissue artefact errors
- 16 December 2022
- Published by Elsevier in Gait & Posture
- Vol. 100, 243-246
Wand-mounted lateral markers are less prone to misplacement and soft-tissue artefacts than skin-mounted markers when using the conventional gait model
- 16 December 2022
- Published by Elsevier in Gait & Posture
- Vol. 100, 243-246
Wand-mounted lateral markers are less prone to misplacement and soft-tissue artefacts than skin-mounted markers when using the conventional gait model
- Open Access
- 20 June 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (12) , 7527
Gait Alteration Due to Haemophilic Arthropathies in Patients with Moderate Haemophilia
Some patients with moderate haemophilia (PWMH) report joint damage potentially responsible for gait disorders. Three-dimensional gait analysis (3DGA) is a relevant tool for the identification of complex musculoskeletal impairment. We performed an evaluation with 3DGA of 24 PWMH aged 44.3 ± 16.1 according to their joint status [Haemophilia Joint Health Score (HJHS) < 10 or HJHS ≥ 10] and assessed the correlation with the radiological and clinical parameters. Sixteen had HJHS < 10 (group 1) and eight had HJHS ≥ 10 (group 2). They were compared to 30 healthy subjects of a normative dataset. Both knee and ankle gait variable scores were increased in group 2 compared to the controls (p = 0.02 and p = 0.04, respectively). The PWMH of group 2 had a significant increase in their stance phase, double support duration, and stride width compared to the controls and group 1 (p < 0.01). Very low correlations were found for the ankle gait variable score with the ankle Pettersson sub-score (r2 = 0.250; p = 0.004) and ankle HJHS sub-score (r2 = 0.150; p = 0.04). For the knee, very low correlation was also found between the knee gait variable score and its HJHS sub-score (r2 = 0.290; p < 0.0001). Patients with moderate haemophilia presented a gait alteration in the case of poor lower limb joint status.
- 20 June 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (12) , 7527
Open AccessGait Alteration Due to Haemophilic Arthropathies in Patients with Moderate Haemophilia
Some patients with moderate haemophilia (PWMH) report joint damage potentially responsible for gait disorders. Three-dimensional gait analysis (3DGA) is a relevant tool for the identification of complex musculoskeletal impairment. We performed an evaluation with 3DGA of 24 PWMH aged 44.3 ± 16.1 according to their joint status [Haemophilia Joint Health Score (HJHS) < 10 or HJHS ≥ 10] and assessed the correlation with the radiological and clinical parameters. Sixteen had HJHS < 10 (group 1) and eight had HJHS ≥ 10 (group 2). They were compared to 30 healthy subjects of a normative dataset. Both knee and ankle gait variable scores were increased in group 2 compared to the controls (p = 0.02 and p = 0.04, respectively). The PWMH of group 2 had a significant increase in their stance phase, double support duration, and stride width compared to the controls and group 1 (p < 0.01). Very low correlations were found for the ankle gait variable score with the ankle Pettersson sub-score (r2 = 0.250; p = 0.004) and ankle HJHS sub-score (r2 = 0.150; p = 0.04). For the knee, very low correlation was also found between the knee gait variable score and its HJHS sub-score (r2 = 0.290; p < 0.0001). Patients with moderate haemophilia presented a gait alteration in the case of poor lower limb joint status.