Mahesh R. Gadekar
Mahesh R. Gadekar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- M. Mansoor Ahammed
Department of Civil Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
5 shared publications - Akshaykumar M. Bhoi
SGGS Institute of Engineering and Technology
1 shared publication E. V. Vinitha
Civil Engineering Department, SV National Institute of Technology, Surat 395 007, India
1 shared publicationHimanshu Malunjkar
Green Design and Engineering Services, Construction Management
1 shared publicationJayesh Umale
SGGS Institute of Engineering and Technology
1 shared publication- Pramod Kolase
Pravara Rural Engineering College
1 shared publication
Latest Publications
- 24 October 2026
- Published by Springer Nature
- p. 322-331
Bridging the Gap: Understanding Delays to Enhance Sustainability in Road and Bridge Projects
- 24 October 2026
- Published by Springer Nature
- p. 322-331
Bridging the Gap: Understanding Delays to Enhance Sustainability in Road and Bridge Projects
- Open Access
- 11 June 2020
- Published by Springer Nature in Applied Water Science
- Vol. 10 (7) , 1-8
Use of water treatment residuals for colour removal from real textile dye wastewater
The use of readily available water treatment residuals (WTR) as a low-cost material for removal of colour from real textile wastewater was investigated. WTR was used in three forms, namely in raw wet form as a coagulant, in the dried form as an adsorbent and as a filtration media in column tests. The results showed a maximum colour removal of 55 and 36% by coagulation and adsorption, respectively, and the corresponding COD removals were 35 and 37%. Coagulation and batch sorption tests showed the effect of initial pH on the colour removal, and maximum colour removal was obtained at an initial pH of 3.0. Long-duration continuous-flow column test using WTR as a filtration/sorption media showed that a maximum colour removal of 60% can be achieved. In column studies, complete exhaustion of the media occurred at 180 and 120 bed volumes, respectively, for initial pHs of 3.0 and 6.2. The study thus shows the potential of WTR for primary treatment of real textile dye wastewater.
- 11 June 2020
- Published by Springer Nature in Applied Water Science
- Vol. 10 (7) , 1-8
Open AccessUse of water treatment residuals for colour removal from real textile dye wastewater
The use of readily available water treatment residuals (WTR) as a low-cost material for removal of colour from real textile wastewater was investigated. WTR was used in three forms, namely in raw wet form as a coagulant, in the dried form as an adsorbent and as a filtration media in column tests. The results showed a maximum colour removal of 55 and 36% by coagulation and adsorption, respectively, and the corresponding COD removals were 35 and 37%. Coagulation and batch sorption tests showed the effect of initial pH on the colour removal, and maximum colour removal was obtained at an initial pH of 3.0. Long-duration continuous-flow column test using WTR as a filtration/sorption media showed that a maximum colour removal of 60% can be achieved. In column studies, complete exhaustion of the media occurred at 180 and 120 bed volumes, respectively, for initial pHs of 3.0 and 6.2. The study thus shows the potential of WTR for primary treatment of real textile dye wastewater.
- 1 February 2019
- Published by Elsevier in Journal of Environmental Management
- Vol. 231, 241-248
Modelling dye removal by adsorption onto water treatment residuals using combined response surface methodology-artificial neural network approach
- 1 February 2019
- Published by Elsevier in Journal of Environmental Management
- Vol. 231, 241-248
Modelling dye removal by adsorption onto water treatment residuals using combined response surface methodology-artificial neural network approach
- 11 June 2018
- Published by IWA Publishing in Water Science & Technology
- Vol. 2017 (3) , 869-877
Chemical coagulation of greywater: modelling using artificial neural networks
In the present study, chemical coagulation with alum and polyaluminium chloride (PACl) was utilized for greywater treatment. More than 140 jar tests on greywater with varying characteristics were conducted in order to determine the optimum coagulant dosage and treated greywater characteristics. The average removal efficiencies of turbidity, chemical oxygen demand (COD) and total suspended solids were obtained as 91, 73 and 83% using alum and 93, 74 and 89% using PACl, respectively. For similar initial turbidity levels, optimum PACl dosages required were significantly less compared to optimum alum dosages. Further, PACl produced treated greywater with lower levels of turbidity compared to alum. Results of the coagulation tests were used to design artificial neural network (ANN) models for the prediction of the optimum coagulant dosage and treated greywater quality parameters. ANN models with initial turbidity, pH, conductivity and alkalinity as the input parameters could predict the optimum coagulant dose and treated greywater quality. The performance of the models was found to be good, with correlation coefficient values greater than 0.80. Empirical formulas for the prediction of alum and PACl dosages were also derived using the algorithm weights and bias values from the networks eliminating the need for running the ANN software.
- 11 June 2018
- Published by IWA Publishing in Water Science & Technology
- Vol. 2017 (3) , 869-877
Chemical coagulation of greywater: modelling using artificial neural networks
In the present study, chemical coagulation with alum and polyaluminium chloride (PACl) was utilized for greywater treatment. More than 140 jar tests on greywater with varying characteristics were conducted in order to determine the optimum coagulant dosage and treated greywater characteristics. The average removal efficiencies of turbidity, chemical oxygen demand (COD) and total suspended solids were obtained as 91, 73 and 83% using alum and 93, 74 and 89% using PACl, respectively. For similar initial turbidity levels, optimum PACl dosages required were significantly less compared to optimum alum dosages. Further, PACl produced treated greywater with lower levels of turbidity compared to alum. Results of the coagulation tests were used to design artificial neural network (ANN) models for the prediction of the optimum coagulant dosage and treated greywater quality parameters. ANN models with initial turbidity, pH, conductivity and alkalinity as the input parameters could predict the optimum coagulant dose and treated greywater quality. The performance of the models was found to be good, with correlation coefficient values greater than 0.80. Empirical formulas for the prediction of alum and PACl dosages were also derived using the algorithm weights and bias values from the networks eliminating the need for running the ANN software.
- Open Access
- 1 January 2018
- Published by Elsevier in Desalination and Water Treatment
- Vol. 102, 264-272
Removal of disperse dye from aqueous solution in fixed-bed column by water treatment residuals
- 1 January 2018
- Published by Elsevier in Desalination and Water Treatment
- Vol. 102, 264-272
Open AccessRemoval of disperse dye from aqueous solution in fixed-bed column by water treatment residuals
- Open Access
- 29 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (55) , 26392-26400
Coagulation/flocculation process for dye removal using water treatment residuals: modelling through artificial neural networks
The potential of aluminum-based water treatment residuals (WTR) discharged from water treatment plants was evaluated as a coagulant for color removal from a disperse dye solution. The effects of WTR dose, initial dye concentration, and initial pH on color removal were studied. The results showed higher color removal at lower pH values. Maximum color removals of 88, 87, and 76% were obtained for initial dye concentrations of 25, 50, and 75 mg/L, respectively, at pH 3.0 with a WTR dose of 3,000 mg/L. Different artificial neural networks (ANN) were developed for predicting the color removal. The performance of the models was found to be very good, with correlation coefficient (R2) values greater than 0.90. The results showed that simulation employing ANN incorporates non-linear behavior of the system, and the model-predicted and observed values of color removals were in close agreement with each other. The study thus indicates that reusing water treatment sludge as a coagulant for color removal would be an attractive option.
- 29 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (55) , 26392-26400
Open AccessCoagulation/flocculation process for dye removal using water treatment residuals: modelling through artificial neural networks
The potential of aluminum-based water treatment residuals (WTR) discharged from water treatment plants was evaluated as a coagulant for color removal from a disperse dye solution. The effects of WTR dose, initial dye concentration, and initial pH on color removal were studied. The results showed higher color removal at lower pH values. Maximum color removals of 88, 87, and 76% were obtained for initial dye concentrations of 25, 50, and 75 mg/L, respectively, at pH 3.0 with a WTR dose of 3,000 mg/L. Different artificial neural networks (ANN) were developed for predicting the color removal. The performance of the models was found to be very good, with correlation coefficient (R2) values greater than 0.90. The results showed that simulation employing ANN incorporates non-linear behavior of the system, and the model-predicted and observed values of color removals were in close agreement with each other. The study thus indicates that reusing water treatment sludge as a coagulant for color removal would be an attractive option.