Tomasz Kuder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomasz Kuder has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Paul Philp
School of Geology and Geophysics, University of Oklahoma, 100 E. Boyd Street, SEC 710, Norman, OK 73019, United States
7 shared publicationsJon Allen
School of Geology and Geophysics, University of Oklahoma, 100 E. Boyd Street, SEC 810, Norman, Oklahoma 73019
2 shared publicationsMonika Klisch
2 shared publicationsR. P. Philp
2 shared publicationsRavi Kolhatkar
University of Oklahoma, Norman, Oklahoma 73019, United States Environmental Protection Agency, Ada, Oklahoma 74820, and Atlantic Richfield Company, La Palma, California 90623
2 shared publicationsThomas McHugh
2 shared publications
Latest Publications
- 24 February 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (3) , 712-719
Hydrogen Isotope Exchange between Trichloroethene and Water under Mild Environmental Conditions─Implications for the Use of Hydrogen CSIA in Contaminated Site Assessment
- 24 February 2023
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 3 (3) , 712-719
Hydrogen Isotope Exchange between Trichloroethene and Water under Mild Environmental Conditions─Implications for the Use of Hydrogen CSIA in Contaminated Site Assessment
- 4 December 2018
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 33 (7) , 667-677
Derivatization‐free method for compound‐specific isotope analysis of nonexchangeable hydrogen of 4‐bromophenol
Rationale: Compound‐specific isotope analysis (CSIA) is a valuable tool in environmental chemistry and in other fields of science. Currently, hydrogen CSIA of polar compounds containing exchangeable hydrogen is uncommon. To extend the scope of CSIA applications, we present an alternative method of analysis, bypassing the typical step of derivatization. The method is demonstrated for two environmental contaminants, 4‐bromophenol (4 BP ) and 2,4,6‐tribromophenol (TBP). Methods: Net isotope ratios obtained by CSIA combine the isotope composition of nonexchangeable, carbon‐bound hydrogen and the exchangeable hydroxyl hydrogen. To constrain the isotope composition of the latter, an ethyl acetate solution of 4 BP or TBP injected into the IRMS instrument was amended with excess water of known isotope composition. The results were calibrated using bracketing control samples analyzed in sequence with the unknown samples and the known isotope ratios of water present in ethyl acetate solution. Results: The analytical precision was comparable to the precision for halogenated compounds without exchangeable hydrogen, analyzed using similar instrumentation. The isotope ratios of the bromophenols correlated with the isotope composition of the water in the sample matrix, suggesting that the hydroxyl group of the target compound remained close to the equilibrium with the sample water during the passage through the instrument. Based on this relationship, the signatures of the nonexchangeable hydrogen were obtained using the isotope composition of sample water as the proxy for the isotope composition of the target compound hydroxyl group. Conclusions: The developed method could be adopted to analysis of other low molecular weight compounds amenable to gas chromatography without the absolute need for derivatization. Currently, the method can be used for samples from laboratory experiments, with high concentrations of the target compound to provide mechanistic insight into the degradation mechanisms. Further work would be required to optimize the method to low concentration environmental samples.
- 4 December 2018
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 33 (7) , 667-677
Derivatization‐free method for compound‐specific isotope analysis of nonexchangeable hydrogen of 4‐bromophenol
Rationale: Compound‐specific isotope analysis (CSIA) is a valuable tool in environmental chemistry and in other fields of science. Currently, hydrogen CSIA of polar compounds containing exchangeable hydrogen is uncommon. To extend the scope of CSIA applications, we present an alternative method of analysis, bypassing the typical step of derivatization. The method is demonstrated for two environmental contaminants, 4‐bromophenol (4 BP ) and 2,4,6‐tribromophenol (TBP). Methods: Net isotope ratios obtained by CSIA combine the isotope composition of nonexchangeable, carbon‐bound hydrogen and the exchangeable hydroxyl hydrogen. To constrain the isotope composition of the latter, an ethyl acetate solution of 4 BP or TBP injected into the IRMS instrument was amended with excess water of known isotope composition. The results were calibrated using bracketing control samples analyzed in sequence with the unknown samples and the known isotope ratios of water present in ethyl acetate solution. Results: The analytical precision was comparable to the precision for halogenated compounds without exchangeable hydrogen, analyzed using similar instrumentation. The isotope ratios of the bromophenols correlated with the isotope composition of the water in the sample matrix, suggesting that the hydroxyl group of the target compound remained close to the equilibrium with the sample water during the passage through the instrument. Based on this relationship, the signatures of the nonexchangeable hydrogen were obtained using the isotope composition of sample water as the proxy for the isotope composition of the target compound hydroxyl group. Conclusions: The developed method could be adopted to analysis of other low molecular weight compounds amenable to gas chromatography without the absolute need for derivatization. Currently, the method can be used for samples from laboratory experiments, with high concentrations of the target compound to provide mechanistic insight into the degradation mechanisms. Further work would be required to optimize the method to low concentration environmental samples.
- 1 June 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 625, 696-705
Assessment of anaerobic biodegradation of bis(2-chloroethyl) ether in groundwater using carbon and chlorine compound-specific isotope analysis
- 1 June 2018
- Published by Elsevier in Science of The Total Environment
- Vol. 625, 696-705
Assessment of anaerobic biodegradation of bis(2-chloroethyl) ether in groundwater using carbon and chlorine compound-specific isotope analysis
- Open Access
- 1 September 2017
- Published by Elsevier in Journal of Contaminant Hydrology
- Vol. 204, 79-89
Modeling 3D-CSIA data: Carbon, chlorine, and hydrogen isotope fractionation during reductive dechlorination of TCE to ethene
- 1 September 2017
- Published by Elsevier in Journal of Contaminant Hydrology
- Vol. 204, 79-89
Open AccessModeling 3D-CSIA data: Carbon, chlorine, and hydrogen isotope fractionation during reductive dechlorination of TCE to ethene
- 5 February 2013
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 47 (3) , 1461-1467
Demonstration of Compound-Specific Isotope Analysis of Hydrogen Isotope Ratios in Chlorinated Ethenes
High-temperature pyrolysis conversion of organic analytes to H(2) in hydrogen isotope ratio compound-specific isotope analysis (CSIA) is unsuitable for chlorinated compounds such as trichloroethene (TCE) and cis-1,2-dichloroethene (DCE), due to competition from HCl formation. For this reason, the information potential of hydrogen isotope ratios of chlorinated ethenes remains untapped. We present a demonstration of an alternative approach where chlorinated analytes reacted with chromium metal to form H(2) and minor amounts of HCl. The values of δ(2)H were obtained at satisfactory precision (± 10 to 15 per thousand), however the raw data required daily calibration by TCE and/or DCE standards to correct for analytical bias that varies over time. The chromium reactor has been incorporated into a purge and trap-CSIA method that is suitable for CSIA of aqueous environmental samples. A sample data set was obtained for six specimens of commercial product TCE. The resulting values of δ(2)H were between -184 and +682 ‰, which significantly widened the range of manufactured TCE δ(2)H signatures identified by past work. The implications of this finding to the assessment of TCE contamination are discussed.
- 5 February 2013
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 47 (3) , 1461-1467
Demonstration of Compound-Specific Isotope Analysis of Hydrogen Isotope Ratios in Chlorinated Ethenes
High-temperature pyrolysis conversion of organic analytes to H(2) in hydrogen isotope ratio compound-specific isotope analysis (CSIA) is unsuitable for chlorinated compounds such as trichloroethene (TCE) and cis-1,2-dichloroethene (DCE), due to competition from HCl formation. For this reason, the information potential of hydrogen isotope ratios of chlorinated ethenes remains untapped. We present a demonstration of an alternative approach where chlorinated analytes reacted with chromium metal to form H(2) and minor amounts of HCl. The values of δ(2)H were obtained at satisfactory precision (± 10 to 15 per thousand), however the raw data required daily calibration by TCE and/or DCE standards to correct for analytical bias that varies over time. The chromium reactor has been incorporated into a purge and trap-CSIA method that is suitable for CSIA of aqueous environmental samples. A sample data set was obtained for six specimens of commercial product TCE. The resulting values of δ(2)H were between -184 and +682 ‰, which significantly widened the range of manufactured TCE δ(2)H signatures identified by past work. The implications of this finding to the assessment of TCE contamination are discussed.
- 6 July 2012
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 46 (14) , 7495-7502
Carbon Isotope Fractionation in Reactions of 1,2-Dibromoethane with FeS and Hydrogen Sulfide
EDB (1,2-dibromoethane) is frequently detected at sites impacted by leaded gasoline. In reducing environments, EDB is highly susceptible to abiotic degradation. A study was conducted to evaluate the potential of compound-specific isotope analysis (CSIA) in assessing abiotic degradation of EDB in sulfate-reducing environments. Water containing EDB was incubated in sealed vials with various combinations of Na(2)S (<0.7 mM) and mackinawite (FeS) (180 mM). Degradation rates in vials containing FeS exceeded those in Na(2)S-only controls. In the presence of FeS, first-order constants ranged from 0.034 ± 0.002 d(-1) at pH 6 to 0.081 ± 0.005 d(-1) at pH 8.5. In the presence of FeS, products from reductive debromination (ethylene) and from S(N)2 substitution with S(II) nucleophiles were detected (1,2-dithioethane, DTA). Relatively high yields of DTA suggested that the S(N)2 reactions were not mediated by HS(-) only but likely also included reactions mediated by FeS surface. Significant carbon isotope effects were observed for nucleophilic substitution by HS(-) (ε = -31.6 ± 3.7‰) and for a combination of reductive and substitution pathways in the presence of FeS (-30.9 ± 0.7‰), indicating good site assessment potential of CSIA. The isotope effects (KIEs) observed in the presence of FeS corroborated the predominance of S(N)2 substitution by nucleophiles combined with two-electron transfer reductive debromination.
- 6 July 2012
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 46 (14) , 7495-7502
Carbon Isotope Fractionation in Reactions of 1,2-Dibromoethane with FeS and Hydrogen Sulfide
EDB (1,2-dibromoethane) is frequently detected at sites impacted by leaded gasoline. In reducing environments, EDB is highly susceptible to abiotic degradation. A study was conducted to evaluate the potential of compound-specific isotope analysis (CSIA) in assessing abiotic degradation of EDB in sulfate-reducing environments. Water containing EDB was incubated in sealed vials with various combinations of Na(2)S (<0.7 mM) and mackinawite (FeS) (180 mM). Degradation rates in vials containing FeS exceeded those in Na(2)S-only controls. In the presence of FeS, first-order constants ranged from 0.034 ± 0.002 d(-1) at pH 6 to 0.081 ± 0.005 d(-1) at pH 8.5. In the presence of FeS, products from reductive debromination (ethylene) and from S(N)2 substitution with S(II) nucleophiles were detected (1,2-dithioethane, DTA). Relatively high yields of DTA suggested that the S(N)2 reactions were not mediated by HS(-) only but likely also included reactions mediated by FeS surface. Significant carbon isotope effects were observed for nucleophilic substitution by HS(-) (ε = -31.6 ± 3.7‰) and for a combination of reductive and substitution pathways in the presence of FeS (-30.9 ± 0.7‰), indicating good site assessment potential of CSIA. The isotope effects (KIEs) observed in the presence of FeS corroborated the predominance of S(N)2 substitution by nucleophiles combined with two-electron transfer reductive debromination.
- 1 January 2012
- Published by Defense Technical Information Center (DTIC)
Use of Compound Specific Stable Isotope Analysis to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs
The objective of the present study is an empirical validation of selected adsorbents for preconcentration of TCE, PCE and benzene in air samples containing low concentrations of these VOCs. For validation of adsorbent tube performance, we sought to: 1) using reference data, select adsorbent-analyte pairings that would be likely to offer good quantitative recovery of the target VOCs; and 2) for those adsorbent-analyte pairings, evaluate sampling conditions that are representative of sampling indoor air and soil gas with respect to sample volume, humidity, mass of target VOC, mass of non-target VOCs, and holding time between sample collection and analysis; 3) investigate the recovery of target analytes mass and any associated isotope effects. The study results demonstrated fracrtionation-free performance for Carboxen 1016. These results allow precise isotope ratio analysis into vapor intrusion site assessment protocols and other applications where VOCs of interest are present at low ug/m3 concentrations.
- 1 January 2012
- Published by Defense Technical Information Center (DTIC)
Use of Compound Specific Stable Isotope Analysis to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs
The objective of the present study is an empirical validation of selected adsorbents for preconcentration of TCE, PCE and benzene in air samples containing low concentrations of these VOCs. For validation of adsorbent tube performance, we sought to: 1) using reference data, select adsorbent-analyte pairings that would be likely to offer good quantitative recovery of the target VOCs; and 2) for those adsorbent-analyte pairings, evaluate sampling conditions that are representative of sampling indoor air and soil gas with respect to sample volume, humidity, mass of target VOC, mass of non-target VOCs, and holding time between sample collection and analysis; 3) investigate the recovery of target analytes mass and any associated isotope effects. The study results demonstrated fracrtionation-free performance for Carboxen 1016. These results allow precise isotope ratio analysis into vapor intrusion site assessment protocols and other applications where VOCs of interest are present at low ug/m3 concentrations.
- 1 January 2012
- Published by Defense Technical Information Center (DTIC)
Use of Compound-Specific Stable Isotope Analysis to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs
The objective of the present study is an empirical validation of selected adsorbents for preconcentration of TCE, PCE and benzene in air samples containing low concentrations of these VOCs. For validation of adsorbent tube performance, we sought to: 1) using reference data, select adsorbent-analyte pairings that would be likely to offer good quantitative recovery of the target VOCs; and 2) for those adsorbent-analyte pairings, evaluate sampling conditions that are representative of sampling indoor air and soil gas with respect to sample volume, humidity, mass of target VOC, mass of non-target VOCs, and holding time between sample collection and analysis; 3) investigate the recovery of target analytes mass and any associated isotope effects. The study results demonstrated fracrtionation-free performance for Carboxen 1016. These results allow precise isotope ratio analysis into vapor intrusion site assessment protocols and other applications where VOCs of interest are present at low ug/m3 concentrations.
- 1 January 2012
- Published by Defense Technical Information Center (DTIC)
Use of Compound-Specific Stable Isotope Analysis to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs
The objective of the present study is an empirical validation of selected adsorbents for preconcentration of TCE, PCE and benzene in air samples containing low concentrations of these VOCs. For validation of adsorbent tube performance, we sought to: 1) using reference data, select adsorbent-analyte pairings that would be likely to offer good quantitative recovery of the target VOCs; and 2) for those adsorbent-analyte pairings, evaluate sampling conditions that are representative of sampling indoor air and soil gas with respect to sample volume, humidity, mass of target VOC, mass of non-target VOCs, and holding time between sample collection and analysis; 3) investigate the recovery of target analytes mass and any associated isotope effects. The study results demonstrated fracrtionation-free performance for Carboxen 1016. These results allow precise isotope ratio analysis into vapor intrusion site assessment protocols and other applications where VOCs of interest are present at low ug/m3 concentrations.
- 12 February 2009
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 43 (6) , 1763-1768
Effects of Volatilization on Carbon and Hydrogen Isotope Ratios of MTBE
Contaminant attenuation studies utilizing CSIA (compound-specific isotope analysis) routinely assume that isotope effects (IEs) result only from degradation. Experimental results on MTBE behavior in diffusive volatilization and dynamic vapor extraction show measurable changes in the isotope ratios of the MTBE remaining in the aqueous or nonaqueous phase liquid (NAPL) matrix. A conceptual model for interpretation of those IEs is proposed, based on the physics of liquid−air partitioning. Normal or inverse IEs were observed for different volatilization scenarios. The range of carbon enrichment factors (ε) was from +0.7‰ (gasoline vapor extraction) to −1‰ (diffusive volatilization of MTBE from gasoline), the range of hydrogen ε was from +7‰ (gasoline vapor extraction) to −12‰ (air sparging of aqueous MTBE). The observed IEs are lower than those associated with MTBE degradation. However, under a realistic scenario for MTBE vapor removal, their magnitude is within the detection limits of CSIA. The potential for interference of those IEs is primarily in confusing the interpretation of samples with a small extent of fractionation and where only carbon CSIA data are available. The IEs resulting from volatilization and biodegradation, respectively, can be separated by combined carbon and hydrogen 2D-CSIA.
- 12 February 2009
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 43 (6) , 1763-1768
Effects of Volatilization on Carbon and Hydrogen Isotope Ratios of MTBE
Contaminant attenuation studies utilizing CSIA (compound-specific isotope analysis) routinely assume that isotope effects (IEs) result only from degradation. Experimental results on MTBE behavior in diffusive volatilization and dynamic vapor extraction show measurable changes in the isotope ratios of the MTBE remaining in the aqueous or nonaqueous phase liquid (NAPL) matrix. A conceptual model for interpretation of those IEs is proposed, based on the physics of liquid−air partitioning. Normal or inverse IEs were observed for different volatilization scenarios. The range of carbon enrichment factors (ε) was from +0.7‰ (gasoline vapor extraction) to −1‰ (diffusive volatilization of MTBE from gasoline), the range of hydrogen ε was from +7‰ (gasoline vapor extraction) to −12‰ (air sparging of aqueous MTBE). The observed IEs are lower than those associated with MTBE degradation. However, under a realistic scenario for MTBE vapor removal, their magnitude is within the detection limits of CSIA. The potential for interference of those IEs is primarily in confusing the interpretation of samples with a small extent of fractionation and where only carbon CSIA data are available. The IEs resulting from volatilization and biodegradation, respectively, can be separated by combined carbon and hydrogen 2D-CSIA.
- 12 September 2007
- Published by Springer Nature in Reviews in Environmental Science and Bio/Technology
- Vol. 7 (1) , 79-91
Modern geochemical and molecular tools for monitoring in-situ biodegradation of MTBE and TBA
- 12 September 2007
- Published by Springer Nature in Reviews in Environmental Science and Bio/Technology
- Vol. 7 (1) , 79-91
Modern geochemical and molecular tools for monitoring in-situ biodegradation of MTBE and TBA