Diego Ghezzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Diego Ghezzi has a total of 216 co-authors. Here are the top co-authors by number of shared publications:
Elodie Geneviève Zollinger
Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
12 shared publications- Marta Jole Ildelfonsa Airaghi Leccardi
Nano-Cybernetic Biotrek, Media Lab, Massachusetts Institute of Technology, Cambridge, USA
11 shared publications - Maria Rosa Antognazza
Istituto Italiano di Tecnologia
8 shared publications - Alessandra Pedrocchi
NearLab, Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy
7 shared publications Eleonora Borda
Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
7 shared publications- Giancarlo Ferrigno
Politecnico di Milano
7 shared publications
Latest Publications
- Open Access
- 10 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8537
Resting-state electroretinography reveals pathological retinal oscillations in retinitis pigmentosa mice and patients
Retinal remodeling occurs in both retinitis pigmentosa and age-related macular degeneration. However, it is still unknown whether spared retinal circuits are also functionally altered. Functional changes have been observed in animal models of retinitis pigmentosa, including the emergence of bursting oscillatory activity in retinal ganglion cells. Yet, comparable oscillatory activity, or other functional alterations, has not been demonstrated in patients. To address this gap, here we report a non-invasive corneal neurotechnology measuring in-vivo resting-state electroretinography and analyzing its frequency content and temporal characteristics to identify biomarkers of functional remodeling. We document that retinal remodeling induces bursting oscillatory activity in-vivo in retinitis pigmentosa mouse models and translate these results to patients. Moreover, we showed in mice that bursting oscillatory activity can be pharmacologically modulated in-vivo. Furthermore, reducing this oscillatory activity increases retinal excitability to electrical stimulation. These results are crucial for a better understanding of retinal degeneration and contribute to sight restoration efforts.
- 10 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8537
Open AccessResting-state electroretinography reveals pathological retinal oscillations in retinitis pigmentosa mice and patients
Retinal remodeling occurs in both retinitis pigmentosa and age-related macular degeneration. However, it is still unknown whether spared retinal circuits are also functionally altered. Functional changes have been observed in animal models of retinitis pigmentosa, including the emergence of bursting oscillatory activity in retinal ganglion cells. Yet, comparable oscillatory activity, or other functional alterations, has not been demonstrated in patients. To address this gap, here we report a non-invasive corneal neurotechnology measuring in-vivo resting-state electroretinography and analyzing its frequency content and temporal characteristics to identify biomarkers of functional remodeling. We document that retinal remodeling induces bursting oscillatory activity in-vivo in retinitis pigmentosa mouse models and translate these results to patients. Moreover, we showed in mice that bursting oscillatory activity can be pharmacologically modulated in-vivo. Furthermore, reducing this oscillatory activity increases retinal excitability to electrical stimulation. These results are crucial for a better understanding of retinal degeneration and contribute to sight restoration efforts.
- Open Access
Wide visual angle enhances social interaction in a realistic virtual reality environment under simulated artificial vision
Objective . Social interaction largely relies on visual perception. Yet artificial vision research has primarily focused on navigation and object recognition while assessment of social interaction remains scarce. This study investigates how the visual field size in simulated artificial vision impacts social perception in a virtual reality setting. Approach . We assessed the impact of visual field size in sighted participants experiencing simulated artificial vision in a medical practice across three social task categories: indoor identification (searching for an empty chair, identification of body orientation, body appearance, facial expressions, relationship type, role and interpretation of body language), locomotion (tracking and following a moving person), and outdoor observation (person recognition in a cluttered outdoor environment). Main Results . A wide range of social perception and locomotion tasks in structured indoor environments can be completed with a 45° field of view in simulated artificial vision. Compared to 20°, the broader visual field not only enhances accuracy but also enables faster task execution and a more precise assessment of one’s own performance. Although the benefits of an expanded visual field are limited in cluttered environments, a 45° visual field represents a clear advantage in social contexts. Significance . These findings highlight the importance of an expanded visual field for artificial vision users in social settings, reinforcing its role in enhancing social cue processing and the ability to follow people. By integrating simulated artificial vision within an immersive virtual reality framework, this study bridges the gap between controlled experimental paradigms and real-world needs and challenges.
Open AccessWide visual angle enhances social interaction in a realistic virtual reality environment under simulated artificial vision
Objective . Social interaction largely relies on visual perception. Yet artificial vision research has primarily focused on navigation and object recognition while assessment of social interaction remains scarce. This study investigates how the visual field size in simulated artificial vision impacts social perception in a virtual reality setting. Approach . We assessed the impact of visual field size in sighted participants experiencing simulated artificial vision in a medical practice across three social task categories: indoor identification (searching for an empty chair, identification of body orientation, body appearance, facial expressions, relationship type, role and interpretation of body language), locomotion (tracking and following a moving person), and outdoor observation (person recognition in a cluttered outdoor environment). Main Results . A wide range of social perception and locomotion tasks in structured indoor environments can be completed with a 45° field of view in simulated artificial vision. Compared to 20°, the broader visual field not only enhances accuracy but also enables faster task execution and a more precise assessment of one’s own performance. Although the benefits of an expanded visual field are limited in cluttered environments, a 45° visual field represents a clear advantage in social contexts. Significance . These findings highlight the importance of an expanded visual field for artificial vision users in social settings, reinforcing its role in enhancing social cue processing and the ability to follow people. By integrating simulated artificial vision within an immersive virtual reality framework, this study bridges the gap between controlled experimental paradigms and real-world needs and challenges.
- 6 November 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (6) , 066005
Wide-angle simulated artificial vision enhances spatial navigation and object interaction in a naturalistic environment
Objective. Vision restoration approaches, such as prosthetics and optogenetics, provide visual perception to blind individuals in clinical settings. Yet their effectiveness in daily life remains a challenge. Stereotyped quantitative tests used in clinical trials often fail to translate into practical, everyday applications. On the one hand, assessing real-life benefits during clinical trials is complicated by environmental complexity, reproducibility issues, and safety concerns. On the other hand, predicting behavioral benefits of restorative therapies in naturalistic environments may be a crucial step before starting clinical trials to minimize patient discomfort and unmet expectations. Approach. To address this, we leverage advancements in virtual reality technology to conduct a fully immersive and ecologically valid task within a physical artificial street environment. As a case study, we assess the impact of the visual field size in simulated artificial vision for common outdoor tasks. Main results. We show that a wide visual angle (45°) enhances participants’ ability to navigate and solve tasks more effectively, safely, and efficiently. Moreover, it promotes their learning and generalization capability. Concurrently, it changes the visual exploration behavior and facilitates a more accurate mental representation of the environment. Further increasing the visual angle beyond this value does not yield significant additional improvements in most metrics. Significance. We present a methodology combining augmented reality with a naturalistic environment, enabling participants to perceive the world as patients with retinal implants would and to interact physically with it. Combining augmented reality in naturalistic environments is a valuable framework for low vision and vision restoration research.
- 6 November 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (6) , 066005
Wide-angle simulated artificial vision enhances spatial navigation and object interaction in a naturalistic environment
Objective. Vision restoration approaches, such as prosthetics and optogenetics, provide visual perception to blind individuals in clinical settings. Yet their effectiveness in daily life remains a challenge. Stereotyped quantitative tests used in clinical trials often fail to translate into practical, everyday applications. On the one hand, assessing real-life benefits during clinical trials is complicated by environmental complexity, reproducibility issues, and safety concerns. On the other hand, predicting behavioral benefits of restorative therapies in naturalistic environments may be a crucial step before starting clinical trials to minimize patient discomfort and unmet expectations. Approach. To address this, we leverage advancements in virtual reality technology to conduct a fully immersive and ecologically valid task within a physical artificial street environment. As a case study, we assess the impact of the visual field size in simulated artificial vision for common outdoor tasks. Main results. We show that a wide visual angle (45°) enhances participants’ ability to navigate and solve tasks more effectively, safely, and efficiently. Moreover, it promotes their learning and generalization capability. Concurrently, it changes the visual exploration behavior and facilitates a more accurate mental representation of the environment. Further increasing the visual angle beyond this value does not yield significant additional improvements in most metrics. Significance. We present a methodology combining augmented reality with a naturalistic environment, enabling participants to perceive the world as patients with retinal implants would and to interact physically with it. Combining augmented reality in naturalistic environments is a valuable framework for low vision and vision restoration research.
- Open Access
- 24 June 2024
- Published by Elsevier in Diamond and Related Materials
- Vol. 148
In vivo recording of visually evoked potentials with novel full diamond ECoG implants
- 24 June 2024
- Published by Elsevier in Diamond and Related Materials
- Vol. 148
Open AccessIn vivo recording of visually evoked potentials with novel full diamond ECoG implants
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 679-690
A Frequency-Switching Inductive Power Transfer System for Wireless, Miniaturised and Large-Scale Neural Interfaces
Three-coil inductive power transfer is the state-of-the-art solution to power multiple miniaturised neural implants. However, the maximum delivered power is limited by the efficiency of the powering link and safety constrains. Here we propose a frequency-switching inductive link, where the passive resonator normally used in a three-coil link is replaced by an active resonator. It receives power from the external transmitter via a two-coil inductive link at the low frequency of 13.56 MHz. Then, it switches the operating frequency to the higher frequency of 433.92 MHz through a dedicated circuitry. Last, it transmits power to 1024 miniaturised implants via a three-coil inductive link using an array of 37 focusing resonators for a brain coverage of 163.84 mm $^{2}$ . Our simulations reported a power transfer efficiency of 0.013 $\%$ and a maximum power delivered to the load of 1970 $\mu$ W under safety-constrains, which are respectively two orders of magnitude and more than six decades higher compared to an equivalent passive three-coil link. The frequency-switching inductive system is a scalable and highly versatile solution for wireless, miniaturised and large-scale neural interfaces.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 679-690
A Frequency-Switching Inductive Power Transfer System for Wireless, Miniaturised and Large-Scale Neural Interfaces
Three-coil inductive power transfer is the state-of-the-art solution to power multiple miniaturised neural implants. However, the maximum delivered power is limited by the efficiency of the powering link and safety constrains. Here we propose a frequency-switching inductive link, where the passive resonator normally used in a three-coil link is replaced by an active resonator. It receives power from the external transmitter via a two-coil inductive link at the low frequency of 13.56 MHz. Then, it switches the operating frequency to the higher frequency of 433.92 MHz through a dedicated circuitry. Last, it transmits power to 1024 miniaturised implants via a three-coil inductive link using an array of 37 focusing resonators for a brain coverage of 163.84 mm $^{2}$ . Our simulations reported a power transfer efficiency of 0.013 $\%$ and a maximum power delivered to the load of 1970 $\mu$ W under safety-constrains, which are respectively two orders of magnitude and more than six decades higher compared to an equivalent passive three-coil link. The frequency-switching inductive system is a scalable and highly versatile solution for wireless, miniaturised and large-scale neural interfaces.
- Open Access
- 27 January 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
An actor-model framework for visual sensory encoding
A fundamental challenge in neuroengineering is determining a proper artificial input to a sensory system that yields the desired perception. In neuroprosthetics, this process is known as artificial sensory encoding, and it holds a crucial role in prosthetic devices restoring sensory perception in individuals with disabilities. For example, in visual prostheses, one key aspect of artificial image encoding is to downsample images captured by a camera to a size matching the number of inputs and resolution of the prosthesis. Here, we show that downsampling an image using the inherent computation of the retinal network yields better performance compared to learning-free downsampling methods. We have validated a learning-based approach (actor-model framework) that exploits the signal transformation from photoreceptors to retinal ganglion cells measured in explanted mouse retinas. The actor-model framework generates downsampled images eliciting a neuronal response in-silico and ex-vivo with higher neuronal reliability than the one produced by a learning-free approach. During the learning process, the actor network learns to optimize contrast and the kernel’s weights. This methodological approach might guide future artificial image encoding strategies for visual prostheses. Ultimately, this framework could be applicable for encoding strategies in other sensory prostheses such as cochlear or limb.
- 27 January 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Open AccessAn actor-model framework for visual sensory encoding
A fundamental challenge in neuroengineering is determining a proper artificial input to a sensory system that yields the desired perception. In neuroprosthetics, this process is known as artificial sensory encoding, and it holds a crucial role in prosthetic devices restoring sensory perception in individuals with disabilities. For example, in visual prostheses, one key aspect of artificial image encoding is to downsample images captured by a camera to a size matching the number of inputs and resolution of the prosthesis. Here, we show that downsampling an image using the inherent computation of the retinal network yields better performance compared to learning-free downsampling methods. We have validated a learning-based approach (actor-model framework) that exploits the signal transformation from photoreceptors to retinal ganglion cells measured in explanted mouse retinas. The actor-model framework generates downsampled images eliciting a neuronal response in-silico and ex-vivo with higher neuronal reliability than the one produced by a learning-free approach. During the learning process, the actor network learns to optimize contrast and the kernel’s weights. This methodological approach might guide future artificial image encoding strategies for visual prostheses. Ultimately, this framework could be applicable for encoding strategies in other sensory prostheses such as cochlear or limb.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 580-591
A Wearable Real-Time System for Simultaneous Wireless Power and Data Transmission to Cortical Visual Prosthesis
Wireless, miniaturised and distributed neural interfaces are emerging neurotechnologies. Although extensive research efforts contribute to their technological advancement, the need for real-time systems enabling simultaneous wireless information and power transfer toward distributed neural implants remains crucial. Here we present a complete wearable system including a software for real-time image capturing, processing and digital data transfer; an hardware for high radiofrequency generation and modulation via amplitude shift keying; and a 3-coil inductive link adapt to operate with multiple miniaturised receivers. The system operates in real-time with a maximum frame rate of 20 Hz, reconstructing each frame with a matrix of 32 × 32 pixels. The device generates a carrier frequency of 433.92 MHz. It transmits the highest power of 32 dBm with a data rate of 6 Mbps and a variable modulation index as low as 8 $\%$ , thus potentially enabling wireless communication with 1024 miniaturised and distributed intracortical microstimulators. The system is primarily conceived as an external wearable device for distributed cortical visual prosthesis covering a visual field of 20 $^{\circ }$ . At the same time, it is modular and versatile, being suitable for multiple applications requiring simultaneous wireless information and power transfer to large-scale neural interfaces.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (3) , 580-591
A Wearable Real-Time System for Simultaneous Wireless Power and Data Transmission to Cortical Visual Prosthesis
Wireless, miniaturised and distributed neural interfaces are emerging neurotechnologies. Although extensive research efforts contribute to their technological advancement, the need for real-time systems enabling simultaneous wireless information and power transfer toward distributed neural implants remains crucial. Here we present a complete wearable system including a software for real-time image capturing, processing and digital data transfer; an hardware for high radiofrequency generation and modulation via amplitude shift keying; and a 3-coil inductive link adapt to operate with multiple miniaturised receivers. The system operates in real-time with a maximum frame rate of 20 Hz, reconstructing each frame with a matrix of 32 × 32 pixels. The device generates a carrier frequency of 433.92 MHz. It transmits the highest power of 32 dBm with a data rate of 6 Mbps and a variable modulation index as low as 8 $\%$ , thus potentially enabling wireless communication with 1024 miniaturised and distributed intracortical microstimulators. The system is primarily conceived as an external wearable device for distributed cortical visual prosthesis covering a visual field of 20 $^{\circ }$ . At the same time, it is modular and versatile, being suitable for multiple applications requiring simultaneous wireless information and power transfer to large-scale neural interfaces.
- Open Access
An actor-model framework for visual sensory encoding
A fundamental challenge in neuroengineering is determining a proper input to a sensory system that yields the desired functional output. In neuroprosthetics, this process is known as sensory encoding, and it holds a crucial role in prosthetic devices restoring sensory perception in individuals with disabilities. For example, in visual prostheses, one key aspect of image encoding is to down-sample the images captured by a camera to a size matching the number of inputs and resolution of the prosthesis. Here, we show that down-sampling an image using the inherent computation of the retinal network yields better performance compared to a learning-free down-sampling encoding. We validated a learning-based approach (actor-model framework) that exploits the signal transformation from photoreceptors to retinal ganglion cells measured in explanted retinas. The actor-model framework generates down-sampled images eliciting a neuronal response in-silico and ex-vivo with higher neuronal reliability to the one produced by original images compared to a learning-free approach (i.e. pixel averaging). In addition, the actor-model learned that contrast is a crucial feature for effective down-sampling. This methodological approach could serve as a template for future image encoding strategies. Ultimately, it can be exploited to improve encoding strategies in visual prostheses or other sensory prostheses such as cochlear or limb.
Open AccessAn actor-model framework for visual sensory encoding
A fundamental challenge in neuroengineering is determining a proper input to a sensory system that yields the desired functional output. In neuroprosthetics, this process is known as sensory encoding, and it holds a crucial role in prosthetic devices restoring sensory perception in individuals with disabilities. For example, in visual prostheses, one key aspect of image encoding is to down-sample the images captured by a camera to a size matching the number of inputs and resolution of the prosthesis. Here, we show that down-sampling an image using the inherent computation of the retinal network yields better performance compared to a learning-free down-sampling encoding. We validated a learning-based approach (actor-model framework) that exploits the signal transformation from photoreceptors to retinal ganglion cells measured in explanted retinas. The actor-model framework generates down-sampled images eliciting a neuronal response in-silico and ex-vivo with higher neuronal reliability to the one produced by original images compared to a learning-free approach (i.e. pixel averaging). In addition, the actor-model learned that contrast is a crucial feature for effective down-sampling. This methodological approach could serve as a template for future image encoding strategies. Ultimately, it can be exploited to improve encoding strategies in visual prostheses or other sensory prostheses such as cochlear or limb.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Magazine
- Vol. 15 (2) , 34-40
Challenges for Miniaturized Neurostimulators: Design of wireless Bio/CMOS interfaces for brain stimulation
Neurostimulation addresses neurological and mental disorders such as Parkinson’s, blindness, deafness, and depression. Miniaturized, wireless, and free-floating neurostimulators improve spatial resolution, increase the surface of coverage, and reduce chronic trauma. Several techniques have been proposed over the last few years. This article focuses on some selected approaches that have been shown to be effective and promising.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Magazine
- Vol. 15 (2) , 34-40
Challenges for Miniaturized Neurostimulators: Design of wireless Bio/CMOS interfaces for brain stimulation
Neurostimulation addresses neurological and mental disorders such as Parkinson’s, blindness, deafness, and depression. Miniaturized, wireless, and free-floating neurostimulators improve spatial resolution, increase the surface of coverage, and reduce chronic trauma. Several techniques have been proposed over the last few years. This article focuses on some selected approaches that have been shown to be effective and promising.
- 9 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 495-506
Changes Over Time in the Electrode/Brain Interface Impedance: An Ex-Vivo Study
Closed-loop neural implants based on continuous brain activity recording and intracortical microstimulation are extremely effective and promising devices to monitor and address many neurodegenerative diseases. The efficiency of these devices depends on the robustness of the designed circuits which rely on precise electrical equivalent models of the electrode/brain interface. This is true in the case of amplifiers for differential recording, voltage or current drivers for neurostimulation, and potentiostats for electrochemical bio-sensing. This is of paramount importance, especially for the next generation of wireless and ultra-miniaturised CMOS neural implants. Circuits are usually designed and optimized considering the electrode/brain impedance with a simple electrical equivalent model whose parameters are stationary over time. However, the electrode/brain interfacial impedance varies simultaneously in frequency and in time after implantation. The aim of this study is to monitor the impedance changes occurring on microelectrodes inserted in ex-vivo porcine brains to derive an opportune electrode/brain model describing the system and its evolution in time. In particular, impedance spectroscopy measurements have been performed for 144 hours to characterise the evolution of the electrochemical behaviour in two different setups analysing both the neural recording and the chronic stimulation scenarios. Then, different equivalent electrical circuit models have been proposed to describe the system. Results showed a decrease in the resistance to charge transfer, attributed to the interaction between biological material and the electrode surface. These findings are crucial to support circuit designers in the field of neural implants.
- 9 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 495-506
Changes Over Time in the Electrode/Brain Interface Impedance: An Ex-Vivo Study
Closed-loop neural implants based on continuous brain activity recording and intracortical microstimulation are extremely effective and promising devices to monitor and address many neurodegenerative diseases. The efficiency of these devices depends on the robustness of the designed circuits which rely on precise electrical equivalent models of the electrode/brain interface. This is true in the case of amplifiers for differential recording, voltage or current drivers for neurostimulation, and potentiostats for electrochemical bio-sensing. This is of paramount importance, especially for the next generation of wireless and ultra-miniaturised CMOS neural implants. Circuits are usually designed and optimized considering the electrode/brain impedance with a simple electrical equivalent model whose parameters are stationary over time. However, the electrode/brain interfacial impedance varies simultaneously in frequency and in time after implantation. The aim of this study is to monitor the impedance changes occurring on microelectrodes inserted in ex-vivo porcine brains to derive an opportune electrode/brain model describing the system and its evolution in time. In particular, impedance spectroscopy measurements have been performed for 144 hours to characterise the evolution of the electrochemical behaviour in two different setups analysing both the neural recording and the chronic stimulation scenarios. Then, different equivalent electrical circuit models have been proposed to describe the system. Results showed a decrease in the resistance to charge transfer, attributed to the interaction between biological material and the electrode surface. These findings are crucial to support circuit designers in the field of neural implants.