Rafael Lacerda Furlanetto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rafael Lacerda Furlanetto has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Robert Ritch
Moise and Chella Safra Advanced Ocular Imaging Laboratory, Einhorn Clinical Research Center, New York Eye and Ear Infirmary of Mount Sinai
7 shared publicationsJeffrey M. Liebmann
Bernard and Shirlee Brown Glaucoma Research Laboratory, Harkness Eye Institute, Columbia University Medical Center, New York
6 shared publicationsSung Chul Park
Department of Ophthalmology, Manhattan Eye, Ear and Throat Hospital
3 shared publications- Syril Dorairaj
Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
3 shared publications - Augusto Paranhos Junior
Department of Ophthalmology and Visual Science, Glaucoma Service, Universidade Federal de São Paulo, São Paulo, Brazil
2 shared publications Camila F Netto
Moise and Chella Safra Advanced Ocular Imaging Laboratory, Einhorn Clinical Research Center, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA
2 shared publications
Latest Publications
- Open Access
- 23 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0194038
Structural and functional analyses of the optic nerve and lateral geniculate nucleus in glaucoma
To analyze the correlation between structural characteristics of intraorbital optic nerve (ION) and lateral geniculate nucleus (LGN) measured by 3-Tesla magnetic resonance imaging (3T MRI), and the severity of glaucomatous damage. In this cross-sectional study, 41 glaucoma patients and 12 age- and sex-matched controls underwent standard automated perimetry (SAP) and frequency doubling technology (FDT) as functional evaluation; optic disc stereophotograph, spectral-domain optical coherence tomography (OCT) and confocal scanning laser tomography as ocular structural evaluation; and 3T MRI. Structure-structure and structure-function correlation were performed using bootstrap resampling method for clustered data. The ION mean diameter and cross-sectional area were different between glaucoma and control groups at 5mm and 10mm (all, p≤0.011) from the globe, but not at 15mm (both, p≥0.067). LGN height was significantly lower in glaucoma group (p = 0.005). OCT rim area and functional parameters (SAP and FDT) correlated significantly with all ION segments, showing stronger correlations at 10 and 15 mm. ION parameters at 10 and 15 mm presented mild-to-moderate correlation with OCT peripapillary nerve fiber layer thickness, and ION at 15mm had mild association with the neuroretinal rim area on stereophotographs. Although LGN height was significantly smaller in glaucoma group (p = 0.005), LGN parameters were not associated with any ocular structural or functional parameter. Assessment of central and peripheral nervous systems using 3T MRI confirmed that glaucoma patients had smaller ION dimensions and LGN height compared to the control group. In general, ION dimensions presented mild to moderate correlations with functional and ocular structural parameters. Although ION had significant correlations at any distance from the eye, the ION distal locations correlated better with OCT results and functional parameters. However, LGN parameters were not associated with functional or ocular structural parameters.
- 23 March 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (3) , e0194038
Open AccessStructural and functional analyses of the optic nerve and lateral geniculate nucleus in glaucoma
To analyze the correlation between structural characteristics of intraorbital optic nerve (ION) and lateral geniculate nucleus (LGN) measured by 3-Tesla magnetic resonance imaging (3T MRI), and the severity of glaucomatous damage. In this cross-sectional study, 41 glaucoma patients and 12 age- and sex-matched controls underwent standard automated perimetry (SAP) and frequency doubling technology (FDT) as functional evaluation; optic disc stereophotograph, spectral-domain optical coherence tomography (OCT) and confocal scanning laser tomography as ocular structural evaluation; and 3T MRI. Structure-structure and structure-function correlation were performed using bootstrap resampling method for clustered data. The ION mean diameter and cross-sectional area were different between glaucoma and control groups at 5mm and 10mm (all, p≤0.011) from the globe, but not at 15mm (both, p≥0.067). LGN height was significantly lower in glaucoma group (p = 0.005). OCT rim area and functional parameters (SAP and FDT) correlated significantly with all ION segments, showing stronger correlations at 10 and 15 mm. ION parameters at 10 and 15 mm presented mild-to-moderate correlation with OCT peripapillary nerve fiber layer thickness, and ION at 15mm had mild association with the neuroretinal rim area on stereophotographs. Although LGN height was significantly smaller in glaucoma group (p = 0.005), LGN parameters were not associated with any ocular structural or functional parameter. Assessment of central and peripheral nervous systems using 3T MRI confirmed that glaucoma patients had smaller ION dimensions and LGN height compared to the control group. In general, ION dimensions presented mild to moderate correlations with functional and ocular structural parameters. Although ION had significant correlations at any distance from the eye, the ION distal locations correlated better with OCT results and functional parameters. However, LGN parameters were not associated with functional or ocular structural parameters.
- 1 December 2017
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 26 (12) , 1095-1100
Relationship Between Optic Nerve Head Drusen Volume and Structural and Functional Optic Nerve Damage
Purpose: The purpose of this study is to assess the relationships between optic nerve head drusen (ONHD) volume, retinal nerve fiber layer (RNFL) thickness and visual field (VF) loss. Methods: Patients with ONHD and no other ocular or systemic conditions that can affect RNFL or VF were enrolled. Serial enhanced depth imaging (EDI) optical coherence tomography (OCT) B-scans of the optic nerve head (interval between scans, ~30 μm) were obtained from each participant. ONHD volume was calculated for each eye by delineating the ONHD masses in each OCT B-scan using 3-dimensional reconstruction software. Results: A total of 47 eyes (28 patients) with ONHD were included (mean age, 57±16 y). ONHD volume varied considerably [0.265±0.227 (range, 0.005 to 0.855)] mm3. Linear and quadratic regression analyses demonstrated that ONHD volume is significantly associated with both global average RNFL thickness (linear R 2=0.531, quadratic R 2=0.557; PR 2=0.519, quadratic R 2=0.522; PP<0.001). RNFL defects were detected in 10 of the 19 eyes with no VF defects. RNFL defects were detected in all 28 eyes with VF defects. Conclusions: ONHD volume generally correlates with structural and functional optic nerve damage.
- 1 December 2017
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 26 (12) , 1095-1100
Relationship Between Optic Nerve Head Drusen Volume and Structural and Functional Optic Nerve Damage
Purpose: The purpose of this study is to assess the relationships between optic nerve head drusen (ONHD) volume, retinal nerve fiber layer (RNFL) thickness and visual field (VF) loss. Methods: Patients with ONHD and no other ocular or systemic conditions that can affect RNFL or VF were enrolled. Serial enhanced depth imaging (EDI) optical coherence tomography (OCT) B-scans of the optic nerve head (interval between scans, ~30 μm) were obtained from each participant. ONHD volume was calculated for each eye by delineating the ONHD masses in each OCT B-scan using 3-dimensional reconstruction software. Results: A total of 47 eyes (28 patients) with ONHD were included (mean age, 57±16 y). ONHD volume varied considerably [0.265±0.227 (range, 0.005 to 0.855)] mm3. Linear and quadratic regression analyses demonstrated that ONHD volume is significantly associated with both global average RNFL thickness (linear R 2=0.531, quadratic R 2=0.557; PR 2=0.519, quadratic R 2=0.522; PP<0.001). RNFL defects were detected in 10 of the 19 eyes with no VF defects. RNFL defects were detected in all 28 eyes with VF defects. Conclusions: ONHD volume generally correlates with structural and functional optic nerve damage.
- Open Access
- 21 July 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (7) , e0180128
In vivo analysis of glaucoma-related features within the optic nerve head using enhanced depth imaging optical coherence tomography
Structural differences between optic nerve head (ONH) parameters in glaucomatous and non-glaucomatous eyes has been documented, however the association between such parameters in patients with different disease stages is yet to be elucidated. We investigated the relationship between different laminar and prelaminar ONH structures using enhanced depth imaging spectral-domain optical coherence tomography (EDI OCT) in a population with and without glaucoma. In this observational case-control study, we prospectively enrolled healthy individuals and glaucomatous patients with different disease stages. All participants underwent EDI OCT imaging (Heidelberg Engineering). Following ONH parameters were measured on serial vertical B-scans by two examiners masked to patient’s clinical data: lamina cribrosa (LC) and prelaminar neural tissue (PLNT) thicknesses, Bruch’s membrane opening (BMO) and cup depth. Associations between cup depth, and laminar and prelaminar parameters were evaluated controlling for possible confounding factors such as axial length and disc size. Sixty-four eyes of 64 patients were included (30 with glaucoma and 34 controls). Eyes with glaucoma had significantly lower mean LC and PLNT thickness, and greater mean cup depth than controls (p2 = 0.158, p = 0.029). In addition, LC thickness correlated significantly with cup depth (R2 = 0.135, p = 0.045). Eyes with thinner LCs presented deeper cups. Overall, cup depth and BMO had the best and LC thickness had the worst intraobserver and interobserver reproducibility grading. In conclusion, significant associations were seen between cup depth, LC and PLNT thickness. Eyes with deeper cups not only had less neural tissue, but also thinner LCs, independent of disc size and axial length. Best reproducibility was found for prelaminar parameters compared to deeper ONH structures.
- 21 July 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (7) , e0180128
Open AccessIn vivo analysis of glaucoma-related features within the optic nerve head using enhanced depth imaging optical coherence tomography
Structural differences between optic nerve head (ONH) parameters in glaucomatous and non-glaucomatous eyes has been documented, however the association between such parameters in patients with different disease stages is yet to be elucidated. We investigated the relationship between different laminar and prelaminar ONH structures using enhanced depth imaging spectral-domain optical coherence tomography (EDI OCT) in a population with and without glaucoma. In this observational case-control study, we prospectively enrolled healthy individuals and glaucomatous patients with different disease stages. All participants underwent EDI OCT imaging (Heidelberg Engineering). Following ONH parameters were measured on serial vertical B-scans by two examiners masked to patient’s clinical data: lamina cribrosa (LC) and prelaminar neural tissue (PLNT) thicknesses, Bruch’s membrane opening (BMO) and cup depth. Associations between cup depth, and laminar and prelaminar parameters were evaluated controlling for possible confounding factors such as axial length and disc size. Sixty-four eyes of 64 patients were included (30 with glaucoma and 34 controls). Eyes with glaucoma had significantly lower mean LC and PLNT thickness, and greater mean cup depth than controls (p2 = 0.158, p = 0.029). In addition, LC thickness correlated significantly with cup depth (R2 = 0.135, p = 0.045). Eyes with thinner LCs presented deeper cups. Overall, cup depth and BMO had the best and LC thickness had the worst intraobserver and interobserver reproducibility grading. In conclusion, significant associations were seen between cup depth, LC and PLNT thickness. Eyes with deeper cups not only had less neural tissue, but also thinner LCs, independent of disc size and axial length. Best reproducibility was found for prelaminar parameters compared to deeper ONH structures.
- 28 September 2016
- Published by BMJ in British Journal of Ophthalmology
- Vol. 101 (6) , 808-813
Characteristics and variations of in vivo Schlemm's canal and collector channel microstructures in enhanced-depth imaging optical coherence tomography
Background/aims To characterise in vivo Schlemm's canal (SC) and collector channels (CC) microstructures using enhanced-depth imaging (EDI) optical coherence tomography (OCT). Methods Serial horizontal EDI OCT B-scans (81 scans, 15×5° rectangle) were prospectively obtained in the nasal and temporal limbus. SC cross-sectional area (CSA) was measured by delineating its lumen in each B-scan. CCs connected to SC were counted. SC CSA and the number of CCs were compared between the nasal and temporal areas. Results Eleven eyes (11 normal subjects) were included (mean age, 28±5 years). SC and CCs were clearly demarcated in EDI OCT B-scans with excellent repeatability and reproducibility (intraclass correlation coefficients, 0.830–0.886 and 0.793, respectively; all p2 (average, 3514±1235 µm2), and among different regions of the same eye with coefficient of variation in each eye ranging from 23% to 46% (average, 32±7%). The number of CCs in the analysed area also varied considerably among subjects, ranging from 5 to 11 (average, 8.73±1.85). The mean SC CSA (3839±1402 µm2 vs 3189±1209 µm2; p=0.033) and number of CCs (5.5±1.4 vs 3.3±1.1; p=0.001) were significantly greater nasally than temporally. The mean SC CSA was significantly correlated with the number of CCs (r=0.635, p=0.036). Conclusions High-quality images of the aqueous outflow pathway can be obtained with a clinical device, avoiding postacquisition processing. In vivo SC and CC microstructures vary considerably among individuals and regions. SC tends to be larger in regions with more CCs.
- 28 September 2016
- Published by BMJ in British Journal of Ophthalmology
- Vol. 101 (6) , 808-813
Characteristics and variations of in vivo Schlemm's canal and collector channel microstructures in enhanced-depth imaging optical coherence tomography
Background/aims To characterise in vivo Schlemm's canal (SC) and collector channels (CC) microstructures using enhanced-depth imaging (EDI) optical coherence tomography (OCT). Methods Serial horizontal EDI OCT B-scans (81 scans, 15×5° rectangle) were prospectively obtained in the nasal and temporal limbus. SC cross-sectional area (CSA) was measured by delineating its lumen in each B-scan. CCs connected to SC were counted. SC CSA and the number of CCs were compared between the nasal and temporal areas. Results Eleven eyes (11 normal subjects) were included (mean age, 28±5 years). SC and CCs were clearly demarcated in EDI OCT B-scans with excellent repeatability and reproducibility (intraclass correlation coefficients, 0.830–0.886 and 0.793, respectively; all p2 (average, 3514±1235 µm2), and among different regions of the same eye with coefficient of variation in each eye ranging from 23% to 46% (average, 32±7%). The number of CCs in the analysed area also varied considerably among subjects, ranging from 5 to 11 (average, 8.73±1.85). The mean SC CSA (3839±1402 µm2 vs 3189±1209 µm2; p=0.033) and number of CCs (5.5±1.4 vs 3.3±1.1; p=0.001) were significantly greater nasally than temporally. The mean SC CSA was significantly correlated with the number of CCs (r=0.635, p=0.036). Conclusions High-quality images of the aqueous outflow pathway can be obtained with a clinical device, avoiding postacquisition processing. In vivo SC and CC microstructures vary considerably among individuals and regions. SC tends to be larger in regions with more CCs.
- 1 March 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (3) , 2059-64
Lamina Cribrosa Depth in Different Stages of Glaucoma
Purpose: To compare lamina cribrosa (LC) depth between normal eyes and eyes with different stages of treated glaucoma. Methods: Serial enhanced depth imaging (EDI) optical coherence tomography (OCT) B-scans of the optic nerve head were obtained. To generate the mean LC depth for each eye, LC depths were measured in 11 equally spaced horizontal B-scans and averaged. The mean LC depth was compared among normal, pre-perimetric, mild-to-moderate, and severe glaucoma groups. Among patients with visual field (VF) loss, correlation analysis was performed 1) between mean LC depth and VF mean deviation (MD), and 2) between mean LC depth and retinal nerve fiber layer (RNFL) thickness. Results: 86 normal eyes (age, 56±14 years), 47 pre-perimetric glaucoma eyes (age, 60±16 years), 55 mild-to-moderate glaucomatous eyes (age, 59±16 years; VF MD, -6.0±3.2 dB), and 60 severe glaucomatous eyes (age, 59±17 years; VF MD, -19.7±6.1 dB) were included. Mean LC depth was significantly greater in pre-perimetric glaucoma than in normal eyes (390 vs. 344 µm, P=0.004) and in mild-to-moderate than in pre-perimetric glaucoma eyes (448 vs. 390 µm, P=0.001). However, no significant difference was observed between mild-to-moderate and severe glaucoma eyes (448 vs. 437 µm, P=0.52). No correlation was observed between LC depth and VF MD (P=0.56) or RNFL thickness (P=0.90) in glaucomatous eyes with VF loss. Conclusions: In treated glaucoma, posterior LC displacement occurs mostly in the pre-perimetric and mild-to-moderate glaucoma stages. This warrants further investigation of LC depth as a parameter to monitor glaucoma progression in the early stages.
- 1 March 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (3) , 2059-64
Lamina Cribrosa Depth in Different Stages of Glaucoma
Purpose: To compare lamina cribrosa (LC) depth between normal eyes and eyes with different stages of treated glaucoma. Methods: Serial enhanced depth imaging (EDI) optical coherence tomography (OCT) B-scans of the optic nerve head were obtained. To generate the mean LC depth for each eye, LC depths were measured in 11 equally spaced horizontal B-scans and averaged. The mean LC depth was compared among normal, pre-perimetric, mild-to-moderate, and severe glaucoma groups. Among patients with visual field (VF) loss, correlation analysis was performed 1) between mean LC depth and VF mean deviation (MD), and 2) between mean LC depth and retinal nerve fiber layer (RNFL) thickness. Results: 86 normal eyes (age, 56±14 years), 47 pre-perimetric glaucoma eyes (age, 60±16 years), 55 mild-to-moderate glaucomatous eyes (age, 59±16 years; VF MD, -6.0±3.2 dB), and 60 severe glaucomatous eyes (age, 59±17 years; VF MD, -19.7±6.1 dB) were included. Mean LC depth was significantly greater in pre-perimetric glaucoma than in normal eyes (390 vs. 344 µm, P=0.004) and in mild-to-moderate than in pre-perimetric glaucoma eyes (448 vs. 390 µm, P=0.001). However, no significant difference was observed between mild-to-moderate and severe glaucoma eyes (448 vs. 437 µm, P=0.52). No correlation was observed between LC depth and VF MD (P=0.56) or RNFL thickness (P=0.90) in glaucomatous eyes with VF loss. Conclusions: In treated glaucoma, posterior LC displacement occurs mostly in the pre-perimetric and mild-to-moderate glaucoma stages. This warrants further investigation of LC depth as a parameter to monitor glaucoma progression in the early stages.
- 1 August 2014
- Published by Elsevier in Ophthalmology
- Vol. 121 (8) , 1531-1538
A New Index to Monitor Central Visual Field Progression in Glaucoma
- 1 August 2014
- Published by Elsevier in Ophthalmology
- Vol. 121 (8) , 1531-1538
A New Index to Monitor Central Visual Field Progression in Glaucoma
- Open Access
- 27 May 2014
- Published by Springer Nature in BMC Ophthalmology
- Vol. 14 (1) , 72
Analysis of neuroretinal rim distribution and vascular pattern in eyes with presumed large physiological cupping: a comparative study
To investigate possible differences in neuroretinal rim distribution, vascular pattern, and peripapillary region appearance between eyes with presumed large physiological optic disc cupping (pLPC) and eyes with minimal optic disc excavation.
- 27 May 2014
- Published by Springer Nature in BMC Ophthalmology
- Vol. 14 (1) , 72
Open AccessAnalysis of neuroretinal rim distribution and vascular pattern in eyes with presumed large physiological cupping: a comparative study
To investigate possible differences in neuroretinal rim distribution, vascular pattern, and peripapillary region appearance between eyes with presumed large physiological optic disc cupping (pLPC) and eyes with minimal optic disc excavation.
- 1 May 2014
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 157 (5) , 945-952.e1
Risk Factors for Optic Disc Hemorrhage in the Low-Pressure Glaucoma Treatment Study
- 1 May 2014
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 157 (5) , 945-952.e1
Risk Factors for Optic Disc Hemorrhage in the Low-Pressure Glaucoma Treatment Study
- 1 March 2014
- Published by Elsevier in Ophthalmology
- Vol. 121 (3) , 741-749
Defining 10-2 Visual Field Progression Criteria
- 1 March 2014
- Published by Elsevier in Ophthalmology
- Vol. 121 (3) , 741-749
Defining 10-2 Visual Field Progression Criteria
- Open Access
- 1 January 2014
- Vol. 3 (3) , 91-98
Eyes with Large Disc Cupping and Normal Intraocular Pressure: Using Optical Coherence Tomography to Discriminate Those With and Without Glaucoma
We evaluated the ability of spectral-domain optic coherence tomography (SD-OCT) to differentiate large physiological optic disc cupping (LPC) from glaucomatous cupping in eyes with intraocular pressure (IOP) within the normal range. We prospectively enrolled patients with glaucoma or presumed LPC. Participants had optic discs with confirmed or suspected glaucomatous damage (defined as a vertical cup-to-disc ratio≥0.6), and all eyes had known untreated IOP<21 mmHg. For glaucomatous eyes, a reproducible glaucomatous visual field (VF) defect was required. LPC eyes required normal VF and no evidence of progressive glaucomatous neuropathy (follow-up≥30 months). Peripapillary retinal nerve fiber layer (pRNFL) and macular ganglion cell complex (GCC) thicknesses were obtained using SD-OCT. For all studied parameters of pRNFL and GCC thicknesses, eyes with glaucoma (n=36) had significantly thinner values compared to eyes with LPC (n=71; P<0.05 for all comparisons). In addition, pRNFL parameters had sensitivity of 66.7% and specificity of 83.1%, and GCC parameters had sensitivity of 61.2% and specificity of 81.7%. The combination of the two analyses increased the sensitivity to 80.6%. In conclusion, while evaluating patients with large optic disc cupping and IOP in the statistically normal range, SD-OCT had only limited diagnostic ability to differentiate those with and without glaucoma. Although the diagnostic ability of the pRNFL and the GCC scans were similar, these parameters yielded an increase in sensitivity when combined, suggesting that both parameters could be considered simultaneously in these cases.
- 1 January 2014
- Vol. 3 (3) , 91-98
Open AccessEyes with Large Disc Cupping and Normal Intraocular Pressure: Using Optical Coherence Tomography to Discriminate Those With and Without Glaucoma
We evaluated the ability of spectral-domain optic coherence tomography (SD-OCT) to differentiate large physiological optic disc cupping (LPC) from glaucomatous cupping in eyes with intraocular pressure (IOP) within the normal range. We prospectively enrolled patients with glaucoma or presumed LPC. Participants had optic discs with confirmed or suspected glaucomatous damage (defined as a vertical cup-to-disc ratio≥0.6), and all eyes had known untreated IOP<21 mmHg. For glaucomatous eyes, a reproducible glaucomatous visual field (VF) defect was required. LPC eyes required normal VF and no evidence of progressive glaucomatous neuropathy (follow-up≥30 months). Peripapillary retinal nerve fiber layer (pRNFL) and macular ganglion cell complex (GCC) thicknesses were obtained using SD-OCT. For all studied parameters of pRNFL and GCC thicknesses, eyes with glaucoma (n=36) had significantly thinner values compared to eyes with LPC (n=71; P<0.05 for all comparisons). In addition, pRNFL parameters had sensitivity of 66.7% and specificity of 83.1%, and GCC parameters had sensitivity of 61.2% and specificity of 81.7%. The combination of the two analyses increased the sensitivity to 80.6%. In conclusion, while evaluating patients with large optic disc cupping and IOP in the statistically normal range, SD-OCT had only limited diagnostic ability to differentiate those with and without glaucoma. Although the diagnostic ability of the pRNFL and the GCC scans were similar, these parameters yielded an increase in sensitivity when combined, suggesting that both parameters could be considered simultaneously in these cases.