Laura G. Wesolowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Laura G. Wesolowski has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Pollyanna R. Chavez
Division of HIV Prevention, Centers for Disease Control and Prevention, Atlanta, GA, United States
4 shared publications - Kevin P. Delaney
Division of HIV Prevention, Centers for Disease Control and Prevention
3 shared publications - Steven Bs Ethridge
Division of HIV/AIDS Prevention, Centers for Disease Control and Prevention, Atlanta, GA
3 shared publications - Andy Cornelius-Hudson
Department of Medicine, University of Washington, Seattle, WA, United States
2 shared publications - David A. Katz
Department of Global Health, University of Washington, Seattle, WA
2 shared publications - Hollie A Clark
Division of HIV/AIDS Prevention, Centers for Disease Control and Prevention, Atlanta, GA, United States
2 shared publications
Latest Publications
- 1 November 2022
- Published by Springer Nature in AIDS and Behavior
- Vol. 27 (5) , 1716-1725
Distribution of HIV Self-tests by Men Who have Sex with Men (MSM) to Social Network Associates
Internet-recruited gay, bisexual, and other men who have sex with men (MSM) were offered HIV self-tests (HIVSTs) after completing baseline, 3-, 6-, and 9-m
- 1 November 2022
- Published by Springer Nature in AIDS and Behavior
- Vol. 27 (5) , 1716-1725
Distribution of HIV Self-tests by Men Who have Sex with Men (MSM) to Social Network Associates
Internet-recruited gay, bisexual, and other men who have sex with men (MSM) were offered HIV self-tests (HIVSTs) after completing baseline, 3-, 6-, and 9-m
- Open Access
- 1 May 2020
- Published by Wolters Kluwer Health in Sexually Transmitted Diseases
- Vol. 47 (5S) , S8-S12
Three Years of Shared Service HIV Nucleic Acid Testing for Public Health Laboratories: Worthwhile for HIV-1 but Not for HIV-2
Background In 2016, HIV-2 nucleic acid testing (NAT) was added to a shared service program that conducts HIV-1 NAT for public health laboratories performing the recommended algorithm for diagnosing HIV. Here, we evaluate the usefulness of HIV-2 NAT in this program as compared with HIV-1 NAT. Methods Specimens eligible for HIV-1 NAT were reactive on an HIV-1/2 antibody or antigen/antibody initial test and nonreactive or indeterminate on a supplemental antibody test or were reactive for HIV-1 antigen-only on an HIV-1/2 antigen/antibody initial test. Specimens eligible for HIV-2 NAT were reactive on an initial test, HIV-2 indeterminate or HIV indeterminate on a supplemental antibody test and had no detectable HIV-1 RNA or were reactive for HIV-2 antibody on an HIV-1/2 antigen/antibody test, and this reactivity was not confirmed with a supplemental antibody assay. All specimens were tested in a reference laboratory using APTIMA HIV-1 qualitative RNA and/or a validated qualitative HIV-2 RNA real-time PCR assay. Results During 2016 to 2019, HIV-1 RNA was detected in 234 (14%) of 1731 specimens tested. HIV-2 RNA was not detected in 52 specimens tested. Median time from specimen collection to reporting of HIV-1 and HIV-2 NAT results by year ranged from 9 to 10 days and from 22 to 27 days, respectively. Two specimens with HIV-2 indeterminate results on a supplemental antibody test had detectable HIV-1 RNA. Conclusions A shared service model for HIV-1 NAT is both feasible and beneficial for public health laboratories. However, because no HIV-2 infections were detected, our data suggest that this program should reconsider the usefulness of HIV-2 NAT testing.
- 1 May 2020
- Published by Wolters Kluwer Health in Sexually Transmitted Diseases
- Vol. 47 (5S) , S8-S12
Open AccessThree Years of Shared Service HIV Nucleic Acid Testing for Public Health Laboratories: Worthwhile for HIV-1 but Not for HIV-2
Background In 2016, HIV-2 nucleic acid testing (NAT) was added to a shared service program that conducts HIV-1 NAT for public health laboratories performing the recommended algorithm for diagnosing HIV. Here, we evaluate the usefulness of HIV-2 NAT in this program as compared with HIV-1 NAT. Methods Specimens eligible for HIV-1 NAT were reactive on an HIV-1/2 antibody or antigen/antibody initial test and nonreactive or indeterminate on a supplemental antibody test or were reactive for HIV-1 antigen-only on an HIV-1/2 antigen/antibody initial test. Specimens eligible for HIV-2 NAT were reactive on an initial test, HIV-2 indeterminate or HIV indeterminate on a supplemental antibody test and had no detectable HIV-1 RNA or were reactive for HIV-2 antibody on an HIV-1/2 antigen/antibody test, and this reactivity was not confirmed with a supplemental antibody assay. All specimens were tested in a reference laboratory using APTIMA HIV-1 qualitative RNA and/or a validated qualitative HIV-2 RNA real-time PCR assay. Results During 2016 to 2019, HIV-1 RNA was detected in 234 (14%) of 1731 specimens tested. HIV-2 RNA was not detected in 52 specimens tested. Median time from specimen collection to reporting of HIV-1 and HIV-2 NAT results by year ranged from 9 to 10 days and from 22 to 27 days, respectively. Two specimens with HIV-2 indeterminate results on a supplemental antibody test had detectable HIV-1 RNA. Conclusions A shared service model for HIV-1 NAT is both feasible and beneficial for public health laboratories. However, because no HIV-2 infections were detected, our data suggest that this program should reconsider the usefulness of HIV-2 NAT testing.
- Open Access
- 27 January 2020
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 9 (1) , e16332
Prospective Evaluation of HIV Testing Technologies in a Clinical Setting: Protocol for Project DETECT
Background: HIV testing guidelines provided by the Centers for Disease Control and Prevention (CDC) are continually changing to reflect advancements in new testing technology. Evaluation of existing and new point-of-care (POC) HIV tests is crucial to inform testing guidelines and provide information to clinicians and other HIV test providers. Characterizing the performance of POC HIV tests using unprocessed specimens can provide estimates for the window period of detection, or the time from HIV acquisition to test positivity, which allows clinicians and other HIV providers to select the appropriate POC HIV tests for persons who may be recently infected with HIV. Objective: This paper describes the protocols and procedures used to evaluate the performance of the newest POC tests and determine their sensitivity during early HIV infection. Methods: Project DETECT is a CDC-funded study that is evaluating POC HIV test performance. Part 1 is a cross-sectional, retrospective study comparing behavioral characteristics and HIV prevalence of the overall population of the Public Health–Seattle & King County (PHSKC) Sexually Transmitted Disease (STD) Clinic to Project DETECT participants enrolled in part 2. Part 2 is a cross-sectional, prospective study evaluating POC HIV tests in real time using unprocessed whole blood and oral fluid specimens. A POC nucleic acid test (NAT) was added to the panel of HIV tests in June 2018. Part 3 is a longitudinal, prospective study evaluating seroconversion sensitivity of POC HIV tests through serial follow-up testing. For comparison, HIV-1 RNA and HIV-1/HIV-2 antigen/antibody tests are also performed for participants enrolled in part 2 or 3. A behavioral survey that collects information about demographics, history of HIV testing, STD history, symptoms of acute HIV infection, substance use, sexual behaviors in the aggregate and with recent partners, and use of pre-exposure prophylaxis and antiretroviral therapy is completed at each part 2 or 3 visit. Results: Between September 2015 and March 2019, there were 14,990 Project DETECT–eligible visits (part 1) to the PHSKC STD Clinic resulting in 1819 part 2 Project DETECT study visits. The longitudinal study within Project DETECT (part 3) enrolled 27 participants with discordant POC test results from their part 2 visit, and 10 (37%) were followed until they had fully seroconverted with concordant positive POC test results. Behavioral survey data and HIV test results, sensitivity, and specificity will be presented elsewhere. Conclusions: Studies such as Project DETECT are critical for evaluating POC HIV test devices as well as describing characteristics of persons at risk for HIV acquisition in the United States. HIV tests in development, including POC NATs, will provide new opportunities for HIV testing programs. International Registered Report Identifier (IRRID): RR1-10.2196/16332
- 27 January 2020
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 9 (1) , e16332
Open AccessProspective Evaluation of HIV Testing Technologies in a Clinical Setting: Protocol for Project DETECT
Background: HIV testing guidelines provided by the Centers for Disease Control and Prevention (CDC) are continually changing to reflect advancements in new testing technology. Evaluation of existing and new point-of-care (POC) HIV tests is crucial to inform testing guidelines and provide information to clinicians and other HIV test providers. Characterizing the performance of POC HIV tests using unprocessed specimens can provide estimates for the window period of detection, or the time from HIV acquisition to test positivity, which allows clinicians and other HIV providers to select the appropriate POC HIV tests for persons who may be recently infected with HIV. Objective: This paper describes the protocols and procedures used to evaluate the performance of the newest POC tests and determine their sensitivity during early HIV infection. Methods: Project DETECT is a CDC-funded study that is evaluating POC HIV test performance. Part 1 is a cross-sectional, retrospective study comparing behavioral characteristics and HIV prevalence of the overall population of the Public Health–Seattle & King County (PHSKC) Sexually Transmitted Disease (STD) Clinic to Project DETECT participants enrolled in part 2. Part 2 is a cross-sectional, prospective study evaluating POC HIV tests in real time using unprocessed whole blood and oral fluid specimens. A POC nucleic acid test (NAT) was added to the panel of HIV tests in June 2018. Part 3 is a longitudinal, prospective study evaluating seroconversion sensitivity of POC HIV tests through serial follow-up testing. For comparison, HIV-1 RNA and HIV-1/HIV-2 antigen/antibody tests are also performed for participants enrolled in part 2 or 3. A behavioral survey that collects information about demographics, history of HIV testing, STD history, symptoms of acute HIV infection, substance use, sexual behaviors in the aggregate and with recent partners, and use of pre-exposure prophylaxis and antiretroviral therapy is completed at each part 2 or 3 visit. Results: Between September 2015 and March 2019, there were 14,990 Project DETECT–eligible visits (part 1) to the PHSKC STD Clinic resulting in 1819 part 2 Project DETECT study visits. The longitudinal study within Project DETECT (part 3) enrolled 27 participants with discordant POC test results from their part 2 visit, and 10 (37%) were followed until they had fully seroconverted with concordant positive POC test results. Behavioral survey data and HIV test results, sensitivity, and specificity will be presented elsewhere. Conclusions: Studies such as Project DETECT are critical for evaluating POC HIV test devices as well as describing characteristics of persons at risk for HIV acquisition in the United States. HIV tests in development, including POC NATs, will provide new opportunities for HIV testing programs. International Registered Report Identifier (IRRID): RR1-10.2196/16332
- Open Access
- 19 September 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Prospective Evaluation of HIV Testing Technologies in a Clinical Setting: Protocol for Project DETECT (Preprint)
BACKGROUND HIV testing guidelines provided by the Centers for Disease Control and Prevention (CDC) are continually changing to reflect advancements in new testing technology. Evaluation of existing and new point-of-care (POC) HIV tests is crucial to inform testing guidelines and provide information to clinicians and other HIV test providers. Characterizing the performance of POC HIV tests using unprocessed specimens can provide estimates for the window period of detection, or the time from HIV acquisition to test positivity, which allows clinicians and other HIV providers to select the appropriate POC HIV tests for persons who may be recently infected with HIV. OBJECTIVE This paper describes the protocols and procedures used to evaluate the performance of the newest POC tests and determine their sensitivity during early HIV infection. METHODS Project DETECT is a CDC-funded study that is evaluating POC HIV test performance. Part 1 is a cross-sectional, retrospective study comparing behavioral characteristics and HIV prevalence of the overall population of the Public Health–Seattle & King County (PHSKC) Sexually Transmitted Disease (STD) Clinic to Project DETECT participants enrolled in part 2. Part 2 is a cross-sectional, prospective study evaluating POC HIV tests in real time using unprocessed whole blood and oral fluid specimens. A POC nucleic acid test (NAT) was added to the panel of HIV tests in June 2018. Part 3 is a longitudinal, prospective study evaluating seroconversion sensitivity of POC HIV tests through serial follow-up testing. For comparison, HIV-1 RNA and HIV-1/HIV-2 antigen/antibody tests are also performed for participants enrolled in part 2 or 3. A behavioral survey that collects information about demographics, history of HIV testing, STD history, symptoms of acute HIV infection, substance use, sexual behaviors in the aggregate and with recent partners, and use of pre-exposure prophylaxis and antiretroviral therapy is completed at each part 2 or 3 visit. RESULTS Between September 2015 and March 2019, there were 14,990 Project DETECT–eligible visits (part 1) to the PHSKC STD Clinic resulting in 1819 part 2 Project DETECT study visits. The longitudinal study within Project DETECT (part 3) enrolled 27 participants with discordant POC test results from their part 2 visit, and 10 (37%) were followed until they had fully seroconverted with concordant positive POC test results. Behavioral survey data and HIV test results, sensitivity, and specificity will be presented elsewhere. CONCLUSIONS Studies such as Project DETECT are critical for evaluating POC HIV test devices as well as describing characteristics of persons at risk for HIV acquisition in the United States. HIV tests in development, including POC NATs, will provide new opportunities for HIV testing programs. INTERNATIONAL REGISTERED REPORT RR1-10.2196/16332
- 19 September 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessProspective Evaluation of HIV Testing Technologies in a Clinical Setting: Protocol for Project DETECT (Preprint)
BACKGROUND HIV testing guidelines provided by the Centers for Disease Control and Prevention (CDC) are continually changing to reflect advancements in new testing technology. Evaluation of existing and new point-of-care (POC) HIV tests is crucial to inform testing guidelines and provide information to clinicians and other HIV test providers. Characterizing the performance of POC HIV tests using unprocessed specimens can provide estimates for the window period of detection, or the time from HIV acquisition to test positivity, which allows clinicians and other HIV providers to select the appropriate POC HIV tests for persons who may be recently infected with HIV. OBJECTIVE This paper describes the protocols and procedures used to evaluate the performance of the newest POC tests and determine their sensitivity during early HIV infection. METHODS Project DETECT is a CDC-funded study that is evaluating POC HIV test performance. Part 1 is a cross-sectional, retrospective study comparing behavioral characteristics and HIV prevalence of the overall population of the Public Health–Seattle & King County (PHSKC) Sexually Transmitted Disease (STD) Clinic to Project DETECT participants enrolled in part 2. Part 2 is a cross-sectional, prospective study evaluating POC HIV tests in real time using unprocessed whole blood and oral fluid specimens. A POC nucleic acid test (NAT) was added to the panel of HIV tests in June 2018. Part 3 is a longitudinal, prospective study evaluating seroconversion sensitivity of POC HIV tests through serial follow-up testing. For comparison, HIV-1 RNA and HIV-1/HIV-2 antigen/antibody tests are also performed for participants enrolled in part 2 or 3. A behavioral survey that collects information about demographics, history of HIV testing, STD history, symptoms of acute HIV infection, substance use, sexual behaviors in the aggregate and with recent partners, and use of pre-exposure prophylaxis and antiretroviral therapy is completed at each part 2 or 3 visit. RESULTS Between September 2015 and March 2019, there were 14,990 Project DETECT–eligible visits (part 1) to the PHSKC STD Clinic resulting in 1819 part 2 Project DETECT study visits. The longitudinal study within Project DETECT (part 3) enrolled 27 participants with discordant POC test results from their part 2 visit, and 10 (37%) were followed until they had fully seroconverted with concordant positive POC test results. Behavioral survey data and HIV test results, sensitivity, and specificity will be presented elsewhere. CONCLUSIONS Studies such as Project DETECT are critical for evaluating POC HIV test devices as well as describing characteristics of persons at risk for HIV acquisition in the United States. HIV tests in development, including POC NATs, will provide new opportunities for HIV testing programs. INTERNATIONAL REGISTERED REPORT RR1-10.2196/16332