LOLuis. F. Olguin

Luis. F. Olguin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luis. F. Olguin has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Critical aspects of droplet digital reverse transcription loop-mediated isothermal amplification (ddRT-LAMP) for viral pathogens detection

    by Kenia Chávez-Ramos, Frida Trejo, Prisciluis Caheri Salas-Navarrete, Eva Ramón-Gallegos, José Esteban Muñoz-Medina, Luis Alvarez-Icaza, Luis F. Olguin, Oscar Pilloni, Laura Oropeza-Ramos

    The COVID-19 pandemic evidenced the urgent need for rapid, accurate, and scalable diagnostic methods for emerging infectious diseases. Droplet digital reverse transcription LAMP (ddRT-LAMP) is a promising technique for pathogen detection and accurate quantification, as it overcomes traditional LAMP’s limitations in viral load estimation through reaction partitioning and digital analysis. However, many parameters must be adjusted to avoid spurious results. This study evaluates the critical conditions for effective ddRT-LAMP quantification of the SARS-CoV-2 N gene in plasmid DNA, synthetic RNA, and nasopharyngeal swab samples. Using a polydimethylsiloxane (PDMS) microfluidic device, the RT-LAMP reaction mixture with a fluorescent dye was divided into thousands of droplets stabilized by a surfactant in fluorinated oil. After incubation, the droplets were injected into a PDMS chamber for fluorescent imaging to determine the proportion of positive droplets and quantify the samples based on the Poisson distribution. The results showed that primer design and master mix composition significantly impacted the amplification. The selection of GelGreen® as the fluorescent dye was crucial, as other dyes tested diffused into the oil phase. Optimal amplification occurred with 105 µm droplet diameter and 30-min incubation, achieving detection and quantification limits of 102 cp/µL. By addressing these operational challenges, ddRT-LAMP can become a more effective tool for viral detection and quantification in clinical diagnostics.


  • Open Access

    Evaluation of dynamical-billiard-shaped chambers as divergent elements of passive micromixers

    by Abraham Ochoa-Guerrero, Luis F. Olguín, Eugenia Corvera-Poiré

    Efficient mixing of fluid streams in microfluidic devices remains a critical challenge due to the dominance of laminar flow, where mixing relies solely on diffusion. To overcome this limitation, various microfluidic mixers have been developed to transition from laminar to non-laminar regimes, enabling faster mixing rates. Passive micromixers utilize geometric channel designs instead of external energy sources, making them advantageous due to their simplicity. Among these, convergent-divergent micromixers employ alternating narrow and wide channels to stretch and fold fluid streams, enhancing the mixing process. This study explores a novel series of microfluidic mixers based on dynamical-billiard-shaped chambers. Each microfluidic mixer comprises twenty consecutive nanoliter billiard-shaped chambers connected by relatively narrow channels of equal or variable lengths. Six chamber designs were analyzed: three chaotic billiard shapes (Bunimovich-stadium, diamond-shape, and Sinai-billiard) and their respective non-chaotic counterparts (ellipse, triangle, and ring). Two spatial arrangements—out-of-axis and on-axis chambers—were tested to evaluate their impact on mixing efficiency. Key findings reveal that an out-of-axis chamber configuration significantly enhances mixing, as does connectors with varying lengths. Orientation of the initial chamber at a 36° angle further improves performance. However, chaotic chambers did not consistently outperform non-chaotic ones, likely due to limitations in flow rates. Comparisons with a previously reported baffled structure, considered an excellent micromixer, showed improved mixing efficiency using both chaotic and non-chaotic chambers. These results provide valuable insights into passive mixing mechanisms, contributing to the design of more efficient microfluidic mixers adaptable to specific experimental conditions.


  • High-throughput bacterial co-encapsulation in microfluidic gel beads for discovery of antibiotic-producing strains

    by Abraham Ochoa, Gabriela Gastélum, Jorge Rocha, Luis F. Olguin

    Bacteria with antagonistic activity inhibit the growth of other bacteria through different mechanisms, including the production of antibiotics. As a result, these microorganisms are a prolific source of such compounds. However, searching for antibiotic-producing strains requires high-throughput techniques due to the vast diversity of microorganisms. Here, we screened and isolated bacteria with antagonistic activity against Escherichia coli expressing the green fluorescent protein (E. coli-GFP). We used microfluidics to co-encapsulate and co-culture single cells from different strains within picoliter gel beads and analyzed them using fluorescence-activated cell sorting (FACS). To test the methodology, we used three bacterial isolates obtained from Mexican maize, which exhibit high, moderate, or no antagonistic activity against E. coli-GFP, as determined previously using agar plate assays. Single cells from each strain were separately co-incubated into gel beads with E. coli-GFP. We monitored the development of the maize bacteria microcolonies and tracked the growth or inhibition of E. coli-GFP using bright-field and fluorescent microscopy. We correlated these images with distinctive light scatter and fluorescence signatures of each incubated bead type using FACS. This analysis enabled us to sort gel beads filled with an antagonistic strain, starting from a mixture of the three different types of maize bacteria and E. coli-GFP. Likewise, culturing the FACS-sorted beads on agar plates confirmed the isolation and recovery of the two antagonistic strains. In addition, enrichment assays demonstrated the methodology's effectiveness in isolating rare antibiotic-producer strains (0.01% abundance) present in a mixture of microorganisms. These results show that associating light side scatter and fluorescent flow cytometry signals with microscopy images provides valuable controls to establish successful high-throughput methods for sorting beads in which microbial interaction assays are performed.


  • Open Access

    Prebiotic Chemistry Experiments Using Microfluidic Devices

    by Karen Melissa Lerin-Morales, Luis F. Olguín, Eva Mateo-Martí, María Colín-García

    Microfluidic devices are small tools mostly consisting of one or more channels, with dimensions between one and hundreds of microns, where small volumes of fluids are manipulated. They have extensive use in the biomedical and chemical fields; however, in prebiotic chemistry, they only have been employed recently. In prebiotic chemistry, just three types of microfluidic devices have been used: the first ones are Y-form devices with laminar co-flow, used to study the precipitation of minerals in hydrothermal vents systems; the second ones are microdroplet devices that can form small droplets capable of mimic cellular compartmentalization; and the last ones are devices with microchambers that recreate the microenvironment inside rock pores under hydrothermal conditions. In this review, we summarized the experiments in the field of prebiotic chemistry that employed microfluidic devices. The main idea is to incentivize their use and discuss their potential to perform novel experiments that could contribute to unraveling some prebiotic chemistry questions.


  • An optical sensor combining surface plasmon resonance, light extinction, and near-critical angle reflection, for thin liquid film biochemical sensing

    by V. Solis-Tinoco, Gesuri Morales-Luna, A. Acevedo-Barrera, Abraham Ochoa, Omar Vazquez-Estrada, Luis. F. Olguin, A. García-Valenzuela


  • Open Access

    Experimental Resonances in Viscoelastic Microfluidics

    by Pamela Vazquez-Vergara, Ulises Torres-Herrera, Gabriel A. Caballero-Robledo, Luis F. Olguin, Eugenia Corvera Poiré

    Pulsatile flows of viscoelastic fluids are very important for lab-on-a-chip devices, because most biofluids have viscoelastic character and respond distinctively to different periodic forcing. They are also very important for organ-on-a-chip devices, where the natural mechanical conditions of cells are emulated. The resonance frequency of a fluid refers to a particular pulsatile periodicity of the pressure gradient that maximizes the amplitude of flow velocity. For viscoelastic fluids, this one has been measured experimentally only at macroscales, since fine tuning of rheological properties and system size is needed to observe it at microscales. We study the dynamics of a pulsatile (zero-mean flow) fluid slug formed by a viscoelastic fluid bounded by two air-fluid interfaces, in a microchannel of polymethyl methacrylate. We drive the fluid slug by a single-mode periodic pressure drop, imposed by a piezoactuator. We use three biocompatible polymer solutions of polyethylene oxide as model viscoelastic fluids, and find resonances. We propose a model accounting for surface tension and fluid viscoelasticity that has an excellent agreement with our experimental findings. It also provides an alternative way of measuring relaxation times. We validate the method with parameters reported in the literature for two of the solutions, and estimate the relaxation time for the third one.


  • Singular behavior of microfluidic pulsatile flow due to dynamic curving of air-fluid interfaces

    by Pamela Vazquez-Vergara, Ulises Torres-Herrera, Luis F. Olguin, Eugenia Corvera Poiré

    Pulsatile pressure gradients are widely present in microfluidic multiphase systems where the movement of fluids is affected by the presence of fluid-fluid interfaces. We present a simple theoretical model that incorporates dynamic interfacial curvatures produced as a response to pulsatile external forcing. Our equations make evident a singular character of the dynamics at low frequencies, due to surface tension. Analytical solution of the model shows the emergence of a resonant behavior for the dynamic permeability. We have designed and implemented microfluidic experiments to observe both the low-frequency dynamics and the resonance. We have studied a fluid slug whose length was chosen in order to look for resonances as predicted by our theoretical model, in the range of operational frequencies of our piezoelectric actuator. We have obtained the experimental dynamic permeability for water and a 70.0% glycerol solution in water and observed agreement with theoretical findings. Our model, validated by experiments, allows us to understand differences of several orders of magnitude in the amplitude of flow velocity at low frequencies, between systems with and without interfaces.


  • Droplet-Based Microfluidics Methods for Detecting Enzyme Inhibitors

    by Abraham Ochoa, Frida Trejo, Luis F. Olguín

    Sub-nanoliter droplets produced in microfluidic devices have gained an enormous importance for performing all kinds of biochemical assays. One of the main reasons is that the amounts of reagents employed can be reduced in approximately five orders of magnitude compared to conventional microplate assays. In this chapter, we describe how to carry out the design, fabrication, and operation of a microfluidic device that allows performing enzyme kinetics and enzyme inhibition assays in droplets. This procedure can be used effectively to screen a small size library of compounds. Then, we describe how to use this droplet microfluidic setup to screen for potential inhibitor compounds eluted from a coupled high-performance liquid chromatography (HPLC) system that separates crude natural extracts.