WCWalter Coudyzer

Walter Coudyzer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Walter Coudyzer has a total of 252 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pelvic trabecular bone detection and densitometry with ultra-high resolution and spectral photon-counting CT as compared to energy integrating detector CT and micro-CT: a cadaveric study

    by Stijn De Bondt, Thomas Anijs, Walter Coudyzer, Nathalie Noppe, Hilde Bosmans, Elena Paravisi, Harry van Lenthe, Michiel Herteleer

    Purpose: Evaluation of ultra-high resolution (UHR) and spectral photon-counting CT (PCCT) for pelvic trabecular bone (ptBone) detection and volumetric bone mineral density (vBMD) measurement using micro-CT (µCT) as reference standard and energy-integrating detector CT (EID-CT) as clinical benchmark.Methods: Four human cadavers underwent in-situ pelvic PCCT and EID-CT imaging. Thirteen specimens consisting of the sacral and fifth lumbar vertebrae were subsequently extracted and scanned with µCT. Spectral PCCT was evaluated using X-ray attenuation decomposition (XAD), calculated from virtual monoenergetic images (VMIs). ptBone detection was assessed using classification metrics consisting of sensitivity, specificity, and Dice, and contrast-to-noise ratio (CNR). vBMD was quantified on ex-vivo sacral PCCT scans with and without calibration phantom using respectively poly-energetic images and XAD. Secondary analyses evaluated the effect of radiation dose and PCCT reconstruction parameters.Results: UHR PCCT achieved the highest trabecular detection accuracy, although overall agreement with µCT remained modest (Dice coefficient of 0.35±0.03 vs 0.23-0.27±0.02 for spectral PCCT and 0.24±0.02 for EID-CT, p<0.05). Increasing radiation dose improved CNR but reduced classification metrics. Softer reconstruction kernels and larger matrix sizes yielded the best performance. High resolution PCCT (HR) showed a stronger Pearson’s correlation with vBMD derived from µCT (Pearson’s r=0.87) than UHR PCCT, spectral PCCT and EID-CT (Pearson’s r=0.46-0.62).Conclusion: UHR PCCT improved ptBone detection compared to spectral PCCT and EID-CT, although agreement with µCT remained low to moderate. HR PCCT-based vBMD correlated highly to µCT-based vBMD, supporting its potential for opportunistic osteoporosis assessment on routine pelvic PCCT imaging.

  • Open Access

    Ultra-high resolution photon-counting CT of the lung after lung transplantation: should we go for optimal image quality or reduced radiation dose?

    by Adriana Dubbeldam, Valerie Van Ballaer, Johny Verschakelen, Emanuele Muscogiuri, Joke Binst, Lesley Cockmartin, Hilde Bosmans, Walter Coudyzer, Kwinten Torfs, Emanuele Di Dedda, et al.

  • Open Access

    Photon‐Counting CT for Diagnosing Vertical Root Fractures in Teeth With Metal Posts: An Ex Vivo Comparative Analysis With Four CBCT Devices

    by Renata M. S. Leal, Fernanda B. Fagundes, Maria F. S. A. Bortoletto, Samuel C. Kluthcovsky, Walter Coudyzer, Bruno C. Cavenago, Reinhilde Jacobs, Rocharles Cavalcante Fontenele

    Objective: Photon‐counting computed tomography (PCCT) represents a major innovation in X‐ray detection technology, offering improved signal efficiency and reduced electronic noise compared with cone‐beam computed tomography (CBCT), which can enhance image quality. This study aimed to evaluate the diagnostic performance of PCCT in detecting vertical root fractures (VRF), in comparison with four CBCT devices. Methodology: Eighteen single‐rooted teeth were endodontically treated, and VRF was induced in eight of them. Each tooth was individually placed into the mandibular first premolar empty socket of an anthropomorphic phantom and scanned under three conditions: without a metal post, with a nickel‐chromium metal post (Ni‐Cr), and with a cobalt‐chromium metal post (Co‐Cr) in five CT devices: the NAEOTOM Alpha PCCT (Siemens Healthineers) device and four CBCT devices (3D Accuitomo 170—Morita, Veraview X800—Morita, NewTom VGi evo—NewTom, and Carestream 9600—Carestream). The highest‐resolution protocol available on each device was used, resulting in a total of 270 scans. Five experienced dentomaxillofacial radiologists independently and blindly evaluated the scans using a five‐point confidence scale. Diagnostic accuracy was assessed by calculating the area under the ROC curve (AUC), sensitivity, and specificity, with results compared by two‐way ANOVA with post hoc Tukey's test ( α = 0.05). Results: NewTom VGi and PCCT devices showed significantly higher AUC values than the Veraview X800, regardless of the metal post material ( p < 0.05). CS9600 and PCCT devices exhibited significantly higher sensitivity values in diagnosing with Ni‐Cr posts than the Accuitomo 3D and Veraview X800 devices ( p < 0.05). With the Co‐Cr metal post, the NewTom VGi, CS9600, and PCCT devices showed significantly higher sensitivity values compared to the Veraview X800 device ( p < 0.05). There were no statistically significant differences in specificity, regardless of the CT device or metal post material ( p > 0.05). Conclusions: The NEAOTOM Alpha PCCT showed high diagnostic accuracy for VRF detection in an ex vivo model, comparable to high‐resolution CBCT devices, highlighting its diagnostic performance under controlled ex vivo conditions.


  • Open Access

    Passive versus active right ventricular support during lung transplantation: Insights from a porcine pulmonary ischemia-reperfusion injury model

    by Michaela Orlitová, Piet Claus, Dieter van Beersel, Anna E. Kaiser-Frick, Arno Vanstapel, Walter Coudyzer, Kristof Van de Voorde, Karlien Degezelle, Robin Vos, Dirk E. Van Raemdonck, et al.

  • Fifteen Year Outcome Results of Endovascular Aortic Repair with a Third Generation Endograft

    by Jessie Reymen, Hozan Mufty, Annouschka Laenen, Sabrina Houthoofd, Walter Coudyzer, Inge Fourneau, Geert Maleux


  • Open Access

    Distinct Morphological Types of Small Airway Obstructions in Smokers with Emphysema and End-Stage Chronic Obstructive Pulmonary Disease

    by Vincent Geudens, Charlotte De Fays, Lynn Willems, Astrid Vermaut, Gitte Aerts, Pieterjan Kerckhof, Janne Kaes, Charlotte Hooft, Xin Jin, Hanne Beeckmans, et al.

    Rationale: The precise nature of small airway obstructions in chronic obstructive pulmonary disease (COPD) remains poorly understood, especially at early disease stages. Objectives: This study aimed to characterize small airway obstructions and numbers up to the terminal bronchioles (TBs) in smokers with limited emphysema and end-stage COPD. We hypothesized that obstruction subtypes would differ in morphology, nature, and number from early to end-stage COPD. Methods: Whole lungs were inflated and processed from seven control donors (control: declined for extrapulmonary reasons); from eight donors with a history of smoking, of whom three had 5% emphysema (smokers with emphysema); and from eight patients with end-stage COPD. Micro–computed tomography of tissue was used to assess number of TBs, aerated TBs, and number and type of obstructions and was cross-correlated with histopathology. Measurements and Main Results: Obstructions were mainly present in smokers with emphysema and patients with COPD, resulting in less aerated TBs. On the basis of emphysema extent, more nonaerated TBs were present in regions with no emphysema than in regions with mild emphysema; however, destruction was more prominent in mild emphysema. Multiple types of obstructions were identified, comprising occlusions, webs, and collapses. In smokers with emphysema, obstructions primarily comprised webs and occlusions, whereas all obstruction types were present in COPD. On histopathology, obstructions were identified as mucus plugs. Conclusions: Multiple types of obstruction characterized as mucus plugs were identified in smokers with emphysema and patients with end-stage COPD. Their morphology, nature, and number evolved from smokers with emphysema to end-stage COPD. A shift from obstruction-dominant dysfunction to destruction-dominant pathology was found in smokers on the basis of emphysema presence.


  • Open Access

    Preclinical research on the effect of thoraco-abdominal normothermic regional perfusion on pulmonary function: A comparison of 2 strategies

    by Katrien Vandendriessche, Michaela Orlitová, Arno Vanstapel, Walter Coudyzer, Dieter Van Beersel, Laurens J. Ceulemans, Bart Meyns, Filip Rega, Arne P. Neyrinck


  • Open Access

    Computational fluid dynamics of small airway disease in chronic obstructive pulmonary disease

    by Yousry K. Mohamady, Vincent Geudens, Charlotte De Fays, Marta Zapata, Omar Hagrass, Lucia Aversa, Marie Vermant, Xin Jin, Lynn Willems, Iwein Gyselinck, et al.


  • Open Access

    Evaluating AI-Driven Mobile Applications and Open-Source Software for Assessing Facial Growth and Development: A Retrospective Observational Study (Preprint)

    by Maria Ignacia Bustamante Araya, Gonzalo Muradas Odriozola, Walter Coudyzer, Reinhilde Jacobs

    BACKGROUND Facial growth and development are dynamic processes influenced by intrinsic and extrinsic factors. Predicting these changes is essential in forensic science and clinical dentistry. While AI-driven age progression tools like Remini AI (a mobile application) and SAM (open-source software) may offer innovative solutions, their clinical applicability remains underexplored. OBJECTIVE To evaluate the accuracy and clinical feasibility of AI-driven age progression tools: using a mobile application (Remini AI) and an open-source software (SAM). METHODS This retrospective observational study used the FG-NET aging database and additional personal images. Remini AI and SAM processed 18 images each, generating 180 age-progressed images in total for predefined age groups (5, 11, 15, 18, and 26 years). Subjective assessments involved dental experts performing reordering, categorization, and accuracy tasks, while objective assessments used an age estimation model (MiVolo) to estimate the age of the AI-generated images. Statistical analyses included t-tests and chi-square tests with a significance level of 5%. RESULTS Remini AI achieved higher results for the categorization task (55%, P < .001), whereas SAM demonstrated superior accuracy in generating realistic age progressions between 11 and 18 years old, with a lower mean absolute error (2.7 years vs. 3.7 years, P < .001). Neither tool performed effectively for younger (age 5) or older (age 26) age groups. SAM outperformed Remini AI in processing speed, generating images in an average of 9 seconds versus 5 minutes per image (P < .001). CONCLUSIONS Remini AI excels in categorization tasks, while SAM demonstrates greater accuracy and efficiency for realistic age progressions, particularly in mid-childhood and young adulthood. Both tools require refinement for younger and older populations. These findings emphasize the potential of AI-driven tools in forensic investigations and clinical dentistry, including orthodontic planning and reconstructive procedures. CLINICALTRIAL This study is retrospective and observational, and no trial registration is applicable.

  • Open Access

    Personalized Contrast Agent Volumes in Abdominal CT: Bridging Theory with Practice

    by Walter Coudyzer, Lesley Cockmartin, Bram Miseur, Tim Busselot, Didier Bielen, Dirk Vanbeckevoort, Raymond Oyen, Hilde Bosmans

    Objectives: to determine (1) a target Hounsfield unit (HU) for portal venous phase iodinated contrast media enhanced abdominal CT scans, (2) an equation for a personalized total contrast agent volume, and (3) the best/most appropriate time between injection and plateau/peak in HU enhancement. Material and methods: from an original dataset of 5,000 cases, a weight representative subset of 370 cases was sampled for detailed HU measurements. An additional 90 cases were used for visual grading to define the minimal HU required for diagnostic quality, which led to the proposed target HU. This study uses the fact that in a first approach, the injected contrast agent volume and HU correlate linearly. Based on the injected contrast agent volumes and HU measurements in the patient scans, it was then calculated which (ideal) volume would have reached the target value. The ideal volumes and patient data (weight, height, heart rate, age, and gender) were correlated by means of a regression analysis, to determine a new patient-specific contrast volume calculation equation. The best scan delay time was derived from the start of the injection to the HU enhancement plateau/peak evaluated from manually triggered venous phase scans. Results: The target HU value was 125. This can be achieved with a personalized contrast agent volume (ml), equal to − 108.5 + ∗ weight(kg) + 0.40 ∗ heart rate(bpm) + 0.61 ∗ height(cm). The time delay between injection and HU plateau/peak was found to be, on average, 102 s. Conclusion: this study proposes a comprehensive protocol for contrast enhanced venous phase scans, including a target HU, a personalized contrast volume, and a scan delay.