HSHosein Sadafi

Hosein Sadafi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hosein Sadafi has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing aerosol delivery in asthma and COPD: a comparison of MDI, valved holding chamber, and DPI systems using functional respiratory imaging (FRI)

    by Mark W. Nagel, Hosein Sadafi, Jason A. Suggett

    Effective respiratory therapy relies heavily on inhaler device efficiency and patient technique. While device performance is well-documented in idealized induction ports, there remains a critical lack of data integrating patient-specific disease states to compare pressurized metered-dose inhaler (MDI) and valved holding chamber (VHC) efficiency against legacy dry powder inhaler (DPI) formulations. This study addresses this gap using Functional Respiratory Imaging (FRI) which combines high-resolution computed tomography (CT) scans with Computational Fluid Dynamics (CFD) to quantitatively assess aerosol deposition in asthma and Chronic Obstructive Pulmonary Disease (COPD) patient models. We evaluated the performance of MDIs alone and with various VHCs, against DPIs under optimal and sub-optimal inhalation profiles. Our results indicate that while MDIs alone require precise coordination, the addition of a VHC (AeroChamber Plus Flow-Vu) maintains high intrathoracic deposition and significantly minimizes oropharyngeal deposition, even with inhalation delays. Furthermore, the MDI/VHC combination demonstrated superior lung delivery compared to other tested VHCs and DPIs. Notably, the MDI/VHC system exhibited greater consistency across varying flow rates, whereas the DPIs tested showed higher sensitivity to sub-optimal maneuvers. Using FRI as tool for comparative inhaler assessment these results suggest that MDIs with appropriate VHCs provide the most consistent medication delivery for obstructive airway diseases.


  • Leveraging Model Master Files from a Technology Company Perspective: Facilitating Quantitative Medicine in Regulatory Frameworks

    by Jan De Backer, James Clarke, Hosein Sadafi, William Ganley, Jessica Spires

    Model Master Files (MMFs) offer a much needed approach to integrating computational modelling into drug development and regulatory frameworks, supporting the growth of quantitative medicine. By acting as confidential repositories for validated models, MMFs enable streamlined submissions, model reuse, and context-specific reviews while safeguarding intellectual property. For technology companies (such as software providers), MMFs provide a structured pathway to engage with the FDA, align innovations with regulatory standards, and expand the use of models across diverse applications. A challenge with the current framework is the need to provide the same validation and verification information to multiple drug companies each time the submit an application. With an MMF in place, drug companies can refer to this same document which the technology provider can add to over time. However, challenges persist, including limited direct interaction with the FDA outside (A)NDA submissions and the need for consistent model validation and version management. Addressing these issues through enhanced collaboration and clear guidelines will maximize the potential of MMFs, fostering broader adoption of modelling and simulation in drug development and advancing personalized medicine. Graphical Abstract


  • Open Access

    Rapid deposition analysis of inhaled aerosols in human airways

    by Hosein Sadafi, Wilfried De Backer, Gabriel Krestin, Jan De Backer

    A rapid data-driven method for determining regional deposition of inhaled medication aerosols in human airways is presented, which is patient specific. Inhalation patterns, device characteristics, and aerodynamic particle size distribution of medications are considered. The method is developed using dimensional analysis and Buckingham Pi theorem, and provides total, regional, and lobar distributions of aerosol deposition. 34 dimensionless quantities are selected, of which 22 encode features of the airway trees and segmented lobes, 14 pertain to the device and the drug formulation, and 13 the inhalation profile of the subject. The dimensionless correlations are obtained using a large database of computational fluid dynamics results on patient specific airways. The intraclass correlation coefficient between the current method and its training dataset is 0.92. The difference between the predicted average lobar deposition in the six asthma patients and the in-vivo data is 1.3%. The model has the potential to offer insights into the effectiveness of personalized drug delivery in clinical settings and can aid in drug development cycles.


  • Inter-patient variability of inhaled medication lung deposition using Functional Respiratory Imaging (FRI)

    by Hosein Sadafi, Navid Monshi Tousi, Jan De Backer

    Background: Inhalation medication is standard for COPD, but the specific lung areas where drugs deposit and the variability of this deposition among patients remain unclear Aims and objectives: The aim of this study is to investigate the effect of inter-patient variability in regional lung deposition of inhaled medications in a group of 20 COPD patients. Methods: Deposition of Fluticasone furoate (FLU) and Vilanterol (VIL) inhaled via a Trelegy Ellipta dry powder inhaler is numerically simulated using FRI. Patients with FEV1% ranged 22.6% to 79.4% and an inhalation profile with mean flow of 30 l/min are considered. Results: The average intrathoracic deposition of FLU constitute 23.99% of the delivered dose (DD). Inter-patient variability may extend up to 10.49% of DD. Furthermore, despite using the same inhaler and inhaling in a similar manner, a patient may experience more than double the peripheral deposition compared to another (Figure 1). Conclusions: In the examination of medication deposition in patient airways, it is important to take into account inter-patient variability. This study indicates that regional deposition can vary by more than half between different patients. It is essential not to disregard the individual characteristics of a patient's airways. Novel tools are increasingly available to assess deposition on a patient-specific level, paving the way for precision medicine.


  • Open Access

    Validation of computational fluid dynamics models for airway deposition with SPECT data of the same population

    by Hosein Sadafi, Navid Monshi Tousi, Wilfried De Backer, Jan De Backer

    This study compared computational fluid dynamic (CFD) model predictions on aerosol deposition in six asthmatic patients to the in-vivo results of the same group. Patient-specific ventilation and internal air distribution were prescribed using inspiratory and expiratory CT scans of each patient, accounting for individual lobar air flow distribution. Moreover, the significant influence of realistic mouth and throat geometries on regional deposition is demonstrated. The in-vivo data were obtained from single photon emission computed tomography (SPECT) in 6 subjects with mild asthma selected from a database of historical clinical trials. The governing flow and particle tracking equations were solved numerically using a commercial CFD tool, and the modeled deposition results were compared to the SPECT data. Good agreement was found between the CFD model, applying k-ω SST turbulence model, and SPECT in terms of aerosol deposition. The average difference for the lobar deposition obtained from CFD model and SPECT/CT data was 2.1%. The high level of agreement is due to applying patient specific airway geometries and inspiratory/expiratory CT images, anatomical upper airways, and realistic airway trees. The results of this study show that CFD is a powerful tool to simulate patient-specific deposition if correct boundary conditions are applied and can generate similar information obtained with functional imaging tools, such as SPECT.


  • Correlation between ventilation heterogeneity and virtual scintigraphy through Functional Respiratory Imaging (FRI)

    by Hosein Sadafi, Maarten Lanclus, Navid Monshi Tousi, Stijn Bonte, Jan De Backer

    Rationale: Ventilation abnormalities in COPD patients diminish exercise tolerance and quality of life. FRI is used to compare regional ventilation in a COPD patient to a healthy control. Methods: A COPD patient is compared with a healthy volunteer with similar demographics. Gated HRCT scans at full inhalation and functional residual capacity are used to estimate tissue deformation maps, from which local ventilation maps are calculated. The airway deposition of ICS, LABA, and LAMA delivered via Nexthaler dry powder inhaler is predicted using Computational Fluid Dynamics. Results: Quantitative pulmonary ventilation is significantly larger in the healthy subject compared to the COPD patient (total expansion factor of 1.76 to 1.16). The intrathoracic deposition for the COPD patient is 13.7% less than the healthy volunteer for the ICS compound. Conclusions: Image-based measures of ventilation and scintigraphy through FRI provide a non-invasive and fast way to assess the regional pulmonary ventilation heterogeneity and resulting deposition.

  • Open Access

    Differential Performance and Lung Deposition of Levofloxacin with Different Nebulisers Used in Cystic Fibrosis

    by Carsten Schwarz, Claudio Procaccianti, Laura Costa, Riccardo Brini, Richard Friend, Grazia Caivano, Hosein Sadafi, Charles Mussche, Nicolas Schwenck, Michael Hahn, et al.

    We compared the performance and levofloxacin (Quinsair) lung deposition of three nebulisers commonly used in CF (I-Neb Advance, eFlow rapid, and LC Plus) with the approved nebuliser Zirela. The delivered dose, delivery rate, and aerosol particle size distribution (APSD) for each device were determined using the methods described in the Pharmacopeia. High-resolution computed tomography scans obtained from seven adult patients with mild CF were used to generate computer-aided, three-dimensional models of their airway tree to assess lung deposition using functional respiratory imaging (FRI). The eFlow rapid and the LC Plus showed poor delivery efficiencies due to their high residual volumes. The I-Neb, which only delivers aerosols during the inspiratory phase, achieved the highest aerosol delivery efficiency. However, the I-Neb showed the largest particle size and lowest delivery rate (2.9 mg/min), which were respectively associated with a high extrathoracic deposition and extremely long nebulisation times (>20 min). Zirela showed the best performance considering delivery efficiency (159.6 mg out of a nominal dose of 240 mg), delivery rate (43.5 mg/min), and lung deposition (20% of the nominal dose), requiring less than 5 min to deliver a full dose of levofloxacin. The present study supports the use of drug-specific nebulisers and discourages the off-label use of general-purpose devices with the present levofloxacin formulation since subtherapeutic lung doses and long nebulisation times may compromise treatment efficacy and adherence.


  • Open Access

    Deposition of Inhaled Levofloxacin in Cystic Fibrosis Lungs Assessed by Functional Respiratory Imaging

    by Carsten Schwarz, Claudio Procaccianti, Benjamin Mignot, Hosein Sadafi, Nicolas Schwenck, Xabier Murgia, Federico Bianco

    Pulmonary infections caused by Pseudomonas aeruginosa (PA) represent the leading cause of pulmonary morbidity in adults with cystic fibrosis (CF). In addition to tobramycin, colistin, and aztreonam, levofloxacin has been approved in Europe to treat PA infections. Nevertheless, no lung deposition data on inhaled levofloxacin are yet available. We conducted a Functional Respiratory Imaging (FRI) study to predict the lung deposition of levofloxacin in the lungs of patients with CF. Three-dimensional airway models were digitally reconstructed from twenty high-resolution computed tomography scans obtained from historical patients’ records. Levofloxacin aerosols generated with the corresponding approved nebuliser were characterised according to pharmacopeia. The obtained data were used to inform a computational fluid dynamics simulation of levofloxacin lung deposition using breathing patterns averaged from actual CF patients’ spirometry data. Levofloxacin deposition in the lung periphery was significantly reduced by breathing patterns with low inspiratory times and high inspiratory flow rates. The intrathoracic levofloxacin deposition percentages for moderate and mild CF lungs were, respectively, 37.0% ± 13.6 and 39.5% ± 12.9 of the nominal dose. A significant albeit modest correlation was found between the central-to-peripheral deposition (C/P) ratio of levofloxacin and FEV1. FRI analysis also detected structural differences between mild and moderate CF airways. FRI revealed a significant intrathoracic deposition of levofloxacin aerosols, which distributed preferentially to the lower lung lobes, with an influence of the deterioration of FEV1 on the C/P ratio. The three-dimensional rendering of CF airways also detected structural differences between the airways of patients with mild and moderate CF.


  • Water pool boiling across low pore density aluminum foams

    by Giulia Righetti, Luca Doretti, Hosein Sadafi, Kamel Hooman, Simone Mancin

    In this paper, experimental data pertinent to deionized water pool boiling across 10 mm thick aluminum foams are presented. Two foam samples with different pore densities, 5 and 10 pores per inch, yet an identical mean porosity of 0.92 are tested. Compared to a heated flat plate, of the same base size, the foams offer higher heat transfer area albeit at induced bubble escaping resistance. The tradeoff between these two effects is investigated. Through the use of high-speed camera recording, bubble generation, trajectory and growth rate were analyzed and critically discussed as functions of the working conditions and of the foam geometry. Furthermore, the experimental data were compared against a correlation appositely proposed for water pool boiling on metal foams. A good degree of agreement was observed.


  • Vapor-Mediated versus Substrate-Mediated Interactions between Volatile Droplets

    by Hosein Sadafi, Sam Dehaeck, Alexey Rednikov, Pierre Colinet

    Understanding the behavior of sessile drops can be well rewarding in many applications, while also fostering progress in the rapidly evolving field of capillarity and wetting. Our experiments reveal that two evaporating sessile drops on a solid substrate do attract even if, unlike the binary-liquid drops recently studied in the literature [Cira et al., Nature, 2015], they are made of the same pure liquid. Several perfectly wetting liquids of different volatilities are tested in order to unveil and quantify the mechanisms enabling droplets to communicate. While all recent works focusing on the topic consider vapor-mediated interactions only, we here identify not less than three substrate-mediated forces driven by the thermal Marangoni effect (favoring droplet motion towards colder regions), and by evaporation-induced variations of the apparent contact angles (acting similarly to a wettability gradient). In addition to an attractive mechanism and a (generally weaker) repelling one, the third effect acts on each droplet individually due to the self-centering cold spot it induces in the substrate. Interestingly, in the force balance used to rationalize our results, this "cold-trap resistance" enters as an effective drag force opposing any motion, like the viscous drag does. The interaction mechanisms described here could hopefully open new directions of research about thermal effects as a mean of self-organizing evaporating/condensing liquid entities on substrates of various shapes and thermal properties.