EFErin Ee Fowler

Erin Ee Fowler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Erin Ee Fowler has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Breast Density Analysis Using Digital Breast Tomosynthesis

    by John Heine, Erin E.E. Fowler, R. Jared Weinfurtner, Emma Hume, Shelley S. Tworoger

    We evaluated an automated percentage of breast density (BD) technique (PD a ) with digital breast tomosynthesis (DBT) data. The approach is based on the wavelet expansion followed by analyzing signal dependent noise. Several measures were investigated as risk factors: normalized volumetric; total dense volume; average of the DBT slices (slice-mean); a two-dimensional (2D) metric applied to the synthetic images; and the mean and standard deviations of the pixel values. Volumetric measures were derived theoretically, and PD a was modeled as a function of compressed breast thickness. An alternative method for constructing synthetic 2D mammograms was investigated using the volume results. A matched case-control study (n = 426 pairs) was analyzed. Conditional logistic regression modeling, controlling body mass index and ethnicity, was used to estimate odds ratios (ORs) for each measure with 95% confidence intervals provided parenthetically. There were several significant findings: volumetric measure [OR = 1.43 (1.18, 1.72)], which produced an identical OR as the slice-mean measure as predicted; [OR =1.44 (1.18, 1.75)] when applied to the synthetic images; and mean of the pixel values (volume or 2D synthetic) [ORs ∼ 1.31 (1.09, 1.57)]. PD a was modeled as 2 nd degree polynomial (concave-down): its maximum value occurred at 0.41×(compressed breast thickness), which was similar across case-control groups, and was significant from this position [OR = 1.47 (1.21, 1.78)]. A standardized 2D synthetic image was produced, where each pixel value represents the percentage of BD above its location. The significant findings indicate the validity of the technique. Derivations supported by empirical analyses produced a new synthetic 2D standardized image technique. Ancillary to the objectives, the results provide evidence for understanding the percentage of BD measure applied to 2D mammograms. Notwithstanding the findings, the study design provides a template for investigating other measures such as texture.


  • Open Access

    Techniques to Produce and Evaluate Realistic Multivariate Synthetic Data

    by John Heine, Erin E.E. Fowler, Anders Berglund, Michael J. Schell, Steven Eschrich

    Background: Data modeling in biomedical-healthcare research requires a sufficient sample size for exploration and reproducibility purposes. A small sample size can inhibit model performance evaluations (i.e., the small sample problem). Objective: A synthetic data generation technique addressing the small sample size problem is evaluated. We show: (1) from the space of arbitrarily distributed samples, a subgroup (class) has a latent multivariate normal characteristic ; (2) synthetic populations (SPs) of unlimited size can be generated from this class with univariate kernel density estimation (uKDE) followed by standard normal random variable generation techniques; and (3) samples drawn from these SPs are statistically like their respective samples. Methods: Three samples (n = 667), selected pseudo-randomly, were investigated each with 10 input variables (i.e., X). uKDE (optimized with differential evolution) was used to augment the sample size in X (i.e., the input variables). The enhanced sample size was used to construct maps that produced univariate normally distributed variables in Y (mapped input variables). Principal component analysis in Y produced uncorrelated variables in T, where the univariate probability density functions (pdfs) were approximated as normal with specific variances; a given SP in T was generated with normally distributed independent random variables with these specified variances. Reversing each step produced the respective SPs in Y and X. Synthetic samples of the same size were drawn from these SPs for comparisons with their respective samples. Multiple tests were deployed: to assess univariate and multivariate normality; to compare univariate and multivariate pdfs; and to compare covariance matrices. Results: One sample was approximately multivariate normal in X and all samples were approximately multivariate normal in Y, permitting the generation of unlimited sized SPs. Uni/multivariate pdf and covariance comparisons (in X, Y and T) showed similarity between samples and synthetic samples. Conclusions: The work shows that a class of multivariate samples has a latent normal characteristic ; for such samples, our technique is a simplifying mechanism that offers an approximate solution to the small sample problem by generating similar synthetic data. Further studies are required to understand this latent normal class, as two samples exhibited this characteristic in the study.


  • Empirically-derived synthetic populations to mitigate small sample sizes

    by Erin E. Fowler, Anders Berglund, Michael J. Schell, Thomas A. Sellers, Steven Eschrich, John Heine


  • Open Access

    Calibrated Breast Density Measurements

    by Erin E. Fowler, Autumn Smallwood, Nadia Khan, Cassandra Miltich, Jennifer Drukteinis, Thomas A. Sellers, John Heine


  • Open Access

    Empirically-Derived Synthetic Populations to Mitigate Small Sample Sizes

    by Erin E. Fowler, Anders Berglund, Michael J. Schell, Thomas A. Sellers, Steven Eschrich, John Heine

    Limited sample sizes can hinder biomedical research and lead to spurious findings. The objective of this work is to present a new method to generate synthetic populations (SPs) from sparse data samples to aid in modeling developments. Matched case-control data (n=180 pairs) defined the limited samples. Cases and controls were considered as two separate limited samples. Synthetic populations were generated for these observed samples using multivariate unconstrained bandwidth kernel density estimations. We included four continuous variables and one categorical variable for each individual. Bandwidth matrices were determined with Differential Evolution (DE) optimization driven by covariance comparisons. Four synthetic samples (n=180) were constructed from their respective SP for comparison purposes. Similarity between the observed samples with equally sized synthetic-samples was compared under the hypothesis that their sample distributions were the same. Distributions were compared with the maximum mean discrepancy (MMD) test statistic based on a Kernel Two-Sample Test. To evaluate similarity within a modeling context, Principal Component Analysis (PCA) score distributions and residuals were summarized with the distance to the model in X-space (DModX) as additional comparisons. Four SPs were generated with the optimization procedure. The probability of selecting a replicate when randomly constructing synthetic samples with n=180 was infinitesimally small. The MMD tests indicated that the observed sample distributions were similar to the respective synthetic distributions. For both case and control samples, PCA scores and residuals did not deviate significantly when compared with their respective synthetic samples. The reasonableness of this SP generation approach was demonstrated. This approach produced synthetic data at the patient level statistically similar to the observed samples, and thus could be used to generate larger-sized simulated data. The methodology coupled kernel density estimation with DE optimization and deployed novel similarity metrics derived from PCA. The use of large-sized synthetic samples may be a way to overcome sparse datasets. To further develop this approach into a research tool for model building purposes, additional evaluation with increased dimensionality is required; moreover, comparisons with other techniques such as bootstrapping and cross-validation will be required for a complete evaluation.

  • Open Access

    Calibrated breast density methods for full field digital mammography: A system for serial quality control and inter‐system generalization

    by B. Lu, A. M. Smallwood, T. A. Sellers, J. S. Drukteinis, J. J. Heine, E. E. E. Fowler

    Purpose:: The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately 160 phantom images, acquired prior to calibrating prospective patient mammograms. BL curves are monitored serially to ensure they produce accurate calibration and require updating when calibration accuracy degrades beyond an acceptable tolerance, rather than acquiring full BL datasets repeatedly. BL updating is a special case of generalizing calibration datasets across FFDM units, referred to as cross‐calibration. Serial monitoring, BL updating, and cross‐calibration techniques were developed and evaluated.Methods:: BL curves were established for three Hologic Selenia FFDM units at time zero. In addition, one set of serial phantom images, comprised of equal proportions of adipose and fibroglandular BTE materials (50/50 compositions) of a fixed height, was acquired biweekly and monitored with the cumulative sum (Cusum) technique. These 50/50 composition images were used to update the BL curves when the calibration accuracy degraded beyond a preset tolerance of ±4 standardized units. A second set of serial images, comprised of a wide‐range of BTE compositions, was acquired biweekly to evaluate serial monitoring, BL updating, and cross‐calibration techniques.Results:: Calibration accuracy can degrade serially and is a function of acquisition technique and phantom height. The authors demonstrated that all heights could be monitored simultaneously while acquiring images of a 50/50 phantom with a fixed height for each acquisition technique biweekly, translating into approximately 16 image acquisitions biweekly per FFDM unit. The same serial images are sufficient for serial monitoring, BL updating, and cross‐calibration. Serial calibration accuracy was maintained within ±4 standardized unit variation from the ideal when applying BL updating. BL updating is a special case of cross‐calibration; the BL dataset of unit 1 can be converted to the BL dataset for another similar unit (i.e., unit 2) at any given time point using the 16 serial monitoring 50/50 phantom images of unit 2 (or vice versa) acquired near this time point while maintaining the ±4 standardized unit tolerance.Conclusions:: A methodology for monitoring and maintaining serial calibration accuracy for breast density measurements was evaluated. Calibration datasets for a given unit can be translated forward in time with minimal phantom imaging effort. Similarly, cross‐calibration is a method for generalizing calibration datasets across similar units without additional phantom imaging. This methodology will require further evaluation with mammograms for complete validation.


  • Open Access

    A comparison of calibration data from full field digital mammography units for breast density measurements

    by Erin Ee Fowler, Beibei Lu, John J Heine

    Background: Breast density is a significant breast cancer risk factor measured from mammograms. The most appropriate method for measuring breast density for risk applications is still under investigation. Calibration standardizes mammograms to account for acquisition technique differences prior to making breast density measurements. We evaluated whether a calibration methodology developed for an indirect x-ray conversion full field digital mammography (FFDM) technology applies to direct x-ray conversion FFDM systems. Methods: Breast tissue equivalent (BTE) phantom images were used to establish calibration datasets for three similar direct x-ray conversion FFDM systems. The calibration dataset for each unit is a function of the target/filter combination, x-ray tube voltage, current × time (mAs), phantom height, and two detector fields of view (FOVs). Methods were investigated to reduce the amount of calibration data by restricting the height, mAs, and FOV sampling. Calibration accuracy was evaluated with mixture phantoms. We also compared both intra- and inter-system calibration characteristics and accuracy. Results: Calibration methods developed previously apply to direct x-ray conversion systems with modification. Calibration accuracy was largely within the acceptable range of ± 4 standardized units from the ideal value over the entire acquisition parameter space for the direct conversion units. Acceptable calibration accuracy was maintained with a cubic-spline height interpolation, representing a modification to previous work. Calibration data is unit specific, can be acquired with the large FOV, and requires a minimum of one reference mAs sample. The mAs sampling, calibration accuracy, and the necessity for machine specific calibration data are common characteristics and in agreement with our previous work. Conclusion: The generality of our calibration approach was established under ideal conditions. Evaluation with patient data using breast cancer status as the endpoint is required to demonstrate that the approach produces a breast density measure associated with breast cancer.


  • Open Access

    Comparison of percent density from raw and processed full-field digital mammography data

    by Celine M Vachon, Erin Ee Fowler, Gail Tiffenberg, Christopher G Scott, V Shane Pankratz, Thomas A Sellers, John J Heine

    Introduction: Mammographic density has been established as a strong risk factor for breast cancer, primarily using digitized film mammograms. Full-field digital mammography (FFDM) is replacing film mammography, has different properties than film, and provides both raw and processed clinical display representation images. We evaluated and compared FFDM raw and processed breast density measures and their associations with breast cancer. Methods: A case-control study of 180 cases and 180 controls matched by age, postmenopausal hormone use, and screening history was conducted. Mammograms were acquired from a General Electric Senographe 2000D FFDM unit. Percent density (PD) was assessed for each FFDM representation using the operator-assisted Cumulus method. Reproducibility within image type (n = 80) was assessed using Lin's concordance correlation coefficient (rc). Correlation of PD between image representations (n = 360) was evaluated using Pearson's correlation coefficient (r) on the continuous measures and the weighted kappa statistic (κ) for quartiles. Conditional logistic regression was used to estimate odds ratios (ORs) for the PD and breast cancer associations for both image representations with 95% confidence intervals. The area under the receiver operating characteristic curve (AUC) was used to assess the discriminatory accuracy. Results: Percent density from the two representations provided similar intra-reader reproducibility (rc= 0.92 for raw and rc= 0.87 for processed images) and was correlated (r = 0.82 and κ = 0.64). When controlling for body mass index, the associations of quartiles of PD with breast cancer and discriminatory accuracy were similar for the raw (OR: 1.0 (ref.), 2.6 (1.2 to 5.4), 3.1 (1.4 to 6.8), 4.7 (2.1 to 10.6); AUC = 0.63) and processed representations (OR: 1.0 (ref.), 2.2 (1.1 to 4.1), 2.2 (1.1 to 4.4), 3.1 (1.5 to 6.6); AUC = 0.64). Conclusions: Percent density measured with an operator-assisted method from raw and processed FFDM images is reproducible and correlated. Both percent density measures provide similar associations with breast cancer.


  • Open Access

    Statistical learning methods as a preprocessing step for survival analysis: evaluation of concept using lung cancer data

    by Madhusmita Behera, Erin E Fowler, Taofeek K Owonikoko, Walker H Land, William Mayfield, Zhengjia Chen, Fadlo R Khuri, Suresh S Ramalingam, John J Heine

    Background: Statistical learning (SL) techniques can address non-linear relationships and small datasets but do not provide an output that has an epidemiologic interpretation. Methods: A small set of clinical variables (CVs) for stage-1 non-small cell lung cancer patients was used to evaluate an approach for using SL methods as a preprocessing step for survival analysis. A stochastic method of training a probabilistic neural network (PNN) was used with differential evolution (DE) optimization. Survival scores were derived stochastically by combining CVs with the PNN. Patients (n = 151) were dichotomized into favorable (n = 92) and unfavorable (n = 59) survival outcome groups. These PNN derived scores were used with logistic regression (LR) modeling to predict favorable survival outcome and were integrated into the survival analysis (i.e. Kaplan-Meier analysis and Cox regression). The hybrid modeling was compared with the respective modeling using raw CVs. The area under the receiver operating characteristic curve (Az) was used to compare model predictive capability. Odds ratios (ORs) and hazard ratios (HRs) were used to compare disease associations with 95% confidence intervals (CIs). Results: The LR model with the best predictive capability gave Az = 0.703. While controlling for gender and tumor grade, the OR = 0.63 (CI: 0.43, 0.91) per standard deviation (SD) increase in age indicates increasing age confers unfavorable outcome. The hybrid LR model gave Az = 0.778 by combining age and tumor grade with the PNN and controlling for gender. The PNN score and age translate inversely with respect to risk. The OR = 0.27 (CI: 0.14, 0.53) per SD increase in PNN score indicates those patients with decreased score confer unfavorable outcome. The tumor grade adjusted hazard for patients above the median age compared with those below the median was HR = 1.78 (CI: 1.06, 3.02), whereas the hazard for those patients below the median PNN score compared to those above the median was HR = 4.0 (CI: 2.13, 7.14). Conclusion: We have provided preliminary evidence showing that the SL preprocessing may provide benefits in comparison with accepted approaches. The work will require further evaluation with varying datasets to confirm these findings.