Yiming Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yiming Gao has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
P Caracappa
Rensselaer Polytechnic Institute, Troy, NY
9 shared publicationsX Xu
Rensselaer Polytechnic Institute, Troy, NY
9 shared publications- Lawrence Thomas Dauer
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, S-1117 (Box 84), 1275 York Avenue, New York, NY 10065, USA, NY, New York, 10065, UNITED STATES
7 shared publications - Aiping Ding
Rensselaer Polytechnic Institute, Troy, NY
6 shared publications B Liu
Rensselaer Polytechnic Inst., Troy, NY
5 shared publicationsX. George Xu
Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY
5 shared publications
Latest Publications
- Open Access
- 11 March 2020
- Published by JMIR Publications Inc. in JMIR Preprints
PACS-based Calculation of Organ Dose to Patients undergoing Chest Computed Tomography with Automatic Tube Current Modulation (Preprint)
BACKGROUND CT imaging is one of the most important contributors to medical radiation exposure(1). The frequency of CT scans and radiation doses accepted by patients attracted serious concerns for health physics researchers. The utilization of advanced technology ATCM has the potentials to reduce CT radiation doses while diagnostic image quality is maintained (2-7). As ATCM adjusted tube currents slice by slice it brought challenges to organ dose estimation using conversion factors derived from fixed tube current. Cross-system communication with hospital Picture Archive and Communication System (PACS),made it possible to read massive data automatically like the scanning parameters of each slice in each case. Monte Carlo simulations are probably the most reliable techniques which could be used for accurate dose assessment. [8-11]. However, specific patient model development and specific patient dose simulations are computationally demanding and may require dedicated hardware resources, this limitation constrained its application in large scale investigation. As an alternative method, patient specific organ doses could be calculated using the patient specific scan parameters and the Monte Carlo simulated organ doses with reference human phantom, and then correct the results with patient size factors. Dw is referred as the preferred patient size metric that determined the patient group and affected organ dose. The distance of the pathway traversed by the X-ray beam could provide the best approximation of tissue length traversed during the examination (12, 13),as CT image is a cross-sectional map normalized to the linear attenuation of water (14). The purpose of current study was to establish a method to access patient-specific organ dose associated with ATCM in chest computed tomography (CT) scans by combining Monte Carlo simulation with parameters contracted from clinical CT images of each patient underwent chest CT scan with ATCM. OBJECTIVE To explore a method to access patient-specific organ dose associated with automatic tube current modulation (ATCM) in chest computed tomography (CT) scans based on the information extracted from PACS automatically. METHODS 176cases of chest CT scans were read through cross-system communication with hospital PACS. A total of 8468 images were collected and analyzed automatically using in-house software. The scanning parameters (kVp, tube current, collimation width, etc.) of each CT examination were collected in real time, and a middle CT image of each case was collected for patient size(water equivalent diameter, Dw) calculation. Based on the reference human phantom, organ doses were simulated slice by slice using Monte Carlo method. The patient specific organ doses were calculated by combining tube currents of each patient slice with the simulated results, and doses were revised by correction factors that related to patient size. RESULTS A sum of 8468 slice of tube currents were extracted and analyzed in this study, the average mAs for large size patient group was about 1.6 times to the small size patient group. For organs that covered in the scan range like lung, breast, heart, the dose values were 18.30±2.91mGy, 15.13 ±2.75mGy and 17.87±2.96mGy in small size patients(Dw smaller than 22cm).The dose values of lung, breast, heart, in medium-sized patients (Dw from 22cm to 25cm) were 21.89±4.60mGy, 18.16 ±4.13mGy and 21.46±4.60mGy, while the values were 24.98±4.40mGy, 20.81±3.66mGy and 24.77±4.46mGy respectively in large size patients(Dw larger than 25cm). The organ doses increase with the patient size due to the increase of mAs. CONCLUSIONS The PACS-based method of large batch organ dose calculation to patients undergoing chest CT with ATCM was established. The methods and results may provide guidance to the design and optimization of chest CT protocols with ATCM.
- 11 March 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessPACS-based Calculation of Organ Dose to Patients undergoing Chest Computed Tomography with Automatic Tube Current Modulation (Preprint)
BACKGROUND CT imaging is one of the most important contributors to medical radiation exposure(1). The frequency of CT scans and radiation doses accepted by patients attracted serious concerns for health physics researchers. The utilization of advanced technology ATCM has the potentials to reduce CT radiation doses while diagnostic image quality is maintained (2-7). As ATCM adjusted tube currents slice by slice it brought challenges to organ dose estimation using conversion factors derived from fixed tube current. Cross-system communication with hospital Picture Archive and Communication System (PACS),made it possible to read massive data automatically like the scanning parameters of each slice in each case. Monte Carlo simulations are probably the most reliable techniques which could be used for accurate dose assessment. [8-11]. However, specific patient model development and specific patient dose simulations are computationally demanding and may require dedicated hardware resources, this limitation constrained its application in large scale investigation. As an alternative method, patient specific organ doses could be calculated using the patient specific scan parameters and the Monte Carlo simulated organ doses with reference human phantom, and then correct the results with patient size factors. Dw is referred as the preferred patient size metric that determined the patient group and affected organ dose. The distance of the pathway traversed by the X-ray beam could provide the best approximation of tissue length traversed during the examination (12, 13),as CT image is a cross-sectional map normalized to the linear attenuation of water (14). The purpose of current study was to establish a method to access patient-specific organ dose associated with ATCM in chest computed tomography (CT) scans by combining Monte Carlo simulation with parameters contracted from clinical CT images of each patient underwent chest CT scan with ATCM. OBJECTIVE To explore a method to access patient-specific organ dose associated with automatic tube current modulation (ATCM) in chest computed tomography (CT) scans based on the information extracted from PACS automatically. METHODS 176cases of chest CT scans were read through cross-system communication with hospital PACS. A total of 8468 images were collected and analyzed automatically using in-house software. The scanning parameters (kVp, tube current, collimation width, etc.) of each CT examination were collected in real time, and a middle CT image of each case was collected for patient size(water equivalent diameter, Dw) calculation. Based on the reference human phantom, organ doses were simulated slice by slice using Monte Carlo method. The patient specific organ doses were calculated by combining tube currents of each patient slice with the simulated results, and doses were revised by correction factors that related to patient size. RESULTS A sum of 8468 slice of tube currents were extracted and analyzed in this study, the average mAs for large size patient group was about 1.6 times to the small size patient group. For organs that covered in the scan range like lung, breast, heart, the dose values were 18.30±2.91mGy, 15.13 ±2.75mGy and 17.87±2.96mGy in small size patients(Dw smaller than 22cm).The dose values of lung, breast, heart, in medium-sized patients (Dw from 22cm to 25cm) were 21.89±4.60mGy, 18.16 ±4.13mGy and 21.46±4.60mGy, while the values were 24.98±4.40mGy, 20.81±3.66mGy and 24.77±4.46mGy respectively in large size patients(Dw larger than 25cm). The organ doses increase with the patient size due to the increase of mAs. CONCLUSIONS The PACS-based method of large batch organ dose calculation to patients undergoing chest CT with ATCM was established. The methods and results may provide guidance to the design and optimization of chest CT protocols with ATCM.
- Open Access
- 29 January 2020
- Published by Springer Nature in BMC Medical Imaging
- Vol. 20 (1) , 1-9
Patient-adapted organ absorbed dose and effective dose estimates in pediatric 18F-FDG positron emission tomography/computed tomography studies
Background: Organ absorbed doses and effective doses can be used to compare radiation exposure among medical imaging procedures, compare alternative imaging options, and guide dose optimization efforts. Individual dose estimates are important for relatively radiosensitive patient populations such as children and for radiosensitive organs such as the eye lens. Software-based dose calculation methods conveniently calculate organ dose using patient-adjusted and examination-specific inputs. Methods: Organ absorbed doses and effective doses were calculated for 429 pediatric 18F-FDG PET-CT patients. Patient-adjusted and scan-specific information was extracted from the electronic medical record and scanner dose-monitoring software. The VirtualDose and OLINDA/EXM (version 2.0) programs, respectively, were used to calculate the CT and the radiopharmaceutical organ absorbed doses and effective doses. Patients were grouped according to age at the time of the scan as follows: less than 1 year old, 1 to 5 years old, 6 to 10 years old, 11 to 15 years old, and 16 to 17 years old. Results: The mean (+/− standard deviation, range) total PET plus CT effective dose was 14.5 (1.9, 11.2–22.3) mSv. The mean (+/− standard deviation, range) PET effective dose was 8.1 (1.2, 5.7–16.5) mSv. The mean (+/− standard deviation, range) CT effective dose was 6.4 (1.8, 2.9–14.7) mSv. The five organs with highest PET dose were: Urinary bladder, heart, liver, lungs, and brain. The five organs with highest CT dose were: Thymus, thyroid, kidneys, eye lens, and gonads. Conclusions: Organ and effective dose for both the CT and PET components can be estimated with actual patient and scan data using commercial software. Doses calculated using software generally agree with those calculated using dose conversion factors, although some organ doses were found to be appreciably different. Software-based dose calculation methods allow patient-adjusted dose factors. The effort to gather the needed patient data is justified by the resulting value of the characterization of patient-adjusted dosimetry.
- 29 January 2020
- Published by Springer Nature in BMC Medical Imaging
- Vol. 20 (1) , 1-9
Open AccessPatient-adapted organ absorbed dose and effective dose estimates in pediatric 18F-FDG positron emission tomography/computed tomography studies
Background: Organ absorbed doses and effective doses can be used to compare radiation exposure among medical imaging procedures, compare alternative imaging options, and guide dose optimization efforts. Individual dose estimates are important for relatively radiosensitive patient populations such as children and for radiosensitive organs such as the eye lens. Software-based dose calculation methods conveniently calculate organ dose using patient-adjusted and examination-specific inputs. Methods: Organ absorbed doses and effective doses were calculated for 429 pediatric 18F-FDG PET-CT patients. Patient-adjusted and scan-specific information was extracted from the electronic medical record and scanner dose-monitoring software. The VirtualDose and OLINDA/EXM (version 2.0) programs, respectively, were used to calculate the CT and the radiopharmaceutical organ absorbed doses and effective doses. Patients were grouped according to age at the time of the scan as follows: less than 1 year old, 1 to 5 years old, 6 to 10 years old, 11 to 15 years old, and 16 to 17 years old. Results: The mean (+/− standard deviation, range) total PET plus CT effective dose was 14.5 (1.9, 11.2–22.3) mSv. The mean (+/− standard deviation, range) PET effective dose was 8.1 (1.2, 5.7–16.5) mSv. The mean (+/− standard deviation, range) CT effective dose was 6.4 (1.8, 2.9–14.7) mSv. The five organs with highest PET dose were: Urinary bladder, heart, liver, lungs, and brain. The five organs with highest CT dose were: Thymus, thyroid, kidneys, eye lens, and gonads. Conclusions: Organ and effective dose for both the CT and PET components can be estimated with actual patient and scan data using commercial software. Doses calculated using software generally agree with those calculated using dose conversion factors, although some organ doses were found to be appreciably different. Software-based dose calculation methods allow patient-adjusted dose factors. The effort to gather the needed patient data is justified by the resulting value of the characterization of patient-adjusted dosimetry.
- 15 August 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 214 (4) , 738-746
Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT
OBJECTIVE. Patient-specific organ and effective dose provides essential information for CT protocol optimization. However, such information is not readily available in the scan records. The purpose of this study was to develop a method to obtain accurate examination- and patient-specific organ and effective dose estimates by use of available scan data and patient body size information for a large cohort of patients. MATERIALS AND METHODS. The data were randomly collected for 1200 patients who underwent CT in a 2-year period. Physical characteristics of the patients and CT technique were processed as inputs for the dose estimator. Organ and effective doses were estimated by use of the inputs and computational human phantoms matched to patients on the basis of sex and effective diameter. Size-based ratios were applied to correct for patient-phantom body size differences. RESULTS. Patients received a mean of 59.9 mGy to the lens of the eye per brain scan, 10.1 mGy to the thyroid per chest scan, 17.5 mGy to the liver per abdomen and pelvis scan, and 19.0 mGy to the liver per body scan. A factor of 2 difference in dose estimates was observed between patients of various habitus. CONCLUSION. Examination- and patient-specific organ and effective doses were estimated for 1200 adult oncology patients undergoing CT. The dose conversion factors calculated facilitate rapid organ and effective dose estimation in clinics. Compared with nonspecific dose estimation methods, patient dose estimations with data specific to the patient and examination can differ by a factor of 2.
- 15 August 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 214 (4) , 738-746
Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT
OBJECTIVE. Patient-specific organ and effective dose provides essential information for CT protocol optimization. However, such information is not readily available in the scan records. The purpose of this study was to develop a method to obtain accurate examination- and patient-specific organ and effective dose estimates by use of available scan data and patient body size information for a large cohort of patients. MATERIALS AND METHODS. The data were randomly collected for 1200 patients who underwent CT in a 2-year period. Physical characteristics of the patients and CT technique were processed as inputs for the dose estimator. Organ and effective doses were estimated by use of the inputs and computational human phantoms matched to patients on the basis of sex and effective diameter. Size-based ratios were applied to correct for patient-phantom body size differences. RESULTS. Patients received a mean of 59.9 mGy to the lens of the eye per brain scan, 10.1 mGy to the thyroid per chest scan, 17.5 mGy to the liver per abdomen and pelvis scan, and 19.0 mGy to the liver per body scan. A factor of 2 difference in dose estimates was observed between patients of various habitus. CONCLUSION. Examination- and patient-specific organ and effective doses were estimated for 1200 adult oncology patients undergoing CT. The dose conversion factors calculated facilitate rapid organ and effective dose estimation in clinics. Compared with nonspecific dose estimation methods, patient dose estimations with data specific to the patient and examination can differ by a factor of 2.
- 26 April 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095012
VirtualDose-IR: a cloud-based software for reporting organ doses in interventional radiology
A cloud-based software, VirtualDose-IR (Virtual Phantoms Inc., Albany, New York, USA), designed to report organ doses and effective doses for a diverse patient population from interventional radiology (IR) procedures has been developed and tested. This software is based on a comprehensive database of Monte Carlo-generated organ dose built with a set of 21 anatomically realistic patient phantoms. The patient types included in this database are both male and female people with different ages reflecting reference adults, obese people with different BMIs and pregnant women at different gestational stages. Selectable parameters such as patient type, tube voltage, filtration thickness, beam direction, field size, and irradiation site are also considered in VirtualDose-IR. The software has been implemented using the ‘Software as a Service (SaaS)’ delivery concept permitting simultaneous multi-user, multi-platform access without requiring local installation. The patient doses resulting from different target sites and patient populations were reported using the VirtualDose-IR system. The patient doses under different source to surface distances (SSD) and beam angles calculated by VirtualDose-IR and Monte Carlo simulations were compared. For most organs, the dose differences between VirtualDose-IR results and Monte Carlo results were less than 0.3 mGy at 15 000 mGy * cm 2 kerma-area product (KAP). The organ dose results were compared with measurement data previously reported in literatures. The doses to organs that were located within the irradiation field match closely with experimental measurement data. The differences in the effective dose values between calculated using VirtualDose-IR and those measured were less than 2.5%. The dose errors of most organs between VirtualDose-IR and literature results were less than 40%. These results validate the accuracy of organ doses reported by VirtualDose-IR. With the inclusion of pre-specified clinical IR examination parameters (such as beam direction, target location, field of view and beam quality) and the latest anatomically realistic patient phantoms in Monte Carlo simulations, VirtualDose-IR provides users with accurate dose information in order to systematically compare, evaluate, and optimize IR plans.
- 26 April 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095012
VirtualDose-IR: a cloud-based software for reporting organ doses in interventional radiology
A cloud-based software, VirtualDose-IR (Virtual Phantoms Inc., Albany, New York, USA), designed to report organ doses and effective doses for a diverse patient population from interventional radiology (IR) procedures has been developed and tested. This software is based on a comprehensive database of Monte Carlo-generated organ dose built with a set of 21 anatomically realistic patient phantoms. The patient types included in this database are both male and female people with different ages reflecting reference adults, obese people with different BMIs and pregnant women at different gestational stages. Selectable parameters such as patient type, tube voltage, filtration thickness, beam direction, field size, and irradiation site are also considered in VirtualDose-IR. The software has been implemented using the ‘Software as a Service (SaaS)’ delivery concept permitting simultaneous multi-user, multi-platform access without requiring local installation. The patient doses resulting from different target sites and patient populations were reported using the VirtualDose-IR system. The patient doses under different source to surface distances (SSD) and beam angles calculated by VirtualDose-IR and Monte Carlo simulations were compared. For most organs, the dose differences between VirtualDose-IR results and Monte Carlo results were less than 0.3 mGy at 15 000 mGy * cm 2 kerma-area product (KAP). The organ dose results were compared with measurement data previously reported in literatures. The doses to organs that were located within the irradiation field match closely with experimental measurement data. The differences in the effective dose values between calculated using VirtualDose-IR and those measured were less than 2.5%. The dose errors of most organs between VirtualDose-IR and literature results were less than 40%. These results validate the accuracy of organ doses reported by VirtualDose-IR. With the inclusion of pre-specified clinical IR examination parameters (such as beam direction, target location, field of view and beam quality) and the latest anatomically realistic patient phantoms in Monte Carlo simulations, VirtualDose-IR provides users with accurate dose information in order to systematically compare, evaluate, and optimize IR plans.
- 7 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (6) , 2744-2751
Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
Purpose: To quantify the effects of operator head posture and different types of protective eyewear on the eye lens dose to operators in interventional radiology (IR).Methods: A deformable computational human phantom, Rensselaer Polytechnic Institute (RPI) Adult Male, consisting of a high‐resolution eye model, was used to simulate a radiologist who is performing an interventional radiology procedure. The radiologist phantom was deformed to a set of different head postures. Three different protective eyewear models were incorporated into the posture‐deformed radiologist phantom. The eye lens dose of the radiologist was calculated using the Monte Carlo code, MCNP. Effects of the radiologist's head posture and different types of protective eyewear on eye lens doses were studied. The relationship between efficacy of protective eyewear and the radiologist's head posture was investigated. Effects of other parameters on efficacy of protective eyewear were also studied, including the angular position of the radiologist, the gap between the eyewear and the face of the radiologist, and the lead equivalent thickness.Results: The dose to both lenses decreased by 80% as the head posture moved from looking downward to looking upward. Sports wrap glasses were found to reduce doses further than the other two studied models. The efficacy of eyewear was found to be related to radiologist's head posture as well. When the radiologist was looking up, the protective eyewear almost provided no protection to both lenses. Other factors such as the face‐to‐eyewear distance and the lead equivalent thickness were also found to have an impact on the efficacy of protective eyewear. The dose reduction factor (DRF), defined as the ratio of the dose to the lens without protection to that with protection, decreased from 4.25 to 1.07 as the face‐to‐eyewear distance increased. The DRF almost doubled when the lead equivalent thickness increased from 0.07 to 0.35 mm. However, further increase in lead equivalent thickness showed little improvement in dose reduction.Conclusion: The radiologist's head posture has a significant influence on the eye lens dose in IR. Sports wrap protective eyewear which conforms to the curve of the face is essential for the radiation protection of the eye lens. However, the radiologist's head posture and other exposure parameters should be considered when evaluating the protection of the radiologist's eyes.
- 7 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (6) , 2744-2751
Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
Purpose: To quantify the effects of operator head posture and different types of protective eyewear on the eye lens dose to operators in interventional radiology (IR).Methods: A deformable computational human phantom, Rensselaer Polytechnic Institute (RPI) Adult Male, consisting of a high‐resolution eye model, was used to simulate a radiologist who is performing an interventional radiology procedure. The radiologist phantom was deformed to a set of different head postures. Three different protective eyewear models were incorporated into the posture‐deformed radiologist phantom. The eye lens dose of the radiologist was calculated using the Monte Carlo code, MCNP. Effects of the radiologist's head posture and different types of protective eyewear on eye lens doses were studied. The relationship between efficacy of protective eyewear and the radiologist's head posture was investigated. Effects of other parameters on efficacy of protective eyewear were also studied, including the angular position of the radiologist, the gap between the eyewear and the face of the radiologist, and the lead equivalent thickness.Results: The dose to both lenses decreased by 80% as the head posture moved from looking downward to looking upward. Sports wrap glasses were found to reduce doses further than the other two studied models. The efficacy of eyewear was found to be related to radiologist's head posture as well. When the radiologist was looking up, the protective eyewear almost provided no protection to both lenses. Other factors such as the face‐to‐eyewear distance and the lead equivalent thickness were also found to have an impact on the efficacy of protective eyewear. The dose reduction factor (DRF), defined as the ratio of the dose to the lens without protection to that with protection, decreased from 4.25 to 1.07 as the face‐to‐eyewear distance increased. The DRF almost doubled when the lead equivalent thickness increased from 0.07 to 0.35 mm. However, further increase in lead equivalent thickness showed little improvement in dose reduction.Conclusion: The radiologist's head posture has a significant influence on the eye lens dose in IR. Sports wrap protective eyewear which conforms to the curve of the face is essential for the radiation protection of the eye lens. However, the radiologist's head posture and other exposure parameters should be considered when evaluating the protection of the radiologist's eyes.
- Open Access
- 9 May 2018
- Published by SAGE Publications in Annals of the ICRP
- Vol. 47 (3-4) , 196-213
Radiotherapeutic implications of the updated ICRP thresholds for tissue reactions related to cataracts and circulatory diseases
Radiation therapy of cancer patients involves a trade-off between a sufficient tumour dose for a high probability of local control and dose to organs at risk that is low enough to lead to a clinically acceptable probability of toxicity. The International Commission on Radiological Protection (ICRP) reviewed epidemiological evidence and provided updated estimates of ‘practical’ threshold doses for tissue injury, as defined at the level of 1% incidence, in ICRP Publication 118 . Particular attention was paid to cataracts and circulatory diseases. ICRP recommended nominal absorbed dose threshold for these outcomes as low as 0.5 Gy. Threshold doses for tissue reactions can be reached in some patients during radiation therapy. Modern treatment planning systems do not account for such low doses accurately, and doses to therapy patients from associated imaging procedures are not generally accounted for. While local control is paramount, the observations of ICRP Publication 118 suggest that radiation therapy plans and processes should be examined with particular care. The research needs are discussed in this paper.
- 9 May 2018
- Published by SAGE Publications in Annals of the ICRP
- Vol. 47 (3-4) , 196-213
Open AccessRadiotherapeutic implications of the updated ICRP thresholds for tissue reactions related to cataracts and circulatory diseases
Radiation therapy of cancer patients involves a trade-off between a sufficient tumour dose for a high probability of local control and dose to organs at risk that is low enough to lead to a clinically acceptable probability of toxicity. The International Commission on Radiological Protection (ICRP) reviewed epidemiological evidence and provided updated estimates of ‘practical’ threshold doses for tissue injury, as defined at the level of 1% incidence, in ICRP Publication 118 . Particular attention was paid to cataracts and circulatory diseases. ICRP recommended nominal absorbed dose threshold for these outcomes as low as 0.5 Gy. Threshold doses for tissue reactions can be reached in some patients during radiation therapy. Modern treatment planning systems do not account for such low doses accurately, and doses to therapy patients from associated imaging procedures are not generally accounted for. While local control is paramount, the observations of ICRP Publication 118 suggest that radiation therapy plans and processes should be examined with particular care. The research needs are discussed in this paper.
- 1 May 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 102, 102-108
Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams
- 1 May 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 102, 102-108
Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams
- 1 April 2018
- Published by Elsevier in Physica Medica
- Vol. 48, 72-75
Monte Carlo simulation of eye lens dose reduction from CT scan using organ based tube current modulation
- 1 April 2018
- Published by Elsevier in Physica Medica
- Vol. 48, 72-75
Monte Carlo simulation of eye lens dose reduction from CT scan using organ based tube current modulation
- Open Access
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 146-155
Patient-specific organ and effective dose estimates in pediatric oncology computed tomography
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 146-155
Open AccessPatient-specific organ and effective dose estimates in pediatric oncology computed tomography
- Open Access
- 1 November 2017
- Published by Elsevier in Physica Medica
- Vol. 43, 186-189
Radiological protection for pregnant women at a large academic medical Cancer Center
- 1 November 2017
- Published by Elsevier in Physica Medica
- Vol. 43, 186-189
Open AccessRadiological protection for pregnant women at a large academic medical Cancer Center