    A Customized Reinforced 8-French Ureteral Stent with End-Piece to Decrease Ureteral Obstruction and Alleviate Stent-Related Symptoms: Evaluation of 92 Patients with 319 Ureteral Stent Procedures

    by Benoît Vogt

    Introduction: The most common method for releasing renal obstruction consists of the placement of an indwelling double-pigtail stent. However, adequate insertion of the stent through an obstructed ureter does not necessarily guarantee renal decompression. Most studies have concluded that the stiffness and lumen diameter of stents are major factors for maintaining their patency. Nonetheless, such stents are also poorly tolerated, severely impairing the patients’ quality of life. We aimed to evaluate the efficiency and tolerance of a customized reinforced 8-French stent in a consecutive series of 92 patients. Materials and Methods: Ninety-two consecutive patients with ureteral obstruction were fitted with a customized stent derived from the same reinforced 8-French double-pigtail stent (8F, Superglide Tumor DD Ureter Stent, Teleflex Medical, Ireland). The stent was modified by truncation and adjustment of its length to that of the patient’s ureter, and the bladder loop was replaced with an end-piece. A ureteral stent procedure (USP) was performed every six months. Stent failure with ureteral obstruction was defined by the presence of renal colic or renal failure with increased serum creatinine or hydronephrosis confirmed by computerized tomography or ultrasound with/without pyelonephritis. Obstruction of the stents in less than six months motivated the switch to 8-French tandem stents. The Ureteral Stent Symptom Questionnaire (USSQ) was used to evaluate the results. Results: During the study period, 319 USPs were separately analyzed. The procedure was bilateral in 32.6% (428 ureteral units) of cases, and a tandem procedure was used in 21.7%. Stent failure with obstruction occurred in 5.0% (16/319) of USPs after a mean of 4.7 ± 2.4 months. Of the 69 patients with malignant disease, 43 (62.3%) died, with mean survival of 29.8 ± 25.7 months after the first USP. We encountered no difficulties in placing the customized stents. The results of the USSQ suggested the effectiveness of the customized stent in attenuating stent-related symptoms. Conclusion: Our results confirm that ureteral stent obstruction decreases with a larger lumen and a stiffer stent. The absence of repeated obstructions appears to improve the survival of patients with malignant disease, but this finding requires validation in a prospective randomized controlled trial. Future stents should integrate these important stent characteristics.

  • Open Access

    Catheter-Free Urodynamics Testing: Current Insights and Clinical Potential

    by Benoît Vogt

    Lower urinary tract dysfunction not only interferes with the health-related quality of life of patients but may also lead to acute kidney injury and infections. To assess the bladder, urodynamic studies (UDS) have been implemented but the use of catheters leads to discomfort for the patient. Catheter-free long-term UDS would be useful and a potential solution could be ambulatory wireless devices that communicate via telemetry. Such sensors can detect pressure or volume. Numerous types of potential catheter-free sensors have been proposed for bladder monitoring. Despite substantial innovation in the manufacturing of implantable biomedical electronic systems, such sensors have remained at the laboratory stage due to a number of critical challenges. These challenges primarily concern hermeticity and biocompatibility, sensitivity and artifacts, drift, telemetry, and energy management. Having overcome these challenges, catheter-free ambulatory urodynamic monitoring could combine a synchronized intravesical pressure sensor with a volume analyzer but only the steps of cystometry and volume measurement are currently sufficiently reproducible to simulate UDS results. The measurement of volume by infrared optical sensors, in the form of abdominal patches, appears to be promising and studies are underway to market a telemetric ambulatory urodynamic monitoring system that includes an intravesical pressure sensor. There has been considerable progress in wearable and conformable electronics on many fronts, and continued collaboration between engineers and urologists could quickly overcome current challenges. In addition, to the diagnosis of UDS, such sensors could be useful in the development of a long-term closed-loop neuromodulation system. In this review, we explore the various types of catheter-free bladder sensors, inherent challenges and solutions to overcome these challenges, and the clinical potential of such long-term implantable sensors.


  • Open Access

    It is Possible to Reduce Ureteral Stent Clogging and Stent-Related Symptoms to Soothe the Pain of the Patient: A Case Report

    by Benoît Vogt, Janine Dove-Rumé

    Introduction: Ureteral stent obstruction hinders the management of malignant diseases. Adequate stent insertion through an obstructed ureter does not necessarily guarantee renal decompression and stent-related symptoms adversely affect patient comfort. There are two major problems associated with ureteral stents: obstruction and intolerance to the stents. Case Presentation: A 45-year-old woman was treated for cervical cancer with metastatic lymph nodes and ureteral obstruction with chemotherapy, radiotherapy, immunotherapy, and bilateral retrograde stenting. After recurrent stent obstruction, stent replacement was attempted more than 18 times over two years. In addition, stent-related symptoms adversely affected patient comfort. The patient was finally fitted with Superglide 8-French reinforced ureteral stents. Their replacement every six months was viewed by the patient as a relief compared to the all too frequent replacement of the previous stents. Moreover, the customized changes in the shape of Superglide stents improved patient comfort. Discussion: Recent publications tend to indicate that large-lumen ureteral stents are most likely to remain permeable over time. Various modifications of the bladder or endo-ureteral part of double-pigtail stents have been increasingly reported, with the aim of improving their tolerance while maintaining effective drainage. Conclusion: Adaptation of the internal lumen and shape of stents to the characteristics of the tumor and patient measurements appears to be important for increasing the drainage and tolerance of ureteral stents. The top priority for future ureteral stents suitable for malignant diseases should be to integrate these characteristics based on state-of-the-art data.


  • Open Access

    Investigating the encrustation of reinforced ureteral stents by computational flow dynamic simulations

    by Benoît Vogt

    Purpose: In cases of extrinsic ureteral obstruction, obstruction due to encrustation is particularly detrimental to functioning of the stent. A thorough understanding of the causes that lead to stent encrustation is essential. Computational fluid dynamic (CFD) simulations may provide a reliable screening platform for investigating the interplay between flow processes and encrustation dynamics in stents. Methods: Using a tailor-made program, we attempted to evaluate a number of reinforced ureteral stents by CFD simulations with an obstructed or unobstructed ureter and steady or discontinuous flow patterns to identify critical regions with abrupt changes in shape susceptible to stagnant flow and encrustation. Results: For the Vortek® and Urosoft stents, the longitudinal opening of the stents confirmed the presence of critical regions. No critical region was observed for the Superglide stent. CFD simulations showed that cavities formed near the critical regions represented patently stagnant flow and were potentially susceptible to the formation of encrusting deposits. Encrustations were greater in the obstructed design than in the unobstructed design. In the model with a suddenly interrupted laminar flow, the peristaltic motion resulted in new discontinuous encrustation areas scattered throughout the entire external and internal surface of the stent. Conclusion: The analysis of fluid dynamics through the tested stents confirmed that encrustations are possible in regions of stagnant flow and showed that stent models with the smoothest possible surface are preferable. The discontinuous flow model provided results that are closer to the findings observed in the clinic and should be more often integrated into CFD simulations.


  • Open Access

    Analysis of Ureteral Tumour Stents for Malignant Ureteral Obstruction: Towards Reshaping an Optimal Stent

    by Benoît Vogt, Laure-Hélène Blanchet

    Introduction: Ureteral obstruction hinders the management of malignant diseases. Adequate stent placement does not necessarily guarantee renal decompression. The stent stiffness may play a major role to maintain patency. We carried out the present study in order to evaluate drainage efficiency by using stents with distinctive degrees of stiffness and to identify the physical factors that could prevent obstruction of the stent in patients with malignant ureteral obstruction (MUO). Materials and Methods: We performed an analysis of 150 patients with MUO drainage at a single institution from June 2009 to June 2019. A progressive choice of stents was shaped to overcome each failure by focusing on the criterion of increasingly stiff stents. Results: During the study period, 556 ureteral stent procedures (USP) were analysed separately. The stent failure with obstruction occurred in 23.0% (128/556) of USP at a mean of 4.4± 3.6 months and depended on the type of stent. Stent failure occurred in 34.2% (70/205) of Vortek® stents, in 42.9% (15/35) of Urosoft stents, in 15.4% (39/254) of Superglide or ureteral catheters and in 6.5% (4/62) of tandem stents. No significant differences were found between Vortek® and Urosoft stents regarding stent failures, but there were significant differences between Superglide or Tandem stents and Vortek® or Urosoft stents (p< 10− 7). The study demonstrated that ureteral stent obstruction significantly decreased with a larger lumen or a stiffer stent (p< 10− 7). Conclusion: In the present study, Superglide and tandem stents were the best stents against stent failure, and the lumen and the stiffness of the stent have been shown to be critical factors in controlling patency. The results suggest that the lumen seems more important than the stiffness, and the stiffness would be the only means of keeping the lumen intact. Future stents for MUO should integrate the importance of the lumen of the stent.


  • Open Access

    10-Year Experience with Reinforced Ureteral Stents for Malignant Ureteral Obstruction

    by Benoît Vogt, Laure-Hélène Blanchet

    Introduction: Malignant ureteral obstruction (MUO) hinders the management of malignant diseases. Indwelling stent is a common method to release renal obstruction, but stent failure with obstruction is frequent. The studies conclude that stent obstruction divides survival by 2 or even 4. We carried out the present study in order to evaluate drainage efficiency and overall survival by using stents with distinctive degrees of stiffness. Materials and Methods: We performed an analysis of 156 patients with MUO drainage at a single institution from June 2009 to June 2019. Results: Of the 156 patients, 128 (82.1%) died with a mean survival time of 15.3 ± 14.4 months after the first ureteral stent procedure (USP). In order to study stent failure and overall survival, the patients were divided into 3 groups. Group 1 with patients died soon after only one USP (n=37). Group 2 with patients had more than one USP and no obstruction (n=41). Patients in Group 3 had more than one USP and at least one stent obstruction (n=62). During the study period, 556 USPs were analysed separately. The stent failure with obstruction occurred in 23.0% (128/556) of USP at a mean of 4.4 ± 3.6 months. In case of stent failure, a progressive choice of stents was shaped to overcome each failure by focusing on the criterion of increasingly stiff stents. Patients in Group 1 died soon at mean of 4.9 ± 4.8 months. The mean survival time of patients in Groups 2 and 3 were, respectively, 19.4 ± 11.2 and 21.5 ± 16.3 months (P = 0.19). Conclusion: MUO is a serious disease but this study is the first to prevent survival rate from falling by choosing the stent stiffness suitable for the patient. The active detection of stent failure has been shown to be essential for preserving survival.


  • Open Access

    Characterization of Sonic Hedgehog/Gli1 Signal Expression in Human Ureter Either Un-Stented or Fitted with Double-Pigtail Stent or a Thread

    by Benoît Vogt, Ilham Chokri

    Introduction: The Sonic Hedgehog/Gli1 signal is involved in smooth muscle activity. An experiment showed that the double-pigtail stent caused ureteral inflammation and decreased Gli1 expression in smooth muscle cells. The innovative pigtail-suture stent (JFil® or MiniJFil®) with a thin 0.3F suture thread significantly decreased stent-related symptoms. Fortuitously, a dilation of the ureter containing the sutures was discovered, and a previous study confirmed that the sutures caused less ureteral inflammation than the double-pigtail stent. However, the mechanisms involved in the ureteral dilation are still unknown. In this study, we assessed ureteral Gli1 expression in the human ureter when it was un-stunted or when fitted with a double-pigtail stent or a suture thread. Material and Methods: After consent and inclusion of patients in the protocol, nine segments of ureters were collected during cystectomy procedures for bladder cancers. There was no selection or exclusion, and patients with large tumors were included. Gli1 expression was assessed on the histological section to control the reflection of an active hedgehog signal. The expression of Gli1 in smooth muscle cells of the stented ureter was subjectively compared to un-stented ureter. Results: A decrease in the intensity of Gli1 expression of smooth muscle cells was observed in all cases of ureter fitted with a double-pigtail stent. For the un-stunted ureters and the ureters fitted with the thin 0.3F suture thread, Gli1 staining of smooth muscle cells was heterogeneous, and the small number of cases did not allow us to conclude. Conclusion: Apart from the cases of ureters fitted with the double-pigtail stent, Gli1 expression of smooth muscle was heterogeneous. The Shh/Gli1 pathway may not be involved in ureteral dilation by the thread. A broader exploration of molecular mechanisms could make it possible to obtain the mechanisms involved in the dilation of the ureter by the thread.


  • Open Access

    Stiffness Analysis of Reinforced Ureteral Stents Against Radial Compression: In vitro Study

    by Benoît Vogt

    Introduction: Malignant ureteral obstruction caused by cancer diseases may induce renal failure. Indwelling stent is a popular method to release renal obstruction. But adequate stent placement across an obstructed ureter does not necessarily guarantee renal decompression. The aim of the study was to compare, in vitro, the physical characteristics and stiffness of several commercially available reinforced ureteral stents and identify the physical factors that could lead to the obstruction of the stent. Material and Methods: The test apparatus used for measurements allowed applying a radial compression force on a segment of the stent to stop a water flow through the lumen of the stent. Some reinforced double-pigtail stents Teleflex Medical, Bard, and Coloplast were evaluated. Results: The best physical-stiffness characteristic was obtained with the Teleflex 8F stent (5.4 N mm− 2). The best result against the radial compression was obtained with tandem stents. The radial compressive stresses of the Teleflex stents (4.4 to 5.4 N mm− 2) were higher than with the other stents used in the study (1.0 to 2.9 N mm− 2). Among the reinforced stents selected in the present study, a wider inner diameter helped increase volumetric flow rate but did not affect the stiffness of the stent. The measurement of inner diameter showed heterogeneity along the tube of some stents. Conclusion: The stiffness of the stent appeared to be an important factor to maintain patency with respect to radial compression forces but the inner diameter of the stent and its preservation may be essential parameters to increase the volumetric flow rate. Some reinforced stents tested in the present study confirmed that it is possible to combine stiffness and wide lumen. The use of tandem stents provided the best stiffness against radial compression and the greatest lumen.


  • Open Access

    Histological Inflammation in Human Ureter either Healthy or Fitted with Double-Pigtail Stent or a Thin 0.3 F Suture Thread: A Preliminary Study

    by Benoît Vogt, Ilham Chokri

    Background. Ureteral stent intolerance reduces patients' quality of life. It has been suggested that changes in the shape of stents could decrease discomfort. In previous studies, the innovative pigtail-suture stent (i.e., JFil (R) or MiniJFil (R)) with a thin 0.3 F suture thread significantly decreased stent-related symptoms. Fortuitously, a dilation of the ureter containing the sutures was discovered. In addition, no inflammation was seen on the ureter wall around the suture in endoscopy. In this preliminary study, we assessed ureteral inflammation in the human ureter when it was healthy or when fitted with a double-pigtail stent or a thread.Materials and Methods. After consent and inclusion of patients in the protocol, fifteen segments of ureters were collected during cystectomy procedures for bladder tumors. Ureteral inflammation was assessed on the histological section stained with hematoxylin-eosin. Histological grading (cumulative range of 0 to 6) assessing inflammation was performed on the ureter section for mucosa inflammation and inflammation in the muscle layer.Results. A marked ureteral inflammatory reaction was observed in all cases of ureters fitted with a double-pigtail stent with a mean inflammation score of 4.8 +/- 0.4. The ureter fitted with the thin suture thread showed inflammation in only one case with a mean inflammation score of 1.8 +/- 1.3 (p=0.001). Conclusion. Although the study was limited by the small number of patients, it confirmed that the double-pigtail stent induced ureteral inflammation in all cases and the thin 0.3 F suture thread caused less ureteral inflammation than the double-pigtail stent. The concept of material reduction within the urinary tract seems necessary in order to decrease mucosal irritation. The JFil (R) or the MiniJFil (R) thread could meet this requirement.