Josep Jordana
Josep Jordana has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Manel Gasulla
Department of Electronic Engineering, Universitat Politcnica de CatalunyaBarcelonaTech, Castelldefels, Barcelona, Spain
8 shared publications Ramon Pallàs-Areny
7 shared publications- Ferran Reverter
Department of Electronic Engineering, Universitat Politècnica de Catalunya—BarcelonaTech, 08860 Castelldefels, Spain
6 shared publications R. Pallas-Areny
6 shared publications- Josep María Torrents
Universitat Politecnica de Catalunya
4 shared publications Óscar Casas
Instrumentation, Sensors and Interfaces Group, Technical School of Castelldefels, Department of Electronic Engineering , Technical University of Catalonia (UPC), Avenida del Canal Olímpic s/n, 08860 Castelldefels (Barcelona), Spain
3 shared publications
Latest Publications
- Open Access
- 1 April 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 224, 185-191
Direct inductive sensor-to-microcontroller interface circuit
- 1 April 2015
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 224, 185-191
Open AccessDirect inductive sensor-to-microcontroller interface circuit
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 1251-1254
Microcontroller-based Interface Circuit for Inductive Sensors
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 1251-1254
Open AccessMicrocontroller-based Interface Circuit for Inductive Sensors
- Open Access
- 1 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21659559,p. 395-400
Cooperative work and continuous assessment in an Electronic Systems laboratory course in a Telecommunication Engineering degree
Electronic laboratory courses offer the possibility to introduce some specific and transversal skills to the curriculum of the students who follow an engineering degree. This paper examines the methodology and assessment which are applied in the laboratory course of the subject “Electronic Systems” in the second year course in the Telecommunication Engineering degree from the Castelldefels School of Technologyy (Escola Politècnica Superior de Castelldefels, EPSC) at the Universitat Politècnica de Catalunya (UPC). During 14 laboratory weekly sessions of 2 h, students must analyze and design the analog and digital circuitry for an ultrasound-based distance measurement system, by means of several guided practices. Small groups of two or three students worked on a collaborative way, while the teacher acted as a guide to facilitate project comprehension and knowledge acquisition. The experience we describe corresponds to the Spring term of 2009, a period in which this methodology was applied to two small class groups of about 23 and 7 students respectively. This work studies the influence of the initial characteristics of the students and their time devoted to prepare the subject, on their academic performance. The paper finishes with a list of recommendations in order to improve students learning process and course assessment.
- 1 April 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21659559,p. 395-400
Open AccessCooperative work and continuous assessment in an Electronic Systems laboratory course in a Telecommunication Engineering degree
Electronic laboratory courses offer the possibility to introduce some specific and transversal skills to the curriculum of the students who follow an engineering degree. This paper examines the methodology and assessment which are applied in the laboratory course of the subject “Electronic Systems” in the second year course in the Telecommunication Engineering degree from the Castelldefels School of Technologyy (Escola Politècnica Superior de Castelldefels, EPSC) at the Universitat Politècnica de Catalunya (UPC). During 14 laboratory weekly sessions of 2 h, students must analyze and design the analog and digital circuitry for an ultrasound-based distance measurement system, by means of several guided practices. Small groups of two or three students worked on a collaborative way, while the teacher acted as a guide to facilitate project comprehension and knowledge acquisition. The experience we describe corresponds to the Spring term of 2009, a period in which this methodology was applied to two small class groups of about 23 and 7 students respectively. This work studies the influence of the initial characteristics of the students and their time devoted to prepare the subject, on their academic performance. The paper finishes with a list of recommendations in order to improve students learning process and course assessment.
- 1 February 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 127 (1) , 69-73
A simple, efficient interface circuit for piezoresistive pressure sensors
- 1 February 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 127 (1) , 69-73
A simple, efficient interface circuit for piezoresistive pressure sensors
- 1 May 2005
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 121 (1) , 78-87
Accuracy and resolution of direct resistive sensor-to-microcontroller interfaces
- 1 May 2005
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 121 (1) , 78-87
Accuracy and resolution of direct resistive sensor-to-microcontroller interfaces
- 1 December 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (12) , 5106-5111
Optimal two-point static calibration of measurement systems with quadratic response
Measurement devices and instruments must be calibrated after manufacture to correct for component and assembly tolerances, and periodically to correct for drift and aging effects. The number of reference inputs needed for calibration depends on the actual transfer characteristic and the desired accuracy. Often, a linear characteristic is assumed for simplicity, either for the overall input range (global linearization) or for successive input subranges (piecewise linearization). Thus, only two reference inputs are needed for each straight line. This two-point static calibration can be easily implemented in any system having some basic computation capability and allows for the correction of zero and gain errors, and of their drifts if the system is periodically calibrated. Often, the reference inputs for that calibration are the end values of the measurement range (or subrange). However, this is not always the optimal selection because the calibration error is minimal for those reference inputs only, which are not necessarily the most relevant inputs for the system being considered. This article proposes three optimization criteria for the selection of calibration points: limiting the maximal error (LME), minimizing the integral square error (ISE), and minimizing the integral absolute error (IAE). Each of these criteria needs reference inputs whose values are symmetrical with respect to the midrange input (xc), have the form xc±Δx/(2√n) when the measurand has a uniform probability distribution function, Δx being the measurement span, and do not depend on the nonlinearity of the actual response, provided this is quadratic. The factor n depends on the particular criterion selected: n=2 for LME, n=3 for ISE, and n=4 for IAE. These three criteria give parallel calibration lines and can also be applied to other nonlinear responses by dividing the measurement span into convenient intervals. The application of those criteria to the linearization of a type-J thermocouple illustrate their performance and advantages with respect to the customary end-point linearization (n=1) even for nonquadratic responses. For quadratic responses, n=1 yields the maximal error at the center of the input measurement range.
- 1 December 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (12) , 5106-5111
Optimal two-point static calibration of measurement systems with quadratic response
Measurement devices and instruments must be calibrated after manufacture to correct for component and assembly tolerances, and periodically to correct for drift and aging effects. The number of reference inputs needed for calibration depends on the actual transfer characteristic and the desired accuracy. Often, a linear characteristic is assumed for simplicity, either for the overall input range (global linearization) or for successive input subranges (piecewise linearization). Thus, only two reference inputs are needed for each straight line. This two-point static calibration can be easily implemented in any system having some basic computation capability and allows for the correction of zero and gain errors, and of their drifts if the system is periodically calibrated. Often, the reference inputs for that calibration are the end values of the measurement range (or subrange). However, this is not always the optimal selection because the calibration error is minimal for those reference inputs only, which are not necessarily the most relevant inputs for the system being considered. This article proposes three optimization criteria for the selection of calibration points: limiting the maximal error (LME), minimizing the integral square error (ISE), and minimizing the integral absolute error (IAE). Each of these criteria needs reference inputs whose values are symmetrical with respect to the midrange input (xc), have the form xc±Δx/(2√n) when the measurand has a uniform probability distribution function, Δx being the measurement span, and do not depend on the nonlinearity of the actual response, provided this is quadratic. The factor n depends on the particular criterion selected: n=2 for LME, n=3 for ISE, and n=4 for IAE. These three criteria give parallel calibration lines and can also be applied to other nonlinear responses by dividing the measurement span into convenient intervals. The application of those criteria to the linearization of a type-J thermocouple illustrate their performance and advantages with respect to the customary end-point linearization (n=1) even for nonquadratic responses. For quadratic responses, n=1 yields the maximal error at the center of the input measurement range.
- 1 February 2004
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 110 (1-3) , 439-446
Trigger uncertainty in period-to-code converters based on counters embedded in microcontrollers
- 1 February 2004
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 110 (1-3) , 439-446
Trigger uncertainty in period-to-code converters based on counters embedded in microcontrollers
- 1 January 2004
- Published by Springer Nature in Mathematical Geology
- Vol. 36 (1) , 127-141
Applicability of a Backprojection Algorithm to Reconstruct Images of Subsurface Horizontal Planes for Laboratory Experiments in Electrical Resistance Tomography
- 1 January 2004
- Published by Springer Nature in Mathematical Geology
- Vol. 36 (1) , 127-141
Applicability of a Backprojection Algorithm to Reconstruct Images of Subsurface Horizontal Planes for Laboratory Experiments in Electrical Resistance Tomography