Leonid V. Danyushevsky
Research Subjects
Research Interests
Leonid V. Danyushevsky has a total of 450 co-authors. Here are the top co-authors by number of shared publications:
- Ross Raymond Large
CODES Centre for Ore Deposits and Earth Sciences, Private Bag 79, University of Tasmania, Tasmania 7001, Australia
23 shared publications - Trevor J. Falloon
University of Tasmania
16 shared publications - Sarah Gilbert
Adelaide University (Adelaide, Australia)
13 shared publications - Sebastien Meffre
CODES and Earth Sciences, University of Tasmania
12 shared publications - Vadim S. Kamenetsky
Institute of Oceanology Chinese Academy of Sciences Qingdao China
9 shared publications - Jon D. Woodhead
School of Geography, Earth and Atmospheric Sciences, University of Melbourne, Melbourne, Australia
8 shared publications
Latest Publications
- 27 July 2025
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 49 (3) , 457-493
GGR Handbook of Rock and Mineral Analysis Chapter 12 Laser Ablation‐ICP‐MS for the In Situ Analysis of Geological Samples
This chapter (Laser Ablation‐ICP‐MS for the In Situ Analysis of Geological Samples) is a contribution to the Geostandards and Geoanalytical Research Handbook of Rock and Mineral Analysis – an online textbook that is a fully revised and updated edition of A Handbook of Silicate Rock Analysis (P. J. Potts, 1987, Blackie, Glasgow).This Chapter (from Section 3 of the handbook dealing with microbeam analytical techniques) presents an overview of fundamental aspects of laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and its application relevant to multi‐element measurement and U‐Pb dating of geological samples. The chapter describes instrumentation currently used for LA‐ICP‐MS, physical processes that occur at the ablation site, during aerosol transport and in the ICP, and approaches to quantification of LA‐ICP‐MS data. Description of laser ablation microprobes focuses on their design aspects that affect analytical performance such as the source of laser light, configuration of the optical path of the laser beam, and the design of the sample cell. Description of ICP‐MS instruments focuses on the implications of using single collector mass spectrometers, which are currently the most common type of ICP‐MS instruments used for LA‐ICP‐MS. Description of the tubing connecting laser microprobes to ICP‐MS instruments focuses on the impact of its configuration on the uncertainty of LA‐ICP‐MS measurement results. The description of physical processes includes aspects of the ablation process, digestion of laser ablation aerosol in a dry ICP, and down‐hole fractionation during ablation at a fixed location on the sample. Description of approaches to quantification of LA‐ICP‐MS data covers internal standardisation, calibration of ICP‐MS instrument response during analytical runs, matrix effects, use of secondary reference material, interferences and memory effects.
- 27 July 2025
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 49 (3) , 457-493
GGR Handbook of Rock and Mineral Analysis Chapter 12 Laser Ablation‐ICP‐MS for the In Situ Analysis of Geological Samples
This chapter (Laser Ablation‐ICP‐MS for the In Situ Analysis of Geological Samples) is a contribution to the Geostandards and Geoanalytical Research Handbook of Rock and Mineral Analysis – an online textbook that is a fully revised and updated edition of A Handbook of Silicate Rock Analysis (P. J. Potts, 1987, Blackie, Glasgow).This Chapter (from Section 3 of the handbook dealing with microbeam analytical techniques) presents an overview of fundamental aspects of laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and its application relevant to multi‐element measurement and U‐Pb dating of geological samples. The chapter describes instrumentation currently used for LA‐ICP‐MS, physical processes that occur at the ablation site, during aerosol transport and in the ICP, and approaches to quantification of LA‐ICP‐MS data. Description of laser ablation microprobes focuses on their design aspects that affect analytical performance such as the source of laser light, configuration of the optical path of the laser beam, and the design of the sample cell. Description of ICP‐MS instruments focuses on the implications of using single collector mass spectrometers, which are currently the most common type of ICP‐MS instruments used for LA‐ICP‐MS. Description of the tubing connecting laser microprobes to ICP‐MS instruments focuses on the impact of its configuration on the uncertainty of LA‐ICP‐MS measurement results. The description of physical processes includes aspects of the ablation process, digestion of laser ablation aerosol in a dry ICP, and down‐hole fractionation during ablation at a fixed location on the sample. Description of approaches to quantification of LA‐ICP‐MS data covers internal standardisation, calibration of ICP‐MS instrument response during analytical runs, matrix effects, use of secondary reference material, interferences and memory effects.
- Open Access
- 19 January 2024
- Published by Elsevier in Environmental Pollution
- Vol. 344, 123415
Development of matrix-specific standards for LA-ICP-MS zinc analysis in sand flathead (Platycephalus bassensis)
- 19 January 2024
- Published by Elsevier in Environmental Pollution
- Vol. 344, 123415
Open AccessDevelopment of matrix-specific standards for LA-ICP-MS zinc analysis in sand flathead (Platycephalus bassensis)
- Open Access
- 21 December 2023
- Published by Taylor & Francis in Australian Journal of Earth Sciences
- Vol. 71 (2) , 231-250
Geology of the Mutis Complex, Miomaffo, West Timor
- 21 December 2023
- Published by Taylor & Francis in Australian Journal of Earth Sciences
- Vol. 71 (2) , 231-250
Open AccessGeology of the Mutis Complex, Miomaffo, West Timor
- Open Access
- 13 June 2023
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 47 (3) , 493-508
STDGL3, a Reference Material for Analysis of Sulfide Minerals by Laser Ablation ICP‐MS: An Assessment of Matrix Effects and the Impact of Laser Wavelengths and Pulse Widths
A new reference material, STDGL3, for the calibration of in situ analyses of sulfide minerals by LA‐ICP‐MS has been developed and characterised. It represents a lithium‐borate‐based glass containing a mixture of Zn‐ and Fe‐sulfide concentrates doped with several chalcophile elements as well as Zr, Gd, Hf and Ta required for assessing common interferences on Ag, Au and Pt. STDGL3 has a wider range of elements and a better homogeneity compared with existing reference materials for LA‐ICP‐MS analysis of sulfides. Compositional variations for most elements are below 3% RSD, below 5% RSD for Ag, Au and Pt, and below 7% RSD for Se, when performing spot analyses with a 50 μm beam size. Its preparation recipe is reproducible allowing for multiple batches to be made. Use of STDGL3 significantly improves accuracy of sulfide mineral analysis by LA‐ICP‐MS when compared with use of other available reference materials. Performance of STDGL3 was evaluated using several different laser systems. No significant change was observed between 193 nm ArF excimer lasers with 5 and 20 ns pulse widths, but use of 213 and 248 nm lasers displays more systematic differences, especially when analysing galena. Correction coefficients are needed for some elements (Zn and Cd in particular) when analysing sulfide minerals using STDGL3 as a calibration reference material.
- 13 June 2023
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 47 (3) , 493-508
Open AccessSTDGL3, a Reference Material for Analysis of Sulfide Minerals by Laser Ablation ICP‐MS: An Assessment of Matrix Effects and the Impact of Laser Wavelengths and Pulse Widths
A new reference material, STDGL3, for the calibration of in situ analyses of sulfide minerals by LA‐ICP‐MS has been developed and characterised. It represents a lithium‐borate‐based glass containing a mixture of Zn‐ and Fe‐sulfide concentrates doped with several chalcophile elements as well as Zr, Gd, Hf and Ta required for assessing common interferences on Ag, Au and Pt. STDGL3 has a wider range of elements and a better homogeneity compared with existing reference materials for LA‐ICP‐MS analysis of sulfides. Compositional variations for most elements are below 3% RSD, below 5% RSD for Ag, Au and Pt, and below 7% RSD for Se, when performing spot analyses with a 50 μm beam size. Its preparation recipe is reproducible allowing for multiple batches to be made. Use of STDGL3 significantly improves accuracy of sulfide mineral analysis by LA‐ICP‐MS when compared with use of other available reference materials. Performance of STDGL3 was evaluated using several different laser systems. No significant change was observed between 193 nm ArF excimer lasers with 5 and 20 ns pulse widths, but use of 213 and 248 nm lasers displays more systematic differences, especially when analysing galena. Correction coefficients are needed for some elements (Zn and Cd in particular) when analysing sulfide minerals using STDGL3 as a calibration reference material.
- Open Access
- 26 May 2023
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
- Vol. 23 (2)
Comparison of lithium borate fusion and four-acid digestions for the determination of whole-rock chemistry – implications for lithogeochemistry and mineral exploration
Mining and exploration companies routinely use four-acid digestion (4AD), inductively coupled plasma, atomic emission spectra/mass spectrometry methods from commercial assay laboratories for analysing drill and rock samples for lithogeochemical assessment and resource reporting. This method is also known to exhibit lower recovery of elements hosted by resistate minerals. To assess the impact of lower recoveries on lithogeochemical interpretation, a suite of commonly used elements for lithogeochemical analysis (high-field-strength elements Zr, Hf, Nb, Ta, Ti and Eu and transition elements V and Sc) was analysed by 4AD and alkali fusion/acid digestion (AFAD). Lower recoveries in the 4AD relative to the AFAD were recorded for Zr, Hf, Nb, Ta, Ti and Eu; Sc and V reported similar concentrations for both decomposition methods. Despite the lower recoveries for Nb, Ta and Ti, element ratios were largely preserved with the 4AD method due to the recoveries covarying at a 1:1 ratio. A plot of Ti/Nb against V/Sc was found to be largely unaffected by decomposition method, producing similar compositional classifications between the two digestion methods. Use of the Eu anomaly (Eu/Eu*) to determine plagioclase fractionation was also found to be unaffected by decomposition method. In contrast, a standard Zr/Ti v. Nb/Y discrimination plot produced incorrect classifications with 4AD producing more mafic and alkaline classifications relative to the AFAD method. Magmatic fertility interpretations utilizing Zr/Hf were also found to be affected in the 4AD results due to the lower recovery of Zr relative to Hf. This resulted in a bias in the 4AD results and produced false-positive anomalism in fertility assessments. Multiple decomposition methods including combinations of acid and fusion methods are recommended for lithogeochemical analysis utilizing large regions of the periodic table. However, if only 4AD data are available, plots such as Ti/Nb v. V/Sc and Nb/Ta, which preserve their ratios, can be used for lithogeochemical classification. Supplementary material: Wholerock geochemical data and detailed methods are available at https://doi.org/10.6084/m9.figshare.c.6444444
- 26 May 2023
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
- Vol. 23 (2)
Open AccessComparison of lithium borate fusion and four-acid digestions for the determination of whole-rock chemistry – implications for lithogeochemistry and mineral exploration
Mining and exploration companies routinely use four-acid digestion (4AD), inductively coupled plasma, atomic emission spectra/mass spectrometry methods from commercial assay laboratories for analysing drill and rock samples for lithogeochemical assessment and resource reporting. This method is also known to exhibit lower recovery of elements hosted by resistate minerals. To assess the impact of lower recoveries on lithogeochemical interpretation, a suite of commonly used elements for lithogeochemical analysis (high-field-strength elements Zr, Hf, Nb, Ta, Ti and Eu and transition elements V and Sc) was analysed by 4AD and alkali fusion/acid digestion (AFAD). Lower recoveries in the 4AD relative to the AFAD were recorded for Zr, Hf, Nb, Ta, Ti and Eu; Sc and V reported similar concentrations for both decomposition methods. Despite the lower recoveries for Nb, Ta and Ti, element ratios were largely preserved with the 4AD method due to the recoveries covarying at a 1:1 ratio. A plot of Ti/Nb against V/Sc was found to be largely unaffected by decomposition method, producing similar compositional classifications between the two digestion methods. Use of the Eu anomaly (Eu/Eu*) to determine plagioclase fractionation was also found to be unaffected by decomposition method. In contrast, a standard Zr/Ti v. Nb/Y discrimination plot produced incorrect classifications with 4AD producing more mafic and alkaline classifications relative to the AFAD method. Magmatic fertility interpretations utilizing Zr/Hf were also found to be affected in the 4AD results due to the lower recovery of Zr relative to Hf. This resulted in a bias in the 4AD results and produced false-positive anomalism in fertility assessments. Multiple decomposition methods including combinations of acid and fusion methods are recommended for lithogeochemical analysis utilizing large regions of the periodic table. However, if only 4AD data are available, plots such as Ti/Nb v. V/Sc and Nb/Ta, which preserve their ratios, can be used for lithogeochemical classification. Supplementary material: Wholerock geochemical data and detailed methods are available at https://doi.org/10.6084/m9.figshare.c.6444444
- 28 February 2023
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 47 (2) , 267-295
Investigation of the Ablation Behaviour of Andradite‐Grossular Garnets and Rutile with Implications for U‐Pb Geochronology
U‐Pb dating of andradite‐grossular garnet (grandite) and rutile by LA‐ICP‐MS can be used to constrain various metamorphic, metasomatic and igneous geological processes. In this study, we examine and compare the impact of different analytical conditions (fluence, pulse width, laser beam size and ablation frequency) on the ablation crater morphology, ablation rates, down‐hole fractionation and U‐Pb ages of grandite and rutile samples of different compositions. The shapes of grandite ablation craters suggest the mineral ablates by classical evaporation with significant melting that cannot be eliminated even at fluences just above the ablation threshold. Grandite garnets with higher andradite proportions have faster ablation rates. The overall low U contents of grandite require using large laser beam sizes to obtain acceptable precision of U‐Pb ages. At such conditions and crater depths < 10 μm, fluences of 2.1 and 3.5 J cm‐2, laser pulse width of 5 ns and 20 ns, and ablation frequencies between 3.5 and 6.5 Hz, obtain similar and reproducible ages when the proportion of grossular is < 35%. Rutile ablation crater morphology shows evidence of melt splashing and thermal stress cracking. They have significant crater bottom features, which increase in relief with lower fluences and a higher number of laser shots, indicating the features are probably energy‐related and making higher fluences, such as 5 J cm‐2, necessary for uniform ablation when using 193 nm excimer lasers. The slow ablation rate at low fluences and then steep increase at around 2.0 J cm‐2 suggests a transition in the ablation mechanism from exfoliation to classical vaporisation. Crater bottom features and other ablation behaviour vary between samples, which could be related to their difference in colour. Although the down‐hole fractionation patterns of the samples are similar at 5 J cm‐2, the U‐Pb ages of some samples vary significantly with different analytical conditions and/or measurement sessions, particularly when using laser beam sizes of 30 μm, suggesting differences in mass bias and more variable ablation behaviour. A laser beam size of at least 60 μm is recommended for reproducible U‐Pb dating of rutile.
- 28 February 2023
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 47 (2) , 267-295
Investigation of the Ablation Behaviour of Andradite‐Grossular Garnets and Rutile with Implications for U‐Pb Geochronology
U‐Pb dating of andradite‐grossular garnet (grandite) and rutile by LA‐ICP‐MS can be used to constrain various metamorphic, metasomatic and igneous geological processes. In this study, we examine and compare the impact of different analytical conditions (fluence, pulse width, laser beam size and ablation frequency) on the ablation crater morphology, ablation rates, down‐hole fractionation and U‐Pb ages of grandite and rutile samples of different compositions. The shapes of grandite ablation craters suggest the mineral ablates by classical evaporation with significant melting that cannot be eliminated even at fluences just above the ablation threshold. Grandite garnets with higher andradite proportions have faster ablation rates. The overall low U contents of grandite require using large laser beam sizes to obtain acceptable precision of U‐Pb ages. At such conditions and crater depths < 10 μm, fluences of 2.1 and 3.5 J cm‐2, laser pulse width of 5 ns and 20 ns, and ablation frequencies between 3.5 and 6.5 Hz, obtain similar and reproducible ages when the proportion of grossular is < 35%. Rutile ablation crater morphology shows evidence of melt splashing and thermal stress cracking. They have significant crater bottom features, which increase in relief with lower fluences and a higher number of laser shots, indicating the features are probably energy‐related and making higher fluences, such as 5 J cm‐2, necessary for uniform ablation when using 193 nm excimer lasers. The slow ablation rate at low fluences and then steep increase at around 2.0 J cm‐2 suggests a transition in the ablation mechanism from exfoliation to classical vaporisation. Crater bottom features and other ablation behaviour vary between samples, which could be related to their difference in colour. Although the down‐hole fractionation patterns of the samples are similar at 5 J cm‐2, the U‐Pb ages of some samples vary significantly with different analytical conditions and/or measurement sessions, particularly when using laser beam sizes of 30 μm, suggesting differences in mass bias and more variable ablation behaviour. A laser beam size of at least 60 μm is recommended for reproducible U‐Pb dating of rutile.
- Open Access
- 18 May 2022
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 590
Implications of high-Mg# adakitic magmatism at Hunter Ridge for arc magmatism of the Fiji - Vanuatu region
- 18 May 2022
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 590
Open AccessImplications of high-Mg# adakitic magmatism at Hunter Ridge for arc magmatism of the Fiji - Vanuatu region
- Open Access
Trace Element Geochemistry of Sulfides from the Ashadze-2 Hydrothermal Field (12°58′ N, Mid-Atlantic Ridge): Influence of Host Rocks, Formation Conditions or Seawater?
The trace element (TS) composition of isocubanite, chalcopyrite, pyrite, bornite, and covellite from oxidized Cu-rich massive sulfides of the Ashadze-2 hydrothermal field (12°58′ N, Mid-Atlantic Ridge) is studied using LA-ICP-MS. The understanding of TE behavior, which depends on the formation conditions and the mode of TE occurrence, in sulfides is important, since they are potential sources for byproduct TEs. Isocubanite has the highest Co contents). Chalcopyrite concentrates most Au. Bornite has the highest amounts of Se, Sn, and Te. Crystalline pyrite is a main carrier of Mn. Covellite after isocubanite is a host to the highest Sr, Ag, and Bi contents. Covellite after pyrite accumulates V, Ga and In. The isocubanite+chalcopyrite aggregates in altered gabrro contain the highest amounts of Ni, Zn, As, Mo, Cd, Sb (166 ppm), Tl, and Pb. The trace element geochemistry of sulfides is mainly controlled by local formation conditions. Submarine oxidation results in the formation of covellite and its enrichment in most trace elements relative to primary sulfides. This is a result of incorporation of seawater-derived elements and seawater-affected dissolution of accessory minerals (native gold, galena and clausthalite).
Open AccessTrace Element Geochemistry of Sulfides from the Ashadze-2 Hydrothermal Field (12°58′ N, Mid-Atlantic Ridge): Influence of Host Rocks, Formation Conditions or Seawater?
The trace element (TS) composition of isocubanite, chalcopyrite, pyrite, bornite, and covellite from oxidized Cu-rich massive sulfides of the Ashadze-2 hydrothermal field (12°58′ N, Mid-Atlantic Ridge) is studied using LA-ICP-MS. The understanding of TE behavior, which depends on the formation conditions and the mode of TE occurrence, in sulfides is important, since they are potential sources for byproduct TEs. Isocubanite has the highest Co contents). Chalcopyrite concentrates most Au. Bornite has the highest amounts of Se, Sn, and Te. Crystalline pyrite is a main carrier of Mn. Covellite after isocubanite is a host to the highest Sr, Ag, and Bi contents. Covellite after pyrite accumulates V, Ga and In. The isocubanite+chalcopyrite aggregates in altered gabrro contain the highest amounts of Ni, Zn, As, Mo, Cd, Sb (166 ppm), Tl, and Pb. The trace element geochemistry of sulfides is mainly controlled by local formation conditions. Submarine oxidation results in the formation of covellite and its enrichment in most trace elements relative to primary sulfides. This is a result of incorporation of seawater-derived elements and seawater-affected dissolution of accessory minerals (native gold, galena and clausthalite).
- 12 February 2020
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
- Vol. 20 (2) , 176-188
Recent advances in the application of mineral chemistry to exploration for porphyry copper–gold–molybdenum deposits: detecting the geochemical fingerprints and footprints of hypogene mineralization and alteration
In the past decade, significant research efforts have been devoted to mineral chemistry studies to assist porphyry exploration. These activities can be divided into two major fields of research: (1) porphyry indicator minerals (PIMs), which are used to identify the presence of, or potential for, porphyry-style mineralization based on the chemistry of magmatic minerals such as zircon, plagioclase and apatite, or resistate hydrothermal minerals such as magnetite; and (2) porphyry vectoring and fertility tools (PVFTs), which use the chemical compositions of hydrothermal minerals such as epidote, chlorite and alunite to predict the likely direction and distance to mineralized centres, and the potential metal endowment of a mineral district. This new generation of exploration tools has been enabled by advances in and increased access to laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), short-wave length infrared (SWIR), visible near-infrared (VNIR) and hyperspectral technologies. PIMs and PVFTs show considerable promise for exploration and are starting to be applied to the diversity of environments that host porphyry and epithermal deposits globally. Industry has consistently supported development of these tools, and in the case of PVFTs encouraged by several successful blind tests where deposit centres have successfully been predicted from distal propylitic settings. Industry adoption is steadily increasing but is restrained by a lack of the necessary analytical equipment and expertise in commercial laboratories, and also by the ongoing reliance on well-established geochemical exploration techniques (e.g. sediment, soil and rock chip sampling) that have aided the discovery of near-surface resources over many decades, but are now proving less effective in the search for deeply buried mineral resources and for those concealed under cover. Thematic collection: This article is part of the Exploration 17 collection available at: https://www.lyellcollection.org/cc/exploration-17
- 12 February 2020
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
- Vol. 20 (2) , 176-188
Recent advances in the application of mineral chemistry to exploration for porphyry copper–gold–molybdenum deposits: detecting the geochemical fingerprints and footprints of hypogene mineralization and alteration
In the past decade, significant research efforts have been devoted to mineral chemistry studies to assist porphyry exploration. These activities can be divided into two major fields of research: (1) porphyry indicator minerals (PIMs), which are used to identify the presence of, or potential for, porphyry-style mineralization based on the chemistry of magmatic minerals such as zircon, plagioclase and apatite, or resistate hydrothermal minerals such as magnetite; and (2) porphyry vectoring and fertility tools (PVFTs), which use the chemical compositions of hydrothermal minerals such as epidote, chlorite and alunite to predict the likely direction and distance to mineralized centres, and the potential metal endowment of a mineral district. This new generation of exploration tools has been enabled by advances in and increased access to laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), short-wave length infrared (SWIR), visible near-infrared (VNIR) and hyperspectral technologies. PIMs and PVFTs show considerable promise for exploration and are starting to be applied to the diversity of environments that host porphyry and epithermal deposits globally. Industry has consistently supported development of these tools, and in the case of PVFTs encouraged by several successful blind tests where deposit centres have successfully been predicted from distal propylitic settings. Industry adoption is steadily increasing but is restrained by a lack of the necessary analytical equipment and expertise in commercial laboratories, and also by the ongoing reliance on well-established geochemical exploration techniques (e.g. sediment, soil and rock chip sampling) that have aided the discovery of near-surface resources over many decades, but are now proving less effective in the search for deeply buried mineral resources and for those concealed under cover. Thematic collection: This article is part of the Exploration 17 collection available at: https://www.lyellcollection.org/cc/exploration-17
- Open Access
- 16 January 2020
- Published by Wiley in ESS Open Archive
Pre-Arc, Near-Trench, Magmatism During Subduction Initiation at the Young (< 2 Ma) Matthew and Hunter Subduction Zone
The Matthew and Hunter (M&H) area, in the South-West Pacific, was formerly interpreted as a transform boundary at the southern termination of the New Hebrides Subduction Zone. But new data collected during three voyages of RV Southern Surveyor (2004-2009), combined with detailed analysis of seismicity and GPS kinematics, shows it is a distinct subduction zone initiated only 2 Ma ago. In fact, M&H is the youngest known volcanically-active intra-oceanic subduction system. We demonstrate that the M&H subduction zone is a modern example of an immature subduction system at the particular stage of pre-arc, near-trench magmatism. It is not yet forming an arc but the proto-forearc. Indeed volcanism occurs much closer to the trench than volcanism at mature subduction zones. Also M&H hosts an exceptionally diverse range of magma compositions, which erupted contemporaneously and are spatially juxtaposed. Pb isotopic compositions and contents of LILE and REE indicate melting of upwelling asthenospheric mantle (Indian MORB) and subducted oceanic crust (Pacific MORB of the South Fiji Basin) and the mixing of these two components. It is worth noting that the present day proto-forearc of the M&H subduction zone corresponds to an area where highly contrasting terranes are juxtaposed: remnants of the old Vitiaz Arc crust, domains of classical backarc basin type oceanic accretion, and what we call Subduction Initiation Terranes (SITER). Such live observations of a growing forearc are rare. They should give insights into the study of fossil forearcs such as SSZ ophiolites but also the IBM forearc.
- 16 January 2020
- Published by Wiley in ESS Open Archive
Open AccessPre-Arc, Near-Trench, Magmatism During Subduction Initiation at the Young (< 2 Ma) Matthew and Hunter Subduction Zone
The Matthew and Hunter (M&H) area, in the South-West Pacific, was formerly interpreted as a transform boundary at the southern termination of the New Hebrides Subduction Zone. But new data collected during three voyages of RV Southern Surveyor (2004-2009), combined with detailed analysis of seismicity and GPS kinematics, shows it is a distinct subduction zone initiated only 2 Ma ago. In fact, M&H is the youngest known volcanically-active intra-oceanic subduction system. We demonstrate that the M&H subduction zone is a modern example of an immature subduction system at the particular stage of pre-arc, near-trench magmatism. It is not yet forming an arc but the proto-forearc. Indeed volcanism occurs much closer to the trench than volcanism at mature subduction zones. Also M&H hosts an exceptionally diverse range of magma compositions, which erupted contemporaneously and are spatially juxtaposed. Pb isotopic compositions and contents of LILE and REE indicate melting of upwelling asthenospheric mantle (Indian MORB) and subducted oceanic crust (Pacific MORB of the South Fiji Basin) and the mixing of these two components. It is worth noting that the present day proto-forearc of the M&H subduction zone corresponds to an area where highly contrasting terranes are juxtaposed: remnants of the old Vitiaz Arc crust, domains of classical backarc basin type oceanic accretion, and what we call Subduction Initiation Terranes (SITER). Such live observations of a growing forearc are rare. They should give insights into the study of fossil forearcs such as SSZ ophiolites but also the IBM forearc.