Eric M. Strohm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric M. Strohm has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Michael C. Kolios
Toronto Metropolitan University
38 shared publications Ivan Gorelikov
Sunnybrook Res Inst, Toronto, ON, Canada
6 shared publicationsNaomi Matsuura
Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
6 shared publicationsYang Sun
Second Affiliated Hospital, Institute of Ultrasound Imaging Chongqing Medical University Linjiang Road 76 Chongqing 400010 P. R. China
5 shared publicationsYuanyi Zheng
Second Affiliated Hospital, Institute of Ultrasound Imaging Chongqing Medical University Linjiang Road 76 Chongqing 400010 P. R. China
5 shared publicationsZhigang Wang
Institute of Ultrasound Imaging, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
5 shared publications
Latest Publications
- 1 December 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (6) , 4193-4201
Pressure estimation of ultra-high frequency ultrasound using gas vesicles
Acoustic microscopy uses ultra-high frequency (UHF) ultrasound transducers over 80 MHz to perform high-resolution imaging. The pressure output of these transducers is unknown, as commercial calibrated hydrophones can measure pressure for transducers with frequencies only up to 80 MHz. This study used gas vesicle nanostructures (GVs) that collapse at 571 kPa to estimate the pressure of UHF transducers at 40, 80, 200, and 375 MHz. Agarose phantoms containing GVs were made, and a baseline ultrasound image was performed at low pressure to prevent GV collapse. Sections within the phantom were scanned at varying voltage to determine the GV collapse threshold. The pressure at full driving voltage was then calculated, assuming a linear relation between transducer voltage and pressure. The pressure calculated for the 40 MHz transducer was 2.2 ± 0.1 MPa at 21 °C. Using a hydrophone, the measured pressure was 2.1 ± 0.3 MPa, a difference of <2%, validating the method at this frequency. The pressure calculated for the other transducers was 2.0 ± 0.1 MPa (80 MHz), 1.2 ± 0.1 (200 MHz), and 1.05 ± 0.17 (375 MHz at 37 °C). This study addresses the challenge of estimating pressure output from UHF ultrasound transducers, demonstrating that the pressure output in the 40–400 MHz frequency range can be quantified.
- 1 December 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (6) , 4193-4201
Pressure estimation of ultra-high frequency ultrasound using gas vesicles
Acoustic microscopy uses ultra-high frequency (UHF) ultrasound transducers over 80 MHz to perform high-resolution imaging. The pressure output of these transducers is unknown, as commercial calibrated hydrophones can measure pressure for transducers with frequencies only up to 80 MHz. This study used gas vesicle nanostructures (GVs) that collapse at 571 kPa to estimate the pressure of UHF transducers at 40, 80, 200, and 375 MHz. Agarose phantoms containing GVs were made, and a baseline ultrasound image was performed at low pressure to prevent GV collapse. Sections within the phantom were scanned at varying voltage to determine the GV collapse threshold. The pressure at full driving voltage was then calculated, assuming a linear relation between transducer voltage and pressure. The pressure calculated for the 40 MHz transducer was 2.2 ± 0.1 MPa at 21 °C. Using a hydrophone, the measured pressure was 2.1 ± 0.3 MPa, a difference of <2%, validating the method at this frequency. The pressure calculated for the other transducers was 2.0 ± 0.1 MPa (80 MHz), 1.2 ± 0.1 (200 MHz), and 1.05 ± 0.17 (375 MHz at 37 °C). This study addresses the challenge of estimating pressure output from UHF ultrasound transducers, demonstrating that the pressure output in the 40–400 MHz frequency range can be quantified.
- Open Access
High-frequency quantitative ultrasound to assess the acoustic properties of engineered tissues in vitro
Acoustic properties of biomaterials and engineered tissues reflect their structure and cellularity. High-frequency ultrasound (US) can non-invasively characterize and monitor these properties with sub-millimetre resolution. We present an approach to estimate the acoustic properties of cell-laden hydrogels that accounts for frequency-dependent effects of attenuation in coupling media, hydrogel thickness, and interfacial transmission/reflection coefficients of US waves, all of which can bias attenuation estimates. Cell-seeded fibrin hydrogel disks were raster-scanned using a 40 MHz US transducer. Thickness, speed of sound, acoustic impedance, and acoustic attenuation coefficients were determined from the difference in the time-of-flight and ratios of the magnitudes of US signals, interfacial transmission/reflection coefficients, and acoustic properties of the coupling media. With this approach, hydrogel thickness was accurately measured by US, with excellent agreement to confocal microscopy (r 2 = 0.97). Accurate thickness measurement enabled acoustic property measurements that were independent of hydrogel thickness, despite up to 60% reduction in thickness due to cell-mediated contraction. Notably, acoustic attenuation coefficients increased with increasing cell concentration (p<0.001), reflecting hydrogel cellularity independent of contracted hydrogel thickness. This approach enables accurate measurement of the intrinsic acoustic properties of biomaterials and engineered tissues to provide new insights into their structure and cellularity.
Open AccessHigh-frequency quantitative ultrasound to assess the acoustic properties of engineered tissues in vitro
Acoustic properties of biomaterials and engineered tissues reflect their structure and cellularity. High-frequency ultrasound (US) can non-invasively characterize and monitor these properties with sub-millimetre resolution. We present an approach to estimate the acoustic properties of cell-laden hydrogels that accounts for frequency-dependent effects of attenuation in coupling media, hydrogel thickness, and interfacial transmission/reflection coefficients of US waves, all of which can bias attenuation estimates. Cell-seeded fibrin hydrogel disks were raster-scanned using a 40 MHz US transducer. Thickness, speed of sound, acoustic impedance, and acoustic attenuation coefficients were determined from the difference in the time-of-flight and ratios of the magnitudes of US signals, interfacial transmission/reflection coefficients, and acoustic properties of the coupling media. With this approach, hydrogel thickness was accurately measured by US, with excellent agreement to confocal microscopy (r 2 = 0.97). Accurate thickness measurement enabled acoustic property measurements that were independent of hydrogel thickness, despite up to 60% reduction in thickness due to cell-mediated contraction. Notably, acoustic attenuation coefficients increased with increasing cell concentration (p<0.001), reflecting hydrogel cellularity independent of contracted hydrogel thickness. This approach enables accurate measurement of the intrinsic acoustic properties of biomaterials and engineered tissues to provide new insights into their structure and cellularity.
- Open Access
Non-invasive quantification of contractile dynamics in cardiac cells, spheroids and organs-on-a-chip using high frequency ultrasound
Cell-based models that mimic in vivo heart physiology are poised to make significant advances in cardiac disease modeling and drug discovery. In these systems, cardiomyocyte (CM) contractility is an important functional metric, but current measurement methods are inaccurate, low-throughput, or require complex set-ups. To address this need, we developed a standalone non-invasive, label-free ultrasound technique operating at 40-200 MHz to measure the beat rate, beat rhythm, and force of contraction of cardiac models, ranging from single adult CMs to 3D microtissue constructs in standard cell culture formats. The high temporal resolution of 1000 fps resolved the beat profile of single mouse CMs paced at up to 9 Hz, revealing limitations of lower speed optical based measurements to resolve beat kinetics or characterize aberrant beats. Coupling of ultrasound with traction force microscopy enabled the measurement of CM longitudinal modulus and facile estimation of adult mouse CM contractile forces of 2.34 ± 1.40 μN, comparable to more complex measurement techniques. Similarly, measurements of beat rate, rhythm, and drug responses of CM spheroid and microtissue models were demonstrated. In conclusion, ultrasound can be used for the rapid characterization of CM contractile function in a wide range of commonly-studied configurations ranging from single cells to 3D tissue constructs using standard well plates, with applications in cardiac drug discovery and cardiotoxicity evaluation.
Open AccessNon-invasive quantification of contractile dynamics in cardiac cells, spheroids and organs-on-a-chip using high frequency ultrasound
Cell-based models that mimic in vivo heart physiology are poised to make significant advances in cardiac disease modeling and drug discovery. In these systems, cardiomyocyte (CM) contractility is an important functional metric, but current measurement methods are inaccurate, low-throughput, or require complex set-ups. To address this need, we developed a standalone non-invasive, label-free ultrasound technique operating at 40-200 MHz to measure the beat rate, beat rhythm, and force of contraction of cardiac models, ranging from single adult CMs to 3D microtissue constructs in standard cell culture formats. The high temporal resolution of 1000 fps resolved the beat profile of single mouse CMs paced at up to 9 Hz, revealing limitations of lower speed optical based measurements to resolve beat kinetics or characterize aberrant beats. Coupling of ultrasound with traction force microscopy enabled the measurement of CM longitudinal modulus and facile estimation of adult mouse CM contractile forces of 2.34 ± 1.40 μN, comparable to more complex measurement techniques. Similarly, measurements of beat rate, rhythm, and drug responses of CM spheroid and microtissue models were demonstrated. In conclusion, ultrasound can be used for the rapid characterization of CM contractile function in a wide range of commonly-studied configurations ranging from single cells to 3D tissue constructs using standard well plates, with applications in cardiac drug discovery and cardiotoxicity evaluation.
- Open Access
- 13 April 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 129 (14) , 141102
A tutorial in photoacoustic microscopy and tomography signal processing methods
Over the last two and a half decades, photoacoustic (PA) imaging has become an important area of research in biomedical optics. Combining the high contrast of optical imaging with the high spatial resolution of ultrasound (US) imaging, PA imaging can simultaneously visualize anatomical structures while interrogating their functionality through multiwavelength optical spectroscopy. Alongside technological developments and imaging applications in optical and acoustic resolution PA imaging, a family of PA signal analysis techniques can extract additional information about the sample being imaged. This Tutorial focuses on techniques that rely on the analysis of PA signals in a manner similar to that in the complimentary field of quantitative ultrasound (QUS) imaging of soft tissues. In QUS, signal analysis techniques have been developed to analyze the US signals resulting from the scattering of many unresolved scatterers within the resolution volume of the imaging device. The implementation of these US techniques in PA can enable new applications in biomedicine beyond traditional anatomical PA imaging, further increasing the utilization and impact of this promising modality.
- 13 April 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 129 (14) , 141102
Open AccessA tutorial in photoacoustic microscopy and tomography signal processing methods
Over the last two and a half decades, photoacoustic (PA) imaging has become an important area of research in biomedical optics. Combining the high contrast of optical imaging with the high spatial resolution of ultrasound (US) imaging, PA imaging can simultaneously visualize anatomical structures while interrogating their functionality through multiwavelength optical spectroscopy. Alongside technological developments and imaging applications in optical and acoustic resolution PA imaging, a family of PA signal analysis techniques can extract additional information about the sample being imaged. This Tutorial focuses on techniques that rely on the analysis of PA signals in a manner similar to that in the complimentary field of quantitative ultrasound (QUS) imaging of soft tissues. In QUS, signal analysis techniques have been developed to analyze the US signals resulting from the scattering of many unresolved scatterers within the resolution volume of the imaging device. The implementation of these US techniques in PA can enable new applications in biomedicine beyond traditional anatomical PA imaging, further increasing the utilization and impact of this promising modality.
- 1 July 2020
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 8 (16) , 4545-4558
Thrombin-responsive engineered nanoexcavator with full-thickness infiltration capability for pharmaceutical-free deep venous thrombosis theranostics
Although nanotechnology has shown great promise for treating multiple vascular diseases in recent years, simultaneous noninvasive detection and efficient dissolution of deep venous thrombosis (DVT) still remains challenging. In particular, long blockage areas and large thrombus thicknesses in DVT cause enormous difficulties for site-specific deep-seated thrombus theranostics. Therefore, based on the unique components of DVT, the novel concept of a thrombin-responsive full-thickness infiltration nonpharmaceutical nanoplatform for DVT theranostics is proposed here. The penetration depth is innovatively enhanced with efficient targeting and accumulation in the whole thrombi. Herein, we report a thrombin-responsive phase-transition liposome incorporating a liquid perfluoropentane (PFP) core and modified with two binding peptides, activatable cell-penetrating peptide (ACPP) and fibrin-binding ligand (FTP), which contribute to efficient liposome targeting and accumulation within the thrombi. This targeted nanoplatform is constructed to dig out the thrombus with the assistance of low-intensity focused ultrasound (LIFU), performing the destructive function of an excavator via an acoustic droplet vaporization effect (acting as a “nanoexcavator” system), which can activate and vaporize into microbubbles to enhance LIFU efficacy. The resulting microbubbles enable real-time monitoring of the therapeutic process with ultrasound imaging and high performance photoacoustic imaging after loading DIR. This non-invasive nonpharmaceutical thrombolytic strategy is an improvement over existing clinical methods without systemic side effects.
- 1 July 2020
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 8 (16) , 4545-4558
Thrombin-responsive engineered nanoexcavator with full-thickness infiltration capability for pharmaceutical-free deep venous thrombosis theranostics
Although nanotechnology has shown great promise for treating multiple vascular diseases in recent years, simultaneous noninvasive detection and efficient dissolution of deep venous thrombosis (DVT) still remains challenging. In particular, long blockage areas and large thrombus thicknesses in DVT cause enormous difficulties for site-specific deep-seated thrombus theranostics. Therefore, based on the unique components of DVT, the novel concept of a thrombin-responsive full-thickness infiltration nonpharmaceutical nanoplatform for DVT theranostics is proposed here. The penetration depth is innovatively enhanced with efficient targeting and accumulation in the whole thrombi. Herein, we report a thrombin-responsive phase-transition liposome incorporating a liquid perfluoropentane (PFP) core and modified with two binding peptides, activatable cell-penetrating peptide (ACPP) and fibrin-binding ligand (FTP), which contribute to efficient liposome targeting and accumulation within the thrombi. This targeted nanoplatform is constructed to dig out the thrombus with the assistance of low-intensity focused ultrasound (LIFU), performing the destructive function of an excavator via an acoustic droplet vaporization effect (acting as a “nanoexcavator” system), which can activate and vaporize into microbubbles to enhance LIFU efficacy. The resulting microbubbles enable real-time monitoring of the therapeutic process with ultrasound imaging and high performance photoacoustic imaging after loading DIR. This non-invasive nonpharmaceutical thrombolytic strategy is an improvement over existing clinical methods without systemic side effects.
- Open Access
- 18 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Sizing biological cells using a microfluidic acoustic flow cytometer
We describe a new technique that combines ultrasound and microfluidics to rapidly size and count cells in a high-throughput and label-free fashion. Using 3D hydrodynamic flow focusing, cells are streamed single file through an ultrasound beam where ultrasound scattering events from each individual cell are acquired. The ultrasound operates at a center frequency of 375 MHz with a wavelength of 4 μm; when the ultrasound wavelength is similar to the size of a scatterer, the power spectra of the backscattered ultrasound waves have distinct features at specific frequencies that are directly related to the cell size. Our approach determines cell sizes through a comparison of these distinct spectral features with established theoretical models. We perform an analysis of two types of cells: acute myeloid leukemia cells, where 2,390 measurements resulted in a mean size of 10.0 ± 1.7 μm, and HT29 colorectal cancer cells, where 1,955 measurements resulted in a mean size of 15.0 ± 2.3 μm. These results and histogram distributions agree very well with those measured from a Coulter Counter Multisizer 4. Our technique is the first to combine ultrasound and microfluidics to determine the cell size with the potential for multi-parameter cellular characterization using fluorescence, light scattering and quantitative photoacoustic techniques.
- 18 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Open AccessSizing biological cells using a microfluidic acoustic flow cytometer
We describe a new technique that combines ultrasound and microfluidics to rapidly size and count cells in a high-throughput and label-free fashion. Using 3D hydrodynamic flow focusing, cells are streamed single file through an ultrasound beam where ultrasound scattering events from each individual cell are acquired. The ultrasound operates at a center frequency of 375 MHz with a wavelength of 4 μm; when the ultrasound wavelength is similar to the size of a scatterer, the power spectra of the backscattered ultrasound waves have distinct features at specific frequencies that are directly related to the cell size. Our approach determines cell sizes through a comparison of these distinct spectral features with established theoretical models. We perform an analysis of two types of cells: acute myeloid leukemia cells, where 2,390 measurements resulted in a mean size of 10.0 ± 1.7 μm, and HT29 colorectal cancer cells, where 1,955 measurements resulted in a mean size of 15.0 ± 2.3 μm. These results and histogram distributions agree very well with those measured from a Coulter Counter Multisizer 4. Our technique is the first to combine ultrasound and microfluidics to determine the cell size with the potential for multi-parameter cellular characterization using fluorescence, light scattering and quantitative photoacoustic techniques.
- 15 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9708, 970826-970826-5
Biodegradable polymer based theranostic agents for photoacoustic imaging and cancer therapy
- 15 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9708, 970826-970826-5
Biodegradable polymer based theranostic agents for photoacoustic imaging and cancer therapy
- Open Access
- 1 March 2016
- Published by Elsevier in Photoacoustics
- Vol. 4 (1) , 36-42
High resolution ultrasound and photoacoustic imaging of single cells
- 1 March 2016
- Published by Elsevier in Photoacoustics
- Vol. 4 (1) , 36-42
Open AccessHigh resolution ultrasound and photoacoustic imaging of single cells
- 29 September 2014
- Published by Wiley in Advanced Functional Materials
- Vol. 24 (48) , 7674-7680
Laser‐Activatible PLGA Microparticles for Image‐Guided Cancer Therapy In Vivo
Poly(lactide‐co‐glycolic acid) (PLGA) particles are biocompatible and biodegradable, and can be used as a carrier for various chemotherapeutic drugs, imaging agents and targeting moieties. Micrometer‐sized PLGA particles were synthesized with gold nanoparticles and DiI dye within the PLGA shell, and perfluorohexane liquid (PFH) in the core. Upon laser irradiation, the PLGA shell absorbs the laser energy, activating the liquid core (liquid conversion to gas). The rapidly expanding gas is expelled from the particle, resulting in a microbubble; this violent process can cause damage to cells and tissue. Studies using cell cultures show that PLGA particles phagocytosed by single cells are consistently vaporized by laser energies of 90 mJ cm−2, resulting in cell destruction. Rabbits with metastasized squamous carcinoma in the lymph nodes are then used to evaluate the anti‐cancer effects of these particles in the lymph nodes. After percutaneous injection of the particles and upon laser irradiation, through the process of optical droplet vaporization, ultrasound imaging shows a significant increase in contrast in comparison to the control. Histology and electron microscopy confirm damage with disrupted cells throughout the lymph nodes, which slows the tumor growth rate. This study shows that PLGA particles containing PFC liquids can be used as theranostic agents in vivo.
- 29 September 2014
- Published by Wiley in Advanced Functional Materials
- Vol. 24 (48) , 7674-7680
Laser‐Activatible PLGA Microparticles for Image‐Guided Cancer Therapy In Vivo
Poly(lactide‐co‐glycolic acid) (PLGA) particles are biocompatible and biodegradable, and can be used as a carrier for various chemotherapeutic drugs, imaging agents and targeting moieties. Micrometer‐sized PLGA particles were synthesized with gold nanoparticles and DiI dye within the PLGA shell, and perfluorohexane liquid (PFH) in the core. Upon laser irradiation, the PLGA shell absorbs the laser energy, activating the liquid core (liquid conversion to gas). The rapidly expanding gas is expelled from the particle, resulting in a microbubble; this violent process can cause damage to cells and tissue. Studies using cell cultures show that PLGA particles phagocytosed by single cells are consistently vaporized by laser energies of 90 mJ cm−2, resulting in cell destruction. Rabbits with metastasized squamous carcinoma in the lymph nodes are then used to evaluate the anti‐cancer effects of these particles in the lymph nodes. After percutaneous injection of the particles and upon laser irradiation, through the process of optical droplet vaporization, ultrasound imaging shows a significant increase in contrast in comparison to the control. Histology and electron microscopy confirm damage with disrupted cells throughout the lymph nodes, which slows the tumor growth rate. This study shows that PLGA particles containing PFC liquids can be used as theranostic agents in vivo.
- 10 September 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (19) , 5795-5810
Modeling photoacoustic spectral features of micron-sized particles
The photoacoustic signal generated from particles when irradiated by light is determined by attributes of the particle such as the size, speed of sound, morphology and the optical absorption coefficient. Unique features such as periodically varying minima and maxima are observed throughout the photoacoustic signal power spectrum, where the periodicity depends on these physical attributes. The frequency content of the photoacoustic signals can be used to obtain the physical attributes of unknown particles by comparison to analytical solutions of homogeneous symmetric geometric structures, such as spheres. However, analytical solutions do not exist for irregularly shaped particles, inhomogeneous particles or particles near structures. A finite element model (FEM) was used to simulate photoacoustic wave propagation from four different particle configurations: a homogeneous particle suspended in water, a homogeneous particle on a reflecting boundary, an inhomogeneous particle with an absorbing shell and non-absorbing core, and an irregularly shaped particle such as a red blood cell. Biocompatible perfluorocarbon droplets, 3-5 mu m in diameter containing optically absorbing nanoparticles were used as the representative ideal particles, as they are spherical, homogeneous, optically translucent, and have known physical properties. The photoacoustic spectrum of micron-sized single droplets in suspension and on a reflecting boundary were measured over the frequency range of 100-500 MHz and compared directly to analytical models and the FEM. Good agreement between the analytical model, FEM and measured values were observed for a droplet in suspension, where the spectral minima agreed to within a 3.3 MHz standard deviation. For a droplet on a reflecting boundary, spectral features were correctly reproduced using the FEM but not the analytical model. The photoacoustic spectra from other common particle configurations such as particle with an absorbing shell and a biconcave-shaped red blood cell were also investigated, where unique features in the power spectrum could be used to identify them.
- 10 September 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (19) , 5795-5810
Modeling photoacoustic spectral features of micron-sized particles
The photoacoustic signal generated from particles when irradiated by light is determined by attributes of the particle such as the size, speed of sound, morphology and the optical absorption coefficient. Unique features such as periodically varying minima and maxima are observed throughout the photoacoustic signal power spectrum, where the periodicity depends on these physical attributes. The frequency content of the photoacoustic signals can be used to obtain the physical attributes of unknown particles by comparison to analytical solutions of homogeneous symmetric geometric structures, such as spheres. However, analytical solutions do not exist for irregularly shaped particles, inhomogeneous particles or particles near structures. A finite element model (FEM) was used to simulate photoacoustic wave propagation from four different particle configurations: a homogeneous particle suspended in water, a homogeneous particle on a reflecting boundary, an inhomogeneous particle with an absorbing shell and non-absorbing core, and an irregularly shaped particle such as a red blood cell. Biocompatible perfluorocarbon droplets, 3-5 mu m in diameter containing optically absorbing nanoparticles were used as the representative ideal particles, as they are spherical, homogeneous, optically translucent, and have known physical properties. The photoacoustic spectrum of micron-sized single droplets in suspension and on a reflecting boundary were measured over the frequency range of 100-500 MHz and compared directly to analytical models and the FEM. Good agreement between the analytical model, FEM and measured values were observed for a droplet in suspension, where the spectral minima agreed to within a 3.3 MHz standard deviation. For a droplet on a reflecting boundary, spectral features were correctly reproduced using the FEM but not the analytical model. The photoacoustic spectra from other common particle configurations such as particle with an absorbing shell and a biconcave-shaped red blood cell were also investigated, where unique features in the power spectrum could be used to identify them.