Sherif Dabash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sherif Dabash has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Ahmed M. Thabet
Texas Tech Univ, Hlth Sci Ctr, Dept Orthopaed Surg, El Paso, TX USA
7 shared publications- Eric Potter
Baylor Scott & White Research Institute, Dallas, TX, USA
6 shared publications Amr Abdelgawad
Texas Tech Univ, Hlth Sci Ctr, Dept Orthopaed Surg, El Paso, TX USA
4 shared publications- Amr Abdelgawad
Maimonides Medical Center, Brooklyn, New York
4 shared publications Chris Gerzina
Orthopaedics Department, Texas Tech University Health Sciences Center, El Paso, TX, USA
3 shared publicationsGautham Prabhakar
Texas Tech Univ, Hlth Sci Ctr, Dept Orthopaed Surg, El Paso, TX USA
3 shared publications
Latest Publications
- 5 March 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (4) , 1877-1882
Limb salvage reconstruction of the lower limb with complex ankle arthrodesis and magnetic internal lengthening nail
Purpose With advances in orthopedic implants, the use of intramedullary lengthening devices has gained increasing popularity as an alternative technique compared to lengthening with external fixators, with alleged comparable or better outcomes. The aim of this study is to report our single-center technique and outcomes of combined ankle arthrodesis and proximal tibial lengthening using external fixator with a motorized intramedullary nail, respectively. Method Fourteen patients with post-traumatic advanced ankle arthritis underwent staged ankle arthrodesis with external fixator and proximal tibial lengthening using the PRECICE® ILN. Amount of shortening, length achieved, bone healing index, infection rate, ankle fusion rate, and ASAMI score were evaluated. Results The average age was 44 years old (range, 30–62). The mean follow up is 70 months (range, 43–121.4). The average amount of limb shortening for patients after ankle fusion was 36.7 mm (18–50) while lengthening was 35.9 mm (range, 18–50). Patients had the nail implanted for an average of 479 days (range, 248–730). Ankle fusions were healed in an average of 178.3 days. There were no surgical infections. All osteotomy-lengthening sites healed after an average 202 days (106–365). The mean bone healing index (BHI) was 56.0 days/cm (21.2–123.6) among the whole cohort. There were no cases of nonunion. ASAMI bone scores were excellent or good among all patients. Conclusion Ankle arthrodesis with external fixation along with proximal tibial lengthening using motorized IMN yielded high rates of fusion and successful lengthening. This technique could be offered as a reasonable alternative to using external fixation for both purposes. Level of Evidence Level IV, Retrospective cohort study.
- 5 March 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (4) , 1877-1882
Limb salvage reconstruction of the lower limb with complex ankle arthrodesis and magnetic internal lengthening nail
Purpose With advances in orthopedic implants, the use of intramedullary lengthening devices has gained increasing popularity as an alternative technique compared to lengthening with external fixators, with alleged comparable or better outcomes. The aim of this study is to report our single-center technique and outcomes of combined ankle arthrodesis and proximal tibial lengthening using external fixator with a motorized intramedullary nail, respectively. Method Fourteen patients with post-traumatic advanced ankle arthritis underwent staged ankle arthrodesis with external fixator and proximal tibial lengthening using the PRECICE® ILN. Amount of shortening, length achieved, bone healing index, infection rate, ankle fusion rate, and ASAMI score were evaluated. Results The average age was 44 years old (range, 30–62). The mean follow up is 70 months (range, 43–121.4). The average amount of limb shortening for patients after ankle fusion was 36.7 mm (18–50) while lengthening was 35.9 mm (range, 18–50). Patients had the nail implanted for an average of 479 days (range, 248–730). Ankle fusions were healed in an average of 178.3 days. There were no surgical infections. All osteotomy-lengthening sites healed after an average 202 days (106–365). The mean bone healing index (BHI) was 56.0 days/cm (21.2–123.6) among the whole cohort. There were no cases of nonunion. ASAMI bone scores were excellent or good among all patients. Conclusion Ankle arthrodesis with external fixation along with proximal tibial lengthening using motorized IMN yielded high rates of fusion and successful lengthening. This technique could be offered as a reasonable alternative to using external fixation for both purposes. Level of Evidence Level IV, Retrospective cohort study.
- Open Access
- 15 October 2020
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 15 (1) , 28-33
Taylor Spatial Frame in Treatment of Equinus Deformity
An equinus deformity interferes with activities of daily living. Correction of the deformity ranges from conservative (heel cord stretching, orthotics) to surgical treatment (Baumann, Strayer, Achilles lengthening, soft tissue releases). Severe contractures increase surgical intervention with extensive dissections to release soft tissues. This study investigated the clinical outcomes of gradual overcorrection using a Taylor spatial frame (TSF) with tendo-Achilles lengthening (TAL) added as necessary. This retrospective chart review evaluated patients with significant equinus treated with a TSF at a single large tertiary referral centre. Data collected included: diagnosis; patient demographics; laterality; time in frame; additional procedures; complications; degree of equinus deformity preoperatively and at every follow-up visit. Patients were followed at 1 week, 3 weeks, 6 weeks, 3 months, and 6 months intervals, and yearly thereafter. Twenty-four patients (26 procedures) were treated with a TSF for equinus and had complete preoperative and follow-up measurements over 2 years. The angle of deformity increased from a preoperative –21.5 (range, –69.0 to –1.0) degrees to a postoperative 4.9 (range, –17.0 to 17.0) degrees (z = –4.4573, p = 0.0001, N = 26, Wilcoxon signed-rank test). A secondary outcome was a weak association (not statistically significant) between time in the TSF and the postoperative deformity angle. Four complications occurred during the follow-up (two pin site infections, one broken pin, and one plantar abscess). Three patients had recurrence of equinus deformity at time of last follow-up. Using a TSF for correcting severe, fixed equinus contractures of the ankle joint is successful with minimal soft tissue-related complications. Overcorrection should be achieved in order to compensate for the loss of some dorsiflexion after frame removal. No added benefit was observed from having the frame on for a long time after correcting the deformity. Adding TAL is not necessary in all cases and required only in severe deformities of more than 25°. Dabash S, Potter E, Catlett G, et al. Taylor Spatial Frame in Treatment of Equinus Deformity. Strategies Trauma Limb Reconstr 2020;15(1):28–33.
- 15 October 2020
- Published by Jaypee Brothers Medical Publishing in Strategies in Trauma and Limb Reconstruction
- Vol. 15 (1) , 28-33
Open AccessTaylor Spatial Frame in Treatment of Equinus Deformity
An equinus deformity interferes with activities of daily living. Correction of the deformity ranges from conservative (heel cord stretching, orthotics) to surgical treatment (Baumann, Strayer, Achilles lengthening, soft tissue releases). Severe contractures increase surgical intervention with extensive dissections to release soft tissues. This study investigated the clinical outcomes of gradual overcorrection using a Taylor spatial frame (TSF) with tendo-Achilles lengthening (TAL) added as necessary. This retrospective chart review evaluated patients with significant equinus treated with a TSF at a single large tertiary referral centre. Data collected included: diagnosis; patient demographics; laterality; time in frame; additional procedures; complications; degree of equinus deformity preoperatively and at every follow-up visit. Patients were followed at 1 week, 3 weeks, 6 weeks, 3 months, and 6 months intervals, and yearly thereafter. Twenty-four patients (26 procedures) were treated with a TSF for equinus and had complete preoperative and follow-up measurements over 2 years. The angle of deformity increased from a preoperative –21.5 (range, –69.0 to –1.0) degrees to a postoperative 4.9 (range, –17.0 to 17.0) degrees (z = –4.4573, p = 0.0001, N = 26, Wilcoxon signed-rank test). A secondary outcome was a weak association (not statistically significant) between time in the TSF and the postoperative deformity angle. Four complications occurred during the follow-up (two pin site infections, one broken pin, and one plantar abscess). Three patients had recurrence of equinus deformity at time of last follow-up. Using a TSF for correcting severe, fixed equinus contractures of the ankle joint is successful with minimal soft tissue-related complications. Overcorrection should be achieved in order to compensate for the loss of some dorsiflexion after frame removal. No added benefit was observed from having the frame on for a long time after correcting the deformity. Adding TAL is not necessary in all cases and required only in severe deformities of more than 25°. Dabash S, Potter E, Catlett G, et al. Taylor Spatial Frame in Treatment of Equinus Deformity. Strategies Trauma Limb Reconstr 2020;15(1):28–33.
- Open Access
- 18 March 2020
- Published by Baishideng Publishing Group Inc. in World Journal of Orthopedics
- Vol. 11 (3) , 145-157
Distraction arthroplasty in osteoarthritis of the foot and ankle
Post-traumatic osteoarthritis (PTOA) is a complex and painful problem in the foot and ankle. Ninety percent of osteoarthritis cases in the foot and ankle can be classified as post-traumatic. PTOA can affect any of the 33 joints in the foot and the ankle. Distraction arthroplasty is a method for treatment of early arthritic joints without fusing or replacing them and its effectiveness has been well documented. The purpose of this case series is to present our successful experiences and positive results using distraction arthroplasty to treat PTOA in the ankle, subtalar, first metatarsophalangeal, and second tarsometatarsal joints, and to present distraction arthroplasty as a viable alternative to invasive joint sacrificing procedures such as arthrodesis or arthroplasty. Distraction Arthroplasty effectively and safely treats PTOA and improves the stability of joints in the Foot and Ankle. Additionally, the use of bone marrow aspirate concentrate as an adjuvant can improve the long-term functional and structural outcomes of the joint, and can prolong the need for further, more aggressive surgical interventions such as fusion or arthroplasty.
- 18 March 2020
- Published by Baishideng Publishing Group Inc. in World Journal of Orthopedics
- Vol. 11 (3) , 145-157
Open AccessDistraction arthroplasty in osteoarthritis of the foot and ankle
Post-traumatic osteoarthritis (PTOA) is a complex and painful problem in the foot and ankle. Ninety percent of osteoarthritis cases in the foot and ankle can be classified as post-traumatic. PTOA can affect any of the 33 joints in the foot and the ankle. Distraction arthroplasty is a method for treatment of early arthritic joints without fusing or replacing them and its effectiveness has been well documented. The purpose of this case series is to present our successful experiences and positive results using distraction arthroplasty to treat PTOA in the ankle, subtalar, first metatarsophalangeal, and second tarsometatarsal joints, and to present distraction arthroplasty as a viable alternative to invasive joint sacrificing procedures such as arthrodesis or arthroplasty. Distraction Arthroplasty effectively and safely treats PTOA and improves the stability of joints in the Foot and Ankle. Additionally, the use of bone marrow aspirate concentrate as an adjuvant can improve the long-term functional and structural outcomes of the joint, and can prolong the need for further, more aggressive surgical interventions such as fusion or arthroplasty.
- 1 February 2020
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 11 (Suppl 1) , S142-S148
The future of the amputees with osseointegration: A systematic review of literature
- 1 February 2020
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 11 (Suppl 1) , S142-S148
The future of the amputees with osseointegration: A systematic review of literature
- 1 January 2020
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 31 (1) , 41-47
Incidence, predictors, and impact of valgus reduction of traumatic intertrochanteric femoral fractures (OTA 31A1-3) treated with the helical blade system: Is anatomic reduction necessary? A retrospective case series
Background: The purpose of this study was to describe the incidence and variables contributing to valgus distraction following cephalomedullary fixation of intertrochanteric femoral fractures with the helical blade system and to determine whether the resulting valgus reduction affected outcomes. Methods: We performed a retrospective case review of cephalomedullary fixation of intertrochanteric femoral fractures between 2009 and 2016. Patients treated with the helical blade system and with at least 6 mo of follow-up were included. Demographic, injury, and surgical variables were extracted from the medical record. At final follow-up complications, including implant failure, blade migration, cut-out, periprosthetic fracture, and reoperation were recorded. Results: Overall, 68 consecutive patients with unilateral intertrochanteric hip fractures were included. Postoperative radiographs demonstrated valgus reduction in 30 (44.1%) patients. At final follow-up, all fractures attained uneventful union. No patient experienced periprosthetic fracture or helical blade cut-out by the time of union and final follow-up. Two patients experienced postoperative infections, both requiring reoperation. Multivariate analysis revealed that only age was marginally predictive of valgus distraction (P=0.061), while fracture stability and blade position were not. Valgus reduction was not predictive of blade migration. Conclusions: Valgus distraction occurred in nearly half (44%) of the patients. While younger age was marginally predictive of this phenomenon, fracture stability and helical blade position were not. Furthermore, valgus reduction had no influence on the presence or degree of blade migration, cut-out, or complications. Therefore, while anatomic reduction may yield aesthetic appeal, time and effort should not be expended on direct anatomic reduction.
- 1 January 2020
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 31 (1) , 41-47
Incidence, predictors, and impact of valgus reduction of traumatic intertrochanteric femoral fractures (OTA 31A1-3) treated with the helical blade system: Is anatomic reduction necessary? A retrospective case series
Background: The purpose of this study was to describe the incidence and variables contributing to valgus distraction following cephalomedullary fixation of intertrochanteric femoral fractures with the helical blade system and to determine whether the resulting valgus reduction affected outcomes. Methods: We performed a retrospective case review of cephalomedullary fixation of intertrochanteric femoral fractures between 2009 and 2016. Patients treated with the helical blade system and with at least 6 mo of follow-up were included. Demographic, injury, and surgical variables were extracted from the medical record. At final follow-up complications, including implant failure, blade migration, cut-out, periprosthetic fracture, and reoperation were recorded. Results: Overall, 68 consecutive patients with unilateral intertrochanteric hip fractures were included. Postoperative radiographs demonstrated valgus reduction in 30 (44.1%) patients. At final follow-up, all fractures attained uneventful union. No patient experienced periprosthetic fracture or helical blade cut-out by the time of union and final follow-up. Two patients experienced postoperative infections, both requiring reoperation. Multivariate analysis revealed that only age was marginally predictive of valgus distraction (P=0.061), while fracture stability and blade position were not. Valgus reduction was not predictive of blade migration. Conclusions: Valgus distraction occurred in nearly half (44%) of the patients. While younger age was marginally predictive of this phenomenon, fracture stability and helical blade position were not. Furthermore, valgus reduction had no influence on the presence or degree of blade migration, cut-out, or complications. Therefore, while anatomic reduction may yield aesthetic appeal, time and effort should not be expended on direct anatomic reduction.
- 1 December 2019
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 25 (6) , 714-720
Adding deltoid ligament repair in ankle fracture treatment: Is it necessary? A systematic review
- 1 December 2019
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 25 (6) , 714-720
Adding deltoid ligament repair in ankle fracture treatment: Is it necessary? A systematic review
- Open Access
- 1 October 2019
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 4 (4)
Using TSF Multi-Planar External Fixation for Overcorrection of Severe Equinus Contractures of the Ankle joint
Category: Ankle, Hindfoot, Trauma Introduction/Purpose: Equinus deformity is a debilitating condition which interferes with the activity of daily living. Correction of the deformity ranges from conservative (heel cord stretching, orthotics) to surgical treatment (Baumann, Strayer, Achilles lengthening, soft tissue releases). Severe contractures need surgical intervention with extensive dissections to release soft tissues. This study investigated the clinical outcomes of gradual equinus contracture overcorrection using a Taylor Spatial Frame with tendo-Achilles lengthening or toe flexor tenotomy as necessary. Methods: This retrospective chart review evaluated patients with significant equinus treated with a Taylor Spatial Frame at a single large tertiary referral center. Data collected included: diagnosis; patient demographics; laterality; time in frame; additional procedures; complications. Patients were assessed preoperatively and were followed at one-week, three-week, six-week, three- month, and six-month intervals, and yearly after. Results: 24 patients (26 procedures) were treated with a Taylor Spatial Frame for equinus and had complete preoperative and eighteen-month follow-up measurements. The angle of deformity increased from a preoperative -21.5 (range, -69.0 to -1.0) degrees to a postoperative 4.9 (range, -17.0 to 17.0) degrees (z = -4.4573, p = 0.0001, N = 26, Wilcoxon signed rank test). Four complications occurred during the follow up (two pin site infections, one broken pin, and one plantar abscess). Three patients had recurrence of of equinus deformity at time of last follow-up. Conclusion: Taylor Spatial Frame is a successful method for correcting severe, fixed equinus contractures of the ankle joint with minimal soft tissue related complications. Over correction should be achieved in order to compensate for the loss of some dorsiflexion after frame removal.
- 1 October 2019
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 4 (4)
Open AccessUsing TSF Multi-Planar External Fixation for Overcorrection of Severe Equinus Contractures of the Ankle joint
Category: Ankle, Hindfoot, Trauma Introduction/Purpose: Equinus deformity is a debilitating condition which interferes with the activity of daily living. Correction of the deformity ranges from conservative (heel cord stretching, orthotics) to surgical treatment (Baumann, Strayer, Achilles lengthening, soft tissue releases). Severe contractures need surgical intervention with extensive dissections to release soft tissues. This study investigated the clinical outcomes of gradual equinus contracture overcorrection using a Taylor Spatial Frame with tendo-Achilles lengthening or toe flexor tenotomy as necessary. Methods: This retrospective chart review evaluated patients with significant equinus treated with a Taylor Spatial Frame at a single large tertiary referral center. Data collected included: diagnosis; patient demographics; laterality; time in frame; additional procedures; complications. Patients were assessed preoperatively and were followed at one-week, three-week, six-week, three- month, and six-month intervals, and yearly after. Results: 24 patients (26 procedures) were treated with a Taylor Spatial Frame for equinus and had complete preoperative and eighteen-month follow-up measurements. The angle of deformity increased from a preoperative -21.5 (range, -69.0 to -1.0) degrees to a postoperative 4.9 (range, -17.0 to 17.0) degrees (z = -4.4573, p = 0.0001, N = 26, Wilcoxon signed rank test). Four complications occurred during the follow up (two pin site infections, one broken pin, and one plantar abscess). Three patients had recurrence of of equinus deformity at time of last follow-up. Conclusion: Taylor Spatial Frame is a successful method for correcting severe, fixed equinus contractures of the ankle joint with minimal soft tissue related complications. Over correction should be achieved in order to compensate for the loss of some dorsiflexion after frame removal.
- 1 March 2019
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 58 (2) , 357-362
Unstable Ankle Fracture Fixation Using Locked Fibular Intramedullary Nail in High-Risk Patients
- 1 March 2019
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 58 (2) , 357-362
Unstable Ankle Fracture Fixation Using Locked Fibular Intramedullary Nail in High-Risk Patients
- 17 October 2018
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 29 (3) , 575-581
Screw fixation for supracondylar humerus fractures in children: a report of seventeen cases
Purpose Supracondylar fractures in the pediatric population are common. For years, K-wires have been the preferred method of surgical fixation. However, fixation with K-wires alone may lead to multiple complications. This study reports the results of surgical care of supracondylar humerus fractures using screw fixation with K-wires or screw fixation alone. Methods This study retrospectively reviewed all patients with supracondylar humerus fractures treated with screw fixation between 2007 and 2013. Patients treated only with smooth wires, or having a displaced medial epicondyle, or presenting with lateral condyle fractures were excluded from the study. Flynn’s criteria were used to determine the outcome. Results Seventeen patients who met inclusion criteria formed the study group. All patients were followed until union, resolution of complications, and return to preinjury activity level. Satisfactory outcome was reported in 70.6% of patients with less than 15° loss of either flexion or extension. Mean time to union was 6.5 weeks (range 3.3–12.1 weeks). Screw fixation alone had a shorter mean time to union (5.5 weeks) than compared screw fixation with K-wires group (6.9 weeks). Full range of motion following surgical invention was associated with Flynn’s criteria (p value = 0.044). Conclusion Screw fixation for pediatric supracondylar fractures is a viable option to achieve healing and early motion in highly unstable fractures as well as fractures which require (1) increased stability, (2) maintenance of stability during wound checks in the immediate postoperative period and after discontinuation of the cast, or (3) if further exploration like associated vascular injury is warranted.
- 17 October 2018
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 29 (3) , 575-581
Screw fixation for supracondylar humerus fractures in children: a report of seventeen cases
Purpose Supracondylar fractures in the pediatric population are common. For years, K-wires have been the preferred method of surgical fixation. However, fixation with K-wires alone may lead to multiple complications. This study reports the results of surgical care of supracondylar humerus fractures using screw fixation with K-wires or screw fixation alone. Methods This study retrospectively reviewed all patients with supracondylar humerus fractures treated with screw fixation between 2007 and 2013. Patients treated only with smooth wires, or having a displaced medial epicondyle, or presenting with lateral condyle fractures were excluded from the study. Flynn’s criteria were used to determine the outcome. Results Seventeen patients who met inclusion criteria formed the study group. All patients were followed until union, resolution of complications, and return to preinjury activity level. Satisfactory outcome was reported in 70.6% of patients with less than 15° loss of either flexion or extension. Mean time to union was 6.5 weeks (range 3.3–12.1 weeks). Screw fixation alone had a shorter mean time to union (5.5 weeks) than compared screw fixation with K-wires group (6.9 weeks). Full range of motion following surgical invention was associated with Flynn’s criteria (p value = 0.044). Conclusion Screw fixation for pediatric supracondylar fractures is a viable option to achieve healing and early motion in highly unstable fractures as well as fractures which require (1) increased stability, (2) maintenance of stability during wound checks in the immediate postoperative period and after discontinuation of the cast, or (3) if further exploration like associated vascular injury is warranted.
- Open Access
- 13 July 2018
- Published by SAGE Publications in HAND
- Vol. 15 (1) , 103-110
Radial Plate Fixation of Distal Radius Fracture
Background: A radial incision with radial plate fixation for distal radius fracture has historically been avoided due to its risk to the superficial branch of the radial nerve (SBRN). With careful technique, it is possible to avoid injury to the SBRN, thereby minimizing the soft tissue injury associated with other approaches. We compare subjective and objective functional outcomes of radial plate fixation surgeries that we performed with those of dorsal and volar plate fixation in current literature. Methods: Patients at a single center who underwent radial plate fixation for an AO type A or AO type B distal radius fracture between December 2006 and December 2014 were enrolled in the study. Postoperative grip strength and 3-digit pinch strength were measured systematically in the injured and uninjured wrists. Patients also completed a Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) questionnaire to assess subjective outcomes. Results: Thirty-six patients met our inclusion criteria and had available medical records. Postoperative grip strength in the injured wrist was significantly lowered—68% compared with the uninjured wrist. After subgroup analysis of dominant and nondominant wrist injuries, there was no significant difference in grip strength between injured and uninjured wrists. There was no significant decrease in postoperative 3-digit pinch strength in the injured wrist—89% compared with the uninjured wrist. The mean QuickDASH score for our study participants was 20.9. Conclusions: Radial plate fixation is an effective approach for distal radius fractures. Objective and subjective outcomes are noninferior to those of a dorsal or volar approach.
- 13 July 2018
- Published by SAGE Publications in HAND
- Vol. 15 (1) , 103-110
Open AccessRadial Plate Fixation of Distal Radius Fracture
Background: A radial incision with radial plate fixation for distal radius fracture has historically been avoided due to its risk to the superficial branch of the radial nerve (SBRN). With careful technique, it is possible to avoid injury to the SBRN, thereby minimizing the soft tissue injury associated with other approaches. We compare subjective and objective functional outcomes of radial plate fixation surgeries that we performed with those of dorsal and volar plate fixation in current literature. Methods: Patients at a single center who underwent radial plate fixation for an AO type A or AO type B distal radius fracture between December 2006 and December 2014 were enrolled in the study. Postoperative grip strength and 3-digit pinch strength were measured systematically in the injured and uninjured wrists. Patients also completed a Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) questionnaire to assess subjective outcomes. Results: Thirty-six patients met our inclusion criteria and had available medical records. Postoperative grip strength in the injured wrist was significantly lowered—68% compared with the uninjured wrist. After subgroup analysis of dominant and nondominant wrist injuries, there was no significant difference in grip strength between injured and uninjured wrists. There was no significant decrease in postoperative 3-digit pinch strength in the injured wrist—89% compared with the uninjured wrist. The mean QuickDASH score for our study participants was 20.9. Conclusions: Radial plate fixation is an effective approach for distal radius fractures. Objective and subjective outcomes are noninferior to those of a dorsal or volar approach.