Van Baxter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Van Baxter has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Abu-Heiba
ORNL
5 shared publications - Viral Patel
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
4 shared publications - Ahmed Elatar
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
3 shared publications - Mingkan Zhang
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
3 shared publications - Omar Abdelaziz
Mechanical Engineering Department, The American University in Cairo, New Cairo 11835, Egypt
3 shared publications - Anthony C. Gehl
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
2 shared publications
Latest Publications
- 1 November 2021
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces
Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical valuesmore » for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs. « less
- 1 November 2021
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces
Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical valuesmore » for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs. « less
- 1 July 2020
- Published by Office of Scientific and Technical Information (OSTI)
Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3
The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team.Three institutions are involved on the US team and have worked on the following projects.•Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems—electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version.•The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. •The National Institute of Standards and Technology (NIST) is working on a field study effort on themore » NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat. « less
- 1 July 2020
- Published by Office of Scientific and Technical Information (OSTI)
Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3
The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team.Three institutions are involved on the US team and have worked on the following projects.•Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems—electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version.•The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. •The National Institute of Standards and Technology (NIST) is working on a field study effort on themore » NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat. « less
- 13 September 2019
- Published by Office of Scientific and Technical Information (OSTI)
Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space
The U.S. Department of Energy's Office of Scientific and Technical Information
- 13 September 2019
- Published by Office of Scientific and Technical Information (OSTI)
Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space
The U.S. Department of Energy's Office of Scientific and Technical Information
- 31 March 2019
- Published by Office of Scientific and Technical Information (OSTI)
Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 2
The U.S. Department of Energy's Office of Scientific and Technical Information
- 31 March 2019
- Published by Office of Scientific and Technical Information (OSTI)
Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 2
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 March 2019
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 March 2019
- Published by Office of Scientific and Technical Information (OSTI)
Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 June 2018
- Published by Office of Scientific and Technical Information (OSTI)
Milestone Report BTO 3.2.2.25 – Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications – Part 1
Refrigerant flammability introduces new challenges to the usage of low global warming potential (Low GWP) refrigerants i n real life applications. Those challenges are centered around the deflagration risk associated with their use and its implications on personal safety. Standards have been developed to systematically set maximum allowable flammable refrigerant charges to ensure safety in case of refrigerant leakage. These standards were initially based on limited testing and numerical analyses of refrigerant leakage into confined spaces.
- 1 June 2018
- Published by Office of Scientific and Technical Information (OSTI)
Milestone Report BTO 3.2.2.25 – Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications – Part 1
Refrigerant flammability introduces new challenges to the usage of low global warming potential (Low GWP) refrigerants i n real life applications. Those challenges are centered around the deflagration risk associated with their use and its implications on personal safety. Standards have been developed to systematically set maximum allowable flammable refrigerant charges to ensure safety in case of refrigerant leakage. These standards were initially based on limited testing and numerical analyses of refrigerant leakage into confined spaces.
- Open Access
- 1 July 2007
- Published by Office of Scientific and Technical Information (OSTI)
Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report
This report documents the development of an air-source integrated heat pump (AS-IHP) through the third quarter of FY2007. It describes the design, analyses and testing of the AS-IHP, and provides performance specifications for a field test prototype and proposed control strategy. The results obtained so far continue to support the AS-IHP being a promising candidate to meet the energy service needs for DOE's development of a Zero Energy Home (ZEH) by the year 2020.
- 1 July 2007
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessAir-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report
This report documents the development of an air-source integrated heat pump (AS-IHP) through the third quarter of FY2007. It describes the design, analyses and testing of the AS-IHP, and provides performance specifications for a field test prototype and proposed control strategy. The results obtained so far continue to support the AS-IHP being a promising candidate to meet the energy service needs for DOE's development of a Zero Energy Home (ZEH) by the year 2020.